Why I Failed my detached garage rough In Electrical Inspection

Поділитися
Вставка
  • Опубліковано 19 лис 2024

КОМЕНТАРІ • 344

  • @sapreaper
    @sapreaper 2 роки тому +25

    This is awesome to show your mistakes. Many cannot swallow their pride to do this. Thanks!

    • @JustinsProject
      @JustinsProject  2 роки тому +2

      I try share my failures and successes. Thanks for watching and commenting 👍🏻

    • @sapreaper
      @sapreaper 2 роки тому

      @@JustinsProject No problem! We all made mistakes with wiring. Even electricians do, (Or just get lazy). Keep up the vids!

  • @ivanlapchakov8293
    @ivanlapchakov8293 2 роки тому +22

    inside wire apprentice here, just commenting to say I appreciate the due diligence you've done, in your project. Well made videos documenting your progress. Iv'e learned so much and love the respect you show by commenting thoroughly to all your followers. You're awesome, looking forward to learning more from your videos.

    • @JustinsProject
      @JustinsProject  2 роки тому +3

      Much appreciated 🙏 I try to share the good and bad sides of my projects. We all know it's doesn't always go perfect. Learning from each others successes and failures will make us all better. Thanks for watching and commenting 👍🏻

  • @michaeljanssen2504
    @michaeljanssen2504 Рік тому +10

    Maybe someone already posted this suggestion but there is no need to drive a ground rod - just dig a hole about a foot deep and fill it with water - then take your rod and start working the rod up and down in the hole. The water basically allows you to push the rod completely into the ground or you can use your foot for the last foot or so. I've won multiple bets over the years with this method. Good video!

    • @JustinsProject
      @JustinsProject  Рік тому +2

      Yeah, I have heard about that method. Unfortunately, it was after I beat the shhhh out of that rod, though 🤣 If I ever do it again, I will try the water method. Thanks for watching and commenting 👍🏻

    • @christheisgen
      @christheisgen Рік тому

      uh... i doubt that will work here in vegas. the ground is caliche.

  • @SIL-GMER
    @SIL-GMER 18 годин тому

    I admire the effort, I just had a panel replaced in my house and a subpanel installed in my shop. Based on your effort and headaches, it's the best 2800$ I've spent in a while. Kudos to you sir!

  • @jamesmana5247
    @jamesmana5247 10 місяців тому +4

    Love your honesty. Here in Alaska when the inspector came out he asked me if I cut the ground rods. I looked eye to eye and said if I ever have to do it again. I will get a backhoe dig the hole pour 20 pounds of salt in it and back fill the hole. Me and another much younger guy used my 20 pound sledge hammer. I tell you it made us extra human. LOL Liked to kill us. But i did find out why no contractor ever claimed back the 20 pound hammer.

    • @JustinsProject
      @JustinsProject  10 місяців тому

      Much appreciated 🙏 Thanks for watching and commenting 👍🏻

  • @richarda5396
    @richarda5396 Рік тому +12

    Your the real deal! Not only do you show your mistakes along with the correct method but also the pain in getting it done correctly. I have made many mistakes, (a part leftover from an engine rebuild , forgot to solder one pipe fitting etc.) but hung in there, persisted and yes into the wee hours the morning finished. I learned a lot thank you for sharing!

    • @JustinsProject
      @JustinsProject  Рік тому

      Much appreciated 🙏 I have a huge update video coming out in a couple of days on the progress of finishing my shop. Thanks for watching and commenting 👍🏻

  • @ptso7580
    @ptso7580 2 роки тому +8

    Inspector told me, gotta have a light outside at one entrance of the AG building control by a 3 way or a automatic control via a dusk to dawn . Since the building is an area where the fire department man 24-7, gotta have an exterior disconnect in a area visible for them to turn off. And an exterior mounted GFCI outlet one for each side of the building. Nice love to chew Romex and bugs can nest in breakers. So I wired my pole barn with weather tight NEMA 3 R everything. Even tho it's inside. Also when I had the trench open, I laid in conduit for Ethernet. And when laying out the circuits, made previsions for an exhaust fan to blow out fumes when working inside on the tractor during the extreme hot AZ summers.

    • @JustinsProject
      @JustinsProject  2 роки тому

      Great idea on the internet line. Wish I would have done that. Thanks for watching and commenting 👍🏻

  • @outlawofga
    @outlawofga Рік тому +7

    Much respect for sharing this. This will help many people other than myself. I watched it as a precaution so I didn't have any problems. Thanks Justin

    • @JustinsProject
      @JustinsProject  Рік тому +1

      Much appreciated 🙏 Thanks for watching and commenting 👍🏻

  • @andrerodriguez7603
    @andrerodriguez7603 2 роки тому +8

    The guy at Home Depot told me the easiest way to put a grounding rod is to soak the ground the day before. I left the hose with a trickle of water over night. The grounding rod sank half down with its on weight. Than I just hammered it down the rest of the way. Super easy as the Home Depot guy said. 👍🏻👍🏻

    • @JustinsProject
      @JustinsProject  2 роки тому

      Thanks for sharing that tip. Next time I'll give that a try. Appreciate you watching and commenting 👍🏻

    • @RustyCas999
      @RustyCas999 Рік тому +6

      The easiest way is to by a ground rod tool for your SDS hammer drill!

    • @JustinsProject
      @JustinsProject  Рік тому

      @Rusty Cas Yeah if I ever need to do this again I'll just go out and grab one of those. Never again will I hammer it like I did. Thanks for watching and commenting 👍🏻

    • @michaelhouy1382
      @michaelhouy1382 11 місяців тому

      ​@@JustinsProject It definitely works installing the rod AND removing a buried one. Did it both ways many times

    • @jerrybradshaw9879
      @jerrybradshaw9879 День тому

      Run the rod in a ways and pull it,dump some water in the hole and pump the ground rod up and down,pull and add water. Learned this trick years ago. Can easily hammer the last little bit. For you non-believers,just try it once.

  • @merllhagard6799
    @merllhagard6799 5 місяців тому +2

    As an electrician, you'll have dozens of inspections a year both residential and commercial. Per NEC and different municipal regulations, you'll learn all the little things over the years. With that said, everything in this setup is clean. Good job👍

  • @SavedByFaithInJesus
    @SavedByFaithInJesus 2 роки тому +6

    Great video. The end work looked very nice and neat. Inspectors see neat/clean work and they think you did everything correctly, sloppy work... they start digging. I've never failed an inspection but I've had them call out sloppy work.

