How To Hide TV Power Cord And Cables! No Outlet Wiring Needed! EASY DIY!

Поділитися
Вставка
  • Опубліковано 7 чер 2024
  • ITEMS I USED ON THIS VIDEO:
    - TV Cable Management Kit - amzn.to/4cZskwj
    - 42-86” TV Mount - amzn.to/3TXoT0f
    - 6” Drywall Jab Saw - amzn.to/3xCwyK4
    - Franklin Stud Finder - amzn.to/49AeBcc
    - KLEIN Tools Fish Tape - amzn.to/3JiIGCv
    - Wire Strippers - amzn.to/3Q34OVj
    - 1” Masking Tape - amzn.to/3Q1DQxd
    - Drill With Bit FULL Kit - amzn.to/3xAyMcL
    JOIN THIS CHANNEL to get access to PERKS! :
    / @fixthishouse
    SHOP MY OFFICIAL FIX THIS HOUSE WEBSITE! : www.fixthishouse.net
    SHOP MY ONLINE AMAZON STORE AND CHECK OUT ALL THE TOOLS I USE! www.amazon.com/shop/genevo9
    ☕️ Buy me a coffee 🙏🏽! This will greatly help support this channel and will allow me to help more People by creating more helpful and useful How To, DIY & Product Review videos! :
    www.buymeacoffee.com/fixthish...
    On this video I will be showing you How To Hide TV Power Cord And Cables! No Outlet Wiring Needed! EASY DIY!
    Please Subscribe To Our Channel! / fixthishouse
    FOR BUSINESS INQUIRES SEND TO:
    FIX THIS HOUSE
    P.O. BOX 2511
    BREMERTON, WA 98310
    UNITED STATES
    FOR BUSINESS INQUIRES EMAIL ME AT:
    fixthishouse1@yahoo.com
    DO YOU HAVE QUESTIONS ON YOUR HOME REPAIR OR DIY PROJECT? GET TIPS, ADVICE AND ANSWERS! BECOME A FIX THIS HOUSE MEMBER!
    Become a FIX THIS HOUSE Member by clicking on this link: / fixthishouse
    DISCLAIMER:
    This video is meant for informational, educational, and entertainment purposes only! To better your knowledge on the concepts of electricity, electrical circuitry, entertainment component circuitry and all other wiring methods. Electrical codes in my area may be different from yours so always make sure you follow and stay current with your local code. With different codes around the world constantly changing standards, regulations and rules, it is the sole responsibility of the viewer to educate themselves on their local requirements before undertaking any sort of project. That being said Fix This House cannot claim liability with all applicable laws, rules, codes and regulation for a project. DO NOT ATTEMPT ANY WIRING OF ANY KIND if you lack the knowledge and understanding required. Otherwise, personal injury and/or death as well as property damage or loss could occur. Your safety is your own responsibility, including proper use of equipment and safety gear, and determining whether you have adequate skill and experience. If you are a younger person or are inexperienced with electrical devices, ask for help from a parent, teacher or a licensed professional.
    WARNING- Electricity is dangerous and can cause personal injury or DEATH as well as other property loss or damage if not used or constructed properly. If you have any doubts whatsoever about performing do-it-yourself electrical work, PLEASE do the smart thing and hire a qualified and licensed electrician to perform the work for you.NEVER WORK WITH LIVE VOLTAGE. Always disconnect the power source before working with electrical circuits.When performing electrical work, ALWAYS READ AND FOLLOW THE MANUFACTURERS INSTRUCTIONS AND SAFETY GUIDELINES. Always follow your local electrical code and requirements which are specific to local areas.By utilizing this video and the information given, YOU are expressly holding "FIX THIS HOUSE" HARMLESS FOR ANY PROPERTY DAMAGE, PERSONAL INJURY AND/OR DEATH, OR ANY OTHER LOSS OR DAMAGE THAT MAY RESULT FROM YOUR ACTIONS. Viewers must be aware by doing projects on their homes they are doing it at their own risk and Fix This House cannot be held liable if they cause any damage to their homes. Fix This House and all parties associated with it ARE NOT responsible for the use and results of this information by any party, especially those lacking sufficient skill or knowledge to perform these steps safely and ANY HAZARD CREATED IS THE SOLE RESPONSIBILITY OF THE USER.
    DISCLAIMER: This video contains affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.
    #electrical #outlet #diy
  • Навчання та стиль

