How to use a flue gas analyser and understand the results PART 1

Поділитися
Вставка
  • Опубліковано 5 жов 2024

КОМЕНТАРІ • 143

  • @Chewman30
    @Chewman30 3 роки тому +6

    I’m renewing my gas certs, I’ve been out of the gas industry for around 3 years, all of your information is on point and easy to understand 👍🏻

  • @southeastgasservices
    @southeastgasservices Рік тому +1

    Just had an Anton pro 1 delivered from Hamiltons today, upgrading from my old Anton, this will be my third Anton at this stage. We're not in a race indeed, I'm certainly not, headin' for 70 and still installing/servicing/repairing boilers. A very informative vidoe. cheers mate.

  • @tulipmonnty1875
    @tulipmonnty1875 2 роки тому +3

    I'm a gas tutor too and I love your videos. Thank you for producing such great content. Please keep going Derek, you're the best on UA-cam.

  • @fredrayers1735
    @fredrayers1735 3 роки тому

    An superb explanation of both how to use an analyser.

  • @joseph_donovan
    @joseph_donovan 4 роки тому +3

    Top tips from a top engineer! Fascinating video with features to please chemists, mathematicians and engineers. Love it! Learned so much. Thank you Derek!

  • @andyrichards4802
    @andyrichards4802 4 роки тому +4

    I've only been qualified for about a month, I always refer to manufactures.
    I was taught be Anton and love it, but my employer uses the Kane.
    Great video, great reminder of carrying out combustion analysis.
    Thanks and keep up the great work, looking forward to Parts 2&3.

  • @renearnhold552
    @renearnhold552 3 роки тому +1

    Thanks for your videos. I just study gas save engineer and through covid we didn't could learn so much as normal regards we where not allowed to go to college and my house move made it much more difficult to learn because I couldn't turn up to the online meetings. With your videos I can catch up very well. Thanks again

  • @nyahbinghi437
    @nyahbinghi437 4 роки тому +2

    Thank you so much for all the videos you put up,it's been a great help especially for those of us who have struggled.

  • @andrewthomas332
    @andrewthomas332 4 роки тому +1

    Superb Video Derek. The results from the FGA are finally meaning something to me now. much appreciated Andy Thomas Trainee

  • @mohammednadeem7274
    @mohammednadeem7274 3 роки тому

    Excellent video Derek I understand it better now compared to 1 year ago when I watched it, After getting your training and watching your videos you making us professionals. Thanks 👍👍😀😁👌

  • @antonyperry9585
    @antonyperry9585 4 роки тому

    You are the first person I have seen do a sweep test

  • @aidensholeh3696
    @aidensholeh3696 4 роки тому +2

    This was an incredible teaching experience. I missed this section on the course I’m attending so this has bridged the gap. Thank you so much.

  • @abdulh63
    @abdulh63 4 роки тому

    By far the best channel out there. Great video!

  • @all4heatinggaslimited40
    @all4heatinggaslimited40 4 роки тому

    This the best I have seen on FGA

  • @michaelrose5040
    @michaelrose5040 4 роки тому +1

    These videos are absolutely brilliant, really well explained. Just going through my training now and these are invaluable to me. Thanks so much Derek keep them coming
    Mick

  • @saidhissoufi277
    @saidhissoufi277 3 роки тому +1

    Thank you Derek. Great teacher good at explaining and simplifying things

  • @billy882in1
    @billy882in1 Рік тому

    Thanks Derek for brilliant video, Explained in very details. Bilal M tomkat trainee.

  • @mgbroadsterJ
    @mgbroadsterJ 2 роки тому +2

    The boiler might get to temperature within the 15 mins . It can be a pain .

  • @peterdashey9323
    @peterdashey9323 4 роки тому

    Hi Derek, another easily to understand video from your good self, just one little comment and that is at 14:25 you stated that the Co2 was 5.2 when in fact you meant O2. I’m not being picky but when you are producing educational videos which relate to the safety of the public, you must make sure that you are being 100% accurate with you descriptions as some students may remember this information and use it in the field. Apart from that keep up the good work, we need more people like you to educate the new coming engineers.

