Reinforcement lapping Zone as per IS Code 13920 in Column | Learning Civil Technology

Поділитися
Вставка
  • Опубліковано 29 січ 2025

КОМЕНТАРІ • 217

  • @LearningCivilTechnology
    @LearningCivilTechnology  5 років тому +16

    Video ko Daba ke Share karo bhailog aur apna pyar dikhau.. Taki hamare sabhi bhahiyo, hamare Juniors aur Engineers tak pahuch sake.

    • @manojsuthar5041
      @manojsuthar5041 5 років тому

      Sir plinth beam top se floor beam bottom hight hi length hoga kya

    • @mdshahanshahalam6262
      @mdshahanshahalam6262 4 роки тому

      I like ur videos more than other's videos.....

    • @Mahijavre
      @Mahijavre 3 роки тому

      Sir middle zone me to bending moment kam hota he na tabbi ties ki spacing ku kam rkhte he

  • @abubakarsiddik5033
    @abubakarsiddik5033 3 роки тому +1

    Sir I'm form Bangladesh,You are my very good teacher.Your explanation is very good sir.
    Thank you so much,keep your update your video.

  • @SurajKumar-oc3he
    @SurajKumar-oc3he 3 роки тому +1

    Sir aapka video dekhne ke bad pura tarah se satisfied ho jata hu bhagwan aap ko aise aur mind ko clear rakhe 👏

  • @VeerBuildhouseEngineering
    @VeerBuildhouseEngineering 5 років тому +2

    knowledgeable video sir 👌👍

  • @krazyharsh5040
    @krazyharsh5040 3 роки тому +1

    your explaination is very good

  • @mdshoaibhossain360
    @mdshoaibhossain360 3 роки тому +1

    u r so good person! ❣️
    Allah bls you

  • @raviyadav5
    @raviyadav5 2 роки тому

    I have downloaded your IS Code app.You have done a fab job brother.

  • @vinodjoshi1234
    @vinodjoshi1234 Рік тому +1

    Mukesh ji I like you for good teachings

  • @AKTV_786
    @AKTV_786 2 роки тому

    #Beam zone required. Beautifully explained.

  • @UttamSingh-ee5oj
    @UttamSingh-ee5oj Рік тому +2

    Sir I am Engineer but I can't explain as you explain. Thanks sir 🙏

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 5 років тому +1

    Superb video sir.
    #Beam and Slab lap zone

  • @anildas888
    @anildas888 2 роки тому +1

    Good and informative video. Thanks!

  • @arunkumarkarn1995
    @arunkumarkarn1995 4 роки тому +1

    NYC videos about lap zone

  • @gudiyaali1357
    @gudiyaali1357 2 роки тому +1

    Good job 👌

  • @mdahmed9336
    @mdahmed9336 4 роки тому +1

    Very nice👌👌👌

  • @shashikanth3648
    @shashikanth3648 2 роки тому +1

    Excellent sir

  • @phyohtetkoko929
    @phyohtetkoko929 2 роки тому +1

    Thanks For Teaching Sir

  • @ashwinanandh7590
    @ashwinanandh7590 5 років тому +1

    Excellent sir.. 👍👍👍🙏🙏🙏🙏

  • @shadabhussain3695
    @shadabhussain3695 3 роки тому +1

    Bro ur teaching is damn good
    👍🏻 Keep it up
    Tnx for clearing my concept

  • @shibnathbanerjee7821
    @shibnathbanerjee7821 3 роки тому +1

    Hats of to you sir...

  • @ziauddin7948
    @ziauddin7948 2 роки тому +1

    👍👍# good lap zone in column #

  • @devcpwd
    @devcpwd 2 роки тому +1

    Thank you for your support

  • @rahulsingha2227
    @rahulsingha2227 3 роки тому +1

    Bahat achhaa!

  • @mahadevchinchali2843
    @mahadevchinchali2843 3 роки тому +1

    Well explained

  • @ShahabUddin-fu5yq
    @ShahabUddin-fu5yq 5 років тому +4

    Also make video on beam and slab for overlapping

  • @RajeshKumar-my2ri
    @RajeshKumar-my2ri 7 місяців тому +1

    Very good video

  • @shivamitvlogsnz2416
    @shivamitvlogsnz2416 5 років тому +6

    Also make video on staircase. As most of the people get confused while calculating treads and risers on actual site. Most important is staircase which is starting from some random floor. Which is not in continuation.

  • @eguru786
    @eguru786 3 роки тому +1

    Beam lap also required .
    Thank you soo much.

