GAS BOILER SEQUENCE OF OPERATION PART 2, how gas boilers work, how to fault find on gas boilers.

Поділитися
Вставка
  • Опубліковано 27 гру 2024

КОМЕНТАРІ • 60

  • @josealbertorodriguez3297
    @josealbertorodriguez3297 Рік тому

    Hi , Im from Spain. I just finished a course of technissian of gas, I dont understood many things in my country because my teachers and thanks to you and your videos I learn too much,finally I understood many stuff. Sorry for my English I dont practiquese too much. Thanks thanks thanks thanks. Take care. You're the BEST.

  • @tonywardell3411
    @tonywardell3411 3 роки тому +1

    Best video I’ve seen on UA-cam explaining faults. Thanks derek 👏👏

  • @azimkhan9862
    @azimkhan9862 3 роки тому +1

    Dear Derek, your work is much appreciated and I'm sure will be used by many up and coming future gas engineers.

  • @andreilapo1973
    @andreilapo1973 Рік тому

    Best trainer out there 100%. Thank you

  • @willlomas2725
    @willlomas2725 Рік тому

    Thank you Derek...fantastic video.

  • @matthewsavory5037
    @matthewsavory5037 2 роки тому

    Great job thank you. I'm just getting back into boilers after a long stint meter fitting . Great refreshers these videos

  • @emekaABC
    @emekaABC 3 роки тому

    .......another master class from Derek, again ...well done !!

  • @mj0n4id36
    @mj0n4id36 3 роки тому

    Very useful. Will be watching this one a few times just to get my head around it. Thanks Derek much appreciated 👍🏻
    Asian Jon. Training.

  • @mohammednadeem7274
    @mohammednadeem7274 3 роки тому

    Another brilliant video Derek, very useful for us. Thanks 👍👍😀

  • @dannymatona3506
    @dannymatona3506 2 роки тому

    Thanks for another informative excellent helpful vid.

  • @williamhoughton1484
    @williamhoughton1484 2 роки тому

    Fantastic video Derek 😊👍

  • @kelvinjones1995
    @kelvinjones1995 3 роки тому

    Really informative,thanks Derek,old dogs can learn new tricks!

  • @shannonharris7126
    @shannonharris7126 3 роки тому

    Hi derek,another great video.keep up the good work😎👍

  • @MSKChess
    @MSKChess 3 роки тому

    Sometimes the low water pressure switch, high limit stats etc are daisy chained together, is it not the case?

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому

      Some do some don’t like I say not every boiler is the same

    • @MSKChess
      @MSKChess 3 роки тому

      @@tomkatgastrainingLolz in other words READ THE MI you lazy bum engineers! XD

  • @stewartharrod1706
    @stewartharrod1706 2 роки тому

    Awesome video 💯💯💯

  • @ahmaddarwiche9154
    @ahmaddarwiche9154 3 роки тому

    Thanks for very good information and fault finding

  • @dannymatona3506
    @dannymatona3506 3 роки тому

    Another excellent vid. Thankyou

  • @leonardbalint4930
    @leonardbalint4930 3 роки тому

    thank you very much for your effort , very informative, really appreciate it

  • @pookievision
    @pookievision 2 роки тому

    Find myself learning theory and sequence yet when im in the customers house it all goes out the window...put idea for vids in part 3 👍

  • @groovejet33
    @groovejet33 3 роки тому

    One thing I don't get?
    The first part of sequence of operation is pump on and flow sensed? So why does ignition sequence start?
    Obviously the pump doesn't disable or interupt the ignition sequence?

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому

      Low water dose but pump not running doesn’t

    • @whynot6950
      @whynot6950 3 роки тому +1

      It must send power to both pump and pressure sensor at the same time but only pressure sensor is essentially the switch to continue the sequence. My theory is firing dry could crack heat exchanger but firing wet with no circulation just causes stat to lock boiler out. Forgive me if I’m mistaken but the pressure sensor is just confirming the system is full of water not confirming circulation/flow and that pump is working.