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому

      Peter Dashey thanks for your comment when I make the videos I just film them in one shoot , when I make a mistake and it’s not clear that I have then I will put a comment on the video. In this case it is quite clear I have made a mistake but thanks again for your comment and watching the video cheers

  • @ashishpainel
    @ashishpainel 4 роки тому

    That’s a very easy to understand information. Great video buddy. Thank you 🙏🏼🙏🏼

  • @willlomas2725
    @willlomas2725 2 роки тому

    Fantastic video Derek cheers pal.

  • @mohammednadeem7274
    @mohammednadeem7274 4 роки тому

    Another great video, a lot of important and very useful information. I'll have to watch this video a few times for it to settle in the mind best way to understand the procedure. Excellent.. 👍👍
    Tomkat gas trainee.

  • @muhammadgill507
    @muhammadgill507 4 роки тому

    Excellent video thank you Derek
    Anton is the best.

  • @kymarland8956
    @kymarland8956 4 роки тому +3

    If Carlsberg did gas training need I say more, I'm lucky enough to be currently doing my training with Derek at TomKat.

  • @rickyzar9108
    @rickyzar9108 3 роки тому

    Your video is brilliant bro.All way respect ur hard work...

  • @poptumsaffi
    @poptumsaffi 4 роки тому

    Best video you have done mate. Keep up the great work you do.

  • @mohammednazir8307
    @mohammednazir8307 3 роки тому

    Hi Derek very good once again. Very well explained! 😁

  • @piotrmarchwacki3414
    @piotrmarchwacki3414 4 роки тому +1

    Very good explanation. Thanks Derek.
    Polish Peter - trainee at TomKat😀

  • @andrewtomlinson18
    @andrewtomlinson18 4 роки тому +1

    Thank you for your instructional video’s, your explanations are always easy to understand and very thorough, I am a gas safe engineer but mainly fit cookers, hobs and fires/removal of, do you do a short course where I can brush up on the carrying out landlord certifications ?.

  • @jezlucas3878
    @jezlucas3878 Рік тому

    Glad they still use the same menu as the older models

  • @joco5906
    @joco5906 Рік тому +1

    Hi Derek, great video as always. How do you keep the boiler running at maximum rate long enough to adjust the CO2 without it reaching temp or modulating.

  • @samchappell233
    @samchappell233 3 роки тому

    another brilliant lesson 👍

  • @alirezajamshidyfard8184
    @alirezajamshidyfard8184 3 роки тому

    Very goog derek well done.

  • @len5509
    @len5509 3 роки тому

    Thanks again all good Deggsy.

  • @stevo0861
    @stevo0861 3 місяці тому

    Great video. Just one question. Why bother with a flue integrity test with the boiler on min fire?

  • @johnnysingh418
    @johnnysingh418 4 роки тому

    Really enjoy all the videos' there's always something new to learn when you're doing gas. Love Tom's sense of humour .

  • @abandofbrotherslondon6410
    @abandofbrotherslondon6410 3 роки тому

    Great video!!!! Thanks for these.

  • @moulesanctuary
    @moulesanctuary 4 роки тому

    Great video .. I am learning alot

  • @nouraldeenjbawi7231
    @nouraldeenjbawi7231 Рік тому

    Hello Mr Derek
    Can you please talk about Tracing Gas Escapes and the method we should follow

  • @mj0n4id36
    @mj0n4id36 3 роки тому

    Brilliant video. You made it very easy to follow and understand for us beginners. Great tip at the end about doing the sweep test last and we’ll never forget to close the sample test point! Definitely going to take up that advice. From the top of your head can you recall the common boilers that have a chimney sweep mode? Thanks very much Derek 👍🏻
    Asian Jon. Training

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому +1

      All new boilers have to go into max and min now Jon and a lot of the older condensing boilers will still have a way of doing it for flue gas analysing 👍🏻

