How to calculate the over-lapping length of steel bars in slab,column and beam in Urdu/Hindi

Поділитися
Вставка
  • Опубліковано 4 жов 2024
  • Official Website www.civilclick.... Friends Minimum overlapping is 175 mm my mistake.....i apologize this.... i notice this after the video so sorry about that........
    in this video i am going to show you the different formulas we use in our field side in slab and in beam,column for over-lapping steel bars....in this we have two zone in beam 1 is compression zone and 1 is tensile zone....in both of the zone we use different formula.....so good luck......
    share this video to your friend......
    To keep in contact follow me......
    Website :- www.civilclick....
    Facebook :_ / civilforeyou
    Instagram :- / moid_11
    Google+ :-plus.google.co...
    =====================================================
    ==how to calculate the quantity of cement sand and aggregate in concrete video...
    • How to calculate the q...
    ==different grades of concrete we use for different work video...
    • Different grades of co...
    ======================================================
    Subscribe the channel click the RED button
    =====================================================

КОМЕНТАРІ • 210

  • @FORYOU1
    @FORYOU1  7 років тому +41

    Sorry Friends Minimum over-lapping is 175 mm not 75 mm .....

    • @theLastone811
      @theLastone811 7 років тому +6

      FORYOU thx brother i apprished your work and you
      say i am wrong
      and say sorry its good work

    • @mohammedshanavajpajanigar8523
      @mohammedshanavajpajanigar8523 6 років тому +2

      You have to delete those videos which you made the mistakes

    • @abhishekgupta344
      @abhishekgupta344 6 років тому

      Mujhe yhe jna hai ki Ld wale formula s app lapping kr rhe hai usk bd fir app kych aur bta rhe hai mai exactly doubt mai hu ki development lenght aur lapping mai kya difrrence hai

    • @shrikantdeshmukh6337
      @shrikantdeshmukh6337 6 років тому

      Thik Hogya...

    • @abhilashgautam5476
      @abhilashgautam5476 6 років тому

      F&U-FORYOU ty sir👍

  • @md.saifullahansari6920
    @md.saifullahansari6920 4 роки тому

    Sir aapka samjhane ka style bhaut achha hai

  • @mr.amitdance9058
    @mr.amitdance9058 3 роки тому

    Thanks sir aapne bahut achhi jankari diye

  • @zohaibahsan471
    @zohaibahsan471 6 років тому

    sir,ap ki videos bohat achi hain. ap bohat acha kam kr rhy hain.hammy boht achi info mil rhi ha. thnks a lot

  • @imadali1233
    @imadali1233 7 років тому +3

    Amazing video..keep it please your video to much helpfull for civil frsh engineers and Diploma holders

    • @malikarfan8759
      @malikarfan8759 7 років тому

      Thanks for sharing good video.. one thing i want to say that if you explain with site picture with rebar its more clear for us,,,, and boss you explain only beam where we have compression and tension can you explain for column, footing, and raft that which piont are compression and tension. Its very usefull for us.

    • @mirmohdmaqbool132
      @mirmohdmaqbool132 6 років тому

      Nice sir

  • @muhammadmoin4755
    @muhammadmoin4755 7 років тому +1

    great Sir . Mashaa Allah

  • @civilvibes8036
    @civilvibes8036 4 роки тому

    Nice sharing

  • @mohey-u-dinkhanlodhi5719
    @mohey-u-dinkhanlodhi5719 5 років тому

    bro good job really

  • @kamrankhan-qx6ks
    @kamrankhan-qx6ks 4 роки тому

    a o a sir it is help full

  • @zakichoudhry4524
    @zakichoudhry4524 6 років тому

    You are Great sir

  • @wonderingcivil8808
    @wonderingcivil8808 7 років тому +1

    thank u sir.nice tips for us.GOD bless u

  • @mashkoor2277
    @mashkoor2277 5 років тому

    Very informative

  • @ambrishsharma813
    @ambrishsharma813 4 роки тому

    Nice informative video. Kindly mention the place where overlapping is to be given. A.k.sharma

  • @pmishraJSR
    @pmishraJSR 5 років тому

    क्या यह हर तरह के व्यास के लिये फार्मूला प्रयोग कर सकतें है..या कहें कि 25 mm steel bars से ज्यादा के व्यास में प्रयोग करना उचित होगा

  • @sadekpathan7085
    @sadekpathan7085 7 років тому

    very use fully video

  • @muhammadilyas4650
    @muhammadilyas4650 6 років тому

    Nice sir jazakallah

  • @mohammadtaqui1371
    @mohammadtaqui1371 7 років тому +3

    fantastic content

  • @raiyanahmad8653
    @raiyanahmad8653 6 років тому

    Plz.. Give my ans... Today in the morning I asked my senior about that problem.. he solve it.. I think 1st u confirm then make a video ..

