Manitowoc ice machine long harvest alert

Поділитися
Вставка
  • Опубліковано 27 лис 2024

КОМЕНТАРІ • 17

  • @92Blackjeep
    @92Blackjeep 10 днів тому +2

    10 yrs working solely on ice machines and ive NEVER come across a fan cycle switch that caught in fire. Plenty of mani fcs's intermittently failing open. nice find. now ill probably see one next week

    • @IceMachine411
      @IceMachine411  10 днів тому

      10 years is impressive! I’m sure you’ve seen some crazy stuff out there.

  • @michaelcave9071
    @michaelcave9071 10 днів тому +1

    You are the Ice Machine Guru!!!

    • @IceMachine411
      @IceMachine411  10 днів тому

      My friend from the UK! Good to see you Michael.

  • @fshn76
    @fshn76 12 днів тому +1

    That switch was a little crispy!cool find.

  • @MrMultitool
    @MrMultitool 12 днів тому +1

    I'm very surprised that it wasn't leaking.

  • @bensreferigeration
    @bensreferigeration 12 днів тому +1

    Nice video. Im sure this has been asked before, but does your company only do ice machines?

    • @IceMachine411
      @IceMachine411  11 днів тому

      Almost only ice machines. We dabble in refrigeration when we get presented with an opportunity.

  • @josemartinez-jt6tw
    @josemartinez-jt6tw 8 днів тому +1

    I must say your the best im tech ive seen.

    • @IceMachine411
      @IceMachine411  7 днів тому

      Thank you for the compliment. There are better technicians out there and that’s a fact.

  • @zekenzy6486
    @zekenzy6486 11 днів тому +1

    Great video. Thank you for sharing. Have a nice weekend. May I ask ? How to know which one is Fans cycle switch , High pressure switch, low pressure switch ? How to identify them . I kinda confusing on those one.

    • @IceMachine411
      @IceMachine411  11 днів тому

      Looking at the markings on the switch is a good way to know which switch is what. There are usually pressure ratings on the switch. 450 psi being high pressure cut out, 250-300 being fan cycle and 15-35 being low pressure. You could also trace the wires to figure out where it runs and then reference the wiring diagram. Wires going to the condenser fan would be a fan cycle switch. The hard part is that each machine is slightly different. Wiring diagrams help. Parts breakdown is also a good help. Hope this was useful. Hope you have a great weekend.

  • @MrIDONTKNOW01
    @MrIDONTKNOW01 12 днів тому +1

    I can tell you’re working at a Dutch bros lol

    • @IceMachine411
      @IceMachine411  11 днів тому

      lol. They all look the same.

    • @MrIDONTKNOW01
      @MrIDONTKNOW01 11 днів тому

      @I say that all the time. I forget which store I’m at. I do PMs on Dutch bros in San Antonio and it’s really funny seeing you talking about those fan cycle switches after seeing one that was bad a few days ago.