VISIT : www.learningtechnologyofficial.com ► For Civil Engineering Notes ► For Bar Bending Schedule Notes ► For Quantity Estimate Notes ► For Civil Engineering Experiments ► For Free IS Codes Download ► For Free Download Civil Engineering Apps ► For Civil Engineering Q n A Forum ► For Civil Engineering Books Store
Sir. This is very informative video. With practical. Thanks.... I have a doubt. At folded slab I didn't find any beam. Which connects to running beams. Doesn't it required?
Sir aap btaiye ki cover block bottom me kitna dena hai beam k size ke according 450mm beam or 250mm beam me kitna de or isme different bar me cover block kya kya hai
How do I make swimming pool on to my roof? What is its rod binding?& How do I seperate it's from roof. I want to need to learn heavy rod binding at different manner. Please help me.
sir i know stadpro software but not knowledge about its practical please give me suggestion and m try to many companies by mailing resume but no response please help
VISIT : www.learningtechnologyofficial.com
► For Civil Engineering Notes
► For Bar Bending Schedule Notes
► For Quantity Estimate Notes
► For Civil Engineering Experiments
► For Free IS Codes Download
► For Free Download Civil Engineering Apps
► For Civil Engineering Q n A Forum
► For Civil Engineering Books Store
Sir excavation related video bnayiyeee
Dear sir, you missed a point on spacer bar ...max. distance of spacers bar should be placed at a spacing of 1m ( IS 456 - pg - 26, clause- 12.3.2)
Yes, given
Sir aap ne civil engineer ko bahut acha sikhate ho
Sir apko bahot sari duayen...tysm for this knwlg....ur grt...hame ap jaise teacher ki jarurat a..sir....💞👍😊🇮🇳
This video is very useful for all of us..pls guys watch it..nd thanks a lot sir for making the video
I have a doubt in binding. Whether the bars of beam need to be tied to the bars of column in the junction
Very useful video sir. Ek point or apko batana chahiye. Lo ke bare me.
Sir expansion joint ki video bnao alag se briefly smjhne k liye
Thank u very much sir for your Engineering information
ap achha jankari dete hai
Thanks for the information. It will help non technical person to supervise their come construction site.
sir can you make a tutoreal about down slab detale please
Ok
12:48 What is lap length? And why is it used? I didn't understand anything about top lapping and bottom lapping here! What is it?
Sir all ways.iam belive your truth videos sir
Your lectures quality top class sir
Very good engr mukesh
Very good knowledge sir
WOW. You have almost clarify all the points. Thanks 😊👍 👌
Welcome
thank you soo much, sir
sir, please make a video on billing and total estimation of a building, sir.
A very Good video for Practical on field knowledge ......thanks a lot sir.👌🏻👏🏻👏🏻👏🏻👏🏻👍🏻
Welcome
Very super video for freshers✌️
In 10.14, please Elaborate how a Beam Reinforcement can be outside the Column??? (Edge of the downslab Beam)
Mast batate hain..aap
Well explained
Thank you sir 👏
thanks for the very very useful information & good explanation. keep rocking
Sir.
This is very informative video. With practical. Thanks....
I have a doubt.
At folded slab I didn't find any beam. Which connects to running beams.
Doesn't it required?
Beam is there...
Down slab is also called sunk slab
Sir balcony terrace p concrete casting s pehle sleeve dal sakte hai na sir slab me...k bhad me plumbing pipe jaa sake balcony k slab s
Sir extra top bar in end portion development length Kya hoga?
Very very helpful to us.. Sir thank You
Very Good, but where are the Tie Bars between the top and bottom of the Stirrups ?
thank you so much sir...
ak video column and slab k bare me bhi banadijiye pls...
Very impressive sir
good beam reinforcement bars positioning #
Sir Ye Kay construct Ho raha hai.. Residential or commercial building hai?
Residential
Very very nice. Thanks.
Bhut Khub samjaya aap n
sir can hidden beam be used as a secondary beam , please explain how and why or else.regards.