  • @danishrahman2737
    @danishrahman2737 4 роки тому

    Thank you sir g

  • @Arunkumar-fn6yw
    @Arunkumar-fn6yw 7 років тому +1

    very good way to explain

    • @FORYOU1
      @FORYOU1  7 років тому

      Arun kumar
      thanks boss....

    • @vinodchand7639
      @vinodchand7639 6 років тому

      correction should be necessary about this part of lesson.

  • @muhammadayyub3525
    @muhammadayyub3525 6 років тому

    Very helpfull vidoe

  • @anilpatil6616
    @anilpatil6616 6 років тому +1

    Wonder explain sir I want more your vedio such as break water piles and any thing related to port

  • @muhammadumer696
    @muhammadumer696 5 років тому

    Nice video sir

  • @eidwalikhan5752
    @eidwalikhan5752 5 років тому

    Great sir

  • @muhammadshahid9199
    @muhammadshahid9199 7 років тому +2

    sir you have estimating and coasting i-e short wall and long wal problem?

  • @m.haroonkhan1348
    @m.haroonkhan1348 7 років тому

    awesome vedio

  • @mahgaming1685
    @mahgaming1685 4 роки тому

    sir one question.. when we calculate the weight of steel for a column or a slab or beam...is the overlapping length taken into account

  • @RkYadav-9598
    @RkYadav-9598 7 років тому

    Thank you so much sir....

  • @asfandyar134
    @asfandyar134 2 роки тому +1

    Sir Har koi apni taraf say 40D and 50D and 60D laga raha Hai Lap length keh liyeh. Per koi nahin batata keh yeh 40d and 50d kahan say derive huwa.

  • @zaaya3629
    @zaaya3629 Рік тому

    Is Overlapping possible at tension zone?

  • @hasnainshah2276
    @hasnainshah2276 3 роки тому

    Sir kindly make a vedio on how we can calculate the weight steel like 3 sutter 4, 6 etc

  • @mdkhadarpasha961
    @mdkhadarpasha961 7 років тому

    sir please rpl me ...columns may tensile zone and comprehensive zone hota hai kya ya hota hai tho uska video banavo na sir plz rpl this comment....

  • @kotakalyanram9468
    @kotakalyanram9468 6 років тому

    Please explain the difference between pre tension and post tension and its uses

  • @sharib4523
    @sharib4523 7 років тому

    sir ye konse grade k lye use krna h?? maine new video dekha h..usme s kisi grade s match nai ho raha..

  • @ibnadam9964
    @ibnadam9964 7 років тому

    Sir kindly recommend designing software apart from. Auto Cadd, where we can draw plans of buildings etc...

  • @techinvented5430
    @techinvented5430 7 років тому +12

    Lapping length of bar should be
    • Horizontal members 60d
    • Vertical members 50d
    (unless mentioned otherwise)

    • @FORYOU1
      @FORYOU1  7 років тому +1

      Tech Invented
      dakho ya minimum hy .......jo ma ny btaye.....boot sy different standards be hyen

    • @malikarfan8759
      @malikarfan8759 7 років тому +3

      There is different standard,, but as per ACI( American concrete Institute) in Arab Country
      Lapping length of bar should be
      • Horizontal members 40d
      • Vertical members 60d

    • @kartikbedi
      @kartikbedi 6 років тому +2

      bro u need to chk whtr tht str. is in compression or in tension and what is the grade of concrete and steel used so thr r different parameters which leads to design of Ld. To kuch fix nahi hoota these parameters r different at different places so designer sb dekh k deeta h comptn vaale components like column and tension vaale components like beam and slabs is m jon sa max hoota h use vo genreal notes m de deeeta h

