    00:30 🔌 Victron Energy uses a specific typology to convert DC power to AC voltage in their MultiPlus inverters and charger inverters, maintaining consistency across their product range.
    01:20 🔄 FET power bridges in Victron inverters control the output voltage by changing the switching length of FETs, achieving accurate and stable sine wave output at 20 kHz.
    03:08 ⚡ Transformers boost the low AC voltage (8-10V) generated by the inverter to standard household voltages like 230V or 120V, depending on the application.
    06:42 ↔️ Victron inverters can synchronize with the grid power supply, allowing seamless transfer of power sources and grid assistance. A relay controls the connection.
    09:56 🔄 Victron inverters can also act as battery chargers by regulating their voltage to facilitate battery charging. The charge current is controlled by adjusting the inverter voltage.

  • @mickmcgood6543
    @mickmcgood6543 6 місяців тому +9

    Wow what a brilliant video! I've often opened these devices and peered inside with very little idea what going on in there. I'm not an electronics technician but this was just at the right level for me to understand it. You are a very good teacher. I guess you know that all us cruising sailors love Victron. We need reliable equipment at the end of the earth.

  • @benveenema
    @benveenema Рік тому +9

    So awesome that Victron took the time to do this video! Love it!

  • @tjairicciardi9747
    @tjairicciardi9747 2 місяці тому +2

    this is the most detailed easy to understand explanation i have ever heard, thank you

  • @donaldpayne1376
    @donaldpayne1376 2 місяці тому +2

    Gidday Johannes
    Excellent explanation video. Thank you.
    I've been reccomending, installing and selling VE equipment for around 20 years and found the support excellent.
    Thank you for quality products.

  • @karlfrederick5731
    @karlfrederick5731 6 місяців тому +3

    A+ Must watch for system builders. Especially explaining sizing the inverters for most efficient use. With a walk through efficiency of the FET's that make the sine wave for the inverter at 11:40

  • @fellpower
    @fellpower 8 місяців тому +2

    I want to live in that factory - and always walk around and see that nice things....great units Victron!

  • @rafam7365
    @rafam7365 5 місяців тому +2

    This is a professional and Simple esplanation. Excellent

  • @jelledegrande149
    @jelledegrande149 Місяць тому +1

    mag ik zeggen: dat de Johannes dit op een eenvoudige en duidelijke wijze kan toelichten . mooi gezegd. Bent u ingenieur van beroep ? Firma's zoals Victron , die technische eigenschappen moeten uitgelegd krijgen voor het onwetende volk ivm elec. , hebben je nodig . bedankt Johannes ,

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz Місяць тому

      Dank Jelle, Ontwetend is wat een groot woord, ieder zn vak zullen we maar zeggen.

  • @xxwookey
    @xxwookey 28 днів тому

    Excellent info. Thanks. Slight editing error: a segment repeats at 17:08-17:30 and 17:31-17:53

  • @danielmcleod1278
    @danielmcleod1278 Місяць тому +1

    Excellent! Thank You

  • @nielsdaemen
    @nielsdaemen 5 місяців тому

    Awesome! You make the best inverters/chargers on the market!

  • @Laurel-Crowned
    @Laurel-Crowned 10 місяців тому +1

    Can't believe I'm bearly seeing this video!

  • @tomtinkertv730
    @tomtinkertv730 6 місяців тому +2

    Very cool to go so deep!
    Praise this competent presentation.
    A wish: Could you do a tech explain vidwo about the various relays in CerboGX and the 250 mppt charge controllers, please?

  • @HarukiYamamoto
    @HarukiYamamoto 6 місяців тому +2

    Thank you so much for this.
    Which size inverter can I use for a 136A surge current produced by a 3kW, single phase, 230V induction motor?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 6 місяців тому

      for a 3kW is a startup of 4-6 x the nominal power needed. Please contact the dealer for more details on models

  • @MP-qn1jw
    @MP-qn1jw 10 місяців тому +1

    My favorite product so far!! Thanks!! How does the AC sync handle an 'eco throttle' generator like a Honda 3K inverter series? When load is added, the engine RPM increases. Will this cause the AC syncs to slip? I'm in the US and use 120VAC @ 60Hz with 12V batteries.

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 10 місяців тому +1

      there is a setting called dynamic current limiter which has a AC input level variation based on the power over a period.

  • @tombouie
    @tombouie 4 місяці тому +2

    Apparently, it comes from God, then to Johannes, & finally to everyone else.
    Yous-bes The-Man Johannes ;)

  • @laurentsosson1739
    @laurentsosson1739 11 днів тому

    Hello
    I’m getting back to you about the multiplus
    can we use the ACin input not permanently on the network but just connect it to a 230V 20A socket (France) to just supply the ACin input to charge a park battery at night rate and use the ACout during the day to restore the energy to my electrical panel?
    because connecting the ACin to the network bothers me a little because you have to do a lot of procedures because if there is a risk of injection into the network you have to go through a Consuel I would especially like to be in self-consumption and from time to time be able to close the multiplus with a source inverter in my prolonged absence and switch to the direct network
    laurent

  • @abisaiamatalo2769
    @abisaiamatalo2769 Рік тому +1

    Amazing videos. Your products look superb.

