Klein Tone generator/ probe - How to use a Toner The RIGHT way!

Поділитися
Вставка
  • Опубліковано 29 лис 2022
  • amzn.to/3mpsiaZ
    Troubleshoot Like a PRO
    Trace wire
    How to use toner
    Best toner video
  • Розваги

КОМЕНТАРІ • 181

  • @toolsandtactics
    @toolsandtactics  7 місяців тому +2

    ua-cam.com/video/1zH5iY_58Dw/v-deo.html

  • @RobH2
    @RobH2 Рік тому +49

    I can't tell you how helpful this was. I've had the same Klein tracer for a year and have almost thrown it away several times being unable to trace anything. Why would this info about "tuning" the sensitivity not be in their documentation? Go figure! But wow, now I can actually trace. Thank you so much.

    • @toolsandtactics
      @toolsandtactics  Рік тому +2

      Hey, thanks. I'm glad it helped!

    • @sasquatchrosefarts
      @sasquatchrosefarts 9 місяців тому +4

      ​@@toolsandtacticsyou're not a qualified electrician. You just taught your viewers to poke a screwdriver around a live panel. First thing to do is turn off the main, turn on a flashlight, and connect the tone generator to the wire you think it should be.
      I don't even know how you have an electrical credential showing people to shove a screwdriver near live wires inside the panel like that. It's not just one wire at a light switch. If you contact two wires with your screwdriver, you get two legs shocking you, and you can die.

    • @sasquatchrosefarts
      @sasquatchrosefarts 9 місяців тому +3

      ​@@toolsandtacticsalso, if you don't know what the extent of damage is from a short, check resistance with a test leg of wire and a multimeter.
      Old school.
      Kids these days are useless.

    • @Yourengineeringstandpt
      @Yourengineeringstandpt 8 місяців тому

      Yes that is vary helpful I can't imagine using a tracer that's not usefull on a 240 breaker can u show us how to trace 240 v breaker

    • @coltonsides2458
      @coltonsides2458 2 місяці тому

      ​@sasquatchrosefarts thats crazy. I been poking my hands and screwdrivers around in the panel my entire career havemt died yet

  • @aze216
    @aze216 Рік тому +14

    OUTSTANDING!! I was one of the "lotta people" who got this wrong. Thanks for the video. (Note to self) Read the manual next time. This is a HUGE help to me after misusing the toner for years.

  • @davejudd5421
    @davejudd5421 6 місяців тому +4

    Thank you BIG TIME! I can't think of any UA-cam video I've ever watched that has helped me more than this one. There is No mention of tuning the tone volume and watching the light - in the Klein owner's manual. I'm tracing wires in a giant house feeding 105 keypad switches in a Crestron lighting and ceiling fan system. I wanted to scream with all the false readings I was getting. Not anymore! Fantastic job, great video!

  • @tomdailey20
    @tomdailey20 Рік тому +7

    Great video. Bought to trouble shoot. Didn’t know how to fine tune it. Doing my homework. Thanks again for spending the time. Good bless UA-cam..

  • @user-zh7dc2wz2g
    @user-zh7dc2wz2g 7 місяців тому

    Thank you! I have been watching a lot of video, but your is the most helpful on earth! I used to click on neutral on the black clip to trace, not ground, not accurate. I also didn’t know I used to set the highest level, it cause confusion like you say. Thank you!

  • @user-yw2uw6hd5o
    @user-yw2uw6hd5o Рік тому +1

    Im glad i found this video. Im currently tracing a wire for a customer. Cant wait to go back and try it

    • @toolsandtactics
      @toolsandtactics  Рік тому

      Nice let me know if I need to make a different video if you have a question

    • @1percentSolutions23
      @1percentSolutions23 9 місяців тому

      Did it help, what’s the update?

  • @xtaxpayer1
    @xtaxpayer1 27 днів тому +1

    thank you, I made up my mind to buy this unit due to your video

  • @808JuJu
    @808JuJu 11 місяців тому +3

    Do you have to have that exact pen to troubleshoot for things like labeling or can you use any pen with that device

  • @donhozy
    @donhozy 5 місяців тому +2

    That dialing in procceedure for the thoner is a key tip! Thasnk you! Just subbed.

  • @jacobgonzalez4255
    @jacobgonzalez4255 Рік тому +3

    Hi, I'm looking into purchasing a probe/tracer, would you recommend this klein over the fluke variants? Thanks

  • @whitecaps775
    @whitecaps775 10 місяців тому

    Great info, just started with this toner, needed this.