    • @saeelourrahman834
      @saeelourrahman834 5 років тому

      @@malikarfan8759 Bhai 45d where d is dia of bar in column and in beam used 50d

    • @jobspeshawar3790
      @jobspeshawar3790 2 роки тому

      @@malikarfan8759 Slam Arifen bahi ,

  • @ronyangral7874
    @ronyangral7874 7 років тому +1

    Gud explain sir

  • @abdulahkhan6927
    @abdulahkhan6927 6 років тому

    Sir continues beam me laping kahan krni chaheye i mean beam k centre me?? tensile zone me and comprssion zone me???

  • @VivekKumar-bk2ig
    @VivekKumar-bk2ig 4 роки тому

    Sir if we drill into old coulmn and put the bars into the holes without lapping

  • @gamingmasterjak7467
    @gamingmasterjak7467 3 роки тому

    If both overlapping bars have different dia then which Dia will be used to calculate overlapping?

  • @sharadpatel436
    @sharadpatel436 6 років тому

    very good

  • @amadhussain5009
    @amadhussain5009 6 років тому

    ft videou ha bhi thanks

  • @sajalrahaman4719
    @sajalrahaman4719 5 років тому

    G+2 house banane ki liye column and beam me size and number of bar kitna Dena parega ??

  • @XYZ-ff5kv
    @XYZ-ff5kv 5 років тому

    Thanku brother

  • @jayvachhani1201
    @jayvachhani1201 6 років тому

    Total station pe video bna do to help ho jayegi sir

  • @nehakamdi6363
    @nehakamdi6363 6 років тому

    sir is tension &compression zone &tension and compression member is different

  • @chajaykumar7680
    @chajaykumar7680 5 років тому +1

    Sir in ur video once u said for slab 6od bemas 60d for coulmn 45d. ... Now u saying another plzz clarify im totally confused

  • @sharath8chai
    @sharath8chai 7 років тому

    brother. in beam we can say that there is compression and tensile forces. but in columns? how that two forces will act? column is straight structure right?
    please tell me that column forces. thank you brother

  • @Ajay_ojha872
    @Ajay_ojha872 6 років тому

    Thanks bro

  • @civilengineeringbasicknowl4987
    @civilengineeringbasicknowl4987 6 років тому

    Bht acha

  • @muhammadakbar505
    @muhammadakbar505 7 років тому +2

    plz sir crass section s me bare min bhi batao Jo him drowing min read kirte him
    sub we achi bat asp ki video ki he hi asp Urdu min simjhste him
    thanxxxxxxx

    • @FORYOU1
      @FORYOU1  7 років тому +1

      Muhammad Akbar
      akbar ma sab sekhany wala hoo....tension na lo....ap sab sekho gy is platform sy.....bas tora sa wait karo...step by step sekhaoen ga.....

  • @CivilEngineersChoice
    @CivilEngineersChoice 5 років тому

    Good

  • @shoaibchauhan4516
    @shoaibchauhan4516 6 років тому

    Agr sir humare pas bottom ki bar 12 h or upper ko or 16 ka bar start to lap kitne ka lag e ga

  • @shubhamchaudhary5376
    @shubhamchaudhary5376 7 років тому

    Sir... Aap ne mention ni kiya yaeh M20, M25, M30... Konse grade ki concrete k liye h...

  • @raththai6015
    @raththai6015 7 років тому

    Dear sir, I am an engineering student. I don't understand about standard hook for main bar and stirrup. Could you explain about it?

  • @asadali1901
    @asadali1901 6 років тому

    thanks sir ji

  • @yogeshmore1609
    @yogeshmore1609 5 років тому

    sirji pliz ye hum engg ke satisfaction ke liye nahi late lapping .. its realy important all steel and slab structure .. never take any risk of collapsing slabs

  • @aliimam7097
    @aliimam7097 6 років тому

    sir Mai first time Sona Hai ki compressive zone 24d dete Hai

  • @umakant8804
    @umakant8804 6 років тому

    भाई स्लैब में is स्टैंडर्ड के अनुसार कितना परसेंट ओवरलैप स्टील डाल सकते हैं

  • @pramodkumar-by2us
    @pramodkumar-by2us 6 років тому

    Sir ye concrete grade pr depend nhi karta kya

  • @sasankabiswasray
    @sasankabiswasray 5 років тому

    Hello friend column is compressive member.