  • @krakenwoodfloorservicemcma5975
    @krakenwoodfloorservicemcma5975 2 роки тому +43

    Licensed electrician here and I didn’t know about the agriculture rule either. Nitpicking if you ask me. Wired plenty of pole barns in Romex.

    • @JustinsProject
      @JustinsProject  2 роки тому +3

      Good thing I didn't have the entire building wired than get that news. Caught it early and now I know going forward to just use the MC Cable in that building for any future inspections I might need. Thanks for watching and commenting 👍

    • @larrystuder8543
      @larrystuder8543 2 роки тому +9

      I could see that as one of those "local juristiction" things.

    • @JustinsProject
      @JustinsProject  2 роки тому

      @@larrystuder8543 It could be worse I suppose. All in all not to bad. I don't like working with MC though. I need to look for some tips and tricks to make it easier on myself wiring the rest of the building.

    • @jojogilbert4350
      @jojogilbert4350 2 роки тому +9

      Invest in the rotary cutter meant for mc cable much faster than a hack saw and you don't have to worry about nicking the wires

    • @thomasmarable6818
      @thomasmarable6818 2 роки тому +2

      @@JustinsProject ,I would use pvc conduit. It stand up to elements plus is you use all 3/4 watch you fill if in the future you need to add a circuit just pull in same conduit.

  • @allanpaduchowski1774
    @allanpaduchowski1774 Рік тому +4

    Cool man
    You’re a good man.
    Electrical is life safety and there’s a good reason why you have to install the correct equipment.
    All good we all have done stuff that had to be corrected.
    Good attitude.
    Beautiful place.

    • @JustinsProject
      @JustinsProject  Рік тому

      Must appreciated 🙏 Thanks for watching and commenting 👍🏻

  • @swervomatic
    @swervomatic 2 роки тому +3

    Never wired a agricultural building. Good to know. Thanks for sharing

    • @JustinsProject
      @JustinsProject  2 роки тому

      Thanks for watching and commenting 👍🏻

  • @mikegoff7506
    @mikegoff7506 11 місяців тому +12

    The issue the inspectors had was the unprotected romex. Romex is not rated for exposed installations. Instead of ripping out all your work, you should have been able to frame out your interior walls, ceiling and sheath it with drywall or other sheatgoods to conceal those wires and you would pass your final. That's why you see any unfinished room or building with small sections of drywall installed. Cover the romex and you pass code

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Thanks for watching and commenting 👍🏻

    • @LarsDennert
      @LarsDennert 3 місяці тому

      Exactly. It's not an agriculture building issue. It's just unprotected wire in open walls. Two ground conductors 6' apart is common. Just use the rod itself to measure. The grounding conductor to them per table which seemed to be 8 but he has other ideas.

    • @JustinsProject
      @JustinsProject  3 місяці тому

      @LarsDennert They allow unprotected wires (Romex) in unfinished basements all the time. Most of the time, it's overhead in the floor joist. So, I assume it's also a height threshold as well.

    • @LarsDennert
      @LarsDennert 3 місяці тому

      @@JustinsProject possibly basements are not considered habitable space just like a crawl space or attic. Garages though not technically habitable either, have safety codes especially where fire and ventilation are concerned. There's so many codes, rules and exceptions that following them all without making a mistake is tough. I've seen inspectors make mistakes and omissions as well and I've certainly done some stuff not to code. We all just get smarter as we go.

  • @JD-zf7gf
    @JD-zf7gf Рік тому +6

    Had a similar situation. I live about Midthumb in Michigan and I built a steel building back in 2020 during the Covid era. I got a great deal on it and it’s a wonderful building and Wood was just too expensive at the time. Because it was a steel building yes I had to use all MC cable, I had to use all metal boxes, I was able to use plastic covers which I thought was kind of odd but I didn’t say anything. And I’m with you, I would so much rather use Romax and he said I could if I studed the whole building out. Well if I was going to do that I might as well have just went with a wood building. Now if dad was still alive he could bend pipe in his sleep. He knew how to bend Pipe and even use larger pipe to get more conductors going through it he could make it look all nice and pretty. I could but I don’t have five years to do it so I use the MC, and my building isn’t even close to the size of yours. But yeah they made me jump through some hoops with it but nonetheless, I’m glad you got it all taken care of and yeah, good thing you didn’t have it all done and then he tells you you were wrong. But nonetheless, thanks for the video you did a nice job.

    • @JustinsProject
      @JustinsProject  Рік тому +1

      My father was the same way. He could build and make just about anything work. He would have loved to be part of all these projects I got going on. One thing I never worked with him on was mc, that was kinda foreign to me when I started this project. Now, knowing that I ended up finishing the inside of my shop, I wish I used romex everywhere. I'm glad you got all of yours taken care of also. Thanks for watching and commenting 👍🏻

  • @yodabolt1247
    @yodabolt1247 Рік тому +2

    I ran all the wiring in my shed in EMT conduit with THHN wiring, but it's sub panel is connected to the main panel with buried UF cable and I was told the buildings were too close to require a separate grounding rod. I installed all the outlets and lighting circuits but an electrician set the panel and made the connection to the main.

    • @JustinsProject
      @JustinsProject  Рік тому

      Awesome stuff! Thanks for watching and commenting 👍🏻

  • @makebelieveballroom
    @makebelieveballroom 4 місяці тому +1

    Good job brother. Good info for those that don't know. Glad to see no bitterness about the inspector. A lot of people would blame the inspector for their shortcoming. The NEC and inspectors are there for safety. 99.9% of inspectors want it to be safe. There are a few who are impressed with their title. Ag and industrial wiring must be protected using MC (metal clad) cable, emt, rigid, or pvc conduit. Nice vid!

  • @aha5248
    @aha5248 2 роки тому +4

    Glad you passed! I failed a few months ago for an agricultural building that I used MC in. He said it needed to be the jacketed type mc - which he read as the vinyl coated mc. Expensive interpretation

    • @JustinsProject
      @JustinsProject  2 роки тому

      Wow! That's craziness. Thanks for sharing. Thanks for watching and commenting 👍🏻

    • @leesummers6979
      @leesummers6979 Рік тому +1

      You should have asked him to site the reference. We use standard MC cable in ag buildings all the time. He's going to tell you a barn is a damp location. Tell him to prove it to you in the IBC.

