EG4 6000XP Off-Grid Inverter - Overview of Features, Installation, Paralleling and Load Test

Поділитися
Вставка
  • Опубліковано 20 лип 2024
  • Learn more at: signaturesolar.com/eg4-6000xp...
    Join us as we explore the EG4 6000XP's features and a load test, proving it's the go-to solution for efficient off-grid power.
    With a robust 6000W output, scalability up to 16 units, and built-in switchgear, it's a cost-effective powerhouse for energy independence. Enjoy top-tier efficiency, including a 99% MPPT efficiency, and easy monitoring through the EG4 app. The all-in-one design, dedicated generator connection, and certifications like UL 1741 make installation a breeze. Energize your journey with the future of off-grid energy!
    *** Revision to battery torque specs since recording of this video: In section 5.6 of the manual, 'Battery Cable Connection,' Step 4 - note that torque ratings for this step have been revised to 97-106 in-lbs (11-12 Nm) per connection.
    Please reference the current manual on our website during the installation process: signaturesolar.com/eg4-6000xp...
    Be a part of the solar revolution with Signature Solar!
    --------------------------------------------------------
    Recommended Solar Panels: signaturesolar.com/shop-all/s...
    --------------------------------------------------------
    Recommended Batteries:
    EG4 PowerPro: signaturesolar.com/shop-all/b...
    EG4 LL: signaturesolar.com/eg4-ll-lit...
    EG4 Lifepower4: signaturesolar.com/eg4-lifepo...
    --------------------------------------------------------
    Need additional wiring or system components for your DIY Solar Project?
    signaturesolar.com/shop-all/s...
    0:00 Intro
    0:53 All-In-One Inverter
    2:04 120V/240V Unit
    2:49 Battery/MPPT Efficiencies
    3:45 Wifi Connectivity
    4:15 Certifications
    4:33 Additional Features
    5:33 Installation Steps
    13:21 Paralleling
    19:58 Load Testing
    24:00 Conclusion
  • Наука та технологія

КОМЕНТАРІ • 262

  • @JGoodwin
    @JGoodwin 7 місяців тому +12

    Appreciate these information dense videos. Normally watch videos at 2x speed. Had to slow it down to 1x and still went back to rewatch certain parts. This is great!

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      Glad this was helpful! Let us know if you have any questions on your solar journey!

  • @dswaggins2464
    @dswaggins2464 7 місяців тому +14

    Hey just did this tonight. Was pretty easy. Great job with this video as always. This lady always does a good job explaining every step.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      Glad you enjoyed the video! Thank you for your purchase! Let us know if you need any assistance along the way.

    • @VinceBadovinatz88
      @VinceBadovinatz88 6 місяців тому

      I know she did a great job

  • @carlosschmidt6035
    @carlosschmidt6035 7 місяців тому +4

    Excellent demonstration of the power of the EG4 6000 XP

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      So happy you enjoyed the video Carlos!

  • @CountryLivingExperience
    @CountryLivingExperience 7 місяців тому +2

    Nice work! I appreciate this video and Sig Solar stepping up their video quality.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому +1

      We appreciate the feedback! Happy you enjoyed the video!

  • @vincentstouter449
    @vincentstouter449 7 місяців тому +3

    Thank you for an excellent presentation. The XP6000 is excellent in that it provides a complete two phase solution offering both economy for the first unit coupled with seamless future expandability. 😎

  • @publicviewmedia4700
    @publicviewmedia4700 2 місяці тому

    🌈❤🧡💛💚💙💜 I am one VERY satisfied customer of Signature Solar. I live off grid in a small house, and my first inverter was an 8K that gave me many issues. Signature Solar staff and tech support were amazing. Knowledgeable, patient and they helped me to troubleshoot the issues involved even though I started from knowing zero about Solar Electrical Systems. When it became clear the inverter was faulty, they stepped up and allowed me to replace it with the 6000XP inverter featured in this video. What an amazing and efficient inverter. I now have virtually all of the 110/220v power that I need to heat, cool and run all my electrical needs. Signature Solar was completely accountable for seeing that my issues were resolved and leaving me with a great inverter. Thank you Signature Solar for your great support, great company, and great customer service staff.

    • @SignatureSolar
      @SignatureSolar  2 місяці тому

      Thank you so much for this feedback!! Please don't hesitate to reach out for any support in the future!

  • @springton
    @springton 7 місяців тому +1

    Nice job Kelly.... can't wait for my pair to arrive!! Would be nice to have monitored the output power while adding the appliances.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому +1

      We appreciate the suggestion! Let us know if you need any assistance once your unit arives!

  • @Roll2Videos
    @Roll2Videos 7 місяців тому +2

    Great looking product, I will be considering these when I build out my system. Thanks

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      Let us know if you need any assistance along the way! We are happy to help.

    • @Roll2Videos
      @Roll2Videos 7 місяців тому

      @@SignatureSolar I will, It will make great content for my YT channel. Thanks Sig.

  • @Aubatron
    @Aubatron Місяць тому

    This is one of the best presentations I’ve ever saw, very well done. I learned a lot, thank you.

  • @jasonkrug9000
    @jasonkrug9000 7 місяців тому +3

    Just ordered 2 of these with 2 power pro batteries.
    It would be great if you could show us the loads as you turn appliances on to see exactly what the system is putting out.
    Also I’d love to see how you wired that main panel box up for the loads. Very clean install. I’m off grid with no grid input. Will only have backup generator input with my setup.
    Thanks for the video.

    • @JB-xl5kg
      @JB-xl5kg 7 місяців тому

      I too would love to see the panel / load wiring set up for these units. I just purchased two to be installed in series and would love to know the best configuration for bringing the AC out, neutral ground setup, and generator input sizing. You said in the video that a 9000 watt generator would be a good option but the manual said it would need to be 150% larger than the total inverter size. In parallel, two of these inverters would equal 12000 watts which would put the generator sizing at 18000 watts. I currently have a Kohler 12k RES off grid auto start/stop generator and I am concerned this would be too small to supply power for charging the battery bank and the load at the panel. Let me know what you think. Thank you!

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      Thank you for the suggestion! I will pass it along to our team!