  • @saimhyder9468
    @saimhyder9468 6 років тому

    what is standard overlapping length is required for columns having 16, 20, 25 mm bars

  • @m.maheshkumar1288
    @m.maheshkumar1288 6 років тому

    if the beam simply supported continues and c/c of column 7.5m with connected with 10 column...and I worked out in some span100% lap falling ..how to avoid those area..but you are saying if beam rebar 4 at top then provide 2 lap at one span and 2 lap at another span it mean only 50%lap.....but my condition it's not work out...its falling 100%lap...whats alternate solution...?

  • @contragameplay6430
    @contragameplay6430 7 років тому

    ek soot may itnay mm hotay hai? Aur 8mm dia wali bar kitnay soot ki hoti hai?

  • @prashantkiranwal1536
    @prashantkiranwal1536 7 років тому +2

    Is over-lapping depand on grade of concrete or not? because at my site it is given as m40 ke liye 36d, m25 ke liye 49d please tell me what is the reason sir ji

    • @FORYOU1
      @FORYOU1  7 років тому +1

      Prashant Kiranwal
      yes os sy be related video bna raha hoen tension na lo....

    • @ashishdubey1864
      @ashishdubey1864 6 років тому

      kb tk banayege

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 років тому

      ua-cam.com/video/j58hNcejl0c/v-deo.html

    • @rakhisomawat8517
      @rakhisomawat8517 6 років тому

      Prashant Kiranwal bhai isko khud ni pta terko kha se btayga and lapping concrete grade pr hi depend krti h

  • @johnabbas7253
    @johnabbas7253 7 років тому +1

    great

  • @akhtarali-cm5kb
    @akhtarali-cm5kb 7 років тому

    sir FPS mein formula kya hoga?

  • @adilelefrezac7451
    @adilelefrezac7451 5 років тому

    Sr meri slep se ek fit steel nikli hai colam ki kya kare

  • @chandreshkushwaha1456
    @chandreshkushwaha1456 7 років тому

    sir site p jo plane milta hai usko pura kaise samghe usko pura explane karke batai apne vedio lecture m pless sir

  • @prateekdave3048
    @prateekdave3048 6 років тому

    Sir hume kese pta chalega ki konsa tensile zone h aur konsa compression zone??

  • @moonis383
    @moonis383 7 років тому

    how to take level on site prior to construction or kis k respect me levelling karte hai and it's purpose.please make video

  • @AhmedKhan-jr7el
    @AhmedKhan-jr7el 5 років тому

    Concrete structure kesy calculte krty hain

  • @ibnadam9964
    @ibnadam9964 7 років тому

    How much overlap is provided in, column, bridge abutments, piers with mix.. Sir kindly throw light on it!!

  • @pranavnaxane2252
    @pranavnaxane2252 6 років тому

    Brother..do refer IScode section...etc..etc..

  • @wonderingcivil8808
    @wonderingcivil8808 7 років тому +1

    thanks

  • @nazirkhan3089
    @nazirkhan3089 2 роки тому

    Hello sir civil engineering me ik acha engineer ko keya ani chaye Sir please

  • @jigneshbhatt7465
    @jigneshbhatt7465 4 роки тому

    sir aap ye 40d,50d 24d jo value he vo kaise li IS code me ye chiz kaha pe he please hame bataye

  • @govindakilaparthi6808
    @govindakilaparthi6808 6 років тому

    Thnx sir

  • @TiroleG777
    @TiroleG777 6 років тому

    Sir column ka bhi detail btavo

  • @civilsites.sharma2668
    @civilsites.sharma2668 7 років тому

    sir aap ek video column lap ka (column ke uper ka L wala)

  • @saadfawad1699
    @saadfawad1699 6 років тому

    Bro can u recommend us what type of software we use in site engineering

  • @anthonychibuike488
    @anthonychibuike488 7 років тому

    please sir can you explain how you have slab as 50d

  • @DeepakSharma-oi8wy
    @DeepakSharma-oi8wy 6 років тому

    Centimeter me bataye kitna over lagana h pls

  • @Mahi1609
    @Mahi1609 6 років тому

    Dost mujhe interview me yhi pucha tha, can u explain, kon se code me aur proper page no bta k tensile zone 40d aur compression zone 24d diya h.. Plz reply krna..