    • @michaeljennings5170
      @michaeljennings5170 Рік тому

      Thats bullshit from a bancrupted electrician now inspector.

    • @boulderboy245
      @boulderboy245 Рік тому

      @@leesummers6979 NEC 547.5 (A) The only MC permitted is jacketed type MC in agricultural buildings.

    • @johndavies2949
      @johndavies2949 Рік тому

      Unfortunately he's right. It's in the NEC in the article specifically written for agriculture structures.

  • @chriserickson4417
    @chriserickson4417 7 місяців тому +1

    Thanks for the video. I'm looking to put in a sub-panel in my garage, but not looking forward to all the work. Thanks again for the education.

    • @JustinsProject
      @JustinsProject  7 місяців тому

      Thanks for watching and commenting 👍🏻 Goodluck with your install.

  • @JEEPLIFE121
    @JEEPLIFE121 8 місяців тому +1

    Great job
    I found it easier to leave the MC spool at the panel and pull the cable to where it needs to go instead of starting at a switch in pulling the wire out of the spool and carrying the spool with you

    • @JustinsProject
      @JustinsProject  8 місяців тому

      Thx. Appreciate the tip. Thanks for watching and commenting 👍🏻

  • @johnkulpowich5260
    @johnkulpowich5260 Рік тому +1

    Thank you. It's simple. But it takes more time than people really think.
    Its only a pice of wire

  • @pmaddox
    @pmaddox Рік тому +1

    Dang Brother! you kinda do it all....appreciate someone who takes care of business, oh to be young again....LOL....62 here and still this old Dog is learning new tricks all the time on UA-cam...thanks again for your vids...I had to subscribe to your channel...see ya in your next vid...I will slowly but surely check them all out in due time...Peace to You and Yours good Sir...Paul and Dede from Indianapolis, Indiana...

    • @JustinsProject
      @JustinsProject  Рік тому

      Much appreciated 🙏 Thanks for watching and commenting 👍🏻 Hope to have a new video coming soon.

  • @burtburt1755
    @burtburt1755 6 місяців тому +1

    I learned a lot today from you and and the other comments. I for one really like your building. Nice job...

    • @JustinsProject
      @JustinsProject  6 місяців тому

      Thanks for watching and commenting 👍🏻

  • @Doug-gp2qw
    @Doug-gp2qw Рік тому

    For driving grounding rods I took a 10 foot stick of 1/2 inch EMT. I put an angle cut on one end and attached a fitting for a garden hose on the other. Attach a garden hose then just run it up and down, letting the water the dig the hole. Then take it out and tap in the ground rod.

  • @nutnutrichburg1
    @nutnutrichburg1 Рік тому +3

    Use bracket 4square boxes and raised covers it’ll allow more space when you terminate

  • @bigdaddy4975
    @bigdaddy4975 2 роки тому +5

    Did you know mc cable actually has a one way spiral on them so they do pull easier thru studs if you have it in the correct orientation you really find this out when trying to pull it thru metal studs.

    • @JustinsProject
      @JustinsProject  2 роки тому

      I do now 😁 Thanks for watching and commenting 👍🏻

  • @ericfraser7543
    @ericfraser7543 2 роки тому +4

    7:00 the sell bit which goes on a hammer drill to hammer those rods in the ground, worked like butter for me... I also saw a video of someone who used water hammer them into the ground with their bare hands most of the way...

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      Thankfully I don't have drive anymore in the ground at this time. Thanks for the heads up on the hammer drill tactic. I have a good strong Bosch hammer drill that could have saved me a shhh ton of work had I known beforehand. Thanks for watching and commenting 👍🏻

    • @SavedByFaithInJesus
      @SavedByFaithInJesus 2 роки тому +1

      Worst part of EVERY job... driving those by hand. My boss finally got a hammer drill with the 5/8 adapter.... smooth as butter. Wear hearing protection.

    • @ericfraser7543
      @ericfraser7543 2 роки тому +1

      @@JustinsProject I was lucky, I picked up a used Bosch hammer drill and a bunch of other klien electrical stuff from retired electricians estate sale, the case only had one weird bit, after googling I figured out it was for hammering in rods and retailed for $50... I have seen them in the $20 range, or the water method stick a hose with running water in the hole with the rod as you slide the rod up and down...

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      @@ericfraser7543 Nice, love auctions. Sometimes you get something cool even when you didn't know it was cool.

  • @williamhelgren4822
    @williamhelgren4822 Рік тому +1

    Thanks for the video, clears up a good bit of questions and you talk like me(no offense) so I can understand what you’re explaining. Now do a 60 amp run 200 feet. That’s my current project.

    • @JustinsProject
      @JustinsProject  Рік тому

      🤣 Thanks! I am working on wiring the building now and hooking up a 50amp circuit for welding. That's about as close to 60 I will get in there. Thanks for watching and commenting 👍🏻

  • @farmboycharlie6543
    @farmboycharlie6543 11 місяців тому +1

    All my farm wiring is in conduit. Eliminates ground issues and incidental damage. When you mix in heavy equipment or animals something always is going to snag that wire regardless of how many staples. Once in good for a lifetime and easier to expand

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Thanks for watching and commenting 👍🏻

  • @howdydoodey3872
    @howdydoodey3872 10 місяців тому +1

    A hard to do confession; but the Reg's are available, most likely at the local library, and even on on-line. I'm an electrician and I still have to read the Reg's now and then to keep my own work sharpened. There are also things called "Amendments" as compulsory reading.

    • @JustinsProject
      @JustinsProject  10 місяців тому

      Thanks for watching and commenting 👍🏻

    • @rogerwhiting9310
      @rogerwhiting9310 10 місяців тому

      My SIL is a Master Electrician in MASSACHUSETTS and I am astounded by the number of codes there are to follow. Most of what I have wired in 50 years is perfectly safe...but there is a code violation around every corner. I think they get carried away with some of the petty stuff.

  • @chipdayton1625
    @chipdayton1625 2 роки тому +4

    I'm surprised the inspector didn't say anything about the plastic cover plates. They often require metal when there is no wall board.

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      Yeah me too 😁 I had them on hand just incase. I hate those metal covers lol I'm glad it was ok on the covers that I had on there though.