  • @vinodkarle2630
    @vinodkarle2630 5 років тому +1

    अच्छा.व्हिडीओ.धन्यवाद.सर.

  • @ajaz545
    @ajaz545 4 роки тому +1

    Bhut gazab sir Plz Do some Thing for compitative exam

  • @b.m.sudhakar6595
    @b.m.sudhakar6595 2 роки тому +2

    Your my Guruji

  • @-adnanKhaja
    @-adnanKhaja 4 роки тому +1

    Thank a lot sir

  • @gkengr
    @gkengr 6 місяців тому +1

    Very well and technically explained

  • @MADHAVMULTYPRINTHasmukh
    @MADHAVMULTYPRINTHasmukh 4 роки тому +1

    Thank you sir

  • @prajayurkude9821
    @prajayurkude9821 4 роки тому

    Its very good vidio. Please make vidio on mivan Constructions steel.

  • @success555
    @success555 5 років тому +2

    Very Good Follower Base. Good Luck. #Success555

  • @engrkhalilnaz9019
    @engrkhalilnaz9019 5 років тому +1

    Very nice sir .make vedio also beam ,slab lapping

  • @YogeshLohar93
    @YogeshLohar93 Рік тому +2

    Auto level pe video banao sir....

  • @KamalSrivastava-k4h
    @KamalSrivastava-k4h 10 місяців тому +1

    Thank u sir

  • @arunkumarkarn1995
    @arunkumarkarn1995 4 роки тому +1

    Please make videos on RE wall highway

  • @haidaralikhorejia8984
    @haidaralikhorejia8984 4 роки тому +1

    Excellent sir. Please sir still ki quantity nikalna batao. Kaise still ki quantity ko nikale total slab, beam, coloum etc.

  • @dimpalrana7183
    @dimpalrana7183 4 роки тому +1

    Nice sir

  • @saileshsingh1
    @saileshsingh1 4 роки тому +1

    Thank you very much for the practical knowledge on Lapping Zone in column.
    It is increasing our knowledge and confident in real time environment in site.
    I have one question regarding column.
    What could be the solution if the length of the reinforcement from isolate foundation is not enough for Lapping which should be provided for second or next story of building ?
    Thank you and Regards!
    Shailesh Singh.
    Nepal

  • @tarunpigfarm1629
    @tarunpigfarm1629 3 роки тому

    Good sagsion

  • @amitjoshi1872
    @amitjoshi1872 8 місяців тому +1

    Absolutely sir

  • @MADHAVMULTYPRINTHasmukh
    @MADHAVMULTYPRINTHasmukh 4 роки тому +1

    Very nice app

  • @jackybosko1362
    @jackybosko1362 4 роки тому +3

    Thanks for Ur valuable information. I want to know one information, what is the joggle length and its ratio of the lapping bar as per the code reference.

  • @shankarsinghaniya617
    @shankarsinghaniya617 2 роки тому

    Hello sir..
    Yaha lap ham upar se jo joint karenge us steel me dena hai ya niche wala me.

  • @vivekborse2790
    @vivekborse2790 3 роки тому

    nice information , take a example of floor to floor ht 4 m , and give detail of lapping and lap length for footing to coloum , and above

  • @mohammadshoaib2073
    @mohammadshoaib2073 Рік тому

    Column ki laping beam wale porsen me kr sakte h

  • @kalindrasingh5459
    @kalindrasingh5459 4 роки тому

    Thank you sir.....ur valuable information.sir i want to know that about bbs.

  • @owaisulqamar1617
    @owaisulqamar1617 4 роки тому

    Sir plz bta dain stagger kB provide krte hai raft me

  • @gowrinaidu7656
    @gowrinaidu7656 4 роки тому

    waterpoofing mixing details at buildings prepare one video sir.....

  • @raviprakash8640
    @raviprakash8640 5 місяців тому +1

    Nice

  • @adityashekhar852
    @adityashekhar852 3 роки тому

    Sir splice mai jo ties provide krte hai uska spacing kitna hota hai ???

  • @ShahabUddin-fu5yq
    @ShahabUddin-fu5yq 5 років тому +1

    Plz make a video on importance of primavera p6

  • @MuktarMia-u1e
    @MuktarMia-u1e 13 годин тому

    Excelent...