КОМЕНТАРІ • 44

  • @FixThisHouse
    @FixThisHouse  Місяць тому +3

    ITEMS I USED ON THIS VIDEO:
    - TV Cable Management Kit - amzn.to/4cZskwj
    - 42-86” TV Mount - amzn.to/3TXoT0f
    - 6” Drywall Jab Saw - amzn.to/3xCwyK4
    - Franklin Stud Finder - amzn.to/49AeBcc
    - KLEIN Tools Fish Tape - amzn.to/3JiIGCv
    - Wire Strippers - amzn.to/3Q34OVj
    - 1” Masking Tape - amzn.to/3Q1DQxd
    - Drill With Bit FULL Kit - amzn.to/3xAyMcL

  • @AuralayKristine
    @AuralayKristine Місяць тому +3

    I've recently discovered this channel and it's been such a huge help! I've already done some work fixing the garage door weather trim, caulking new baseboard, and using the miter saw to cut trim for an entire room, all with these videos as my companion and guide. Thanks for making it so easy to follow for beginners and explaining how and why to do things! My house is improving so much and I'm feeling less intimidated by the work it still needs.

    • @rea8755
      @rea8755 Місяць тому

      Well it's about time. Just kidding Peace

  • @jacqjacq5920
    @jacqjacq5920 Місяць тому +2

    You make things look so easy! Thank you!

  • @frankbrowning328
    @frankbrowning328 Місяць тому +3

    Great video demonstation! Looks nice and clean.

  • @ronm6585
    @ronm6585 Місяць тому +1

    Nice! Thanks.

  • @proudtexan5513
    @proudtexan5513 Місяць тому +1

    Awesome video!! thank you!

    • @FixThisHouse
      @FixThisHouse  Місяць тому

      I’m glad I could be of help! 👍🏽😊

  • @kimberlymcmillian2440
    @kimberlymcmillian2440 Місяць тому

    Would love to see a video with power source being 12-3 split receptacle added to another receptacle with 12-2 . Just watched your video on the spilt outlet connected to a light switch. Is receptacle to another receptacle the same concept? Love your videos. You explain everything very well. I have learned a lot from you. Thank you.

  • @PatrickEArchuleta-fs8bv
    @PatrickEArchuleta-fs8bv Місяць тому

    Wago connector's way better.god bless you for your time on these videos.

  • @yeroca
    @yeroca Місяць тому +1

    Does the NEC 2023 permit this, what feels like, temporary wiring?

    • @rea8755
      @rea8755 Місяць тому

      What's a little fire😂?

    • @yeroca
      @yeroca Місяць тому +2

      @@rea8755 I did look into NEC 2024 handbook, and there does't seem to be any restriction on using power inlets, so as long as the wiring and connectors can all handle the rated load, it shouldn't present a fire hazard.
      I did read some 1-star reviews of the suggested product, though, and many people complained that cutout template is wrong, and that the connectors are flimsy and failed easily, so buyer beware.

  • @Digital-Dan
    @Digital-Dan Місяць тому +1

    My walls tend to have firebreaks. Makes all this much more difficult.

    • @timthomson7532
      @timthomson7532 Місяць тому

      There is a special long auger bit you can get that will reach about 48” that you can use to penetrate through the fire lock without cutting a big hole in your wall. Lowe’s or Home Depot carries it in the electrical isle

  • @LordHog
    @LordHog Місяць тому

    So, what about if one encounters a fire brake where the outlet is installed? Should one be looking to ensure a fire brake isn’t blocking the path?

    • @timfuscaldo3024
      @timfuscaldo3024 Місяць тому

      Then you put a hole in the rock and drill through the fire break. Then you repair the rock. Simple as that. More expensive, it is a matter of what you want to deal with to hide the power cord. I would also take power from the outlet already there and run it up the wall, one less box. Quite simple to do, not sure why this solution is even considered.

    • @timthomson7532
      @timthomson7532 Місяць тому

      There are special long auger bits designed to penetrate any fire block if it is within the bits reach which is about 48 or so inches. Is is a bit tricky finding that hole later but doable. Most home improvement centers like Lowe’s or Home Depot carry this tool. A fish tape helps as well. Like Tim said earlier, easier to use the original outlet if it is in the right spot under the new top outlet location, just widen the lower hole for the low volt cables to pass through

  • @timfuscaldo3024
    @timfuscaldo3024 Місяць тому +3

    The right solution is to run the power up and in the wall from the existing box to a new outlet behind the TV. The solution presented in this video makes no sense to me one less box, and the box behind the TV would be smaller. And if one can handle what is presented in this video, they could handle what I am suggesting.