    • @thomasmarable6818
      @thomasmarable6818 2 роки тому

      Or the unbreakable plastic ones

  • @KevinCoop1
    @KevinCoop1 2 роки тому +8

    Sorry to hear that you are having issues. The two ground rods and #6 copper is correct no matter what kind of building it is classified.
    I’m not sure why you had it classified as Agricultural but so be it. The NEC article dealing with Ag Building electrical installations is Article 547. 547.1 says that that portion of NEC applies to areas within buildings with Dust and dust with water, and also Corrosive Atmosphere. Whom what I see, you will never have either of these two conditions that would require you to apply 547 rules. Article 547.3 says where you do not have those conditions in 547.1, the electrical installations shall be made in accordance with the applicable articles in this Code. That means that you are not required to use only wiring methods listed in 547. So, your original installation with NM-B cable and plastic boxes is NEC correct. Warning though, you may be required to protect all cables below 8’ from physical damage since you are not installing in enclosed walls.
    My suggestion. Discuss article 547.1 and 547.3 with your inspector and see if they will agree that those rules do not apply to your building.
    Respectfully, Kevin

    • @JustinsProject
      @JustinsProject  2 роки тому +2

      Much appreciated 🙏 We got it all sorted out and got the "pass" with those changes. It is classified as a agricultural building because that is the building permit I pulled with planning and zoning. Saved me 10's of thousands of dollars on the build. My acreage allowed for us to utilize that type of permit so we did. I also planned on the structure being the base for our solar array. Which is working out nicely so far.

    • @KevinCoop1
      @KevinCoop1 2 роки тому +3

      @@JustinsProject The point is, future electrical work in the building is not required to comply with article 547 of the NEC and your inspector needs to be made aware of that. Right is right!

    • @JustinsProject
      @JustinsProject  2 роки тому +2

      @@KevinCoop1 I definitely agree 👍🏻 💯 I will be pointing out those articles when I expand on the wiring in this building.

    • @RustyCas999
      @RustyCas999 Рік тому

      @@JustinsProject Just curious how it saved you 10’s of thousands of dollars. Could you not use pole barn construction if it was not agricultural? Where I live (“out in the county” in rural Arkansas) we have no codes, no inspections, and no permits required, at least for residential. Makes things a lot easier, but also “buyer beware” when you buy property.

    • @JustinsProject
      @JustinsProject  Рік тому

      @@RustyCas999 If it was not an ag permit it would require poured footers, trusses would have to be 16in or 24in OC, and complete outer sheeting would have been required before the metal went up. Several other factors that would increase the cost but those are some big ones. Thanks for watching and commenting.

  • @douglasvamateurradioandmore
    @douglasvamateurradioandmore Рік тому +2

    I have access to an sds plus hammer drill, i just had to purchase to ground rod driver bit. It makes short work of driving ground rods. Until you hit a big rock or thick caliche.
    I always wonder what the reasons are for particular codes. There usually is a reason. Although, it seems that the intent isn't always followed, but the exact letter.

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Funny story. I own an SDS and I didn't even think about using it. 🤣 Thanks for watching and commenting 👍🏻

  • @TheBaldDog32
    @TheBaldDog32 2 роки тому +2

    About to embark on a similar project for a detached garage.... alot of good info here! (Not just the video, but you've got some great commenters as well... the pro's I mean)

    • @JustinsProject
      @JustinsProject  2 роки тому

      Much appreciated 🙏 Thanks for watching and commenting 👍🏻

    • @keithharrington8715
      @keithharrington8715 2 роки тому +1

      Frank, his building classification hosed him here. A garage or out building can be wired like a house. The recepticles need gfci protection iaw 210.8.
      An agricurtural building may get you tax advantages or some other advantage, but they expect animals or fish to be in an agricultural building and that adds requirements to keep the animals safe and the electrical system safe.
      Also, consider your trenches carefully. While they are open consider several conduits.....
      One big enough for a 200 Amp run. You can run a #14 wire circuit in a 2 in pipe, you could then slide that out with a rope attached to pull in a 2/0.circuit whenever you want. At least no more trenching to boost up your power.
      And maybe 2 smaller conduits....
      When your hobby becomes a part time job, you might want cable for TV or data to hardwire internet or security cameras or even some flashing lights....a dinnerbell or emergency warning light that flashes so you can see it when your work blocks the sound of your phone.
      If the trench is open, you can just throw the pipes in and vacuum in a string. Then cap them for future use with no need to re-dig anything.
      More expense, yes. Cheaper than re-digging a second trench....you bet.
      Hope that helps.

  • @columbuspalmer846
    @columbuspalmer846 6 місяців тому +1

    That’s good to know. We all are not perfect even the best experienced electricians gets it wrong sometimes.

    • @JustinsProject
      @JustinsProject  6 місяців тому

      Thanks for watching and commenting 👍🏻

  • @tygrahof9268
    @tygrahof9268 9 місяців тому

    Almost wired a dance hall in Romex but decided to ask about the wires. It too had to be in M/C cable because of number of people, capacity of the hall. Glad I asked!! Also, you can use such a short grounding rod? Here it is a TEN foot rod always! Hmmm...

    • @JustinsProject
      @JustinsProject  9 місяців тому

      Thanks for watching and commenting 👍🏻

  • @tomstdenis
    @tomstdenis 2 роки тому +3

    un-armoured cable would also fail in an unfinished utility room if not tucked into the joists/etc (e.g. out of reach).

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      Makes sense to me. From my understanding that is same concept for the ag building. Because the walls and ceilings are exposed and not covered it requires the MC or Conduit. However the inspector stated it stills needed to be secured in the wall cavity similar to the Romex wiring would be. Thanks for watching and commenting 👍

  • @karenstein8261
    @karenstein8261 11 місяців тому +1

    On the plus side: The inspector was apparently happy with the way you ran the feed to your barn. Most folks mess up there.
    An outside disconnect is often required.
    I am surprised you were able to use just "ordinary" breakers. I can see such a job requiring AFCI breakers, GFCI breakers, and a surge suppressor.
    Some might have required the use of weatherproof boxes and WR rated receptacles.

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Everything was required to be on a gcfi breaker or outlet. I chose to install the outlet method. If I had it to do over, I would do dual functional breakers.

