ATORCH DL24 Configuration and Calibration

Поділитися
Вставка
  • Опубліковано 1 січ 2025

КОМЕНТАРІ • 28

  • @hikerJohn
    @hikerJohn 5 місяців тому

    I have that one on the right @ 16:48. Do you have a video on that one? I bought it to test a 100 amp battery but it just came today so have not used it yet. The one I got from Amazon is identical but with the brand name of "MakerHawk"

    • @jtechlabs1
      @jtechlabs1  5 місяців тому

      I haven't done a vid for it yet, but I will prioritize it I first saw it on ProjectFarm. One of the key differences is that it allows for very fine control over the load with a simpler control structure of the knobs.

  • @TheLittleBikeShop143
    @TheLittleBikeShop143 Місяць тому

    What is the app this works with? I cant find one anywhere

    • @jtechlabs1
      @jtechlabs1  Місяць тому

      Have you tried the pointers on the atorch website? There are instructions for both iOS and android. en.atorch.cn/Download.aspx?ClassID=11

    • @jtechlabs1
      @jtechlabs1  Місяць тому

      I did a little more digging and I found this link that appears to lead to some PC software.
      www.mediafire.com/folder/1c04afq923397/A3

  • @tf1389
    @tf1389 5 місяців тому

    Thanks i get the point but for dl24ew there is no dedicated port to plug the load. There is d, s etc. What are we gonna do?

    • @jtechlabs1
      @jtechlabs1  5 місяців тому +1

      Unfortunately, I don't have a DL24EW. I had a look at some product listings and they did not seem to have the same calibration option.

    • @tf1389
      @tf1389 5 місяців тому

      @@jtechlabs1 it is d for + and s for -

  • @F16_viper_pilot
    @F16_viper_pilot Місяць тому

    So, what’s the calibration standard used to ensure the power supply is putting out exactly 30 volts? Just because the power supply says 30.000 volts does not mean it’s correct, especially since the supply is set to its maximum limit.
    I would say the same thing for your 3 amp load. How do you know it’s 3 amps? What’s the reference?

    • @jtechlabs1
      @jtechlabs1  Місяць тому

      Yes, it is important to make sure that the references you use for calibration are accurate.

    • @F16_viper_pilot
      @F16_viper_pilot Місяць тому

      @@jtechlabs1 Okay, so in your video you didn’t make mention of how you ensured your power supply and the other load were calibrated. This is really important for people to know before they start mucking with the calibration of the load they receive, as they may end up making the device less calibrated than the out-of-box calibration.

    • @jtechlabs1
      @jtechlabs1  Місяць тому

      I appreciate you pointing out the importance of good calibration. I will keep that in mind for future videos.

  • @RingZero
    @RingZero 3 місяці тому +1

    Voltage reference: Would it not make sense to first check the accurate 30V input at the terminals using a fairly accurate multimeter?
    Amp reference: How about using a precise resistor at the terminals to provide that 3Amp load ?
    The wires carrying the volts and the load to the terminals always has resistance and skew the values.

    • @jtechlabs1
      @jtechlabs1  3 місяці тому +1

      It's an interesting question. I measured the resistance of the leads from the power supply at 0.1 ohm. The load in that "circuit" is at best 1mA. So the voltage drop from the leads would be 0.1 mV (.0001V). For the purposes of this device that level of accuracy is likely fine.
      For the amp reference, you can use anything you want that will cause a 3A load, you don't need to use an electronic load like I did. You need to keep in mind that a 3 A load at 12V is going to generate a pretty good amount of heat (36W). Even at 5V a 3A load will generate a decent amount of heat (15W). You would need a higher power resistor to prevent the resistor from melting down. I have seen some people use a circuit with a light bulb and an ammeter in series and adjust the voltage until the meter reads 3A. A typical light bulb can handle that level of heat.

  • @Rydal1
    @Rydal1 4 місяці тому

    how do i get it to work with a powerbannk

    • @jtechlabs1
      @jtechlabs1  4 місяці тому

      Have a look at this video ua-cam.com/video/HjY95-U7_4U/v-deo.html
      It shows a 12V battery. For a power bank you will likely have 5V and set the current to a typical load like 3A or 3.5A. I would suggest setting the cutoff voltage to 3V.

  • @drumetu71
    @drumetu71 3 місяці тому

    Is that calibration absolutely necessary? To know if I cancel the order for DL24 or not, because I don't have the possibility to do those calibrations

    • @jtechlabs1
      @jtechlabs1  3 місяці тому +1

      The unit comes calibrated from the factory. Calibration doesn't impact function, it impacts accuracy. For example suppose the voltage is off by 0.1V in a 5V test setup. That's 2% error. If you were calibrated the error would likely be closer to 0.02%

    • @drumetu71
      @drumetu71 3 місяці тому

      @@jtechlabs1 THANKS!

  • @koarkung
    @koarkung 2 місяці тому +1

    ❤❤❤

  • @alexandergreenfield91
    @alexandergreenfield91 2 місяці тому

    Hi Jim love the video. Not sure if anyone's ever mentioned it but you sound quite a lot like kermit the frog. If on your next video you could make a reference to miss piggy it'd make my day. 😂

  • @lezbriddon
    @lezbriddon 5 місяців тому +1

    so when you have bought one, you need to buy a 2nd to calibrate the first, but the 2nd one wont be calibrated so you need to buy a third, but the third wont be calibrated....
    Maybe we just need to use the calibrate out socket to a 12v 55w car headlight bulb in series with a multimeter set to amps, then adjust input voltage to change brightness of bulb/meter reading for 3amps and press the set button..

    • @jtechlabs1
      @jtechlabs1  5 місяців тому

      You can absolutely use any known 3A load

    • @dv5809
      @dv5809 4 місяці тому +1

      You can simply short-circuit current output and use your power supply connected to the load's input to get 3A