  • @takeniteasyfriend
    @takeniteasyfriend Рік тому +11

    Definitely 👍 the best tutorial on this Klein. Not sure why they don’t have these types of videos on their website. Well done. Thanks

  • @TexansForChrist
    @TexansForChrist 3 місяці тому +1

    Great video. Very helpful. I have that Fluke toner and it works great for me. Reviews on the Klein pointed out that it has weaknesses as well. 2 good choices for sure.

    • @toolsandtactics
      @toolsandtactics  3 місяці тому

      I will say the actual generator for the fluke. Is very nice and I've used them in combination with each other. But the actual wand 4 fluke isn't as good

  • @axpersx9397
    @axpersx9397 3 місяці тому

    I made a joke on your live and you laughed it made my note thanks for the sense of humor!!!🎉🎉subscribed

  • @cwalker7070
    @cwalker7070 Рік тому +2

    You just taught me some new today thank you

  • @sritchie58
    @sritchie58 10 місяців тому +1

    Great I also was one who got it wrong. Going to work tomorrow and work on this. Thank you

  • @marktony4842
    @marktony4842 Рік тому +1

    Awesome video. Really want to buy this toner just convinced me to get this one instead of the old fluke one I used to use

    • @toolsandtactics
      @toolsandtactics  Рік тому

      the fluke 1 is ok, I have it too, but this 1 has the light!Ffor a while I used a fluke toner and klein probe and discovered the light.. and what a difference!

    • @toolsandtactics
      @toolsandtactics  Рік тому

      also thanks !

  • @sandiegodan
    @sandiegodan 11 місяців тому +1

    Well sort of. Sensitivity varies by distance of the run. You may still need to turn up the sensor if the receptacle if far away from the breaker panel if you want to use the light.

  • @danieldavis7675
    @danieldavis7675 Рік тому +2

    Great job illustrating.

  • @victorrobles720
    @victorrobles720 8 місяців тому +1

    Great videos!! Learned something new for sure!!

  • @Swampytheroot
    @Swampytheroot 28 днів тому +1

    Looks like I need to upgrade my 20+ year old toner rather than look for videos on how to repair it.
    Nice presentation.

  • @George89704
    @George89704 5 місяців тому +1

    I started doing this it really dose help, thank you

  • @McmM-cv9sb
    @McmM-cv9sb 4 місяці тому +1

    very good video thanks that was very helpful and a safe way to work.

  • @PhillyFixed
    @PhillyFixed Рік тому +2

    Very helpful, Robert. Thanks!

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      hey! thanks how u been!?

    • @PhillyFixed
      @PhillyFixed Рік тому +2

      @@toolsandtactics good! Real busy around the house, and so not real busy on UA-cam, unfortunately...

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      @Philly Fixed yeah I know how that goes! Best wishes buddy!

  • @MrChuy1000
    @MrChuy1000 6 місяців тому

    😊 thanks loved the video 😊

  • @michaeldahan2036
    @michaeldahan2036 Місяць тому +1

    Very useful. I have the same tone generator and was not using it correctly. Now I can trace . Will this method work if the wire was s behind a wall

  • @beavisboots
    @beavisboots 7 місяців тому +1

    Im considering this toner for some old knob and tube trace and replace. Understand I need a good ground for it to work. Found some 14/3 that was used from the panel to a junction box where tw seperate runs of knob and tube start. They used the red wire on one breaker as a feed and the black as another. It was hidden pretty well but when going to insulate the attic space, we found knob and tube. 🤦 Would you recommend this tiner for such a job?

  • @ebaum1000
    @ebaum1000 3 місяці тому +1

    So I have a customer where they have a leak in their copper line set for the hvac system. But they had an addition done in the past. So I don’t know where the copper runs. Can I use this to trace the copper line? How would I do this? The copper is already grounded.

    • @toolsandtactics
      @toolsandtactics  3 місяці тому

      You have to disconnect it to isolate it
      This toner might not help

  • @ennuied
    @ennuied Рік тому +1

    Thanks for that.

  • @getoutdoors8718
    @getoutdoors8718 Місяць тому

    Great video! Can this tool trace a neutral wire in a dedicated circuit in the panel? This video is one of the best I’ve seen on the practical use of a tone generator to trace electrical wire in walls and receptacles for diy

  • @mpcp27
    @mpcp27 9 місяців тому +1

    Thanks for the tips. Question what exactly are you doing at 5:37...Are you trying to adjust the sensitivity of the probe? Because i checked the manual of that klein probe (VDV500-820) for link you provided, and supposedly all those buttons do is adjust volume. I don't see anything about sensitivity .