  • @patrickmorris9710
    @patrickmorris9710 10 місяців тому +1

    In one area did not want bonding bushings in the meter base and over in another city required a bonding bushing in the meter while doing a service change at a house.

    • @JustinsProject
      @JustinsProject  10 місяців тому

      Thanks for watching and commenting 👍🏻

  • @peteprivate
    @peteprivate 2 роки тому +1

    Where the MC cable comes down and then turns 180 to the bottom of the switch box. The radius of the 180 bend looks tight. Rule for MC is radius no more then 7 times diameter of cable.

    • @JustinsProject
      @JustinsProject  2 роки тому

      Is that calculated from the cable or the wire size? It's about a 5in radius on that loop. The metal housing is about 1/2in. The wire is 14 on that switch. I think it's good to go on that loop. Thanks for watching and commenting 👍🏻

  • @williamlovelace9633
    @williamlovelace9633 Рік тому +1

    Excellent video! Been there and done that😊 Doing it the right way isn't necessarily easy.

    • @JustinsProject
      @JustinsProject  Рік тому +1

      Appericate it! True, but it is the only way to do it. Even if it takes a little more effort. Thanks for watching and commenting 👍🏻

  • @vet137
    @vet137 2 роки тому +1

    Just crusing the tube ended up watching, shucks I actually learned some stuff I did not know so thank you and you are quite a character but a good one! Oh and that rod driving is always interesting, I got lucky on all 3 I ever did but out of breath each time 😜

    • @JustinsProject
      @JustinsProject  2 роки тому

      Much appreciated 🙏 Thanks for watching and commenting 👍🏻

  • @keithknechg3217
    @keithknechg3217 5 місяців тому +1

    A primary disconnection for feeders in isolated from primary bldg. must be well marked.a main might suffice but a seperate disconnect close to entrance would be best.

  • @rivernet62
    @rivernet62 2 роки тому +3

    My electrician told me the hot tip for driving rods... chuck it up in an impact drill and it goes down like a knife thru butter. Good to know now you're done ;)

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      👍🏻 Next time I'll definitely go that route. Thanks for watching and commenting 👍🏻

    • @patmcbride9853
      @patmcbride9853 2 роки тому

      There are also bits you can buy for SDS type impact drills that slip over the end of the rod.

  • @skipduld3630
    @skipduld3630 Рік тому +1

    IV WORK AT THE USNA FOR 10 YRS, AND THATS ALL I USED IS MC CABLE. AT THAT TIME IT WAS CALLED ARMERED CABLE WITH NO GROUND. IF U WANTED A GROUND CABLE IN IT U WOULD HAVE TO PAY EXTRA. I DIDN'T KNOW ABOUT PULL BURN'S. GREAT VID'S TKS.

    • @JustinsProject
      @JustinsProject  Рік тому

      Thanks for watching and commenting 👍🏻

    • @pld8993
      @pld8993 Рік тому

      MC is not the same as armored cable, they're different products.

  • @caliguy1500
    @caliguy1500 Рік тому +7

    This is why people just forgo the permitting process and do their own thing, because of technicalities that cost money but actually offer no benefit to application at hand.

    • @JustinsProject
      @JustinsProject  Рік тому +1

      Thanks for watching and commenting 👍🏻

    • @manandatractor
      @manandatractor Рік тому +2

      When your barn burns to the ground and the insurance company catches the lack of permitting and code compliance, then guess who doesn't get a check.

    • @pokechamp003
      @pokechamp003 Рік тому +2

      its not a "technicality " you cant run romex exposed anywhere.

    • @silverbackag9790
      @silverbackag9790 Рік тому

      @@manandatractornot everyone lives in an area with permits and inspections. What then?

  • @rich.trails
    @rich.trails Рік тому +2

    I wonder if the no romex in an ag building has to do with it being exposed in open walls. The rule here is if romex, need to cover walls with drywall/wood etc.

    • @JustinsProject
      @JustinsProject  Рік тому +2

      100% Now that I am finishing it and covering the walls, romex is allowed. Thanks for watching and commenting 👍🏻

  • @hotratz69
    @hotratz69 10 місяців тому

    The beauty of using conduit over MC is, your system is easily expandable if you need to change or add a circuit. You just need to be aware of conduit fill and deration requirements.

    • @JustinsProject
      @JustinsProject  10 місяців тому

      Thanks for watching and commenting 👍🏻

  • @perkinsfootprints4125
    @perkinsfootprints4125 Рік тому

    Your awesome!! Keep it up and keep doin vids! Like how you present yourself and the way you tackle projects and overcoming everything that comes with the nature of the beasts!! Raw and Real is the deal and you are the R&R!!!

    • @JustinsProject
      @JustinsProject  Рік тому

      Much appreciated 🙏 Thanks for watching and commenting 👍🏻

  • @KapKen
    @KapKen Рік тому +1

    Thank you Justin... This was the information I need to wire my metal garage. U Da Man 😁

  • @davereynolds6912
    @davereynolds6912 2 роки тому +1

    Gfci is mostly for any area that can get wet! Or where you would plug a extension cord in and take that to wet location. Gfci circuits do not play nice with motors like refrigerator and air compressor.

    • @JustinsProject
      @JustinsProject  2 роки тому

      I put everything in the building on a GFCI. Each circuit starts with one and then down the line is protected by it. Still working on configuring how I want to layout my shop. It's a process, but already know it is not big enough 🤣

  • @brandonharris305
    @brandonharris305 Рік тому +1

    Take the lug off feed it to where you need it then bend it...also it's always 2 ground rods and number 6 unless it's protected

  • @housescasa
    @housescasa 11 місяців тому +1

    What are the details on the lights? They look good! Where did you get them?

    • @JustinsProject
      @JustinsProject  11 місяців тому

      I picked them up at Menards, but you can get them on Amazon if you don't have a Menards in your area. Thanks for watching and commenting 👍🏻

  • @Countryguyaz
    @Countryguyaz 6 місяців тому +1

    What lights did you install on your ceiling, what is the spacing you used, and what is your ceiling height if you wouldn’t mind sharing please? After the fact, are you still happy with them?

    • @JustinsProject
      @JustinsProject  6 місяців тому

      12ft ceilings, bought the lights at Menards, yes, still happy. I have more videos on my build out of the stop. It looks a lot different now.