  • @hendersonsobers396
    @hendersonsobers396 6 місяців тому

    Loads of great information. Thank you for this.

  • @hippiewithacowboyhat
    @hippiewithacowboyhat 7 місяців тому +2

    Super informative. Very well done, young lady.

  • @GavinStoneDIY
    @GavinStoneDIY 7 місяців тому +2

    Great job on this video. Very well done.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      Thanks! We are happy you enjoyed it!

  • @TRYtoHELPyou
    @TRYtoHELPyou 7 місяців тому +1

    very well put together! thanks for sharing.

  • @jodajackson4489
    @jodajackson4489 4 місяці тому +1

    These 6000XP units look like a great solution in either stand alone or parallel configuration. Great demo. However, as I understand it, the spec requires something like 6 inches on either side of the inverter, maybe 7 (I’d have to check the manual to be sure). The demo setup might have that space between the two inverters but on the other side of either. I’m guessing there were some space constraints but either way it looks good

  • @tomspencer8717
    @tomspencer8717 7 місяців тому +1

    I have two Sungold 2400w inverters 24v running now and going to build a cabin in MO. That inverter would be nice swapping too. Can only afford one right now, my problem would be getting a second in a year or so and find out discontinued, this what happens seeing with inverters, here today gone tomorrow. On disability so two right now is not an option. Might call this week, thanks great video kind of made my mind up from the Sungold 8k one.

  • @memyselfandi8544
    @memyselfandi8544 6 місяців тому +1

    Question regarding the bypass. Do I understand this correctly, you get 3k watts load per leg, from battery power except under generator power, you get an additional 1,800 watts for a maximum of 4,800 watts. And if you have grid power input, you get an additional 3,000 watts per leg for a maximum of 6,000 watts per leg using both battery and grid capacity together?

  • @paul.phillips
    @paul.phillips 7 місяців тому +1

    How does the rapid shutdown impact the breakers on the batteries? Are they triggered via communication cables? Does this only work with the EG4-LL 2nd gen or 1st gen batteries also? I'm going to have to replace my 8Kw Growatt with 2 of these 6000XP's next year. Thanks for the video content, very helpful!

    • @SignatureSolar
      @SignatureSolar  6 місяців тому +1

      When using supported EG4 batteries in closed-loop communications with the inverter, the RSD also initiates ESS Disconnect as required by NEC code

  • @OrtexVideos
    @OrtexVideos 2 місяці тому

    You guys are the GOATS!!

  • @HandfulOfTranquility
    @HandfulOfTranquility 6 місяців тому

    The air compressor is a decent load, but maybe you could set up a home furnace with like a 1hp blower on it. I think the air handler blower may create a longer overcurrent and I imagine many people would be very interested in being able to fire up their 120v propane furnace with this unit. Any first hand experience running a furnace with blower on it?

  • @EastTexasHomestead
    @EastTexasHomestead 7 місяців тому

    I love my 6000EXs but these look so much better!

    • @GavinStoneDIY
      @GavinStoneDIY 7 місяців тому +2

      These would cut your idle consumption by a massive amount. I believe you have 3 of the 6000ex’s? That’s around 360 watts! With 3 of these you’d be around 150 watts total consumption. So less then half.

    • @EastTexasHomestead
      @EastTexasHomestead 7 місяців тому

      That would be a huge savings. My one concern is that these are HF inverters and I’m not sure how they would do with my well pump. I know they show the air compressor starting up here but it’s probably empty, which makes a difference as far as I understand.

    • @GavinStoneDIY
      @GavinStoneDIY 7 місяців тому

      @@EastTexasHomestead it’s hard to say because you have a real beefy well pump. I think they’d do fine with it. These are actually extremely good with surges.

    • @EastTexasHomestead
      @EastTexasHomestead 7 місяців тому

      @@GavinStoneDIY I've seen your videos, and I think you're right. We may be doing a side-by-side sooner than later. ;)

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      These are some nice looking units! Glad you like them!

  • @bellis229
    @bellis229 7 місяців тому +2

    Great video. Has me thinking of it in a 230v deep well backup UPS system at that price point. In the video you tested inrush from the compressor on a single 6000xp at 92.8 amps. Was that a 240v compressor ? It looks to be so from the info I could gather on the 5.5hp 30 gallon Craftsman compressor.
    Our pump is a 1.5hp with inrush measured at 51.35 amps then continuous 11 amps at 230v.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому +1

      The compressor in the video is a 120V compressor. We have a 240V one that does 86 amps a leg and the 6K will start it.

    • @bellis229
      @bellis229 7 місяців тому

      Great news! We ordered the 6000XP with 2 EG4 WP 48v 200A for the pump house today. Will update once it arrives and test runs a few days off grid. Thanks for your help.

  • @JR-xw5dk
    @JR-xw5dk 5 місяців тому

    Could you do a video on using welders with inverters. Is it ok to do and what extra capacity would you need if any? Thank you.

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      Thank you for your feedback! We will forward your suggestion to our marketing team!

  • @jeffvanhorn8933
    @jeffvanhorn8933 7 місяців тому

    Great explanation of the parallel setup for communications, but how does each inverter connect to the load panel? Would also like to see how the battery uses a bus bar to connect to each inverter.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому +1

      Hi @jeffvanhorn8933 They connect through each dedicated circuit breaker, sized according to manual.

    • @jeffvanhorn8933
      @jeffvanhorn8933 7 місяців тому

      Waiting for mine to come in, so maybe the manual will help it make sense to me. So if you had 10 inverters you would have 10 load panels? If that is the case what do the parallel wires accomplish? I know I'm missing something, which is why I think seeing the connections for each inverter would help it make sense to me. Thanks for the feedback. Loving the videos. @@SignatureSolar

  • @mrgruisinge
    @mrgruisinge 7 місяців тому +1

    Very good! Thank you. Very cleaar.

  • @bobcole3852
    @bobcole3852 5 місяців тому

    Nice, tell us this... if the breakers on the unit are 50 amps, why wouldn't you use a 50amp breaker and 6awg wire for line and load connections? I know 6awg wire will fitctheclugs on the breakers.
    Thanks, Kelley

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      We size breakers 1.2x larger to account for surges. We don't want a breaker opening the circuit and shutting off power just because a load has a small surge.