  • @rafiahmadzai9442
    @rafiahmadzai9442 3 роки тому

    Great explanation 👍good man

  • @aaronjoyce1980
    @aaronjoyce1980 4 роки тому

    Top vid.. nice one Derek 👍

  • @Bradwellify
    @Bradwellify 2 роки тому

    Thomas Bradwell
    Thanks Derek

  • @stevereynolds7375
    @stevereynolds7375 4 роки тому

    Great video as usual 👍

  • @raul835
    @raul835 2 роки тому

    Awesome vid

  • @chriscars3578
    @chriscars3578 4 роки тому

    Great video 👍👍

  • @grantmackenzie8616
    @grantmackenzie8616 3 роки тому

    Top man great for revision

  • @manjsingh6500
    @manjsingh6500 3 роки тому

    Enjoyed it 😊👍👍

  • @natbag1
    @natbag1 3 роки тому

    Brilliant.

  • @smalik695
    @smalik695 4 роки тому

    Very helpful 👍🏼👍🏼👍🏼

  • @markcain4710
    @markcain4710 3 роки тому

    Nice video that derek👍

  • @andymav3023
    @andymav3023 Рік тому

    Hi Derek great video ….will you always get some measure of CO in flue integrity checks ? I take it anything higher than 5 is a problem

  • @abuadammemon3968
    @abuadammemon3968 4 роки тому

    this teaching, explain really good. Bless you .

  • @MohammedAli-xh6zs
    @MohammedAli-xh6zs Рік тому

    Cheers boss Mohammed Ali

  • @sergd7885
    @sergd7885 2 роки тому

    have been watching your channel for a long time, I have baxi solo 2 pf the overheat lamp lights up and he does not want to turn on thanks for any help, pump ok work.

  • @davemac5896
    @davemac5896 2 роки тому

    Small but important point. The analyser should never be placed on the boiler case when taking full combustion test. Flue gas temperature. Gross minus ambient = net. By placing the analyser on case distorts the ambient temperature due to analyser measuring the case temperature instead of room ambient temperature.

  • @patrickbradley7191
    @patrickbradley7191 2 роки тому

    Will you do course on boiler installs at all for new entries into Gas?

  • @faridratni5665
    @faridratni5665 Рік тому

    Please if you get 1 or 2ppm on sweepts test is that ok or not? Please let me know 🙏 Thanks Excellent video

  • @propman1823
    @propman1823 4 роки тому

    hes so good

  • @paullyons4624
    @paullyons4624 4 роки тому

    Hi, where can the bluelyzer be purchased from? the website has no shop or prices. It’s almost as though they don’t want to sell them. Keep up the good work.

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому

      paul lyons if you ring them they can sort you out 👍🏻 thanks for watching cheers

  • @rzbor
    @rzbor Рік тому

    Whitch O2 and CO sensors applicable for Kane 400 or Kane 940 anyzers? Many thanks

  • @gearstil
    @gearstil Рік тому

    Hello, why low CO reading when there is low efficiency? CO is practically unburned fuel. Why noncondensing boiler have low CO readings?

  • @concorde508able
    @concorde508able 4 роки тому

    Amazing

  • @user-tr6ep3ey1q
    @user-tr6ep3ey1q 8 днів тому

    You legend

  • @Matteo-rs7nk
    @Matteo-rs7nk Рік тому

    Hi . I’m currently doing my ACS , I just want ask , what happened in situations where I cannot use the analyser because the flue point is inaccessible due wood frame or tight cupboard space ??
    How you dealing with this situation? ID or AR ?? 🤔🤔thanks

  • @slidetv8152
    @slidetv8152 4 роки тому

    Where in the regs does it say about condensing boiler being 0.004 and a non condensing being 0.008? I thought it was 0.004 for all appliances and 0.008 was a British Gas procedure applying to a boiler that's just been serviced.

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому +1

      Bs 7967 2015 gives the results on using a flue gas analyser. All appliances could have different readings most analyser come with a card with the results if you watch all my videos on using an analyser you will see the card

  • @arvinsohrabi4009
    @arvinsohrabi4009 4 роки тому

    Hey, thanks for good videos full of new knowledge, does this analyser show the results of CO or CO2 ‌‌on weight basis or molar basis?