  • @tomrunning357
    @tomrunning357 Рік тому +1

    I know codes vary from state to state but the building I just built has a floating slab with a thicker outer edge. The building is bolted to it. I wonder if that is considered a footing. Thanks for the heads up to check my buildings classification.

    • @JustinsProject
      @JustinsProject  Рік тому

      Your welcome. Thanks for watching and commenting. 👍

  • @davereynolds6912
    @davereynolds6912 2 роки тому +1

    Ask your inspector but the way I read it once you reach the rafters (out of potential damage zone) you can run romex

    • @JustinsProject
      @JustinsProject  2 роки тому

      I am trying to determine if MC would be needed if I finish the walls. The wire would be protected at that point also. Thanks for watching and commenting 👍🏻

    • @davereynolds6912
      @davereynolds6912 2 роки тому

      @@JustinsProject the key is protection of the wires
      Even if you cover the area around the main until it gets too 7 ft

    • @JustinsProject
      @JustinsProject  2 роки тому

      @@davereynolds6912 I remember him saying something like that also. I told him I wasn't finishing it anytime soon... but now I want to finish a section. I will probably do videos on that process as well.

  • @mdunbar008
    @mdunbar008 11 місяців тому +1

    It is so nice to live where there are no permits or inspections.

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Thanks for watching and commenting 👍🏻

  • @donatoforte2833
    @donatoforte2833 Рік тому +1

    Nice shop! Great job.

  • @frommycoldhands
    @frommycoldhands 7 місяців тому

    2 ground rods 5/8 inch 6 feet apart with #6 ground wire for 100 amp and a #4 ground wire for a 200 amp

    • @JustinsProject
      @JustinsProject  7 місяців тому

      Thanks for watching and commenting 👍🏻

  • @billywillhite7682
    @billywillhite7682 Рік тому +1

    How nice it is to drive a ground rod into the ground. Doesn’t work so well here in Vegas

    • @JustinsProject
      @JustinsProject  Рік тому

      Lots of rock out there? It would be nicer to be able to drive it with the proper tools, though. Thanks for watching and commenting 👍🏻

  • @Lonewolf3165
    @Lonewolf3165 2 роки тому +1

    Thanks for posting this and your other video. I just had a pole building built and we’re getting ready to do the electric. Did they tell you why you can’t use Romex in the barn?
    Another question unrelated but, What did you use for insulation on your walls?
    Thanks.

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      Yes, he mentioned that romex was not allowed in this building because it was technically a ag building. Because it's an ag building the wiring may be exposed and must be protected in a conduit for some sort. It would be tricky if the wires were gong to be behind covered walls but at this time my are not. I have not installed studs or insulation at this time but I am in the process of prepping to do some of the framing very soon. I will be using 24" OC framing and R19 in the walls when I do complete it though. I hope that helps! Thanks for watching and commenting.

  • @beater6967
    @beater6967 2 роки тому +2

    How do you know armored cable will pass inspection? The NEC specifically says that it is not permitted where subject to damage.

    • @JustinsProject
      @JustinsProject  2 роки тому +2

      It did pass the inspection on this go. Inspector advised it would still need to be secured in the wall cavity similar to the Romex wiring would be. I'm glad we got it worked out and I can start the next wiring project, wiring my solar array on the roof. Thanks for watching and commenting 👍

    • @thomasmarable6818
      @thomasmarable6818 2 роки тому

      Yes but what kind of damage, I seen 4" rigid metal conduit damaged outside of a building.

    • @keithharrington8715
      @keithharrington8715 2 роки тому

      The NEC section covering this building lists wiring methods allowed. Section 547.5.(A). Lists the allowed methods......uf cable, se cable, pvc conduit, and many more..

  • @Pepe-dq2ib
    @Pepe-dq2ib Рік тому +1

    MC is expensive. Buying an EMT bender, emt conduits and thhn/thwm wires cost the same, but is much neater and you can fish additional wires through the emt later if room is permitted. Dont buy your wires from the local stores either, order them, a 250ft spool of 12g thhn is $50.

    • @JustinsProject
      @JustinsProject  Рік тому

      I have it all concealed behind the walls now. I've been finishing it out for several months. Just 2 more rooms to complete. Thanks for watching and commenting 👍🏻

  • @karenstein8261
    @karenstein8261 11 місяців тому +1

    With all due respect to the inspector, I believe the NEC may have been misapplied.
    The problem is with the use of the term "agricultural building." Your building looks like a simple garage / workshop. Such a building can use "Romex."
    "Agricultural building" is further defined by the code (NEC) as more than just a building used on a farm. Additional elements are required, such as washdown activities (and I'm not talking about washing your tractor), bulk handling of loose feed and fertilizer (dust and corrosion issues), the housing of animals, etc. The concerns center on corrosion (ammonia from waste) and physical damage (chewing).
    An agricultural building CAN use type "NMC" cable. This is an electrical unicorn -- no such cable exists. The equivalent cable is known as "UF," or underground feeder.

    • @JustinsProject
      @JustinsProject  11 місяців тому

      The permit pulled for the construction of the building stated it was an agriculture structure.

  • @dimitarpavlov3955
    @dimitarpavlov3955 Рік тому +1

    As none lincesed can you pull permit for high voltage permit as home owner or your permit is submitted by licensed contractor and you do the work?

    • @JustinsProject
      @JustinsProject  Рік тому

      Yes, if you are doing the work for yourself. It still needs to pass the electrical inspection and get final approval. Thanks for watching and commenting 👍🏻

  • @natewoi4119
    @natewoi4119 5 місяців тому +1

    DUDE YOU NEED TO GO TO HARBOR FRIGHT

    • @JustinsProject
      @JustinsProject  5 місяців тому

      Got one just down the street. Thanks

  • @patrickmorris9710
    @patrickmorris9710 10 місяців тому +1

    Some times you have to talk to the inspector and ask him what he wants to see, then build that way.

    • @JustinsProject
      @JustinsProject  10 місяців тому

      Definitely. Thanks for the tip! 👍🏻

  • @BVaughanfulk
    @BVaughanfulk 10 місяців тому +3

    Anywhere the romex would be exposed, you need to use MC or conduit. Now if you had thrown drywall or plywood over the romex. It would pass.
    And every separate building with a panel needs its own grounding system.

