Practical Checklist Videos | Points need to Check for RCC Columns Reinforcement at Construction Site

Поділитися
Вставка
  • Опубліковано 3 січ 2025

КОМЕНТАРІ • 75

  • @LearningCivilTechnology
    @LearningCivilTechnology  5 років тому +4

    To Connect with me Personally Subscribe - Hindi Talk with Mukesh
    ua-cam.com/channels/Z9Jn9AW3zc1ekOuCqLlAOw.html
    On this channel I am going to teach you Everything related to UA-cam, Blogging, Adsense Approval Tips, Money making Tips and many More

  • @NomanAhmadBarvii
    @NomanAhmadBarvii 7 місяців тому +2

    Very informative Sir

  • @archnapatel7325
    @archnapatel7325 4 роки тому +1

    Sir apko pata hi hota hai ki kaise samjana hai bcz pahele theory after then at side video to dimaag me samj AA jata hai so very helpful video. Thank you:-)

    • @LearningCivilTechnology
      @LearningCivilTechnology  4 роки тому +1

      U WELCOME

    • @archnapatel7325
      @archnapatel7325 4 роки тому

      @@LearningCivilTechnology concrete admixture k type explain kijiye na usake pr video banaye kis time konasa use hota hai

  • @kshitijsingh4653
    @kshitijsingh4653 5 років тому +2

    Thank you sir. Keep making helpful videos for us. God bless you

  • @jaysingh3230
    @jaysingh3230 3 роки тому +2

    Helpful vedio sir

  • @Ankit-oy7is
    @Ankit-oy7is 2 роки тому +1

    Thank you so much for making this usefull video. 👍👍

  • @izzatshahi8760
    @izzatshahi8760 6 місяців тому +1

    Excellent vedio ❤

  • @salimjave1834
    @salimjave1834 4 роки тому +1

    Best practical video

  • @swamiggamingyt957
    @swamiggamingyt957 6 місяців тому +1

    Super G good work 👏

  • @er.mohammadalikhan882
    @er.mohammadalikhan882 4 роки тому +1

    Thanks sir bahut help mili

  • @ManojKumar-gt4ct
    @ManojKumar-gt4ct 3 роки тому +1

    Nice information
    Thank you so much

  • @Raj-cw9ln
    @Raj-cw9ln 3 роки тому

    Excellent video

  • @wesupportbjp9319
    @wesupportbjp9319 3 роки тому +2

    good knowledge....

  • @medhasingh7295
    @medhasingh7295 5 років тому +1

    Very knowledgeable. Keep it up

  • @abhishekabi9613
    @abhishekabi9613 3 роки тому +1

    Thank you brother

  • @success555
    @success555 5 років тому +4

    Practically think all things are fair.

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 5 років тому +1

    Excellent video sir. Thnx a lot

  • @CivilanishRaj
    @CivilanishRaj 5 років тому +1

    Thanks sir , or bhi vidios banaiye building construction se related taki hamlog sikh payenge

  • @ziauddin7948
    @ziauddin7948 4 роки тому

    good reinforcement column bars checking

  • @pradeepbharti6643
    @pradeepbharti6643 5 років тому +3

    Nice video sir

  • @prashantkothekar8104
    @prashantkothekar8104 5 років тому +2

    Sir plz slab aur staire case, chajja ka reinforcement aur shuttering ka checklist dalo practical video sir plz

  • @anuragpandey5333
    @anuragpandey5333 3 роки тому +1

    Thanks you sir

  • @khanfahad93
    @khanfahad93 4 роки тому +1

    thank you

  • @shaktisehgal9777
    @shaktisehgal9777 2 роки тому

    Sir, it is really a helpful video. Pls tell how many days curing is to be done after we have prepared the PCC and how many days of curing is needed for column footing and after the column is casted, do we have to fill the hole with big stones & sand or anything else ? Regards,

  • @pradeepbharti6643
    @pradeepbharti6643 5 років тому +4

    Two way slab ka Charo corner hame dikhaiye in field

  • @mahighuman5536
    @mahighuman5536 5 років тому +3

    Sir, can you explain how to provide any type of cut out in column or beam

  • @shashikantarath2567
    @shashikantarath2567 Рік тому

    Is there any provison to maintain gap between two bar for concrete?

  • @md.tausifalam212
    @md.tausifalam212 5 років тому +1

    Firstly thnks fr ur all videos sir. U r doing really sch a gr8 job fr us.
    Sir, I wanna ask dat...if the dia of bar is above 36 dia and we hv to weld the bars, then what will be the lap lenth for that..?
    Plz reply

    • @LearningCivilTechnology
      @LearningCivilTechnology  5 років тому +1

      Lap length should be given by Structural consultants on the basis of design.

