👍Thermostat Wiring for BEGINNERS !!!

Поділитися
Вставка
  • Опубліковано 30 січ 2023
  • All you need to know about thermostat wiring #shorts #diy #homerepair #tools
    ********CLICK TO SUBSCRIBE****** ua-cam.com/users/deaninityours...
    -------- Tools and Parts Used In This Video -------
    Ecobee thermostat: amzn.to/3Y5yzpS
    Nest Thermostat: amzn.to/3HhtnZe
    -------FOLLOW MY CHANNEL------
    Facebook: deaninityourself
    Instagram: deanin_it_yourself
    Tik Tok: deaninityourself
    #diy #diyhacks
    DISCLAIMER: This video and description contain affiliate links, which means that if you click on one of the product links, I’ll receive a small commission. This helps support the channel and allows me to continue to make videos like this. Thank you for the support!
  • Навчання та стиль

КОМЕНТАРІ • 57

  • @stefanroemer4489
    @stefanroemer4489 2 місяці тому +7

    Don't trust the color. It depends on your installer

    • @killer2600
      @killer2600 2 місяці тому +1

      This...when installing a replacement thermostat all that matters is where on the old thermostat the wire was connected. Thermostat terminals are more standardized than the wire colors.

    • @DJV94022
      @DJV94022 17 днів тому

      True,copper is copper the color coating just helps to get from point A to B .
      When you see a black or brown being used and a color not being used or cut short then that explains it
      Unless you wanna be a evil person and change all the colors and make it hell for a new tech or a senior tech get an heart attack

    • @qaswed854
      @qaswed854 4 дні тому

      @@killer2600what if the old thermostat is wired wrong

  • @NDC1115
    @NDC1115 Рік тому +61

    So much wrong here.
    W is call for heat. Does not matter if it's electric or gas.
    G is fan on/off, it dose not change speed, that's done on the control board in the unit.
    Y is not for the "compressor", it's call for cooling, a separate wire goes from the indoor unit to the outdoor unit.
    C is common, but not all thermostats require it, most run on alkaline batteries.

    • @huntermuir833
      @huntermuir833 Рік тому +5

      where does my black wire go ?

    • @nonfiction_4life156
      @nonfiction_4life156 11 місяців тому +2

      Don't even tell him

    • @CardHunters709
      @CardHunters709 11 місяців тому +1

      ​@@huntermuir833Most time it's either not used/spare wire. It's usually used for stage 2.

    • @chert023
      @chert023 11 місяців тому

      I had a problem I have an electric heater but I couldn’t plug it in my W wire because when I did and turned the cool on it blew out hot air only so I read up and it said to plug it into the O/B wire and it started blowing cool is this normal.

    • @threestans9096
      @threestans9096 10 місяців тому +5

      y is technically compressor contactor for cooling.
      c is common and many res does need it when code calls for it to be hardwired as well as battery.
      g is blower fan relay.
      w is heat valve or relay for heating.
      o is heat pump energized in cooling
      b is heat pump energized in heating..

  • @DJV94022
    @DJV94022 17 днів тому +1

    Florida people:
    The units are called heat pumps
    R-24volts
    C- negative (-)blue wire
    Y-to kick on your compressor/heatpump outside unit
    W-heat strips (winter time)
    O- when it gets 24v from the thermostat it goes into cooling mode (if you own a rheem or rude ignore this)
    G- is to turn on your indoor unit (blower)
    Black and brown are extra wires
    If you have different colors being used on a good running unit dont question it.. if its different its for a reason sometimes in the 500feet roll of thermostat wire factorys sell the roll with broken wires or in new construction the wires get caught with a nail or drywall people destroy the wires somewhere
    So mostly it takes 6 wires to run the air conditioner 2 extra wires for additional equipment or broken or damaged wires

  • @laurazickefoose1037
    @laurazickefoose1037 3 місяці тому +1

    What if you have a black wire and no brown wire?

  • @user-vv8os9hb3v
    @user-vv8os9hb3v 5 місяців тому +3

    down here in south carolina they dont give a shit what wire goes where

  • @jonathansanchez10
    @jonathansanchez10 6 місяців тому +1

    What if I have E the black one?

  • @stevenaugust8819
    @stevenaugust8819 Рік тому +2

    Made it easy thx😊🌍🤔

  • @saltystone103
    @saltystone103 3 місяці тому

    This was wonderful, thank you.