    • @JustinsProject
      @JustinsProject  10 місяців тому

      Thanks for watching and commenting 👍🏻

  • @billgatewood9578
    @billgatewood9578 2 роки тому +1

    Get a Roto Split tool for MC cable.

    • @JustinsProject
      @JustinsProject  2 роки тому

      Might have to try that. Thanks for watching and commenting 👍🏻

  • @chipdayton1625
    @chipdayton1625 2 роки тому +2

    Just a guess, but maybe the MC is required in an ag building because there could be animals in there.

    • @JustinsProject
      @JustinsProject  2 роки тому +2

      That's exactly what the inspector stated. I understand the concept and it needs to be built to last far beyond my ownership. The next guy might have cows or horses in there. Thanks for watching and commenting 👍🏻

  • @gilbertjaramillo8735
    @gilbertjaramillo8735 2 роки тому

    Aww you poor guy redoing all that work (especially the second ground rod) and extra expenses. You even sounded out of breath, so sorry, but I bet you swore like a sailor when you found out your inspection failed. I know I would have. Rework and extra expenses are never good thing. Great video. I also added a 9.87kW solar system to my shop but fortunately out here in my area we do not need county inspections.

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      Never again will I hand drive a ground rod lol Thanks for watching and commenting 👍🏻

    • @gilbertjaramillo8735
      @gilbertjaramillo8735 2 роки тому

      Don't blame you. I drove one in myself and was tuckered out.

  • @robertbarlow5075
    @robertbarlow5075 Рік тому +1

    Nice job

  • @thomasmarable6818
    @thomasmarable6818 2 роки тому +1

    I thought it was a 100 amps if so you #8 was ok. The 2 ground rod rule on a out building go by AHJ. Most dont understand what that rod is for.

    • @JustinsProject
      @JustinsProject  2 роки тому

      It was 100 amp sub but they told me #6 ground was required. Not terrible fix but it was something that I had to fix though. Thanks for watching and commenting 👍🏻

    • @charles-hu8ru
      @charles-hu8ru 2 роки тому

      #6 is the minimum for the grounding electrode conductor. For a 100 amp circuit a #8 equipment ground would be fine. I believe
      Nec 250-64 and 250-122.

  • @jasperjones6962
    @jasperjones6962 8 місяців тому +1

    We don't have any electrical inspections around here.

    • @JustinsProject
      @JustinsProject  8 місяців тому

      Thanks for watching and commenting 👍🏻

  • @tracker1ify
    @tracker1ify 2 місяці тому +1

    Considering you coming from your house off the power why even get a permit? Just asking.. i would of only got a permit if it was a separate meter

    • @JustinsProject
      @JustinsProject  2 місяці тому

      It's always best, especially if you are getting insurance on the structure. I don't want any excuses if something was to ever happen. 👍🏻

  • @roberthughes2665
    @roberthughes2665 Рік тому

    PVC conduit is super expensive these days. Not sure about the EMT? My pole barn uses Romex but not required to meet code here in the country where I live. I can see the issue with cutting one since not enclosing the wall

    • @JustinsProject
      @JustinsProject  Рік тому

      Thanks for watching and commenting 👍🏻

    • @roberthughes2665
      @roberthughes2665 Рік тому

      I liked your honesty and willingness to admit mistakes. Keep it real 😜. We are all human. When I said I live in the country I didn't mean a foreign country just out in the country. Smack dab in the middle of the USA.

  • @karenstein8261
    @karenstein8261 11 місяців тому +1

    "Two ground rods" is . . . unfortunate. You would have met the requirement -- and in a better way -- had you placed twenty feet of #4 copper within your concrete slab, clamping it to your rebar or mesh.
    I shudder at driving rods with a little maul as you did. Thank heaven your soil is soft. I commend your aim and patience. Post drivers are cheap, or you could have rented an SDS-Max roto-hammer to do the job. (Battery powered roto-hammers exist).

  • @johndavies2949
    @johndavies2949 Рік тому +1

    So what it is is being corrosion resistant. Type NM which you had to take out isn't. Type NMC is. If you can get it. MC cable isn't. Vinal coated like you had to buy is.

  • @HarryVonhoene
    @HarryVonhoene Рік тому +1

    Do you have a hammer drill? Makes driving a ground rod a lot easier!

    • @JustinsProject
      @JustinsProject  Рік тому

      I didn't have the bit but should have bought one 🤣 Thanks for watching and commenting 👍🏻

  • @Dixler683
    @Dixler683 Рік тому +1

    Very good video.

  • @johngrubbs9444
    @johngrubbs9444 2 роки тому +3

    If this is an AG structure then it should AG exempt from the building code, which doesn't require inspections. Not sure what state this is in but in the Old Dominion that's how we roll.

    • @JustinsProject
      @JustinsProject  2 роки тому +1

      Inspection was required by the county even though it was an AG permitted structure. Thanks for watching and commenting 👍🏻

    • @keithharrington8715
      @keithharrington8715 2 роки тому +2

      The electrical building code (NEC) has a section 90.4 that allows different places to completely ignore it if they want.
      The agricutural building section is set up to be an umbrella type section to cover animal storage.
      A grounding section for cattle/pigs.
      An electrical system protection section because bird/chicken poop may corrode the wires into a fire.
      A dust section because some fish feed or plants may create flammable dust floating in your building.
      I do not live in a farming community so my knowledge is limited here. Just be safe. Someone had to create a situation and suffer in order to get a special rule in the building codes.

  • @joemaldonado3
    @joemaldonado3 Рік тому

    corrosion is a real threat to electrics in barns and such. weather proofing inside is a plus....

    • @JustinsProject
      @JustinsProject  Рік тому +1

      True, I have been working on finishing the interior of the shop. What a job for one guy. Thanks for watching and commenting 👍🏻

    • @joemaldonado3
      @joemaldonado3 Рік тому

      @@JustinsProject sure, my pleasure.

  • @Pr3lude9
    @Pr3lude9 9 місяців тому +1

    Why would you need a second ground rod at the sun panel?

    • @JustinsProject
      @JustinsProject  9 місяців тому

      The inspector required me to install it to pass

    • @Pr3lude9
      @Pr3lude9 9 місяців тому

      @@JustinsProject I’m not an electrician, but maybe if the sub panel is in a speedster structure, it needs its own rod. But a sub panel still in the same structure as the main does not. Someone please correct me if I’m wrong.