Very informative
Reinforcement ke neeche Jo bricks laga rakkhi h wo ese hi chhod Di jati h ya rcc ke time hata di jati h.
Bricks nahi h bhai... Wo cover block hai
Sir please staircase details video chahia
Making a video on shuttering material calculation
make a video also on column...
Grt job sir
Excellent video sir. Sir wat is the lapping location for slab...is it at middle or at its edge ?
Edge
@@LearningCivilTechnology Sir edge say itna distance chod ke....L/4 + 2D ?
Rare video and its amazing
Sir agar beam me lap dena pade to column jaha ata he uske bich me chalega junction me ?
Good
Sir aap btaiye ki cover block bottom me kitna dena hai beam k size ke according 450mm beam or 250mm beam me kitna de or isme different bar me cover block kya kya hai
Thik hai, thik hai
10mm agreegate our 20mm aggregate rahega to concrete ratio same rahega na ya sand ka ratio bada sakte hain kiya
why beam reinforcement is on top of the slab reinforcement at the explained location, does all slabs are one way or two way.
all slabs are - Down Slab
So flooring comes on top of the slab level or beam level?
top of slab
These are sunkun slab
Hello sir 1st floor me plan change karsakte hai ki nhi.....
Bohot shandar sir G 🙏
Thank you sir.
Stirrups ka angle check krne ke liye measure kese krenge site me
👍
Sir shuttering quantity nikalna btai sir
🙏
Happy concreting
Sir beam ka span Jo hum L/3 and 2l/3 Jo bhi le rahe hai ismai L clear span hai ya effective span ? Please replie
सर जी क्या छोटे से घर में भी इसी तरह का बिम लगाना पड़ेगा ?
Sir what is vertical shaft for plumbing??
Good Morning Sir
What will be column size for 1600 sq ft plot for three storey building
How we can analyse the angle of deformation of hokked or stirupps bars in site..??
thanks sir but loha nahi steel boliye thankyou
👌👍
सर जैसे कि बीम की रिंग इंटरनल डाली जाती है क्या कॉलम की रिंग भी इंटरनल दे सकते हैं
How do I make swimming pool on to my roof? What is its rod binding?& How do I seperate it's from roof. I want to need to learn heavy rod binding at different manner. Please help me.
Why we shouldn’t use laping in mid span of beam
Because bending moment is maximum at center there for we can't use lapping at bottom mid span
Column size reduce example 375 to 300.how to calculate columns vertical bar crank slop 1:6.
Sir 1200sq ft slab me Pura 10 mm sariya kitana lage ga or bhim he 9 inch ke
Folded slab means sunk slab ?
Yes
Explain with Structural drawing
Sir plz explain stair case at site
Sir I have one problem .plz upload video how to give BBS in auto cad file
eisa vido like
thanks sir
Sir iska pdf drawings chahiye kaise milega, aour ,shuttering and steel ka v drawings chahiye
Stair case shutteting
Hidden beam ka design kis book me milega ?
Sir slab m concrete nikalna batao
One more video sir
Especially beem ka lambai kya hai
sir i know stadpro software but not knowledge about its practical please give me suggestion and m try to many companies by mailing resume but no response
please help
Have Patience.
@@LearningCivilTechnology but sir koi solution
Sir, hum log column ke near me, beam ke bottom part me extra bar kyo nahi dalte?
Main ispe vdeo bana ke dal dunga
@@LearningCivilTechnology ok sir
Sir how to decide L length of beam??
Sir leg & Nos matlab
kenche ka length kase calculate karte hai
But kuch jaga extra bar bhi lgte hai us ko bhi smjo
Ap Jo slab pe khade hai vo itna down kyu hai compare to other portion
Your vedio recording is not good. The cameraman should zoom in the places where you are emphasizing. In nut shell recording part is to be improved
Aap ka number chahie ham log kuchh company mein kaam karna chahta hun ham log
Job milegi kya
Very super video for freshers✌️