ANALYSING GAS APPLIANCES, how to flue gas analyse all gas appliances and understand your results.

Поділитися
Вставка
  • Опубліковано 24 лис 2024

КОМЕНТАРІ • 78

  • @jamesbraithwaite708
    @jamesbraithwaite708 3 роки тому +2

    Love these great for brushing up and refreshing the old memory at 30 🤣

  • @frankdunham6051
    @frankdunham6051 3 роки тому +2

    Hi Derek, I started doing my domestic gas at the start of this month and your videos are really helping me consolidate what I'm learning. Really good explanations and detail, keep up the good work, you're helping lots of people out there.

  • @louisdisbury9759
    @louisdisbury9759 Місяць тому

    I notice you analysed the boiler with the boiler cover on which on final commissioning is correct, Many Engineers analyse with the cover off forgetting that the boiler is drawing in air from the room and not through the flue which is crucial to safe operation of the boiler back in the day as you know ff boilers rarely operated with the cover off so by alll means carry our analysing the boiler with the cover off while commissioning and making adjustments but all ways carry out final analysing with the boiler cover correctly fitted to ensure correct operation of the flue.

  • @darrenfrancis9172
    @darrenfrancis9172 Місяць тому

    Hi chap, love the videos, really really helpful, keep them coming 👍👍👍 and thankyou for uploading them👍

  • @mj0n4id36
    @mj0n4id36 3 роки тому

    Nice explanations! First time I’ve seen someone actually flue gas analyse and explain the importance of doing so for other appliances too. Not just for combi boilers. Sweep test always seemed awkward for me but now having watching this video it has really helped. Thanks Derek 👍🏻.
    Asian Jon. Training.

  • @helendavies923
    @helendavies923 4 роки тому +1

    Really thorough and informative. Thanks, Derek!

  • @brenndonherbert4583
    @brenndonherbert4583 3 роки тому

    Brilliant video as always. Thanks for the amount of depth that you went into, gained a great amount of knowledge from that.

  • @michaelrose5040
    @michaelrose5040 4 роки тому +1

    Great video really helpful for my ACS
    Thanks Derek

  • @dagnallcadarngaming7413
    @dagnallcadarngaming7413 2 роки тому

    Great video. Can I ask where the flue integrity readings you quoted are found as in what documents please as I’m struggling. Thanks in advance.

  • @monikanader9454
    @monikanader9454 3 роки тому

    Great video, very informative. Thanks Derek 👍👍👍

  • @qmob0121
    @qmob0121 Рік тому

    Hotly would you test a top oven/ grill combi grill side ? In the same way you do the ovens or is there a another way to use the 7 hole probe to do it ?

  • @jockster5525
    @jockster5525 2 роки тому

    Quality mate really useful video as are all your videos .. absolute star 🌟

  • @dimitardimitrov3300
    @dimitardimitrov3300 3 роки тому

    Hi Derek. You are high level teacher and your way to teach is great. You speak so calm and friendly. We all appreciate this. Your videos helped me to improve my knowledge and understanding for my initial ACS. But on my ACS(which I still need to complete) they asked me to gas analyze the cooker hobs and they insist to go and do it. I needed to fill in the readings in the paper too. What will you advice me in this case. I light up the four hobs and hold the analyzer about 30 cm over but I wasn't sure if I do the things correct. Thank you so much! Appreciate all your hard work to teach us!!!

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому +1

      You don’t analyser the hobs on a cooker just the oven and grill separately. Not sure why they have asked you to do this as it’s not required unless you are carrying out a room test.

    • @dimitardimitrov3300
      @dimitardimitrov3300 3 роки тому +1

      @@tomkatgastraining You are such a good man. Thanks for your help 🙏❤️

  • @whome5810
    @whome5810 2 роки тому

    How long would the exhaust sample point have to be open to give higher CO readings in the room. Ie 50pp? Does how long this can be left open vary from boiler to boiler? It appeared that you left the exhaust sample point open while you were testing the air intake side, would this not raise levels of CO in the room? Anyway, great video!