  • @markharris9647
    @markharris9647 Рік тому +1

    If the house is not grounded can you make a video on how to use a ground from the stove

    • @toolsandtactics
      @toolsandtactics  Рік тому

      Yes, but just an alligator clamp, or a few will work on the oven hinge. Open the door, there it is, thanks. I'll make a video though

  • @hediervarelamedina987
    @hediervarelamedina987 6 місяців тому +1

    The video is good, respectable and in terms of tracing lines in short circuit, the Klein Tools ET450 is much more precise because you can trace even over sherock walls with or without power, and even if you have lines on the ground. example in the garden or patio. This tracer is good but an error and if the circuit to God tracer is energized. Otherwise, as I said, the video is good.

    • @toolsandtactics
      @toolsandtactics  6 місяців тому

      thanks! ill check out the Klein Tools ET450

  • @Dan-ger82
    @Dan-ger82 10 місяців тому

    Can you put the toner on a live circuit for instance if you looking for a breaker but the panel isn't labeled and you can't just flip breakers on and off due to being in industrial plant? Also voltage too much to just short out safely. I was wondering if the voltage would fry the toner or not. Usually it's 480v but figured you could attach toner to one leg but would be 240v on it to neutral. Every video I see has toner on dead circuit.

    • @toolsandtactics
      @toolsandtactics  10 місяців тому

      I don't think it'll break the toner but it won't work just hums loud
      Not sure about higher volts

    • @pwhs8
      @pwhs8 7 місяців тому

      Klein sells a circuit breaker tester

    • @Dan-ger82
      @Dan-ger82 7 місяців тому +1

      @@pwhs8 yeah I found the Klein ET450 advanced circuit breaker kit that can be used on live 480v circuits

  • @user-hm1cq9wr2o
    @user-hm1cq9wr2o Рік тому +1

    I have a HOT ground wire (120 volts) on a small light/outlet circuit. Breaker tripped occasionally, now it instantly trips. Should I use your suggestion with the extension cord and plug it into a different/good circuit? Then would I be able to trace to find the short behind drywall? Thanks for any suggestions - and GREAT tutorial!

    • @toolsandtactics
      @toolsandtactics  Рік тому

      Yeah to trace all parts out so you know where to look use a good ground from the extension cord and try that but most likely either 1 of 2 are very common 1 fed from a gfci ( maybe this is an outside light) or 2 most common open the switch that controls it and you will find a melted mess and ground touching the black wire or hot terminals or behind the panel cover a melted mess
      Your gona have a hard time Traci g it out if the hot is touching the ground
      with a multimeter ( in continuity) so if the black ( hot) goes to ground this could get tricky check ever box you suspect that circuit to be in commonly a long run will need to be replaced
      I can make a short explaining what to do if you want to Email me a basic drawing /diagram of the room light and stuff

    • @user-hm1cq9wr2o
      @user-hm1cq9wr2o Рік тому +1

      @@toolsandtactics Thank you for the advice and the offer to make a short! First I'll try opening the wall up right where I found the Hot ground wire first, and check everywhere else I can (switches, outlets and fixtures). I think with your suggestions I might be able find that... "melted mess", hopefully it's close to where I found the Hot ground. If my investigation draws a blank, I might have to take you up on your kind and generous offer. It's going to be a couple of days before I can get back on it, but I'll certainly keep you updated. This might help someone else too. THANK YOU again!

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      @@user-hm1cq9wr2o thanks good luck and happy hunting

    • @user-hm1cq9wr2o
      @user-hm1cq9wr2o Рік тому +1

      @@toolsandtactics I apologize for the late update! I was able to find the short. Luckily it was very close to the switch that fed another room. I just traced it around to the next outlet it fed, opened up the drywall and bingo! There it was, FRIED. It was burnt bad, burned all the way through a 14/3 Romex cable. It appeared to be a mouse had chewed through it, but not sure... as there was no mouse carcass. Anyhow, THANKS for helping me out with this scary situation. Best to you and your channel.

    • @toolsandtactics
      @toolsandtactics  Рік тому

      @user-hm1cq9wr2o that's great! This tool helped? That's awesome Thanks for the support!

