Bad High Pressure Switch

Поділитися
Вставка
  • Опубліковано 4 лип 2023

КОМЕНТАРІ • 25

  • @WhowereEpsteinsclients
    @WhowereEpsteinsclients 11 місяців тому +11

    Jumper wire left the chat.

  • @TWOWHEELSONELIFELEFT
    @TWOWHEELSONELIFELEFT 11 місяців тому +16

    Where is your gauges. You don’t just assume The switch is bad.

    • @maxsilva5454
      @maxsilva5454 10 місяців тому

      Absolutley
      Got sent to a job where diff condomed high pressure cut out switches bc unit wasnt comingnon
      system was flat ......

    • @Kilcrops0914
      @Kilcrops0914 9 місяців тому +2

      ​@@maxsilva5454how was the high pressure switch cutting unit off if system was flat?

    • @P9rkour90
      @P9rkour90 4 місяці тому

      Always use your gauges!! But I’m assuming he did already since well, he’s an HVAC technician lol but ya never know….

  • @ramellin
    @ramellin 10 місяців тому +1

    Good call 👍

  • @craigkennedy9968
    @craigkennedy9968 11 місяців тому +4

    no gauges ? and you determine that an overcharged unit has a bad HPS ?

  • @darrend2035
    @darrend2035 11 місяців тому +2

    We’ve been seeing the Newer YORK residential heat pumps (2 or 3 years old)
    with a shit load of faulty pressure switches
    And yes you have to braze it in 😐

    • @Davidandgoliathhvac
      @Davidandgoliathhvac  11 місяців тому

      Thanks for sharing I’ll keep that in mind with the newer Yorks!

  • @kennybakerhvacr5751
    @kennybakerhvacr5751 Рік тому +13

    If you have voltage going in but not coming out before the HPS are you sure the high pressure switch is bad and not just doing what its supposed to be doing?

    • @Davidandgoliathhvac
      @Davidandgoliathhvac  Рік тому +6

      High pressure switches are normally closed and when they do open they should close back once the pressure drops below the rating for that pressure switch. This pressure switch got stuck in the open position thus not letting low voltage go through it to the contactor.

    • @kennybakerhvacr5751
      @kennybakerhvacr5751 Рік тому +8

      @ramseyhvac I understand how it works. The point I was making is simply that just because voltage is coming in but not leaving the outgoing side of the board is rarely a case of a failed pressure switch. More often than not its something working correctly and protecting something, such as the compressor. Thank you for your quick response. I'm not here to troll. I'm like you. I see a problem and immediately think of the things it could be is all.

    • @Davidandgoliathhvac
      @Davidandgoliathhvac  Рік тому +7

      @@kennybakerhvacr5751 I hear what you’re saying. And after I replaced the pressure switch, I checked amps on the compressor, fan motor, pressures, SC, SH, Delta T. I also checked the outdoor coils and they where not that dirty. Thanks for the question. We are all trying to learn.

    • @Weird_1
      @Weird_1 11 місяців тому +3

      ​@@Davidandgoliathhvacthat is the way to check. Also sometimes you can tap on them to free up the switch temporarily until you get a new one

  • @omarantonetti8417
    @omarantonetti8417 10 місяців тому +1

    You'd be surprised how many people don't know you can by pass until you return for repair
    Same with defrost boards 😂😂😂

    • @7573Dca
      @7573Dca 7 місяців тому

      Definitely dont bypass a lps that could end very badly

  • @bottitabaki3073
    @bottitabaki3073 9 місяців тому

    Hi. Did you make video for this repair?

  • @user-be4tu1pq8j
    @user-be4tu1pq8j 11 місяців тому

    Check Continuity

  • @vitor7954
    @vitor7954 11 місяців тому +3

    High pressure is working its the run cap or condenser fan motor what tripped it there is a reason where are your gauges

  • @Kilcrops0914
    @Kilcrops0914 9 місяців тому

    Turn unit on and condender fan motor is bad 😂

  • @jrsmyth9761
    @jrsmyth9761 11 місяців тому

    YES, it is so obvious the pressure switch is bad!!!!
    It couldn't be that the pressure switch, a safety device, is doing its job.
    Can you say, "I am a hack"?

  • @hvacforanyone8594
    @hvacforanyone8594 10 місяців тому

    Really-🤔-Interested

  • @RobertAziz26
    @RobertAziz26 11 місяців тому

    Is the switch open or close 🤔

    • @user-be4tu1pq8j
      @user-be4tu1pq8j 11 місяців тому

      Open power on not completing circuit obv