  • @dogdooish
    @dogdooish 6 місяців тому

    great video, I use Victron for my whole house! :) :) I will be asking support some questions soon!

  • @diegomestrecam7674
    @diegomestrecam7674 Місяць тому +1

    Hello. After watching this I was wondering if a Quattro 8000VA was capable outputting whatever the shore power was capable of (for example 4kW from shore) + the 8kW that the inverter is capable of for a total output of 12kW or the combination is limited to 8kW?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz Місяць тому

      Yes sure , the pass thought is limited by the backfeed relay, often 50-100A , the output is then this plus the inverter power. Thats why often output cabling needed to be larger in size then the input wiring.

  • @gabrielbianco22
    @gabrielbianco22 7 місяців тому

    Que hermosa explicacion!! Muchas gracias!

  • @yuriyura2023
    @yuriyura2023 3 місяці тому

    Could you pls assist, can MultiPlus-II be configured to work the following way: load is supplied by battery/mppt in inverter mode (1 priority) if exceed the max inverter power threshold it will take extra from grid (2 priority). Saying load is 7kva, inverter is 5kva and 2 kva goes from grid? Also if load goes less than inverter power it will not export to the grid (0 is allowed). If this is possible the MultiPlus-II GX version is enough or should I purchase separate cerbo or any other equipment?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 3 місяці тому

      Hello, yes this can be done with the ESS feature (with feedback disabled)
      Your dealer can help you advise in this further.

  • @jmpattillo
    @jmpattillo 2 місяці тому

    Does the relay close when the inverter is turned off, so that AC power passes from the input to the output?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 2 місяці тому

      no, the relay opens (otherwise the inverter would be powered from shore when inactive)

    • @jmpattillo
      @jmpattillo 2 місяці тому

      @@JohannesBoonstra-ol2nz so you have to have the inverter on all the time when plugged into shore power?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 2 місяці тому +1

      @@jmpattillo yes, or select the charger only function so it will charge/passthrough when shore is available

  • @alfrednudze1791
    @alfrednudze1791 4 місяці тому

    Pls I have the victron and is 5000watts inverter but I want victron control charger. Pls how it cost?

  • @jimthvac100
    @jimthvac100 6 місяців тому +1

    which Victron inverters are Low frequency?

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 6 місяців тому +1

      they are all hybrid, so partly HF and partly LF , mainly for isolation /robustness on peak capabilities . the RS models are all HF only

  • @jamesgor13579
    @jamesgor13579 9 місяців тому +1

    The symbol drawn for FETs looks more like a diode. 3:34

    • @johannesboonstra6917
      @johannesboonstra6917 9 місяців тому +2

      Sorry , it is a fet

    • @d.j.wiendels6572
      @d.j.wiendels6572 7 місяців тому +1

      the symbol drawn is a thyristor , probably mosfets are used, since they have higher efficiency, therefore stay cooler

  • @petmen71
    @petmen71 10 місяців тому

    domme vragen zijn er niet maar kan je ok koelen met water neem aan dat de toren warm worden???

    • @JohannesBoonstra-ol2nz
      @JohannesBoonstra-ol2nz 10 місяців тому +1

      In principe wel, paar daar zijn deze units (vanwege de geringe warmte ontwikkeling) niet voor gemaakt.

  • @seyiadetiloye8716
    @seyiadetiloye8716 Рік тому

    Please can I get control board

  • @gabaradama144k9
    @gabaradama144k9 10 місяців тому +4

    I’m sorry, but the guy in the background on the phone that was a little bit rude

    • @VictronEnergyBV
      @VictronEnergyBV  10 місяців тому +2

      It was a fully open and operational chandlery shop.

    • @gabaradama144k9
      @gabaradama144k9 10 місяців тому +1

      @@VictronEnergyBV yes, my friend it sure was excellent video. Excellent product whenever I get a chance to afford a split phase unit. That’s what I’m looking to buy. Thanks thanks again.

  • @sabeergo8033
    @sabeergo8033 9 місяців тому

    Multi plus II 12v/5000va 120 amp 230VAC? New model plz make more enquiry RV

  • @bash1338
    @bash1338 Рік тому

    Does vectron have ups mode

  • @trangnguyen-ex2xe
    @trangnguyen-ex2xe 3 місяці тому +1

    So awesome that Victron took the time to do this video! Love it!

  •  3 місяці тому

    I want to live in that factory - and always walk around and see that nice things....great units Victron!

  •  3 місяці тому

    which Victron inverters are Low frequency?