  • @pondacres
    @pondacres Рік тому +1

    Thank u kind sir, this helps this here dummy who always fails in reading the instruction manual. :))

    • @toolsandtactics
      @toolsandtactics  Рік тому +2

      I hate instructions worthless lol

    • @pondacres
      @pondacres Рік тому +1

      @@toolsandtactics Man sorry to bug, but a quick question. I've got a dead outlet, and having a hard time tracing wires with this tool. When tracing hot wire to panel, I can't pick up a tone there at all, but also having a hard time just even tracing the wire behind wall in conduit. I got the red clip on the hot wire and the black clip on ground wire, so I think that's right. Also, how to trace a neutral wire on, since attaching clips to it and the ground wire will show continuity?

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      @@pondacres conduit acts as a shield you cant trace wire in conduit only non metallic, flex, romex, cable, cords

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      also make sure that the ground wire you attached to has a true reference might be better to attach the black wire something else grounded

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      how is the circuit laid out? you can also email me conductivewood@gmail.com

  • @whitetiger8652
    @whitetiger8652 8 місяців тому

    Great video.

  • @danielstakes4813
    @danielstakes4813 2 місяці тому +1

    Oh lord not a stablok fpe panel!! Hopefully insurance company doesn’t see this 😂

    • @toolsandtactics
      @toolsandtactics  2 місяці тому

      It could be worse, could be at your house🤣

  • @davidprivette8898
    @davidprivette8898 10 місяців тому +2

    The fluke 3000 is a good tester. If you’re toning out a line all you have to do is touch the line with your hand while pressing your toner if you have the correct line it will make a sound. I’ve never had an issue.

  • @haroldpalmsesq2506
    @haroldpalmsesq2506 Рік тому +1

    Good info

  • @Yourengineeringstandpt
    @Yourengineeringstandpt 8 місяців тому +1

    How to ck 240 breaker off a p tac unit find the breaker from a wired 240 unit thanks

  • @jimbo7042
    @jimbo7042 3 місяці тому +1

    Kind of wish I got this instead of a super duper expensive ideal circuit tracer

    • @toolsandtactics
      @toolsandtactics  3 місяці тому

      That ideal 1 finds circuit breakers and does it well, but yeah, this toner is an excellent value

  • @ricoallblack
    @ricoallblack 5 місяців тому +1

    Some meters have a disconnect that can be switched off so you can safely work in the breaker box

  • @billsmopars4927
    @billsmopars4927 7 місяців тому

    Good video. Now all of a sudden my tone generator won't stay on. darn.

  • @mindsweepa442
    @mindsweepa442 Рік тому +1

    Would this work through walls? I’m trying to trace a mystery light switch in my house. I’ve already checked all the obvious stuff. Breakers off for the switch and nothing else in my house turned off. Last resort is to just see if I can follow the wire through the wall.

    • @Hitman.13.
      @Hitman.13. Рік тому

      Did you check if that switch controls any nearby receptacles ?

    • @toolsandtactics
      @toolsandtactics  Рік тому

      Yeah It can. Depends on material of wire and how far away but yes

    • @ScrewballMcAdams
      @ScrewballMcAdams 10 місяців тому

      I’m curious if you ever found what that mystery switch controls. I’ve got a couple of them in a 30 yr old house I recently moved into. I suspect one was intended to control a ceiling fan light that’s no longer there; and the others I suspect were intended to control outlets installed inside multimedia cabinets back in the day when ppl hid their ginormous stereo components in cabinets.

  • @lennyott1800
    @lennyott1800 Рік тому +1

    learned something

  • @rey5905
    @rey5905 Рік тому

    Nice

  • @s.pursell8901
    @s.pursell8901 9 місяців тому

    I'm sure this was very informative if I didn't need to turn my volume down because of the constant beeping. What was the purpose of having to record right next to the unit the entire time. Your voice was further away, so it focused on the alarm. Anyway, I appreciate the tutorial. Best of luck.