  • @stronghold0729
    @stronghold0729 7 місяців тому

    Can’t wait to get my hands on one of these!

    • @SignatureSolar
      @SignatureSolar  7 місяців тому +1

      It's a great unit! Let us know if you need any assistance along the way, we are happy to help!

  • @bhbaker220
    @bhbaker220 Місяць тому

    No mention of breaker size for the AC Output in the sub panel but I heard 40 amps in another video. No mention for breaker size in sub panel for AC Input.
    I’m confused by the following:
    5.8.1 GENERATOR SYSTEM CONNECTION When the generator is running, it will charge the batteries and excess AC power will be
    diverted to the AC output (LOAD) to power loads. The pass-through relay on the inverter’s generator
    terminal (GEN) is 30A. When the generator is on, please ensure the total load and charge current does
    not exceed 30A.
    5.10.1 OFF-GRID WIRING
    The 6000XP can accept up to 50 Amps (12kWs) of generator power and will pass
    through all available power to the loads. Therefore, the loads subpanel can be
    sized up to the size of the backup generator with 50 Amps minimum per inverter.

  • @InVinoVeritas.
    @InVinoVeritas. 5 місяців тому

    Can I insall right onto drywall or do you recommend using fireboard like other units?

    • @SignatureSolar
      @SignatureSolar  5 місяців тому +1

      We recommend using fireboard or cement board to mount onto, however, most drywall is also flame retardant!

  • @unemployedredneckhillbilly2023
    @unemployedredneckhillbilly2023 5 місяців тому

    Thanks for this. Going to add some solar backup in the spring to my channel and they look to be a good starting unit that is expandable and will start my 240 well pump.

    • @SignatureSolar
      @SignatureSolar  5 місяців тому +1

      Wonderful! Please don't hesitate to reach out with any questions or concerns!

    • @unemployedredneckhillbilly2023
      @unemployedredneckhillbilly2023 5 місяців тому

      @@SignatureSolar I just did. I went to order 2 and found out they are out of stock until the end of March. I will try again then along with batteries and panels.

    • @publicviewmedia4700
      @publicviewmedia4700 2 місяці тому

      🌈❤🧡💛💚💙💜@@unemployedredneckhillbilly2023 Redneck, I am an owner/operator of the 6000XP at my house. This unit is one of the hottest inverters in their inventory and has been on back order continually since Oct 23. I placed my order in Nov 23, and it was shipped out to me early Jan 24. Order now so you can get in line. I love this inverter - it is worth the wait.

  • @enricopallazzo3244
    @enricopallazzo3244 5 місяців тому

    Hello, do you guys work with local electricians/installers to help customers with set up? I would buy these today, but want to feel confident I have all my ducks in a row. Thanks!

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      Hi @enricopallazzo3244 We do not. We recommend looking here for licensed installers in your area! directories.nabcep.org/

  • @brianhowe7667
    @brianhowe7667 5 місяців тому

    Would one inverter be able to power a well pump, water heater, electric stove, one refrigerator and one freezer? Continuously at the same time?

    • @SignatureSolar
      @SignatureSolar  4 місяці тому +1

      Hi! The start up may be difficult! If you'd like to reach out to our tech team with your loads, we can get a better idea of what would work best for you!

  • @captindave71
    @captindave71 4 місяці тому

    Do you still need the 4pole 600v 20a DC isolator switch since the 6000xp already has the pv disconnect?

  • @zmarko
    @zmarko 7 місяців тому +6

    I just can't decide if I want to go off-grid, or hybrid and grid-tie.
    I'd like to have grid as a back-up and even sell excess back to the grid, but I keep reading horror stories about power companies screwing over customers in various ways.
    But if these can do off-grid and have grid as a back-up, without selling back, that would probably be my choice. There's just so much info out there and it's all changing so rapidly, it's tough to keep up.

    • @ssoffshore5111
      @ssoffshore5111 7 місяців тому +2

      @@Scotty2Balls I'm a little confused how this works not being able to sell back to the grid (off grid inverters), but still being able to pull from the grid as demand calls for it. How does it island while being tied, yet still work if the utility goes down? Likewise, when tied to a functional grid, how is solar, then battery, then line consumption prioritized? Can you explain further?

    • @ssoffshore5111
      @ssoffshore5111 7 місяців тому +1

      @@Scotty2Balls Thanks, I understand how hybrids work (I have a SA 15K). I'm just trying to grasp how you tie this inverter into a grid tied house, how it prioritizes solar first, and makes up the difference from the grid, and then also doesn't backfeed into the grid when the grid goes down. I'm sure I'm missing something, and maybe not understanding the 50A passthrough she mentioned.

    • @JCII100
      @JCII100 7 місяців тому

      Where’s the real benefit to sell back now?

    • @ssoffshore5111
      @ssoffshore5111 7 місяців тому

      @@JCII100 IMO, the only real benefit is if your utility still has a fairly lucrative net metering program. With that said, thanks to all the lobbying by the utilities (and of course the greedy folks who benefit from the payola), the lucrative NM programs are very quickly disappearing. If anyone still has access to such a program, they should absolutely sign a long-term contract while they can, because that option will almost certainly be gone soon! For those of us stuck with the newer NM programs which typically pay you back a few pennies for each kW sold back, it's not worth it!

    • @Josh-oe4ex
      @Josh-oe4ex 3 місяці тому

      So i'm interested in almost exactly the same thing. Something that uses PV power first and uses excess to charge batteries, then uses Batteries when sun gets low/cloudy, and finally uses grid power passthrough as needed. So that's "S, B, U" i think. Now i looked and looked and maybe people don't want to put it on youtube but i found a video showing the simplest wiring: Meter to disconnect to 18kpv(single or multiple units) and from the Load output straight into the top of your panel. No subpanels at all.
      It works fine apparently that unit and maybe even these 6000xps, have a 200A bypass automatically.
      I sure hope i'm not wrong cause with disconnects, a couple splitters to feed inverters and to couple their Load output? This would be simple and effective. No way is it code but i think if you do things right and know how to do math, know how to measure, triple check everythiing and leave a lot of overhead wiggle room for inrush current? It'd be fine.