    • @groovejet33
      @groovejet33 3 роки тому

      @@whynot6950 makes sense, thanks m8

    • @snigie
      @snigie 3 роки тому

      There is not flow sensor/pump proving on this boiler. The boiler relies on over heating if the pump is faulty and basically gives a dry fire fault (pressure sensor fault)

  • @AnEyeScream
    @AnEyeScream 2 роки тому

    Thank you, Nikola Ditsov

  • @jamalamin082
    @jamalamin082 3 роки тому

    Amazing vid once again 💯🔥🔥

  • @johnf3326
    @johnf3326 2 роки тому

    I was waiting for a combination of buggerations that would make it go BANG! 🤣

  • @leewalters6467
    @leewalters6467 2 роки тому

    If I give it a thumbs up twice will it give this a boost Big D? 😆

  • @Benji-gq9gx
    @Benji-gq9gx 6 місяців тому

    Why is the fault "water pressure" when you disconnected the pump?

    • @tomkatgastraining
      @tomkatgastraining  6 місяців тому

      Because the boilers low water pressure switch is only a switch that does high and low pressure and not no flow

    • @Benji-gq9gx
      @Benji-gq9gx 6 місяців тому

      @@tomkatgastraining so is it because when the pump isn't working the heat builds up and this causes the water pressure fault?

    • @tomkatgastraining
      @tomkatgastraining  6 місяців тому

      @@Benji-gq9gx in this boiler but some do have a pump proving as part of the low water pressure switch

    • @Benji-gq9gx
      @Benji-gq9gx 6 місяців тому

      @@tomkatgastraining so if they have pump proving I imagine the fault code would actually be "pump not working" or similar rather than showing a water pressure fault?

    • @tomkatgastraining
      @tomkatgastraining  6 місяців тому +1

      @@Benji-gq9gx correct

  • @monikanader9454
    @monikanader9454 3 роки тому

    Thank you👍👍👍

  • @MrReza21azer
    @MrReza21azer 3 роки тому

    Excellent 👌👌👌👌🔥

  • @simonmadahar5463
    @simonmadahar5463 3 роки тому

    Could you do the same thing on a modern boiler?

  • @icetin7568
    @icetin7568 3 роки тому

    great information many thanks

  • @emmanueljouille7012
    @emmanueljouille7012 3 роки тому

    very very good

  • @ElTelBaby
    @ElTelBaby 3 роки тому +1

    It would B GR8 if U went through different Boilers Manufactures Faults...
    Starting with my Parents Boiler a Flexicom 24 HX
    In particular the BAD Design of the Fan Mounting;... (take NOTE U Boiler disgners) that inhibits the Fan from reaching full speed;... making a noise;... then causing either F22;... F25 that does NOT reset after a short delay...
    Where their system that runs on Constant;... for Old Ages occupants...
    It would B GR8 if someone came up with a Auto Reset because on a manual reset once sorts it out;... for Weeks;... Months... But on the 1st fault;... in the meantime their Bungalow has gone cold...

  • @simonmadahar5463
    @simonmadahar5463 3 роки тому

    Awesome UA-cam video 👌🏽

  • @hatemmimouni7015
    @hatemmimouni7015 3 роки тому

    Thank you

  • @Needdeen99
    @Needdeen99 7 місяців тому

    Awesome

    • @Needdeen99
      @Needdeen99 7 місяців тому

      Is there a step by step guide you would suggest reading

  • @samchappell233
    @samchappell233 3 роки тому

    👍👍👍

  • @farukadam1696
    @farukadam1696 3 роки тому

    👍

  • @craighurst3599
    @craighurst3599 3 роки тому

    CH👍

  • @jon-paulward4580
    @jon-paulward4580 2 роки тому

    Jon-Paul Ward

  • @SuperWayneyb
    @SuperWayneyb 3 роки тому

    🤘🤓🤘

  • @steve250276
    @steve250276 Рік тому

    steve ward

  • @mikefahy4960
    @mikefahy4960 2 роки тому

    Mike Fahy

  • @michaelwilson7061
    @michaelwilson7061 2 роки тому

    bonehead truckers theme

  • @joaovittoria2533
    @joaovittoria2533 3 роки тому

    👍👍