  • @naturelover_9211
    @naturelover_9211 4 роки тому

    One more great video thank you Derek.

  • @raisapotoroaca4016
    @raisapotoroaca4016 4 роки тому

    Morning Derek following your pipe bending tutorials do you think you can do some videos about pipe sizing as well
    It will be lovely to see how to measure correctly if it’s possible.
    Thank you very much and please stay safe!!!

  • @rivkiroyde4362
    @rivkiroyde4362 4 роки тому

    Thanks Derek great video👍👍👍👍. Benny

  • @vladimirstafasani4630
    @vladimirstafasani4630 3 роки тому

    Excellent video love it.
    Is dynamic pressure same as inlet pressure or working pressure in the boiler?
    Thank you Derek

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому +1

      Benchmark seams to have changed max pressure to dynamic pressure so I guess so 👍🏻

    • @vladimirstafasani4630
      @vladimirstafasani4630 3 роки тому +1

      @@tomkatgastraining many thanks 👍

  • @Zinadene69
    @Zinadene69 3 роки тому

    Hi Derek,
    I see you have shown how to test an inset gas fire, where you need the extension on the probe.
    What I would like to know is, are you able to demonstrate how to analyse a High Efficiency (HE) Inset Gas Fire, which come with a sealed glass front?
    (PS Great videos. Very helpful and informative)
    Stay safe

  • @bernardgatdula9094
    @bernardgatdula9094 3 роки тому

    One day please discuss about the electrical system of Bosch Gas Range Thank you.

  • @oneloveonelifeman
    @oneloveonelifeman 4 роки тому

    Missing been down the center. Hopefully there soon!

  • @sanjit41
    @sanjit41 4 роки тому

    Great one again,are you going to make video about flue/chimney?

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому +1

      Sanjit grg in the to do box mate 👍🏻

    • @lissa020609
      @lissa020609 4 місяці тому

      ​@tomkatgastraining so if someone had drilled a hole in the flue and it was only AR would it still be riddor because it had been done by a engineer that should know better 🤔 sorry not long started learning

  • @dkaloupis75
    @dkaloupis75 2 роки тому

    Procombi Exclusive 24 there is no chance to adjust the minimum or high settings. Any advice on that?

  • @ryandow3954
    @ryandow3954 4 роки тому

    Brilliant video!

  • @ChelseaFC190512
    @ChelseaFC190512 Рік тому

    If there's no MIs like the older boilers then what do you refer too

  • @lostinthoughtscalminsilenc8167
    @lostinthoughtscalminsilenc8167 2 місяці тому

    Please do more back boiler videos

  • @darrensworkshop6783
    @darrensworkshop6783 8 місяців тому

    Hi Derek Do you have the facility to demo commercial kitchen appliances eg COMCAT1,3 and 5 and carry out a proper CP42 test? I teach this within my company but each engineer has their own way ....I teach using DW172 and IGEM/UP/19 standards.

    • @tomkatgastraining
      @tomkatgastraining  8 місяців тому +1

      Sorry mate we don’t have commercial kitchen at tomkat 😢

  • @zaygoodfellowofficial
    @zaygoodfellowofficial 4 роки тому +1

    Informative
    Muhammad Faisal Abbasi

  • @samchappell233
    @samchappell233 3 роки тому

    👍👍👍 great video!

  • @albyhendriks4024
    @albyhendriks4024 2 роки тому

    Great information

  • @lostinthoughtscalminsilenc8167
    @lostinthoughtscalminsilenc8167 3 роки тому

    Great video

  • @farobenz6144
    @farobenz6144 4 роки тому

    Hi
    What do they mean by initial and final combustion?
    Thanks

  • @paulrossiter9567
    @paulrossiter9567 4 роки тому

    Brilliant video , thanks very much for the in depth recap.
    I don’t like my Kane anymore after seeing yours 😂

  • @darrenclarke161
    @darrenclarke161 4 роки тому

    Great info 👏👏👍

  • @suheilhanna873
    @suheilhanna873 3 роки тому

    Such an educational, 53CO 0.0006 ratio.
    is that normal on high setting, I thought CO should be below 30ppm . ratio 0.0004 or under?? .. Still training ...😊... you are a 5 💫💫💫💫💫

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому

      For boilers your co could be up to 350 ppm and co2 of up to 10 .2 and a ratio of less than 0.004 depending on the boiler.

