GLAND SEAL STEAM SYSTEM| PART-1|GLAND STEAM CONDENSER| SHAFT SEAL| SEALING MECHANISM

Поділитися
Вставка
  • Опубліковано 31 жов 2023
  • GLAND SEAL STEAM SYSTEM| PART-1|GLAND STEAM CONDENSER| SHAFT SEAL| SEALING MECHANISM
    #turbine #ntpc #educationalvideo #education #viral #training #trending #dvc #powerplant

КОМЕНТАРІ • 41

  • @deepakkewat3547
    @deepakkewat3547 3 місяці тому

    Dear sir please make video on boiler emergency conditions and shutdown time activity for desk operation

  • @Mayank14755
    @Mayank14755 6 місяців тому

    Thankyou sir. Didn't knew anything before video. But explanation was so, i understood everything you taught.

    • @rahulsirclasses1987
      @rahulsirclasses1987  6 місяців тому +1

      Thanks

    • @Mayank14755
      @Mayank14755 6 місяців тому

      @@rahulsirclasses1987 Sir one request pls make video on boiler side also.
      Like
      Air flow control loop. O2 trimming.
      Hot flue gas control loop.
      Fuel master
      CMC etc. it will be very helpful.

    • @rahulsirclasses1987
      @rahulsirclasses1987  6 місяців тому

      Ok ,I will make video on this topic.

  • @pranaykumar5683
    @pranaykumar5683 8 місяців тому +1

    Please upload video on seal oil system 500 MW and 200 MW both,
    H2 side seal oil pump , Air side seal oil pump etc

  • @user-sq4xr6qg2v
    @user-sq4xr6qg2v 8 місяців тому +1

    Sir valve k bare . Bta dijiye Jo plant me use hota hai

    • @rahulsirclasses1987
      @rahulsirclasses1987  8 місяців тому +1

      Ok.please give me time I will make video on this topic.This is important topic.

    • @user-sq4xr6qg2v
      @user-sq4xr6qg2v 8 місяців тому +1

      @@rahulsirclasses1987 ok sir. Valve bahut Sara hai kon sa kaha lga hai smjh m hi nhi ata

  • @0503manoj
    @0503manoj 2 місяці тому

    Sir vacuum pulling karte time gsc fan kab start karna hai.. Either after starting of vacuum pump or after charging of gland sealing steam

  • @DEEPCHAND-mb2xh
    @DEEPCHAND-mb2xh Місяць тому

    Sir .. steam sealing and gland sealing m difference kiya hai

  • @shailendrasinghpatel1427
    @shailendrasinghpatel1427 4 місяці тому

    Sir blowdown ka video hai kya

  • @motive0507
    @motive0507 6 місяців тому

    Why there is a connection from CRH along with Aux PRDS for gland sealing

    • @rahulsirclasses1987
      @rahulsirclasses1987  6 місяців тому

      There is another provision of steam source for gland seal steam charging.In some case where there is one unit only, no interconnection of PRDS .

    • @motive0507
      @motive0507 6 місяців тому

      @@rahulsirclasses1987 I think seal steam charging has done before firing in the boiler, then what is the purpose of taking steam from CRH line

  • @shailendrasinghpatel1427
    @shailendrasinghpatel1427 2 місяці тому

    19:35 sir Jo steam hai wo Hp, IP, OR LP thino se leak kartha hai ya sirf Hp , Ip se leak kartha hai.

    • @rahulsirclasses1987
      @rahulsirclasses1987  2 місяці тому

      Leakage from HPT &IPT ONLY
      leakage steam supply to the gland of LPT as it is connected to vaccum , exhaust pr is less than atmospheric

  • @avinashtiwari1410
    @avinashtiwari1410 6 місяців тому

    Sir hp dosing aur LP dosing kab aur karte please bataiye?

  • @shailendrasinghpatel1427
    @shailendrasinghpatel1427 4 місяці тому

    Sir lightup process ka video banaya, kab kon sa drive start karna hai or parameters kya rahega or kis parameters ko dekh kar driver start karenge

  • @shailendrasinghpatel1427
    @shailendrasinghpatel1427 4 місяці тому

    Sir in my plant self sealing start at 100MW ( 250 MW UNIT) ITS MORE THAN 35%. WHY

  • @computercentre12345
    @computercentre12345 6 місяців тому

    Maw 10 and MAW 50 oil operator vlv having oil motor

  • @avinashtiwari1410
    @avinashtiwari1410 4 місяці тому

    GSC kya hota hai sir

    • @rahulsirclasses1987
      @rahulsirclasses1987  4 місяці тому

      GSC means gland steam condenser which is used in condensate water cycle to heat the condensate water by gland steam of turbine

  • @manasdas740
    @manasdas740 6 місяців тому +1

    Why gland sealing is charged after taking hoggard after attaining slight vaccum.

    • @rahulsirclasses1987
      @rahulsirclasses1987  6 місяців тому +1

      Cold start up:
      In this turbine is in atmospheric temperatures, hence gland steam is charged after vacuum pulling at vacuum say -0.2 to -0.5 kg/cm2. If gland sealing is done before vacuum pulling, there may be chances of developing thermal stresses.
      Hot start up:
      Gland sealing is charged even before vacuum pulling. Charging the gland seal steam after vacuum pulling may cause cold air shock in the glands which may lead to rotor distortion

    • @manasdas740
      @manasdas740 6 місяців тому

      Really clarified my doubt.Thanks Sir🙏

    • @shailendrasinghpatel1427
      @shailendrasinghpatel1427 2 місяці тому

      ​@@rahulsirclasses1987 Sir is this same for warm Starup also

    • @rahulsirclasses1987
      @rahulsirclasses1987  2 місяці тому

      @@shailendrasinghpatel1427 yes

    • @rahulsirclasses1987
      @rahulsirclasses1987  2 місяці тому

      To improve the vacuum ,prevent ingress of air into turbine