  • @dermotfahy6828
    @dermotfahy6828 3 роки тому

    great video really helped me out wish i found you earlier

  • @Ali-eo9tx
    @Ali-eo9tx 3 роки тому

    Hi Derek, Is the co2 spec for this boiler not 10.0% +or Minus 0.2 ? you are at 9.1

  • @darrenpardoe2715
    @darrenpardoe2715 6 місяців тому

    Do you have anything on fga testing on a gas cooker

  • @saltnvinni1
    @saltnvinni1 2 роки тому

    What CO ppm is permitted during a sweep test?
    Thank you

  • @markrainford1219
    @markrainford1219 2 роки тому

    What causes a highly efficient appliance to produce more CO than a less efficient appliance, given that CO is a product of incomplete combustion?

    • @tomkatgastraining
      @tomkatgastraining  2 роки тому

      Because condensing boilers are not atmospheric and they use the fan to suck the gas in they produce incomplete combustion so more co is produced

  • @1Monaghan
    @1Monaghan 4 роки тому

    Great video. Can you do this test with the boiler casing off? I’ve seen comments saying it affects the test and causes oxygen to be taken from the room or is this nonsense? Maybe they mean with the combustion chamber open rather than the case or are all boilers different?

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому +1

      1Monaghan the manufacturer’s tell you 2 readings a lot of the time one with and without the case . So yes it can make a difference but you couldn’t adjust a zero gas valve without the cover off . You definitely can’t do flue integrity with the cover off that would be effected. Hope that help and thanks for watching cheers

  • @davidscott3292
    @davidscott3292 10 місяців тому

    Why does a more efficient boiler give a higher CO reading?

    • @tomkatgastraining
      @tomkatgastraining  10 місяців тому

      Because they are forced draft burners with no post air

  • @jezlucas3878
    @jezlucas3878 Рік тому

    Had so many troubles with kane
    I've got 2 machines and from new nothing but troubles .
    This afternoon got to buy a new one as both machines can't be trusted.

  • @gavinfrancis579
    @gavinfrancis579 4 роки тому

    Great video. I've not yet to get any 02 Readings of less than 20.9 anywhere . However did you get 20.6 ? Thx

    • @cliveramsbotty6077
      @cliveramsbotty6077 4 роки тому

      wave it around the room where you have an open flue appliance. or if your flue discharges into an alley way or something, go check out the ambient air

  • @woniiths
    @woniiths Рік тому

    10/9=1.11/10000 is it 0.00011 or 0.0011,anyway great video,best tutor

  • @Luke-yy1fq
    @Luke-yy1fq 2 роки тому

    Derek what if a reading of CO2 was higher than allowed tollerance in MI
    An engineer told me if can't adjust just note as NCS

    • @tomkatgastraining
      @tomkatgastraining  2 роки тому

      If the co2 is high and it takes the ratio over tolerance that would be classed as AR not NCS. You can try and adjust the zero governor gas vale as long as it’s your last hope after a full strip down service.

    • @Luke-yy1fq
      @Luke-yy1fq 2 роки тому

      @@tomkatgastraining no the ratio is fine under 0.004 just high co2 over mi Derek. Got told it's NCS in future

    • @tomkatgastraining
      @tomkatgastraining  2 роки тому

      @@Luke-yy1fq it’s the ratio that comes under unsafe situations not the co2. And yes most engineers won’t try and adjust if the ratio is ok because the heat exchanger will need cleaning if the co2 is incorrect.

  • @sodig876
    @sodig876 4 роки тому

    Great video thanks 👍
    I've recently got some new service / report pads one box asks for CO% would you get this on a flue sample test?

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому +1

      Is it asking for a room co % or with a ratio

    • @sodig876
      @sodig876 4 роки тому

      Tomkat Gas Training
      I presume it’s room CO % as there is a separate box for ratio, ppm, & CO2% etc.

  • @farobenz6144
    @farobenz6144 3 роки тому

    Flueless appliance - how do you find ratio?