  • @mamasconstructiongroup
    @mamasconstructiongroup 2 роки тому

    Slab beam ke Ander column r/f ka lap de sakte h kya

  • @CreativeCreative-sc8me
    @CreativeCreative-sc8me Рік тому

    Each floor lap divide karna kya sir

  • @SarukKhan-dc7xk
    @SarukKhan-dc7xk 12 днів тому +1

    Sir love u🎉

  • @jitulkalita6579
    @jitulkalita6579 3 роки тому

    Sir me assam se hu . mera building me column ka 6 sariya me 4 ko job join kiya tha usme laping kiya baki bij ka 2 me laping kiya nahi .kiya kharab hoga kiya .abhi me groun floor banaya he .

  • @sanjayswain9763
    @sanjayswain9763 2 роки тому

    Sir, I want to know that.... Ki sariya ka dia Or quantity saman hona chahiye ya nanhi..... 1000sq building ka sab Callum ka

  • @ravikirankadam3306
    @ravikirankadam3306 2 роки тому

    Sir while calculating L beam depth should minus or not

  • @shahabdulhaqim8900
    @shahabdulhaqim8900 4 роки тому +1

    PLEASE MAKE A VIDEO ON LEVEL OF. SLAB. ( SLAB ka level kaise check krte hai before casting)

  • @babusjohn
    @babusjohn 10 місяців тому

    Hi mukesh... i have a question. Between both the lapping zone how much should be the spacing? I mean 50% rebars to be lapped below centerline and 50%above centerline. Should there be any gap between these staggered bars?

  • @firdous529
    @firdous529 5 років тому

    Sir ; Bridge pier or abutment will be same Lapping zone

  • @sahiljharia8850
    @sahiljharia8850 Рік тому

    In addition to that minimum clear vertical distance between lapped bars shall be 0.25 times lap length. What is this?

  • @sunaramsingh6881
    @sunaramsingh6881 3 роки тому

    Kese Membership lena hai

  • @debasisghosh6697
    @debasisghosh6697 4 роки тому +2

    Jab column k vertical bar k dia change hota hai tab humko kakha lapping dalna hai?????
    Matlab 2nd floor k bad mera steel k dia change hone wala hai..tab konsi jaiga par lap dalna hai?????

    • @LearningCivilTechnology
      @LearningCivilTechnology  4 роки тому

      lap always zone B

    • @debasisghosh6697
      @debasisghosh6697 4 роки тому +1

      I know the lap provides always zone B...But
      How it's possible when my dia of bar change in 2nd floor...!!!so how can i extend the bar B zone in 3rd floor...!!!

    • @9549549543
      @9549549543 4 роки тому +1

      @@debasisghosh6697 please clear you Quotation I think for example 3rd floor par dia 20 hone wala hai aur 2nd par 25mm hai. To 25mm ka bar 3rd floor par zone B ke center tak jayega. Aap kehna chahte ho ki me steel 3rd floor par 25mm kyon du.

  • @sharadbarman6491
    @sharadbarman6491 3 роки тому

    Sir colomn ki clear length beam bottom se Lena hai ya slab bottom se ? Kyoki beam bottom , slab bottom se down hi hoga

  • @aibansharailyngdoh8608
    @aibansharailyngdoh8608 2 роки тому

    Bro,in lap zone do we used 45D

  • @lakhandas
    @lakhandas 3 роки тому

    Total station operation video banaye sir G

  • @shaikhssr7417
    @shaikhssr7417 4 роки тому

    16mm bar 45d kar k kat diya hun... isku over lapping dene se koi problem hoga????

  • @vykuvicky7573
    @vykuvicky7573 4 роки тому

    Sir I have one doubt about feture extension of building we leave 1 height of steel for feture extension but that is not a lap zone.then what we do for that for over come that problem

  • @shivamitvlogsnz2416
    @shivamitvlogsnz2416 5 років тому +1

    Also make a video on water proofing of terrace. What are the best materials present for it in the market.

    • @LearningCivilTechnology
      @LearningCivilTechnology  5 років тому +1

      already made a video on waterproofing of terrace..few days back... check my videos

    • @shivamitvlogsnz2416
      @shivamitvlogsnz2416 5 років тому

      @@LearningCivilTechnology yeah sure...Great 🙂

    • @javedkhan-eu2sx
      @javedkhan-eu2sx 5 років тому

      Thank you for this video.pls make a video on beam lap required.👍

  • @gayathrijayaraman9800
    @gayathrijayaraman9800 4 роки тому

    Pls explain abt shear wall bro

  • @AshokYadav-ov9uy
    @AshokYadav-ov9uy 4 роки тому

    Jab ham clear cover ki baat karte hain to beam ya column dono cases me yah clarify Karen ki langitudinal bar ke outer face se clear cover consider Karen ya stirrups/ ties ke outer face se.Thanks

  • @sapatesantosh0
    @sapatesantosh0 4 роки тому

    Lapping lower dia ya higher dia interview Questions?