  • @nickmillionn7319
    @nickmillionn7319 Рік тому +1

    Will this work for smoke alarms that have no true ground? The ground are just wire nutted in the box

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      Yeah You don't have to use the ground from the circuit just a good Ground source like you can use an extension cord and plug some scrap wire into the ground prong and put the black clamp on that and the red clamp on the black to trace out the other wires on the smoke detector cable conductors

    • @nickmillionn7319
      @nickmillionn7319 Рік тому +1

      @@toolsandtactics great thank you. There’s a break in the wire coming from the panel to the first smoke alarm. So hoping to set up tester at the panel and find the broken wire somewhere behind the ceiling wall. Thank you

    • @toolsandtactics
      @toolsandtactics  Рік тому

      @@nickmillionn7319 for best results disconnect the ground on the romex from the panel completely, attach the black clamp from the toner to the ground bar in the panel and alternate the red clamp from the black to the white on the romex

    • @toolsandtactics
      @toolsandtactics  Рік тому

      @@nickmillionn7319 YOU COULD ALSO, 1 WITH POWER OFF AND FULLY DISCONNECTED FROM THE PANEL BREAKER ECT JUST THE ROMEX IN YOU HAND you could first check to se if any of the conductors ring out continuity to ground
      2 disconnect the other detectors from the daisy chain too and verify that they ''ring clear'' then intentionally ground the disconnected romex to the first smokey and ring them out
      but you probably already did that
      ( meaning not unintentionally grounded ) (sorry if this is basic im just being thorough lol)

  • @jimbo7042
    @jimbo7042 3 місяці тому

    This is a federal Pacific panel, not the best, but obviously still works. Yeah you better test that a bunch of different ways before you confirm it still works

  • @SudburyMan
    @SudburyMan Рік тому +3

    FPE panel... So that could have ended in a short with those breakers not tripping due to design failures.

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      had the diagonals ready if it welded 🤣

    • @SudburyMan
      @SudburyMan Рік тому

      @@toolsandtactics 😂 I absolutely hate touching those panels. Although easy money for a replacement 🤔😏

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      @James Makay yeah 1 of the companies I worked for had customers sign a waiver 💀

    • @RailBuffRob
      @RailBuffRob Рік тому +1

      Fire Pacific, Federal Catastrophic.

  • @poopie706
    @poopie706 7 місяців тому +1

    As a point of interest, while you're speaking you have the volume of the probe turned up so high it resonates over your voice.

    • @toolsandtactics
      @toolsandtactics  7 місяців тому

      Yeah, thanks this was live so not ideal studio conditions

  • @byronwesleyb7267
    @byronwesleyb7267 Рік тому +9

    The sound quality here....my god. The tone alarm sounds like a nuclear bomb going off compared to narration

    • @toolsandtactics
      @toolsandtactics  Рік тому

      Thanks! I will keep that in mind for a remake

    • @LuisMartinez-fr9gq
      @LuisMartinez-fr9gq Рік тому

      Hello my friend, i want to ask you one question do you think i can trace a wire in the car with this tool, if it's possible can you help me please, how to setup the tool to find a wire, does the battery has to be connected or disconnect. Thank you in advance.

    • @toolsandtactics
      @toolsandtactics  Рік тому

      @Luis Martinez hey, yeah disconnect the battery, and before you hook anything up try toning ( with a Multimeter the wire in question to the bare metal chassis of the car to see if it's shorted if it is the toner won't help you very much
      If its shorted you wont get a great signal you can leave the toner hooked up and listen to see if the sound changes when you cut or remove the wire you suspect , to speed things up
      Hope that makes sense

    • @LuisMartinez-fr9gq
      @LuisMartinez-fr9gq Рік тому +1

      @@toolsandtactics thank you for responding promptly, i sincerely appreciated, i am going to try the way you say, i will let you know tomorrow. Again thank you.

    • @toolsandtactics
      @toolsandtactics  Рік тому

      @Luis Martinez thanks good luck how old is the car lights or what?

  • @NoelCEnriquez
    @NoelCEnriquez Рік тому +2

    you forgot to explain why the black clip has to be connected to ground

    • @Ron2600_
      @Ron2600_ Рік тому +1

      That should boost the signal strength of the tone generator.

  • @choppmonster7
    @choppmonster7 9 місяців тому

    Well now I know to buy this now. The whole front side of my house has no power and I think it’s due to the light switch near my front door.