  • @Championwarlord
    @Championwarlord Рік тому +1

    Great video

  • @TARANS012
    @TARANS012 4 місяці тому

    Mine has 12v Red , GND Blue, C Yellow, D white . Now how to I link these to Smart thermostat that have no Ground or 12v label ?

  • @kaplertv936
    @kaplertv936 11 місяців тому +1

    Thanks 🙏🏾

  • @joeyhenry9585
    @joeyhenry9585 Рік тому

    What is y1 y2 w2 color

  • @joseferreira9944
    @joseferreira9944 27 днів тому

    Estas cores estão ligadas assim correspondente as letras no meu antigo thermostat, vou ligar igual, só espero que não pegue fogo 🔥 kkkk… valeu 😅obrigado pelo vídeo.

  • @MidwestHome_Hens
    @MidwestHome_Hens Рік тому +1

    BUT what is that second white wire that is going from RH to RC?? I have a 2nd red wire doing the same thing????

    • @DeaninItYourself
      @DeaninItYourself  Рік тому +6

      its just a jumper cable that connect the Heating and the cooling circuit, this is used so that the thermostat can switch between heat and cool and you dont need to run a separate wire back to your air handler.

  • @krissy_c
    @krissy_c 5 днів тому

    My brother tried to change thermostat to eco bee but said he couldn't install due to c wire missing .. any advice 😢

    • @DeaninItYourself
      @DeaninItYourself  3 дні тому +1

      Sometimes the c wire is cut off. Peel back the insulation and check if the blue wire is there. I have another video explaining this.

  • @julianperez-robles6921
    @julianperez-robles6921 11 місяців тому +1

    I have one red wire from the wall but on my thermostat there a red small wire running from R to Rc and idk why?

    • @DeaninItYourself
      @DeaninItYourself  11 місяців тому +1

      It is a jumper cable so that heating and cooling have power. That is normal.

  • @LarryRichelli
    @LarryRichelli 5 місяців тому

    I just bought a new home and the thermostat drives me crazy because when I try to turn it off the the only two fan settings are off or automatic so the fan is always one. If anyone can help me with this I would appreciate it

  • @UnorthodoxTHC
    @UnorthodoxTHC 8 місяців тому

    thanks bro

  • @NewHvac
    @NewHvac 7 місяців тому +3

    Don’t do this at home😂 you might have no ac or heat when needed.

  • @SoGQue
    @SoGQue 5 місяців тому

    What about if the unit is wired to a smoke detector?

  • @chrismittendorf7337
    @chrismittendorf7337 Місяць тому

    That doesn't tell me how it works

  • @Jackred94
    @Jackred94 Рік тому +2

    Thank you, this is a very useful video.

  • @qaswed854
    @qaswed854 4 дні тому

    does the red wire go to RH or RC

    • @DeaninItYourself
      @DeaninItYourself  3 дні тому

      Rc

    • @qaswed854
      @qaswed854 3 дні тому

      @@DeaninItYourself got a heat pump and the white wire is connected to W2 and the black wire is connected to W/E

    • @qaswed854
      @qaswed854 3 дні тому

      @@DeaninItYourself something is causing cold air to come from the vents during defrost mode

  • @gazadan6623
    @gazadan6623 10 місяців тому +2

    There is no specific wire color

    • @Duck1cVE
      @Duck1cVE 8 місяців тому

      Yes if ur an asshole you can use white as a 120v hot leg as well

  • @user-tq9zn3bn2o
    @user-tq9zn3bn2o Місяць тому +1

    We all know colors smh

  • @NerdBryant64
    @NerdBryant64 11 місяців тому

    What about S1 and S2

  • @nonfiction_4life156
    @nonfiction_4life156 11 місяців тому

    Fan speed 😂😂😂😂

  • @mazheruddin8846
    @mazheruddin8846 7 місяців тому

    wow

  • @taylorjones3390
    @taylorjones3390 10 місяців тому +1

    Yikes hes right on where to put ‘em if they’re labeled right, sometimes you can have 2 red and white wires and ppl wouldn’t know. He’s describing this all wrong. Unless you have an ecobee thermostat (only ones I’ve seen so far) where you need to actually go inside the furnace and put your thermostat into their wires and then plug that into your thermostat terminals on your furnace. Your best bet is just buy one that’s simple and take a picture and do one wire at a time

  • @PlasmaBurns
    @PlasmaBurns Рік тому +2

    Instructions unclear. managed to stop the bleeding, waiting for new instructions.

  • @J.James999
    @J.James999 7 місяців тому

    how the compressor blow up.