  • @Luke-yy1fq
    @Luke-yy1fq 2 роки тому

    Hi Derek a reading of 0.0022 is usually high on a new boiler?

  • @chrisjones4500
    @chrisjones4500 2 роки тому

    👍👍

  • @sadeq48
    @sadeq48 3 роки тому

    Hello thanks for video I’m in weeks 3 gas training course and I’ll believe you are the number ☝️

  • @dw_plumbheat
    @dw_plumbheat 3 роки тому

    Do you find the tube from the probe on anton analysers becomes stiff over time? Mine is really rigid but I'm not sure if a new one will be any different...

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому +1

      Come to think about it yes they all go very rigid it’s not just Anton

  • @dugandav1
    @dugandav1 4 роки тому

    Great lesson - only undermined by the incessant background music which is unnecessary and distracting

  • @1Monaghan
    @1Monaghan 3 роки тому

    Is there any point in the NOx reading when doing domestic flue gas analysis?

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому +1

      Nope

    • @1Monaghan
      @1Monaghan 2 роки тому

      I’m looking at buying the Kane 458s cpa1 kit.
      I don’t think this FGA comes with an o2 measurement standard though and you need to pay an extra £450 for it do you think it’s better going for a different FGA because of this?

  • @marcinmasalski4183
    @marcinmasalski4183 2 роки тому

    Marcin Masalski 👍

  • @babworth1111
    @babworth1111 5 місяців тому

    Be awareed! Some numbers been changed..... I. E combination boiler reading

  • @mervinpermalloo8589
    @mervinpermalloo8589 Рік тому

    🙏👍

  • @jon-paulward4580
    @jon-paulward4580 Рік тому

    Jon-Paul Ward 👍

  • @jamalamin082
    @jamalamin082 4 роки тому

    👌🏽

  • @Ali-eo9tx
    @Ali-eo9tx 3 роки тому

    Sorry! Im working on these boilers on LPG Your probably using Natural Gas

  • @benhogan9030
    @benhogan9030 4 роки тому

    Watched 🙂 Ben Hogan - Currently Training ... 4 Adverts 🤬

  • @M20DAN
    @M20DAN 4 роки тому

    Tomkat👍🏻

  • @secondchance4498
    @secondchance4498 3 роки тому

    Chris taylor

  • @Heatingandplumbing1
    @Heatingandplumbing1 4 роки тому

    I prefer do flue integrity test before doing hi and low Combustion tests as the analyser has been freshly purged. Doing it the way in the video the analyser sensors are not clear from Combustion and more likely to miss any small co in the inlet flue.

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому

      HPE Heating and plumbing Engineer the analyser was purged back to zero and the o2 was at 20.9 so and the co doesn’t count in the integrity it’s the co2 and 02 . Thanks for watching and your comment cheers 👍🏻

    • @Heatingandplumbing1
      @Heatingandplumbing1 4 роки тому

      @@tomkatgastraining it makes it quicker to do the job doing the imtegrity first. As for co in the outer flue does matter as it shows the inner flue may be split or a whole in it.

    • @Heatingandplumbing1
      @Heatingandplumbing1 4 роки тому +1

      Good video, good tips

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому

      There are no results for co in any of the standards it only says about co2 of less than or equal to 0.2 and the o2 equal to or greater than 20.5 . I have found flues with holes in that read perfectly also but normally we get a very rusty boiler if the flue has gone lol . Thanks for your input it’s always a pleasure to talk to fellow engineers cheers

    • @rayc1503
      @rayc1503 4 роки тому

      @@Heatingandplumbing1 really doesn't matter which way around you do the flue integrity test as long as it's done. I prefer like most to do this 1st but many others do integrity after (mixed opinions). 😊

  • @steve250276
    @steve250276 Рік тому

    steve ward

  • @TheBhimaLogan
    @TheBhimaLogan 2 роки тому

    Bhima Logan

  • @natugrmaxion8337
    @natugrmaxion8337 4 роки тому

    Natnael

  • @marcinmasalski4183
    @marcinmasalski4183 2 роки тому

    Marcin Masalski