  • @sodelicious29
    @sodelicious29 4 місяці тому

    U should redo the video so you're easy to hear. With the sirens so loud I couldnt hear u very much

  • @vicpetrishak7705
    @vicpetrishak7705 Рік тому +1

    Federal Pacific has burned many houses down ! 5/17/23

  • @mcs-21277
    @mcs-21277 Рік тому +2

    This toner isn’t that great. It shuts off on its own. The probe turns off after 10 minutes. Uses 4 AA batteries. The fluke uses 9v. Get the fluke one

    • @toolsandtactics
      @toolsandtactics  Рік тому

      I like this one because the toner itself has a light and seems I never have a good 9volt no mater how may spares I try to stowaway lol

  • @tha531
    @tha531 11 місяців тому

    "Make sure this breaker is in the off position..."??? huh? If you already knew which breaker to turn off....🤣

    • @toolsandtactics
      @toolsandtactics  11 місяців тому +1

      It's not a circuit identifier it's a toner you can't use it with electricity on you would usually turn off ALL the breakers to find the 1
      But then we wouldn't have any lighting for the video hope that helps thx

    • @tha531
      @tha531 11 місяців тому

      @@toolsandtactics that's the point, you're using the wrong tool for the wrong job!

  • @thatrealsquezyboy7226
    @thatrealsquezyboy7226 Рік тому +1

    Couldn’t take the beeping had to close video

    • @toolsandtactics
      @toolsandtactics  Рік тому

      That's fair! It's always a Risk showing that thing thx

  • @anthonyiodice
    @anthonyiodice Рік тому +2

    Federal breakers burn houses ded!😊

    • @toolsandtactics
      @toolsandtactics  Рік тому

      I would say.. zinsco do federal don't trip so there has to be something wrong with the wiring first... zinscos( aluminum bus) arc at random for no reason other than they hate your house and want to make it ash so in short I think federal are bad but zinsco Sylvania gte are worse and deserve more attention thanks for comming to My ted talk lol

  • @kalimont6003
    @kalimont6003 Рік тому

    Better use another equipment not klein, at least on this that tracer isn't good. I wont buy that. Probably use a 24v light.

  • @jesterraj
    @jesterraj Рік тому +2

    the tactics way is to use your fingers to see how damaging it can be......lol

  • @rWirthlin1983
    @rWirthlin1983 Рік тому +1

    Could of been a very helpful video if not deafened by the sound 90%of the time. Half the stuff yo say can’t be heard cause you have to turn the vol down so low to not go deaf from the tone. So this is not a useful video on you tube lil common sense goes a long way. Maybe find some before your next video

    • @toolsandtactics
      @toolsandtactics  Рік тому

      Thanks one of my first videos with a bad editor I will remake soon

  • @josephvotta6698
    @josephvotta6698 7 місяців тому

    Your tool table is a mess! Did you just dump your whole bag of tools on the table?

  • @dylan0819mcbean
    @dylan0819mcbean Рік тому +1

    People dont be worried about getting shocked on an outlet, even a 20 amp outlet wont kill ya. Just shake it off and get back to work

  • @PaulHenreid
    @PaulHenreid Рік тому

    The most annoying audio i have ever heard

    • @toolsandtactics
      @toolsandtactics  Рік тому

      I did warn you lol I tone it out if I didn't it would be hard to use this

  • @genevatungate1006
    @genevatungate1006 6 місяців тому +1

    This was no help at all, just annoying

  • @Misfit6mm
    @Misfit6mm 5 місяців тому

    Blah blah blah

  • @skunkbri
    @skunkbri Рік тому +1

    Dude that toner is garbage

    • @toolsandtactics
      @toolsandtactics  Рік тому +1

      Which 1 do you like?

    • @skunkbri
      @skunkbri Рік тому +2

      Lately I’ve been using that fluke toner not the one that they used to sell at Home Depot the blue one I’m talking about, but the one that had the numbers on it with the light but right now I Literally just received the ET 450 Advanced circuit tracing kit.. I’m not trying to shit on your video or anything like that I just use that toner and I know it only tones up to 200 feet I believe I know there’s two different ones I might be mistaken that one for the cheaper one

    • @toolsandtactics
      @toolsandtactics  Рік тому +2

      @skunkbri that's cool, some of the higher end ideal 1s work amazing
      This is the best non hand tool klein makes usually the meters and stuff from klein is garbage compare to others for the price. Thanks for the input!

    • @LuisMartinez-fr9gq
      @LuisMartinez-fr9gq Рік тому

      Excuse me, one question is this tool good for tracing a short on a car, cars work with DC-(direct current). Do you think i can trace a wire with this tool he is showing. Please help me, also does the battery has to be connected or disconnect, thanks in advance...

    • @ennuied
      @ennuied Рік тому +1

      @@LuisMartinez-fr9gq A late reply but this tool can’t be used with energised circuits. It’s like a contactless continuity tester.