  • @thomas-918
    @thomas-918 4 місяці тому

    When using this inverter offgrid with a grid backup, what happens when the grid goes down, what happens with the neutral ground bond? Would it automatically switch over to create a bond when the grid goes down?

    • @SignatureSolar
      @SignatureSolar  4 місяці тому

      No, it's not automatic on the XP but it's just one setting you change in the monitoring software.

  • @user-cd6yd4eg9s
    @user-cd6yd4eg9s 6 місяців тому

    Do you have a list of small Generators that would be compatible with connecting to a single EG4 6000XP Inverter? Do you have a generic wire diagram to help with proper connection?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      Hi
      @user-cd6yd4eg9s! -
      Generator sizing and requirements for this unit are in the manual starting on page 14! However, we do not provide wiring diagrams besides the one that is provided by the manufacturer in the manual.

  • @howardtempleton4197
    @howardtempleton4197 7 місяців тому +1

    what about the bypass fecher ? other than that good vid.

  • @kevinmerriweather3680
    @kevinmerriweather3680 5 місяців тому

    Can one run a shop with just lights, plugs, and power tools? And how many panels do I need and batteries?

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      Hi @kevinmerriweather3680 We would need to know details about the loads you are trying to run to be able to answer this question accurately. If you'd like to reach out to our sales department at 903-441-2090, they will be able to get you those answers!

  • @johnmcadaragh694
    @johnmcadaragh694 6 місяців тому

    If I have a portable 3000 watt 120v generator, can I use that to recharge the battery and set the inverter to pull a max wattage of 2500 watts from the generator?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому +1

      Hi @johncadaragh694 Unfortunately, you cannot use this with a 6000XP. The 6000XP requires split-phase input with 2 hot legs.

  • @dupre7416
    @dupre7416 2 місяці тому

    I think this 6000XP is perfect for my off-grid cabin. Do you expect any big updates to this model within the next 18 months? Perhaps a better screen?

    • @SignatureSolar
      @SignatureSolar  2 місяці тому +1

      We have not been given any update by the manufacturer to date

  • @snake10566
    @snake10566 6 місяців тому

    Does this unit bypass from grid to load in the case of a total failure of equipment?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому +1

      There's a manual bypass switch that connects the
      loads to LOAD panel as default. If the inverters fail, users can switch the loads to utility, manually.

  • @VinceBadovinatz88
    @VinceBadovinatz88 6 місяців тому

    I'm trying to find how much solar input I need to make the mppt fire up 450 watt panels I think they're about 41 volts

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      Hi
      @VinceBadovinatz88 ! Thank you so much for your question! If you would like to reach out to our tech support team at 903-441-2090 or via email at tech@signaturesolar.com, they will be able to answer all of your questions! If you need any further assistance, feel free to contact me directly at engagement@signaturesolar.com!

  • @BullittAutomotive
    @BullittAutomotive Місяць тому +1

    If i have 220v appliances and 120v appliances at the same time do i have to use separate inverters or can i use 1 inverter? (Example: a/c unit and refrigerator)

  • @paulbuoniconti5275
    @paulbuoniconti5275 4 місяці тому

    Did I miss the part where we hook up grid power in and not generator or is that the same settings?

    • @SignatureSolar
      @SignatureSolar  4 місяці тому +1

      We typically leave the AC side of things to a licensed electrician for safety.

  • @bigredwag
    @bigredwag 7 місяців тому

    Does it function fully if not connected to the internet? So if your servers ever disappear, these devices are still functional?

    • @SignatureSolar
      @SignatureSolar  7 місяців тому +1

      It will function without the internet, you would need wifi for remote monitoring however.

  • @AngelaHutchison-ky8gh
    @AngelaHutchison-ky8gh 15 днів тому

    I have 4000 total watts from panels. With this inverter would you run all in one string or split to utilize both mppt’s? Voltage is fine either way. Looking for most efficient use of power. Thanks!

    • @SignatureSolar
      @SignatureSolar  11 днів тому +1

      If the voltage exceeds 385VDC for that string, we suggest splitting it into 2 strings as a single MPPT's 'sweet spot' is 385VDC

  • @HK-hy9od
    @HK-hy9od 3 місяці тому

    I‘m a beginner of solar research. Seeing EG4 is pretty attractive. What is the difference between solar system from other solar company and EG4 package? Does it mean I have to find a electricity contractor to install EG4 and get technician to mount the solar panel on my lawn? Can you tell how much does the system charge for usage of 18,000Watts please?

    • @SignatureSolar
      @SignatureSolar  3 місяці тому

      Hi! We sell DIY equipment but we always recommend having a licensed electrician assist in installation!

  • @TH-zv5le
    @TH-zv5le 3 місяці тому

    I need around 18kW of power for our house. Is it possible to parallel an EG4 6000XP with an EG4 18kW Hybrid??? Both inverter would have EG4 PowerPro batteries connected to them.

    • @SignatureSolar
      @SignatureSolar  3 місяці тому

      No, but you can AC couple it to the 18kPV

  • @alansanders7231
    @alansanders7231 7 місяців тому +1

    Can anyone give a solid answer on batteries to be used with this system? I already have a 48 volt 400 Ah LiFePO4 battery bank made up of a Power Queen series parallel configuration. No communication. Can this unit be configured to safely charge and use this battery bank? On the EG4 systems, I keep hearing answers like "this should work". I need to know yes or no, and if yes what battery settings would be used.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      Here's the battery compatibility list: eg4electronics.com/backend/wp-content/uploads/2023/10/EG4-6000XP-Battery-Compatibility-List.pdf. If your unit is not communicating with your batteries you could set to 'led acid' battery type, set the total Ah of the bank. And make sure the charging V/A settings are in accordance with the battery specs. Our tech team can walk you through how to do this properly, give them a call at 903-441-2090.