  • @sgpfamilysgpfamily844
    @sgpfamilysgpfamily844 3 роки тому

    Sir , now column height is 2.5m and stirrups spacing is 150mm. This data’s are given as per drawing ..L/6 area it has less spacing .I what spacing should use here (L/6)

  • @rahulgarg4335
    @rahulgarg4335 5 років тому

    Mukesh ji only column beam junction mai actually minimum numbers of ring set kitne provide krne chahiye as per which is code

  • @govindsingh8168
    @govindsingh8168 5 років тому +1

    🙏 🇮🇳 👍 😍 #beamlap required

  • @adityatiwari-lv6yb
    @adityatiwari-lv6yb 4 роки тому +1

    Beam ke leye bhi video bana degeye

  • @ABHISHEKYADAV-oj6zt
    @ABHISHEKYADAV-oj6zt Рік тому

    # plz tell about cutting length of steel from foundation so that we can avoid zone A for floor height 3mtr..❤

  • @chetanrana6427
    @chetanrana6427 3 роки тому

    G+2 ke liye column, beam or plinth Ka kya size rkhe

  • @mukeshmani2003
    @mukeshmani2003 5 років тому

    from the edge of the bottom or the top of the slab into the column, what shall be the minimum distance to provide the ties.

  • @oldephart471
    @oldephart471 3 роки тому +1

    Any change in lapping zone if couplers are used?

    • @LearningCivilTechnology
      @LearningCivilTechnology  3 роки тому

      No

    • @oldephart471
      @oldephart471 3 роки тому

      @@LearningCivilTechnology I can't find Section 7.2.3 (in the copy of the IS code I have) to understand transverse reinforcement as mentioned in Fig 12. Please give me a link to the right version of the IS code.

  • @mkhurshid2961
    @mkhurshid2961 4 роки тому

    What happen if the lapping given by welded ? Kindly make a vedio about why engengeers do not let welding any rebar joint in the building design ? Please let me know ! ?

  • @pg-ce-007ankitaroykarmakar2
    @pg-ce-007ankitaroykarmakar2 4 роки тому +1

    Sir agar building ka height 12m se kam hua toh kya lap de sakte hai???

  • @rishavverma1611
    @rishavverma1611 4 роки тому

    Bar me Kita mm ka minimum rod use karte hai

  • @tsheringdorji2848
    @tsheringdorji2848 4 роки тому

    how can we get your apps on ios.?

  • @adityaghosalkar431
    @adityaghosalkar431 Рік тому +1

    Mukesh tum yaha ho..Mai Kabse dhund rha tha

  • @b.m.sudhakar6595
    @b.m.sudhakar6595 2 роки тому +1

    Beam lap required Sir ji

  • @sunilthakur4290
    @sunilthakur4290 5 місяців тому +1

    Sirmera columns plinth beam se11ft hai toh lapping Kiana ft par hoga

  • @vinodkumarsingh1146
    @vinodkumarsingh1146 3 роки тому

    Yadi lap plinth beam me hai to Sahi hai ya galat ,yadi galat hai tab kya kare

  • @jineshkumaarvklm
    @jineshkumaarvklm 4 роки тому

    Sir it’s not available in App Store .. I could not find .. pls help

  • @skjha1947
    @skjha1947 4 роки тому +1

    Sir Column ko jab overlapping krte hai tab L/4 rule ke liye column ka total height ground se count hoga ya floor to slab? Please

  • @9549549543
    @9549549543 4 роки тому

    Agar zone B me bars ko starting karni padi to kya karenge. How it possible with overlap?

  • @hassanhaider9651
    @hassanhaider9651 3 роки тому

    Sir please confirm thi, bar dia 25mm hai, uska lap zyada hai, ab lap ka kuch portion plinth beams me ja rha ha, tou kya ye possible hai ke hum uper jo columns uthayengy unko plinth se lap krkey utha len? Please confirm this sir thankyou so much

  • @amarkumar-hx8bk
    @amarkumar-hx8bk 5 років тому +2

    Lap joint in beam as per is13920 2016

  • @hariomkushwaha2537
    @hariomkushwaha2537 4 роки тому

    Sir jese her ek cheej ki ek limit h lekin by chance limit s gar 1 c.m. jyada ho Gaya to koi nuksaan to nai h