  • @cgschow1971
    @cgschow1971 10 місяців тому +1

    Bottom line is NM cable is not rated for exterior applications and an agricultural building is unheated, damp, and corrosive. UF cable is fine. Kinda surprised if standard MC cable (also interior) passes. That spiral jacket can corrode. The NEC doesn't care what you are actually using the building for, but what it's designated as.

    • @JustinsProject
      @JustinsProject  10 місяців тому

      That's exactly what the inspector said. Thanks for watching and commenting 👍🏻

  • @paulshuppert4975
    @paulshuppert4975 11 місяців тому +1

    Pour water in the hole with the rod🎉

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Thanks for watching and commenting 👍🏻

  • @sheilaashley
    @sheilaashley 2 роки тому +1

    That electrorode was hard!

    • @JustinsProject
      @JustinsProject  2 роки тому

      With a 🔨 its a workout for sure. But, it can be done.

  • @edwinsGT8866
    @edwinsGT8866 2 роки тому +5

    Call your inspector back and tell him your switch box is too small by .5 cu. inch. Surface mounted devices require unbreakable cover plates. Nice job for a non pro.

    • @JustinsProject
      @JustinsProject  2 роки тому +3

      🤣 Thanks! That's funny because I actually bought metal covers and had them on hand, just incase. 😁 Thanks for watching and commenting 👍🏻

  • @joewinkler2168
    @joewinkler2168 11 місяців тому +1

    Your 1st grounding rod needs to be 4ft. From the structure, then 2nd needs to be 4ft. From the first one, going away from structure.

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Thanks for watching and commenting 👍🏻

  • @1patrickx
    @1patrickx Рік тому

    Your jurisdiction must have some amendments. I’m fortunate that I can use NFPA70 2017, 2020, or 2023 as so I desire. Most of my state have no additional amendments and allow us to follow the NEC NFPA70.
    In 2017 NFPA70 (334.10)(1) covers attached and detached garages and storage buildings. Except as prohibited by (334.12).
    334.10(A) Allows for NM cable to be exposed or concealed, unless your building was not classified under (334.10)(1) than it would be prohibited by (334.10)(3) which would require a 15minute flash rating. However, I would argue that this building would be under (334.10)(1) as a detached garage.
    As long as your building doesn’t fall under (334.12)(A)10 hazardous classified location, or (334.12)(B)(1 and 4) exposed to corrosive fumes or vapors. Or considered a wet or damp location. You should be able to proceed with NM Cable.
    (334.15)(B) Exposed Work and Protection from physical damage. NM cable that is subject to physical damage has to be protected by RMC, IMC, EMT, or Schedule 80 PVC. You may also use RTRC marked with suffix -xw.
    So if NM had to be in walls, (334.15) wouldn’t exist.
    By the way MC or Metal Clad would be prohibited by the NEC NFPA70. In the 2017 version (330.12)(1) Prohibits the use of MC where exposed to physical damage, and there is no remedy allowed , such as running the MC through conduit. The 2020 and 2023 versions still prohibit using MC when exposed to physical damage.
    Seems the AHJ told you to do something that is prohibited by the NEC. Assuming the AHJ told you to use MC Cable!!

    • @JustinsProject
      @JustinsProject  Рік тому

      My jurisdiction does what it wants 😁 Thanks for watching and commenting 👍🏻

  • @kllisk
    @kllisk Рік тому

    How did you get that ground clamp undone I am pretty sure the bolts torque off ot the proper torque?

    • @JustinsProject
      @JustinsProject  Рік тому

      I'm not sure I follow. Thanks for watching and commenting 👍🏻

    • @kllisk
      @kllisk Рік тому

      @@JustinsProject those clamps are made so that you tighten until the head twisted and that is how you know and any inspector knows it was properly torqued.

  • @darrinburkowske5162
    @darrinburkowske5162 2 роки тому +2

    Inspector must have stock in electric wire.

    • @JustinsProject
      @JustinsProject  2 роки тому

      🤣 I wish I invested in copper a couple years back.

  • @danielmalack3714
    @danielmalack3714 11 місяців тому

    Why do you come out of the top of the panel and go to a device under the panel?

  • @mrcryptozoic817
    @mrcryptozoic817 Рік тому +1

    Good thing there is an MC rule. Maybe not you, but frequently there is a rodent risk in these work structures.

    • @JustinsProject
      @JustinsProject  Рік тому

      True. Thanks for watching and commenting 👍🏻

  • @barrylitchfield8357
    @barrylitchfield8357 Рік тому +1

    Only the left channel of your audio is working. 😮

    • @JustinsProject
      @JustinsProject  Рік тому

      Yeah, that was a technical problem with my old microphones. I got those updated just shortly after the release of this video. My apologies. Thanks for watching and commenting! 👍

  • @jenniferneumann716
    @jenniferneumann716 Рік тому

    Licensed Journeyman electrician in Michigan I would challenge the ground rods and wire as that panel is a load center, not a main panel. A load center is fed too via the main panel ( 220/240 volt ) with two feed one neutral and the ground wire all grounding is to be done through the main panel that is why you have neutrals on one bar the grounds on the bar mounted to the box and the bonding screw removed. Lastly emt and metal boxes definitely a great way to go

    • @JustinsProject
      @JustinsProject  Рік тому

      Thanks for the information! Thanks for watching and commenting 👍🏻

    • @MrSummitville
      @MrSummitville Рік тому

      Per NEC ... the ground rods are required for the separate building.

  • @TedTedness
    @TedTedness 2 місяці тому

    ANY exposed wire like romex is a no no. Can't use it below foor joist in a basement in residential or anywhere in a garage unless behind drywall in residential and in your case in AG building everything needs to be protected MC or conduit.

  • @Harrison2253
    @Harrison2253 Рік тому +1

    get yourself a Hilti TE 70 with an SDS Max ground rod adapter

  • @Golden-69
    @Golden-69 Рік тому +1

    Use water put the ground rod in, much easier. Never have to use a hammer.

    • @JustinsProject
      @JustinsProject  Рік тому

      Awesome, thanks for watching and commenting 👍🏻

  • @solharvester2341
    @solharvester2341 11 місяців тому

    What's the problem with the Romex?

    • @JustinsProject
      @JustinsProject  11 місяців тому

      Thanks for watching and commenting 👍🏻