SEAFLO 56A Bypass Valve Adjustment to prevent cycling

Поділитися
Вставка
  • Опубліковано 4 тра 2023
  • Available here:
    12V:
    www.amazon.com/dp/B0BXRJJXND
    24V:
    www.amazon.com/dp/B0BXRRFT4P

КОМЕНТАРІ • 16

  • @Portugeezaa
    @Portugeezaa 15 днів тому

    Just wanted to say thank you!!
    This video was instrumental to me sorting my seaflo series 42 pump out and being able to have a shower again! 😂

  • @neilnevis5636
    @neilnevis5636 5 місяців тому +1

    Thank you Sir. My Seaflo 55 is brand new and wouldn't shut off . With your advice a half turn clockwise did the trick. It shuts off now 👌

  • @miztrusa
    @miztrusa Рік тому

    Jus got the 42 series and it did have the cycling issue at low flow and doing exactly what you said to do in this video got mine dialed in to perfection. TY for the video 😊

  • @throughtheeyesofourtribe
    @throughtheeyesofourtribe 4 місяці тому

    Any advice if the pump cuts off at full flow after 15-20 seconds?

  • @Dustin.G
    @Dustin.G 7 місяців тому

    How much current does this pull? (Does it pull anything when its off?)

  • @manfrednemeczek4108
    @manfrednemeczek4108 Рік тому +2

    My Seaflo 55 twitches when off. Every 30-60 seconds it does this. I have confirmed no leaks in the system by isolating the pump. It still does it. Do you have a solution for this problem? Thank you in advance

    • @miztrusa
      @miztrusa Рік тому +2

      Bypass is over adjusted like he said.

    • @DocHoliday-to6kp
      @DocHoliday-to6kp 6 місяців тому

      The one way check valve that allows flow out of pump but not back through it may be dirty or defective.

  • @markc8207
    @markc8207 9 місяців тому

    I have a standard kitchen faucet and I cannot dial mine in. Is it possible that it doesn't work because of the aerator in the faucet?

    • @jzkbbi1
      @jzkbbi1  18 днів тому

      If you have trouble dialing it in, error on the side of a little cycling.

  • @roroalv
    @roroalv 8 місяців тому

    If using with a 1.2 gpm pressure washer, would this help ?

    • @roroalv
      @roroalv 8 місяців тому

      I have the 33series

    • @jzkbbi1
      @jzkbbi1  7 місяців тому

      @@roroalv How is the 33 working out with the pressure washer?

    • @roroalv
      @roroalv 7 місяців тому

      @@jzkbbi1 it does what it needs to do. Performs great however since they’re is very low flow, it shuts on and off constantly when running the pressure washer. No problems however

    • @jzkbbi1
      @jzkbbi1  7 місяців тому

      @@roroalv Perhaps try the 55 pump then. It may be that the variable nature of the 56A is lost on your application. Further, if the 55 still doesn't provide enough flow, you can plumb 2 in parallel to increase flow.