  • @hasnatfarooqui799
    @hasnatfarooqui799 5 років тому +1

    I would like to request to u please make video abt terrace flooring....
    And it's completely guide please

  • @sudeep2580
    @sudeep2580 5 років тому +1

    How to check the plumb ? Please make a video on it .

  • @margubalammohammad1719
    @margubalammohammad1719 10 місяців тому

    Sir jaise ki alivason mein slab ki hite 4metter hai beam depth ko ghata L bye four karna hai ki beam pakar ke batana sir please

  • @Engrwaleed555
    @Engrwaleed555 4 роки тому

    You should have compare it with working drawing. That would have helped us.

    • @Engrwaleed555
      @Engrwaleed555 4 роки тому

      But thank you for sharing, some tips were very useful.

  • @bhaveshdeore3598
    @bhaveshdeore3598 5 років тому

    Excellent video sir 👍Sir can you make a video on practical checklist of Reinforcement for Retaining wall on site???

  • @ravikirankadam3306
    @ravikirankadam3306 3 роки тому

    Sir ji shuttering and centering ko min kitte thk of ply use karna konsa Grde MR, MWR, MWP

  • @prabhupadasahoo7483
    @prabhupadasahoo7483 4 роки тому

    What is the ratio of starter concrete and what is the height of starter as per the IS code.

  • @mohdmubeen5878
    @mohdmubeen5878 4 роки тому

    What is the coupling method of lapping in column ?

  • @nishantshinde3312
    @nishantshinde3312 4 роки тому

    Can you please do the video for placing steel in beams and columns??

  • @ranjansahoo8904
    @ranjansahoo8904 2 роки тому

    Can you give IS code reference for lapping position of bars in column?

  • @erprahlad4269
    @erprahlad4269 5 років тому +1

    Welding length in column

  • @civilexplorer7038
    @civilexplorer7038 4 роки тому

    Sir, Grade of Steel not more than Fe415 shall be used for Ties/Shear Stirrups.

  • @jigarpatel1727
    @jigarpatel1727 5 років тому +2

    👍👍

  • @Rosemary-xd3mi
    @Rosemary-xd3mi 4 роки тому

    Sir
    Why we apply zig Zag and alternative hooks in column

  • @Standwiththehindus
    @Standwiththehindus 4 роки тому

    What is the method to tie the reinforcement if the column has a dimension at bottom tapered at the top. I mean if the dimension is 900x900 at bottom and 700x700 at top. Dimensions are in mm.

  • @mohammedmoinuddin8359
    @mohammedmoinuddin8359 4 роки тому

    What to do in this case. Ground, first floor column have 16mm rebar. But on second floor the contractor placed 20mm rebar on top of 16mm rebar. Will this cause load transfer problem for example if there this is a 5 storey residential building.

  • @sunilchauhan6067
    @sunilchauhan6067 4 роки тому

    But not running any electrical material inner of column because effect strenght of column .....so I am confused plz reply sir.....

  • @kanchannarwade9575
    @kanchannarwade9575 5 років тому

    Sir reinforce Span 50ft video marking please

  • @sandeepkumarsingh5215
    @sandeepkumarsingh5215 4 роки тому

    Sir isme jo cover block provide kiya hai extra bar ke sath aisa q lagaya hai or kb lagate hai

  • @sugreevkumarprajapati915
    @sugreevkumarprajapati915 4 роки тому +1

    Sir Mai ek building g+5 tak ki ek apartment bana raha hu sir mujhe ye bataiye ki over laping mistri nahi de rahe hai sab batarahe hai ki kuchh nahi hoga sir lekin sir Mai aapka vidio dekha to mujhe laga ki over laping Dena jaruri hai please Sir bataiye sir Kya ham karawaye please Sir muje jawab chahiye sir please

  • @guhanathana5308
    @guhanathana5308 5 років тому

    Hello sir good morning I like to know how much should we calculate cutting length of 90 degrees bend steel

    • @NITAIKARMAKAR
      @NITAIKARMAKAR 3 роки тому

      90° bend length is 2d
      135° bend length is 3d
      Hook length 10d
      Column cover block 40mm
      Beam cover block 30mm
      Now calculate yourself. You can do it.

  • @shashankmaheshwari7970
    @shashankmaheshwari7970 5 років тому

    full length column ki height kitni rahti hai 18 feet

  • @greencastle3412
    @greencastle3412 4 роки тому

    Lap=joint

  • @SM-hv2mq
    @SM-hv2mq 3 роки тому +2

    Please give me your telegram link

  • @HOUSEDESIGNBYENGG
    @HOUSEDESIGNBYENGG 5 років тому +1

    Sir koi job hai aapke pass diploma ke liye