Це відео не доступне.
Перепрошуємо.

GLAND SEAL STEAM SYSTEM|PART-2| SEAL STEAM CHARGING PROCEDURE|PRE CHECK CONDITION|WITHDRAW CONDITION

Поділитися
Вставка
  • Опубліковано 1 лис 2023
  • GLAND SEAL STEAM SYSTEM| SEAL STEAM CHARGING PROCEDURE|PRE CHECK CONDITION| WITHDRAW CONDITION
    #turbine #ntpc #powerplant #nptel #thermalplant #dvc ##educationalvideo #training #viral #education #youtube

КОМЕНТАРІ • 23

  • @Mayank14755
    @Mayank14755 7 місяців тому +1

    Thankful to you sir 🙏 ❤️ 🙌

  • @pranaykumar5683
    @pranaykumar5683 9 місяців тому +5

    Sir please make a video on
    Turbine follow mode
    Boiler follow mode
    CMC
    Pressure control, load control, speed control,
    EHC , HC

    • @rahulsirclasses1987
      @rahulsirclasses1987  9 місяців тому +1

      I have already made a video on EHC, Pressure control,load control and speed control and uploaded ,you may go through my channel

  • @manasdas740
    @manasdas740 9 місяців тому

    Sir plz upload video on Boiler Protection

  • @kumardeepak7935
    @kumardeepak7935 9 місяців тому

    ❤ Please make videos over run back and rundown opc sps

  • @rahulsirclasses1987
    @rahulsirclasses1987  9 місяців тому +3

    Any doubt regarding charging of gland seal steam system ,you may raise in comment box,I will reply.

  • @nileshchothave8065
    @nileshchothave8065 9 місяців тому +1

    Plz make video on after tripping how to charge PRDS nd how to seal Turbine

    • @rahulsirclasses1987
      @rahulsirclasses1987  9 місяців тому

      I have already made a video on gland seal steam charging procedure.
      I will make video on PRDS charging

  • @swarnmishra4405
    @swarnmishra4405 Місяць тому

    There will be one more problem. If we cut seal steam before killing vacuum, air will ingress through gland seal and will cool the gland seal strips. As the profile of seal strips is very thin, they will contract and touch the shaft. Shaft being thick in profile will not contract in the same pace. This will cause jamming of rotor

  • @0503manoj
    @0503manoj 3 місяці тому

    Sir GSE fan kab start karne ka sequence kya hai

  • @kashpandya5321
    @kashpandya5321 5 місяців тому

    Nice explanation Sir. By the way I am working on a project where OEM has quoted steam turbine ( HP and LP two separate cylinders) without Gland Steam Condenser. Have you heard or it it practical to accept ST without GSC ?
    Can we discuss?

    • @rahulsirclasses1987
      @rahulsirclasses1987  5 місяців тому +1

      Generally GSC is used to extract the heat from the gland steam to heat condensate water.Most of the plant used GSC.It may be some other design aspects to utilise the gland steam .
      Turbine having seal present on both end to avoid the steam loss from their ends .

    • @kashpandya5321
      @kashpandya5321 5 місяців тому

      Thank you so much

    • @kashpandya5321
      @kashpandya5321 5 місяців тому

      I have sent you an email. Also one quick question. Approximately how much percentage of cycle efficiency we are gaining by recovering heat from GSC to condensate water ? Less than 0.5 % ?

    • @rahulsirclasses1987
      @rahulsirclasses1987  5 місяців тому +1

      Approx 0.2-0.3

    • @kashpandya5321
      @kashpandya5321 5 місяців тому

      Thank you so much

  • @computercentre12345
    @computercentre12345 9 місяців тому

    Sir Is MAW10 15 is air operated or motor operated pneumatic vlv?