    • @alansanders7231
      @alansanders7231 7 місяців тому

      @@SignatureSolar Can your lead acid settings be adjusted to constant current, and constant voltage settings required to charge an LiFePO4 battery technology without damaging the battery?
      48V LiFePO4 Battery Charging Parameters
      Charging voltage: 56.8-58.4V
      Float voltage: 54.4V (or disabled)
      Maximum voltage: 58.4V
      Minimum voltage: 40V
      Nominal voltage: 48V or 51.2V

  • @woolval52
    @woolval52 5 місяців тому

    At 9:08 you say torque battery bolts to 36~45 in-lbs. On page 15 of my manual it says 97~106 in-lbs. Which is correct? Thanks. I’m connecting everything today. Yippee!

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      Thank you so much for bringing this to our attention! We will look into this. If you'd like to reach out to me at engagement@signaturesolar.com, we can update you on the outcome!

    • @SignatureSolar
      @SignatureSolar  5 місяців тому

      Update: The 6000XP manual on the EG4 or S2 sites are the most updated versions.

    • @woolval52
      @woolval52 5 місяців тому

      OK… so the looking at the manual on line, it says 97~106 in-lbs. which is what I did.

  • @ssoffshore5111
    @ssoffshore5111 7 місяців тому +1

    I'm a little confused how this works not being able to sell back to the grid (off grid inverters), but still being able to pull from the grid as demand calls for it. How does it island while being tied, yet still work if the utility goes down? Likewise, when tied to a functional grid, how is solar, then battery, then line consumption prioritized? Maybe I'm just confused about how the 50A "passthrough" works! Can you explain further?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому +2

      The 6000XP can use energy from PV, Grid, or batteries for powering the output. However, not all the sources are required. In an off-grid situation, the inverter can be used with just batteries and solar as the energy source.
      The 6000XP can also be used with just battery and grid. This is useful for power backup or load shifting without the expense of the PV modules. In other configurations, the inverter can operate with no batteries and just use PV and Grid. In this configuration the inverter will power from the PV as long as the PV is providing adequate power. If the PV power fall below the demand of the load, the unit will switch to powering completely from the Grid.

    • @ssoffshore5111
      @ssoffshore5111 6 місяців тому

      @@SignatureSolar TY!

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      You're welcome!

  • @girltechsteader
    @girltechsteader 2 місяці тому

    If I am paralleling three of these inverters, page 20 of the manual says I need a generator greater than 20kw with less than 3% THD. Can you recommend a propane generator that fits those parameters?

    • @SignatureSolar
      @SignatureSolar  2 місяці тому +1

      We can only recommend the parameters, not the brand.

    • @SignatureSolar
      @SignatureSolar  2 місяці тому +1

      If you’re not looking to power loads with your generator, the chargeverter is an option!

    • @girltechsteader
      @girltechsteader Місяць тому

      @@SignatureSolar Thank you for replying. The only other question I have is: Is the EG4 6000 XP a Pure Sine Wave inverter?

  • @A.C.71
    @A.C.71 7 місяців тому

    I never heard back from the design team on my question so ill try here. I have already installed a reliance pro/ trans 2 model 306c manual transfer switch, I used to have a ecoflow delta pro and simply plugged the rv style L14-30 generator cord from the delta pro to the transfer switch male L14-30 plug and everything worked flawlessly. So can I simply get a female L14-30 plug then wire it with the 4 wires from the 6000xp then simply plug in my generator cord from that to my protrans2 transfer switch's L14-30 and be good to go?

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      We are so sorry you haven't been able to reach the design team. If you'd like to reach out to me at engagement@signaturesolar.com I can get you connected with them!

    • @A.C.71
      @A.C.71 7 місяців тому

      @@SignatureSolar Thanks You. I'm getting ready to buy 1 6000xp and three battery's, I just need to know how do I hook them up to my protrans2. I'll reach out to that email now. thanks again.

    • @bhbaker220
      @bhbaker220 Місяць тому

      Did you get an answer from Signature Solar? I’ve got the same question. In my situation, I don’t think I’ll go over 30 amps on the L14-30 receptacle. But if I did have surges above 30 amps, it’s probably better to hard wire the 8 gauge to the 10 gauge wires inside the transfer switch

  • @garrickgaffigan4522
    @garrickgaffigan4522 7 місяців тому

    Will it output 3000 to one 120v leg and 3000 to the othet simultaneously? Ive got no need for 240 currently.

    • @ssoffshore5111
      @ssoffshore5111 7 місяців тому

      Yes

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      It is capable of that. It is not capable of Line balancing so you would want to make sure that the L1 and L2 are as balanced as possible in the output panel box and that it doesn't exceed 3000W per leg.

  • @markrund6292
    @markrund6292 4 місяці тому

    My understanding is that a hybrid like the EG4® 18kPV-12LV would allow me to power my Rv with solar and battery, sipping off the grid to make up any deficit. Does this Inverter have that ability as well ?

    • @SignatureSolar
      @SignatureSolar  4 місяці тому

      Not while solar or battery are prioritized. The 18kPV is capable because it is a hybrid unit, but this in an off-grid inverter, which means battery and solar will be prioritized and utility will only kick in when those 2 sources are not present.

    • @markrund6292
      @markrund6292 4 місяці тому

      @@SignatureSolar Thank you for your response. I guess I’m spending 3 or 4 times the money for a hybrid. Eh.

  • @jdell6250
    @jdell6250 7 місяців тому

    50amp double pole breaker for grid assist/connect?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      Yes it is 50A double pole breaker for Grid connect

  • @Homesteadexodus777
    @Homesteadexodus777 3 місяці тому

    Yall should definitely do a more detailed video of ( off grid only) installation

    • @SignatureSolar
      @SignatureSolar  3 місяці тому

      Thanks for the idea! We will pass that along to our Marketing department!

  • @matthewknight5641
    @matthewknight5641 4 місяці тому

    Is there any way i can use this with my batteries ive built from 280k cells and jk bms's ? Ive built close to 45 kw of batteries and couldn't afford to start over with different batteries

    • @SignatureSolar
      @SignatureSolar  4 місяці тому

      You can see if it's BMS compatible here: eg4electronics.com/backend/wp-content/uploads/2023/10/EG4-6000XP-Battery-Compatibility-List.pdf

  • @AdorableDeplorable1
    @AdorableDeplorable1 6 місяців тому

    When using LifePower batteries, is the firmware update needed for the 6000xp or the batteries?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      Yes to be able to BMS communicate you will need to do a firmware update. You can use a LAN cable from the battery to the inverter to do the update. If you run into any issues along to way give our tech department a call at 903-441-2090.