    • @timthomson7532
      @timthomson7532 Місяць тому

      That is true if the top outlet location is in the same cell as the feeder outlet, but older houses have fewer outlets and may not have one in the area you plan on mounting the tv. This is a good DIY option for one of those installs.

    • @jaypee07747
      @jaypee07747 Місяць тому

      Also, this option doesn't require repairing dry wall after installing boxes.

  • @genehammond7239
    @genehammond7239 Місяць тому

    👍👍👍

  • @FRJ1982
    @FRJ1982 Місяць тому +1

    How easy is it to fish the wire

    • @FixThisHouse
      @FixThisHouse  Місяць тому +1

      Took less than 1 minute, trial and error.

  • @veramae4098
    @veramae4098 Місяць тому +1

    I don't understand. Are you connecting the new outlet to power or not?

    • @FixThisHouse
      @FixThisHouse  Місяць тому +1

      No, you are making electrical extension which connects to the main outlet power with an extension cord.

    • @LessThanHandy
      @LessThanHandy Місяць тому

      That white extension cord will provide power to the new outlet he installed that goes up the wall where the tv was connected.

  • @babzkumar3409
    @babzkumar3409 Місяць тому

    Try doing this on the brick

    • @timfuscaldo3024
      @timfuscaldo3024 Місяць тому

      If you got brick, then you are shit out of luck. need to run a piece of Trim up to the TV that hides the wire.

    • @timthomson7532
      @timthomson7532 Місяць тому

      You can cut and chisel out the mortar between the bricks and run the Romex in the channel. It’s a pita, but doable. Make sure you get a good long HDMI cable and keep it in a separate groove away from the Romex.

  • @CScones
    @CScones Місяць тому

    Does this do any kind of surge protection? Or would you potentially need to go from the outlet > surge protector > outlet?
    It does look like they offer a surge protector version for $70 more.. Not sure if that's worth it versus doing a stand alone surge protector.

    • @timthomson7532
      @timthomson7532 Місяць тому

      I’d get a stand alone surge protector in case of failure it would be easier to replace

  • @hammerridecycling7630
    @hammerridecycling7630 Місяць тому +3

    or just wire it out to the existing outlet?that extention cord man😳

    • @FixThisHouse
      @FixThisHouse  Місяць тому +1

      Then you’ll have an exposed wire going down?

    • @user-bo1rj2xu2s
      @user-bo1rj2xu2s Місяць тому +1

      Only if you are okay with that "wires, wires, everywhere" look. This is a cleaner, neater look and appears pretty easy to do.

    • @hammerridecycling7630
      @hammerridecycling7630 Місяць тому

      @@FixThisHouse just like adding an outlet but just vertical

    • @timthomson7532
      @timthomson7532 Місяць тому

      @@hammerridecycling7630you would still have to have a place to run the low volt cables. They do make special wall plates designed for it though.

  • @PatrickEArchuleta-fs8bv
    @PatrickEArchuleta-fs8bv Місяць тому +1

    Multi tool is much safer

  • @carryjurek2019
    @carryjurek2019 Місяць тому

    Not code compliant

  • @rickrude9523
    @rickrude9523 Місяць тому

    I am thoroughly confused at what I just watched. If you're fishing a wire up a wall, and your splicing the inlet, then why wouldn't you just wire the receptacle behind the TV without the need for the inlet? Also, any time you add a new outlet to any exist circuitry, then you must by code, protect that circuit with an arc fault circuit interrupter.

    • @timthomson7532
      @timthomson7532 Місяць тому

      It’s basically an extension cord hidden in the wall, but you could call the building department and ask if it’s ok to use this kit without a permit

  • @riverpirate1022
    @riverpirate1022 Місяць тому

    You installed the wall box upside down, on both top and bottom /facepalm.
    All you really did was move the cords mess down to the floor where the normal wall power boxes are.
    If your capable of cutting drywall and doing all this, your capable of just doing it right and adding the proper power box behind the TV without this work around to plug this box into another normal power outlet, which I doubt is legal for building codes.
    Kids, don't follow this poor example video, if your not skilled in these installations hire a professional so you don't burn down your house or void your home insurance using non approved electrical systems.

    • @timthomson7532
      @timthomson7532 Місяць тому

      I agree, but if the bottom power feeding outlet was on a different wall this would be a good DIY get around. You would still need to add a couple holes for the low volt cable(s). Wiremold is an alternative as well, cleaner, but still ugly