Double Regulating Valve | DRV | in Urdu/Hindi

Поділитися
Вставка
  • Опубліковано 24 січ 2025

КОМЕНТАРІ • 84

  • @TanweerAhmed
    @TanweerAhmed  3 роки тому

    Automatic Balancing Valve link: ua-cam.com/video/S370MfPwxg0/v-deo.html

    • @KhalidKhan-fx9ph
      @KhalidKhan-fx9ph 2 роки тому +2

      Three way valve chiller which are youse

    • @TanweerAhmed
      @TanweerAhmed  2 роки тому +1

      What do you want to say?

    • @asgharahsan003
      @asgharahsan003 Рік тому

      ​@@TanweerAhmed He wants to say that what is the purpose of using 3-way valve in chilled water line ?

  • @RehanKhan-fr4kg
    @RehanKhan-fr4kg 6 місяців тому +1

    Nice explained sir
    U are a gem I am preparing watching your video for hvac engineering

  • @m.raheel110
    @m.raheel110 5 місяців тому +1

    Ap ki video boht informative thi sir jzak allah

  • @aqeefshaikh5447
    @aqeefshaikh5447 3 роки тому +3

    Jazakallahu khaira. your videos are really helpful to understand deeply.

  • @kabeerabids
    @kabeerabids 3 роки тому +1

    Jazakallah....Thanks for the explanation...you have strong knowledge about the subject

  • @MdJuber771
    @MdJuber771 4 місяці тому +1

    Bhut khoob sir

  • @SadathUllah-d5k
    @SadathUllah-d5k Рік тому +1

    Great explanation!

  • @hassanmrao1466
    @hassanmrao1466 Рік тому +1

    good explanation sir

  • @mohammedwaseemahmed5946
    @mohammedwaseemahmed5946 5 місяців тому +2

    Please post a video of difference between DRV and PICV.Also can we balance FCU with only DRV ?

    • @TanweerAhmed
      @TanweerAhmed  5 місяців тому +1

      Watch my other videos of PICV and balancing valve for deep understanding

  • @akmalakbar6881
    @akmalakbar6881 5 місяців тому +1

    Very nice sir

  • @shadabrehman709
    @shadabrehman709 3 роки тому +1

    Very informative. Jazakallah

  • @asifsajjad6085
    @asifsajjad6085 2 роки тому +1

    Good very helpful

  • @Ehtesham147
    @Ehtesham147 2 роки тому +1

    Thank you so much for your help.

  • @nomibhatti2400
    @nomibhatti2400 2 роки тому +1

    Very very nice sir g

  • @farhatalisethar9097
    @farhatalisethar9097 3 роки тому +1

    Great Ada

  • @ziyamasad2709
    @ziyamasad2709 3 роки тому +1

    Jazakaallah bhai... please provide us the details of standard valve package connections in AHU & FCU including btu meter, inlet which valves are used & outlet which valves are used for constant & vfd type flow...

  • @subhashillikode8484
    @subhashillikode8484 3 роки тому +2

    Good explanation, expecting more and let me known which is the good book to learn

    • @TanweerAhmed
      @TanweerAhmed  3 роки тому

      Thanks, these are taken from catalogue of equipment

  • @mohammadabdulaleem1101
    @mohammadabdulaleem1101 3 роки тому +2

    Sir why we fix drv in return line please answer

    • @TanweerAhmed
      @TanweerAhmed  3 роки тому +1

      Normally it is installed on the return line because of following reasons.
      1. ASHRAE Recommendations.
      2. The coil of the unit should be flooded in case the valve is closed.
      3. With a control valve on the return side, the water is at a higher pressure through the coil, reducing off gas, thereby lowering dissolved oxygen content. Lower dissolved oxygen extends equipment life by minimizing the air entrapment.
      4. If it is a hot system, some manufacturers have temperature limitations on the actuators. If there is a180°F limit on the actuator (common to some actuators), the return side is preferred as it will operate at a cooler temperature.
      5. If it is a cold system, it is always better to have less thermal breaks on the colder side (e.g.42°F water) than on the warmer return side (e.g.,56°F water). The return side installation reduces sweating on the electronic actuator, which is more prone to failure when wet.