    • @AdorableDeplorable1
      @AdorableDeplorable1 6 місяців тому

      @@SignatureSolar Thanks for the response. Is there a document or video somewhere that includes the steps for the firmware update, or does it happen automatically?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      There is a PDF guide in the firmware folder when you download it.

  • @theMekanik
    @theMekanik 7 місяців тому

    Please Series Konnekt 10 of your 48 volt batteries and plug it into the MPPT.

  • @adrenalinejunky789
    @adrenalinejunky789 7 місяців тому

    Do the lights flicker when a load kicks on?

    • @publicviewmedia4700
      @publicviewmedia4700 2 місяці тому

      🌈❤🧡💛💚💙💜 Adrenaline, I am an owner/operator of this 6000XP inverter off-grid and there is NO FLICKER at all. I have not had to use a generator, but it is possible there could be flicker if you activate a generator.

  • @user-xb2lj5md5x
    @user-xb2lj5md5x 2 місяці тому

    Can you install this 6000xp split phase inverter with (2) eg4 powerpro 48v batteries in parallel?

  • @tonywilliams4336
    @tonywilliams4336 7 місяців тому

    What is the minimum solar array that can be used with this unit. I would like to use it for my welding hobby, which i don't do but one or twice a week if that often. in fact I have not used my wedding equipment in four months. (time weather, life and emergencies)

    • @tjmooney4181
      @tjmooney4181 7 місяців тому +1

      Check the voltage of the panels you want to use and see how many are needed in series to reach 120v minimum required for 1 of these to work

    • @TRYtoHELPyou
      @TRYtoHELPyou 7 місяців тому +2

      140v was mentioned in the video as minimum needed to start it all up...

    • @tonywilliams4336
      @tonywilliams4336 7 місяців тому +1

      @@TRYtoHELPyou I am at work at TV MC. I miss somethings on first go around. Noone like black screen or wrong thing on the air.. TNX, 73

    • @joetripp123
      @joetripp123 7 місяців тому +2

      The manual states a minimum of 140v for startup and to stay below 480v. I would use 200v minimum just so it starts up on less than ideal days. Manual also states the most efficient solar string for the unit is 320v and 17a.

  • @boblupart862
    @boblupart862 7 місяців тому +1

    So I am really not sure if I am unhappy now or not. The 6000XP takes all the problems for my potential setup away. With those problems gone I have no excuse to not work on my plan. Now I have to figure out where to get the 11k dollars for the batteries and several 6000XPs........ For now I will just give an aggressively passive Thanks.

    • @lioneldisla01
      @lioneldisla01 7 місяців тому

      Right.. here i was with my extensively thought out wiring diagram with fuses, breakers and isolators everywhere.. all gone now.. can u lend me 3k?

  • @jordanwitherow6324
    @jordanwitherow6324 5 місяців тому

    What size of breaker and what wire size is coming from each 6000xp to the load panel? Thanks I think it’s a 60amp breaker with 6 awg wire but just asking to make sure

  • @uk.easunpower
    @uk.easunpower 6 місяців тому

    nice video

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      Thanks! We are happy you enjoyed it!

  • @robertwylie5567
    @robertwylie5567 6 місяців тому

    Is it critical that this is mounted upright? Can it not be mounted horizontally on its back?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      Yes, according to the manual this unit should be installed upright on a vertical surface.

  • @benbillybobjoe
    @benbillybobjoe 2 місяці тому +1

    My dad wants to use this outside (in his barn), in WA state, but he's worried because the temperature gets down to -12°F and up to 117°F
    What can he do to keep it from turning off on him?

    • @SignatureSolar
      @SignatureSolar  2 місяці тому +1

      Hi! A suggestion would be to install a mini-split to control the temperature in the barn.

    • @benbillybobjoe
      @benbillybobjoe 2 місяці тому

      @@SignatureSolar so, the temp rating restricts the use to temp controlled environments, got it

  • @mainerusnr
    @mainerusnr 6 місяців тому +1

    I'm CONFUSED! I have watched this video twice and watched Will Prowse's videos on this inverter a couple times too. One of the selling points for this unit was that a separate solar panel disconnect switch wasn't needed because there is one on the side of the unit. Yet at 2:42 it mentions having a "PV disconnect switch" and at 7:21 she says to add a "PV isolation switch" aren't these two switched one and the same thing?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому +3

      The reason it is recommended is because it is not an outdoor rated unit, and some municipalities require an external PV disconnect.

    • @mainerusnr
      @mainerusnr 6 місяців тому

      Thank you! @@SignatureSolar

  • @joshclark121987
    @joshclark121987 Місяць тому

    Is there a device for a generator to lower the harmonic distortion under 3% to use with the inverter?

    • @SignatureSolar
      @SignatureSolar  Місяць тому

      If your goal is solely to charge your batteries using the generator and not to power other loads, you might consider using a Chargeverter. This device helps clean up the generator's power. However, we currently don't have recommendations for a unit that can clean up the generator's power for other loads.

    • @joshclark121987
      @joshclark121987 Місяць тому

      @@SignatureSolar it would be a backup at night to charge batteries and power my 4kw of crypto miners till the sun comes out.

  • @jameskhoo8407
    @jameskhoo8407 6 місяців тому

    Can someone tell me the conduit box used in this video?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      This is a wire trough! You can get them at places like Grainger Industrial.

  • @Cody_Ramer
    @Cody_Ramer 2 місяці тому

    So is it 240 volts 17 amp max for each pv connection then? Or is it able to have 480 volts 17 amps max on each one?

    • @SignatureSolar
      @SignatureSolar  2 місяці тому

      480/17 to each

    • @Cody_Ramer
      @Cody_Ramer 2 місяці тому

      @@SignatureSolar so each are able to handle 8000 watts despite only being able to utilize 4000, good to know thanks for replying.

    • @SignatureSolar
      @SignatureSolar  2 місяці тому

      You're so welcome!

  • @lkevonly
    @lkevonly 7 місяців тому

    What size is the battery cable to inverter?