  • @paulmilton6123
    @paulmilton6123 4 роки тому

    Thanks great video's 👍👍

  • @RahulSingh-jn7py
    @RahulSingh-jn7py 2 роки тому

    Does any one know the ratio of the open flued back boiler as in what it is and where i can find it?

  • @abchannel3737
    @abchannel3737 4 роки тому

    You are the best

  • @aaronjoyce1980
    @aaronjoyce1980 3 роки тому

    Watched Aaron trainee 😁👍👍

  • @asbestosflake5749
    @asbestosflake5749 3 роки тому

    Do same video but on a Worcester green star please.

  • @garlic1558
    @garlic1558 4 роки тому

    Very good 👍

  • @andrewturpin1994
    @andrewturpin1994 3 роки тому

    You mentioned caravans several times in the video which spiked my interest as this is my trade, would be very interested in seeing these tests done on an a modern oven in a touring caravan or motorhome 🚐

  • @faroyoussef1757
    @faroyoussef1757 Рік тому

    Sweep test with cover on ? Or cover off?

    • @tomkatgastraining
      @tomkatgastraining  Рік тому +1

      Sweep test is testing the covers seals so the cover has to be on

  • @l3thal356
    @l3thal356 3 роки тому

    Anyone know the best place to put a flue gas analyser probe on an openflue boiler?

    • @tomkatgastraining
      @tomkatgastraining  3 роки тому

      Watch my other videos on analysing and you will find out 😜

  • @matttate9155
    @matttate9155 2 роки тому

    Can you please change the background music in your videos, or better still, just have none.
    It’s pretty much the one and only thing that drives me demented with your videos.
    Other than that, keep them coming!

    • @tomkatgastraining
      @tomkatgastraining  2 роки тому

      Not had music in my videos now for over a year 👍🏻

    • @matttate9155
      @matttate9155 2 роки тому

      @@tomkatgastraining
      Yeh ok cool. The video I commented on was a year old now I look back though. The xylophone music was pretty awful though! Lol

  • @ianferguson8367
    @ianferguson8367 4 роки тому

    brillant

  • @saheedk1
    @saheedk1 2 роки тому

    I love u so much

  • @joaovittoria2533
    @joaovittoria2533 3 роки тому

    👍👍

  • @marvindallen8916
    @marvindallen8916 2 роки тому

    👍🏾

  • @gtroadster8035
    @gtroadster8035 4 роки тому +1

    Isn’t oxygen 20.9?

    • @tomkatgastraining
      @tomkatgastraining  4 роки тому +1

      In the atmosphere yes but on flue integrity we are looking for readings higher than 20.6 o2 and less than 0.2 co2 to prove the flue is ok

    • @gtroadster8035
      @gtroadster8035 4 роки тому

      Okay , I’m regards to the flueless fire. I came across a flueless fire with 2 catalytic converters. 1 on each side. How would I test when there is one on each side?

  • @natugrmaxion8337
    @natugrmaxion8337 4 роки тому

    👍

  • @mervinpermalloo8589
    @mervinpermalloo8589 Рік тому

    🙏👍

  • @craighurst3599
    @craighurst3599 4 роки тому

    CH 👍

  • @jon-paulward4580
    @jon-paulward4580 2 роки тому

    Jon-Paul Ward

  • @secondchance4498
    @secondchance4498 3 роки тому

    chris Taylor

  • @mgbroadsterJ
    @mgbroadsterJ Рік тому

    death trap .

  • @Mrcatcherye
    @Mrcatcherye 2 роки тому

    no-one in their right mind would bother analyse a LFE fire. Pointless.

  • @chrisjones4500
    @chrisjones4500 2 роки тому

    👍👍