    • @mohammadabdulaleem1101
      @mohammadabdulaleem1101 3 роки тому +1

      @@TanweerAhmed thanks sir.. quick response. Jazakallah

    • @TanweerAhmed
      @TanweerAhmed  3 роки тому

      Welcome

  • @AhmedAhmed-kp6ms
    @AhmedAhmed-kp6ms 3 роки тому +1

    Tanveer pa g, plz guide me about fcu fresh air supply control & location of it & also control fcu air throw control.

  • @asifjutt8824
    @asifjutt8824 3 роки тому +1

    v good sir

  • @exploreskillswithdawoodmasih
    @exploreskillswithdawoodmasih 3 роки тому +1

    Helpful.

  • @ranadastgir3690
    @ranadastgir3690 3 роки тому +1

    DRV FCU K IN LINE PAR LAGTY HAN YA OUT PAR. ???

  • @qumartanweer6589
    @qumartanweer6589 Рік тому +1

    Aw sir aik drafting video banae small villa ka hvac ka.

    • @TanweerAhmed
      @TanweerAhmed  Рік тому

      I don't understand. What you want to say

    • @qumartanweer6589
      @qumartanweer6589 Рік тому

      @@TanweerAhmed hvac drafting video for G+1 2 floor like how to draw duct, fcu ahu Or other components related to hvac like eccentric reducer concentric reducer elbow

    • @TanweerAhmed
      @TanweerAhmed  Рік тому

      @@qumartanweer6589 Sorry, I don't know drafting work. AutoCAD draftman know this work.

    • @qumartanweer6589
      @qumartanweer6589 Рік тому +1

      @@TanweerAhmed ok Sir thanku, aapki videos se bahut help hote hai Thank a lot

    • @TanweerAhmed
      @TanweerAhmed  Рік тому +1

      Welcome

  • @ITR30
    @ITR30 12 днів тому +1

    PICB AND DRV both are same please reply

    • @TanweerAhmed
      @TanweerAhmed  8 днів тому

      My both videos are available on these topic, watch & understand

  • @gangavaramimran
    @gangavaramimran Рік тому +1

    Purpose installing Drv in Chilled water return main line

    • @TanweerAhmed
      @TanweerAhmed  Рік тому

      Watch this video, I hope that you will understand

  • @tajkhan-jm9fe
    @tajkhan-jm9fe 3 роки тому +1

    How to balance chilled water with metter

  • @gufran548
    @gufran548 3 роки тому +1

    Assalamualaikum sir
    If u have CCU unit(PAC) unit vedio please send link

    • @TanweerAhmed
      @TanweerAhmed  3 роки тому

      Watch in HVAC playlist i.e. package FAHU unit

  • @abdul10375
    @abdul10375 2 роки тому +1

    Chilled line k ooper red color kyun liya jata he

  • @PawanKumar-mw5uv
    @PawanKumar-mw5uv 3 роки тому +1

    I need your help for some license query for global trading

  • @merajmoqueem5828
    @merajmoqueem5828 3 роки тому +1

    Types of balancing

    • @TanweerAhmed
      @TanweerAhmed  3 роки тому

      What do you want to say?

    • @merajmoqueem5828
      @merajmoqueem5828 3 роки тому +1

      I want to know how many types of balancing valve?

    • @TanweerAhmed
      @TanweerAhmed  3 роки тому

      I have explained in this video and also will make more videos

  • @ijazahamed1749
    @ijazahamed1749 3 роки тому +1

    What is the function of double regulating valve. Can u explain in English

  • @PawanKumar-mw5uv
    @PawanKumar-mw5uv 3 роки тому +1

    Messenger I'd or anything by which I can contact you it is big project pls discuss with me

  • @imamimam994
    @imamimam994 2 роки тому +1

    Assalamu aleikum bhai jaan aapka mo no Chahiye

    • @TanweerAhmed
      @TanweerAhmed  2 роки тому +1

      Join my Telegram group and its link is given in each video's description and also community tab

  • @muhammadibrar4515
    @muhammadibrar4515 2 місяці тому

    Your lecture is full of confusion....