  • @booterone1
    @booterone1 7 місяців тому

    Are these inverters capable of AC coupling?

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      This unit does not have the ability for AC coupling. Let us know if you have any other questions, we are happy to help!

  • @wyldeman
    @wyldeman 23 дні тому

    I wonder if it would run a one bedroom house with hvac water well water heater?

    • @SignatureSolar
      @SignatureSolar  23 дні тому

      Hi! No it won’t, you would need a few of them to do that.

    • @wyldeman
      @wyldeman 23 дні тому

      @@SignatureSolar what about the 18 eg4

    • @SignatureSolar
      @SignatureSolar  20 днів тому

      It could depending on the size of everything

  • @pusico6555
    @pusico6555 7 місяців тому

    Can you use 3 units to create 3 phase?

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      3 phase is not possible with the 6000XP.

  • @YaNv3
    @YaNv3 6 місяців тому

    Please help with the shipping dimensions

  • @lightdepsolutionssolutions4099
    @lightdepsolutionssolutions4099 7 місяців тому

    Mine still doesn’t work in lithium ion mode. Only led acid. Called tech support several times… they’re telling me cells are imbalanced with my brand new Eg4 wall mount and keep charging and discharging. I dunno…

    • @SignatureSolar
      @SignatureSolar  7 місяців тому +1

      Hi @lightdepsolutions4099! I spoke with Tech support and they have informed me the problem has been resolved! Please don't hesitate to reach back out with any other questions or concerns!
      [To correct the issue, we just had to change the model selected!]

    • @lightdepsolutionssolutions4099
      @lightdepsolutionssolutions4099 7 місяців тому +1

      @@SignatureSolar they helped me out and we got it resolved! Thanks guys!

  • @ronbown3836
    @ronbown3836 25 днів тому

    Do you have a video that has ongrid installation?

    • @SignatureSolar
      @SignatureSolar  24 дні тому

      There is not a separate video, you will just connect the grid to the unit.

    • @ronbown3836
      @ronbown3836 24 дні тому

      @@SignatureSolar ok.

    • @ronbown3836
      @ronbown3836 24 дні тому

      @@SignatureSolar so in the fuse panel or breaker panel you would have two breakers one for off-grid and one for on grid. When you want to run off grid you turn the on-grid breaker off and the off-grid breaker on is that right? Another question when you have the on grid breaker on will that still charge the batteries off the solar array?

  • @stuartbrock7586
    @stuartbrock7586 12 днів тому

    Why is a PV isolater switch needed when there is one built into the unit?

    • @SignatureSolar
      @SignatureSolar  11 днів тому

      One isolator switch on the unit allows you to shut off the PV directly. The other isolator switch is intended for firefighters and is located in an easily accessible area.

    • @stuartbrock7586
      @stuartbrock7586 11 днів тому

      @@SignatureSolar I see, so it needs to be outside mounted with the panels on a ground mount system

  • @Lukeor
    @Lukeor 7 місяців тому

    Can this be grid tied? Hybrid?l and export? 1.2kwh daily? Huh?

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      The 6000XP can use energy from PV, Grid, or batteries for powering the output. However, not all the sources are required. In an off-grid situation, the inverter can be used with just batteries and solar as the energy source.
      The 6000XP can also be used with just battery and grid. This is useful for power backup or load shifting without the expense of the PV modules. In other configurations, the inverter can operate with no batteries and just use PV and Grid. In this configuration the inverter will power from the PV as long as the PV is providing adequate power. If the PV power fall below the demand of the load, the unit will switch to powering completely from the Grid. You are not able to sell energy back to the grid with this inverter however.

  • @redrollback
    @redrollback 3 місяці тому

    I used 1000 kw a month will this take place of the grid

    • @publicviewmedia4700
      @publicviewmedia4700 2 місяці тому

      🌈❤🧡💛💚💙💜 I have a 6000XP off grid to power my small house. I have had peak days where this inverter has pulled in 3500kw in a day while I consumed 2800kw on the same day. I think it will handle your 1000kw needs without breaking a sweat.

  • @TheFatman819
    @TheFatman819 7 місяців тому

    At 1:39 min you state PV total of 10,000 watts then say that is spread out over the two MPPTs at 4,000 each.

    • @erikj9962
      @erikj9962 7 місяців тому

      I think you can over panel to 5,000 watts per input. The MPPT clips the input to 4 kW when you have full sun.

  • @nitinjirawal
    @nitinjirawal 7 місяців тому +1

    Is it a transformer less inverter?

  • @deeprootslandscaping4499
    @deeprootslandscaping4499 6 місяців тому

    Is this unit certified in ontario Canada
    I guess not lol

  • @jackmontgomery3131
    @jackmontgomery3131 5 місяців тому

    When i try to register my dongle it says that SN# has already been used

    • @SignatureSolar
      @SignatureSolar  5 місяців тому +1

      If you'd like to reach out to me at engagement@signaturesolar.com I can get you connected with the appropriate department and get you taken care of!

  • @theMekanik
    @theMekanik 7 місяців тому

    Kewl, I want one please send thank one with the 280AH battery thanx!

    • @SignatureSolar
      @SignatureSolar  6 місяців тому

      Here is the link! signaturesolar.com/eg4-6000xp-off-grid-inverter-split-phase/

  • @christsitouridis2213
    @christsitouridis2213 4 місяці тому

    Is it available in Europe?

  • @jkohutiak
    @jkohutiak 2 місяці тому

    Of course my 6000xp is a pain in the rearend! None of your support is able to respond with useful info, unable to tell me what is wrong or how to fix it. My electrician does not understand the connections on this unit. Mine is entirely unable to do anything! Thanks guys!

    • @SignatureSolar
      @SignatureSolar  2 місяці тому

      Hi! If you’d like to reach out to us directly at engagement@signaturesolar.com we can escalate your issue and get you taken care of!

    • @publicviewmedia4700
      @publicviewmedia4700 2 місяці тому

      🌈❤🧡💛💚💙💜 Not sure who you have as an electrician, but I am a DIY novice and I just followed the instructions and called Signature Solar technical support when I had a question. jko, ever since I turned it on in January this year, my 6000XP has worked amazingly to heat, cool and supply all the power I've needed in my home - and I am completely off-grid.