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 років тому

      you say, we all refer to latest IS Code 456 : 2000, IS 456 drived from SP 24 Is Codes standard Book of BIS

    • @Limitless93
      @Limitless93 6 років тому

      bahut acche my questin is to be same

  • @abdulahkhan6927
    @abdulahkhan6927 6 років тому

    sir i have a request ..
    sir i have a circle 50 feet Dia steel kis trhan find kareingy???

  • @pervaizhashmi1037
    @pervaizhashmi1037 5 років тому

    brother please tells us that these number or formulas according to which IS Code?

  • @lightningspeedhawk1341
    @lightningspeedhawk1341 7 років тому

    is it according to IS 456
    is it applicable in india ?

  • @ankushshingetikar3431
    @ankushshingetikar3431 7 років тому

    sir how to use a leveling tube in construction buildings

  • @riyazshah4915
    @riyazshah4915 7 років тому

    sir a Jo laping hain grade of concrete or grade of steel me defended hote to app to app beam ka bola laping column ka vi boliye concert or steel mey

  • @raiyanahmad8653
    @raiyanahmad8653 6 років тому

    Compression zone 50d Lena hota h.. plz.. u confirm... Kre .

  • @samarzaman3945
    @samarzaman3945 6 років тому

    Sir aghar loping 75 say zid ho jay to koi problem to neah hay na

  • @burhanuddinbohra326
    @burhanuddinbohra326 7 років тому +1

    sir suppose if column contains 4_8# bars and 4-16# bars..then how we decide lapping length for two diameters..?

    • @dharminpatel3058
      @dharminpatel3058 7 років тому

      BuRHaN MEGATROn 8# will connect to 8# bars only.. so for this size of bar use formula for 8# and for 16# use their formula.. we dnt have to connet two different size bar wd each other.. lapping will be done on same size of bars only... So no need to confused between which dia should be use in formula..

    • @dharminpatel3058
      @dharminpatel3058 7 років тому

      BuRHaN MEGATROn for both 8# and 16# Lapping distance will be different according to dia

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 років тому

      Sir, I got your point, if you are going to lap different dia of Bars - Mean 20mm > 16mm (Reducing dia of bar when columns going up), you have to consider lap length only minimum Dia of Bar, which is 16mm dia. Its define in code IS 456, & BS 8110.

  • @sohaibburhan1543
    @sohaibburhan1543 6 років тому

    what is tension and compression zone in a column.can u explain plz.

  • @manjeets236
    @manjeets236 6 років тому

    Aap zyada chinteet rehete hain isko lekar ki like karo, share karo and subscribe karo. Agar aapka focas detailing per hoga to jyada achhi video banegi. Knowledge to dete ho but saath hi saath confuse bhi karte ho.

  • @saddamhussiankhan2141
    @saddamhussiankhan2141 7 років тому +5

    Sir video ki clearly nahi aati Plzz aap use khyal kare...

  • @tashqeenahmad2644
    @tashqeenahmad2644 7 років тому

    kisi building k column m kitne mm ka steel rod lagega ye kaise pata karte hai

  • @saurabhsrivastav2610
    @saurabhsrivastav2610 4 роки тому

    kon se bar ka bata rahe ho

  • @vikaskumar2816
    @vikaskumar2816 7 років тому +4

    sir 24d pehli baar sun rha hun. this is too short....

    • @FORYOU1
      @FORYOU1  7 років тому +2

      Vikas Kumar
      this is minimum over lap.....boss.....

    • @FactualCivilEngineering
      @FactualCivilEngineering 6 років тому

      Please refer IS 456, or BS 8110 for better understanding of technical aspects of Over Lapping

  • @naanu0073
    @naanu0073 4 роки тому

    See IS 13920(2003) ,CL -6.2.6
    FOR Compression : 40D
    For tension : 50D

  • @Engrnawaz
    @Engrnawaz 7 років тому +1

    please ft mn samjhaen