    • @paulbaker3144
      @paulbaker3144 3 дні тому

      Get a different electrician for starters to make sure it’s all connected correctly. The programming is the next challenge after that.

  • @Capoe3
    @Capoe3 7 місяців тому +12

    Wish the 6500 ex hadnt Ben sunsetted so fast.

    • @RISCGames
      @RISCGames 6 місяців тому +5

      I think the biggest thing with this is the fact it has the breaker builtin and it’s far more efficient at 50w idle over the 130w of the old one

    • @punkrawqer
      @punkrawqer 6 місяців тому +2

      Glad it did, it was garbage. Shorted out on me in one month and idle consumption was stupid high.

    • @Homesteadexodus777
      @Homesteadexodus777 3 місяці тому

      ​@punkrawqer yes, the idle consumption sucks especially if your not on grid

    • @drunk_astronomy
      @drunk_astronomy Місяць тому

      Why???

    • @Capoe3
      @Capoe3 Місяць тому

      @@drunk_astronomy Because I wanted updates to the firmware. Have two of them.

  • @rickm5853
    @rickm5853 5 місяців тому

    Outdoor version?

    • @SignatureSolar
      @SignatureSolar  5 місяців тому +1

      At the moment, we don't offer an outdoor version of the 6000XP. However, we're always exploring new possibilities and innovations. Please check back with us in the future for any updates or potential outdoor options. The 18Kpv is outdoor rated, however it does have to be covered.

  • @tjmooney4181
    @tjmooney4181 7 місяців тому +3

    Much rather have 2 of these than the 18kpv

    • @dswaggins2464
      @dswaggins2464 7 місяців тому

      Half the price.

    • @SignatureSolar
      @SignatureSolar  6 місяців тому +1

      Doing this gives you redundancy and much more flexibility!

    • @tjmooney4181
      @tjmooney4181 6 місяців тому

      @SignatureSolar I'm completely off grid, 2 of these 6000xp paired with 2 powerpro batteries has been perfect for me 3 months now

  • @flopackrc5452
    @flopackrc5452 7 місяців тому

    480voc per mppt ?
    2 series strings of 400v each input ?

    • @qazssxedc
      @qazssxedc 7 місяців тому +1

      Each MPPT input can handle 17A 480VDC

    • @briha3142
      @briha3142 7 місяців тому +2

      She said (@ 1:48) 480 VOC across the two MPPTs! That’s NOT 480VOC per MPPT! This is quite confusing because the Solar Forum people are saying it’s 480 VOC per MPPT! I wish we could get the correct VOC in writing somewhere, but the manual is not clear on that, at all! Signature Solar, please clarify to ALL who purchase this unit! I have two coming! (sigh)

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      @@briha3142 The video is correct, it's 480 across the two MPPTS. Let us know if you have any questions!

    • @marktomlinson3448
      @marktomlinson3448 7 місяців тому +1

      @@SignatureSolar The confusion is due to the use of the word "across". Please explain it without using that word. I think it is really 480 VOC max to EACH MPPT.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      @@marktomlinson3448 it's 480 for both MPPTS, not each. Let us know if you have any additional questions.

  • @jmsund
    @jmsund 7 місяців тому

    The operational temperature minimum on the data sheet is 32F. Don't plan on installing this in a power shed or unheated garage.

    • @SignatureSolar
      @SignatureSolar  7 місяців тому

      Correct! The operational temperature range is 32 - 113°F for this unit to prevent potential damage or malfunctions. In areas where the temp gets lower a heater would be ideal.

  • @terrybrown5883
    @terrybrown5883 5 місяців тому +1

    Question

    • @terrybrown5883
      @terrybrown5883 5 місяців тому +1

      I am Building a new Cargo work trailer
      It will have 10 San Tan 250W panels
      The Air Conditioner from Seville 9000 BTU mini split Air Conditioner with Heat Pump sent/09ch/220v
      The Battery 4 X 24v 200 amp
      There is a Generator on the Truck as Backup

    • @terrybrown5883
      @terrybrown5883 5 місяців тому +1

      With this Unit can I use the Generator or Power at the Shop to Charge on Days it’s bad Weather and Bad Sun

    • @SignatureSolar
      @SignatureSolar  5 місяців тому +1

      Yes, the manual lists the generator specifications that EG4 recommends. You can use AC to charge batteries when you don't have sun.

    • @terrybrown5883
      @terrybrown5883 5 місяців тому +1

      Thank you so much for your help

    • @SignatureSolar
      @SignatureSolar  5 місяців тому +1

      You're so welcome!

  • @jackmehoffer7819
    @jackmehoffer7819 2 місяці тому

    It’s to bad signature solar is horrible to work with. Tried to return a un-opened growatt 3000 that was sold to me by signature solar after talking to a sells person. Well he failed to tell me that the 3000 growatt needed 140v just to start and required 1200 watts of solar. I did not have the real estate on my 28 ft trailer for 1200 watts of solar and tried to return it and they refused. Even knowing the box was never opened.

    • @SignatureSolar
      @SignatureSolar  2 місяці тому

      Hi @jackmehoffer7819 - We're so sorry you've had trouble with our support. If you'd like to reach out to us directly at engagement@signaturesolar.com, we'd like to see what we can do to get you taken care of!

  • @richardthames661
    @richardthames661 4 місяці тому

    And what happens when the rest of the power grid falls and there is no Wi-Fi then your machine is obsolete

    • @SignatureSolar
      @SignatureSolar  4 місяці тому

      Hi @richardthames661 If the grid goes out the inverter will still work. If losing connection to Wi-Fi is a concern, it only gives the ability to monitor and you can use the LCD screen to do this and change settings.

    • @publicviewmedia4700
      @publicviewmedia4700 2 місяці тому

      🌈❤🧡💛💚💙💜 Richard, I am an owner/end-user of the 6000XP. The WIFI is only to accommodate the app on your phone which is a completely ancillary interface and separate from the operation of the inverter itself. If the power goes out, you won't even notice.

  • @tjmooney4181
    @tjmooney4181 7 місяців тому +2

    Thanks 👍 buy bitcoin