Hoshizaki ice machine not working - bin control

Поділитися
Вставка
  • Опубліковано 23 лис 2024

КОМЕНТАРІ • 49

  • @HVACRVIDEOS
    @HVACRVIDEOS 11 місяців тому +13

    Awesome stuff bud! Its crazy that evap is already going bad I can tell its been replaced before too... the quality just isn't there anymore with the Hoshi machines

    • @IceMachine411
      @IceMachine411  11 місяців тому +6

      Those burn marks are a dead giveaway lol. You’re 100% right about the quality going down hill. I’ve only been doing this for about 3 years and I’ve noticed it myself.
      Also. Big fan of your work. Super cool to get a comment from someone that my coworkers and I have watched and learned from over the years.

  • @MariosACandRefrigeration
    @MariosACandRefrigeration 11 місяців тому +3

    The way you found the ice on the shoot, is saying bin control.good call thanks for sharing.

    • @IceMachine411
      @IceMachine411  11 місяців тому

      Wish it was the first thing I checked.

  • @navjotsingh-lr6nn
    @navjotsingh-lr6nn 11 місяців тому

    Thank you . Way you tell so easy and understandable. Thank you huge respect.

    • @IceMachine411
      @IceMachine411  11 місяців тому

      Appreciate the compliment and support. Thank you.

  • @hist-explore7909
    @hist-explore7909 11 місяців тому +1

    Thanks for this video i keep on watching bro. Watching from uae

    • @IceMachine411
      @IceMachine411  11 місяців тому +1

      UAE! Was there in 2012. Al Dhafra AB. Glad to know you hist-explore.

  • @ronaldinabinet7750
    @ronaldinabinet7750 4 місяці тому +1

    At first I thought the refrigerant was low or condenser/cleaning issues the problem. A lesson was learned! That was a good infestation....

    • @ronaldinabinet7750
      @ronaldinabinet7750 4 місяці тому

      Investigation...

    • @IceMachine411
      @IceMachine411  4 місяці тому

      Lol

    • @IceMachine411
      @IceMachine411  4 місяці тому

      It was tricky. I almost missed it. Speaking of infestation. Have you ever seen critters in an ice machine?

    • @ronaldinabinet7750
      @ronaldinabinet7750 4 місяці тому

      Not yet... I'm just trying to help out a small bar close to me!

  • @keovongvilaykeo4799
    @keovongvilaykeo4799 11 місяців тому +2

    Thank you 🙏 always great video 😊

  • @crystalcleanappliance5903
    @crystalcleanappliance5903 11 місяців тому +1

    I thoroughly enjoy these videos!! new subscriber.

    • @IceMachine411
      @IceMachine411  11 місяців тому

      Share these videos with people you know who are interested in learning about ice machine service. Many more posts to come. My goal is 1000.

  • @Shawn_RHVAC
    @Shawn_RHVAC 11 місяців тому +1

    Definitely looks like the bin control failed and allowed the ice machine to run and fill up into the chute and once the curtains opened the machine turned off. The buildup of ice in the chute froze up and once the ice in the bin was used up the switch may or may not have reopened, but the chute was now plugged up. Just my thoughts and experiences

    • @IceMachine411
      @IceMachine411  11 місяців тому

      Definitely looks like that. 👍🫡

  • @MrJEEPJT
    @MrJEEPJT 11 місяців тому +1

    Excellent video 👍👍 due to the background noise couldn’t hear your comments on the dip switches. I haven’t gotten the opportunity to work on Hoshizaki’s in a few years. I recall tech support mentioning the dip switches “1” and “2” and the importance of the Internal diameter of the inlet water lines feeding the ice machines being very important. So many of the ice machines regardless of the brand were crammed into small spaces and fed with braided water hoses which restricted the proper water flow.
    Can you comment on recommendations on the dip switches settings based on some of the conditions you find ???

    • @IceMachine411
      @IceMachine411  11 місяців тому

      Yes it was loud. I don’t really mess with any of the dip switches except for dip switch 1 & 2. I won’t change any other switches unless I’m being told by tech support or I have something in writing that says to change them.
      1&2 off = shortest harvest
      1&2 on = longest harvest
      Watch a harvest cycle and if there’s still cubes on the evaporator then turn on dip switch 1&2. (assuming everything else is correct)

    • @MrJEEPJT
      @MrJEEPJT 11 місяців тому

      Yes longest harvest wasn’t 1 of those switches for a longer flush cycle ??

    • @IceMachine411
      @IceMachine411  11 місяців тому

      Maybe. I’d have to read the manual, don’t have it memorized.

  • @ryancolbert1701
    @ryancolbert1701 8 місяців тому +1

    Nice vid, good explanations.

    • @IceMachine411
      @IceMachine411  8 місяців тому

      Right on bro! I appreciate your compliment. I hope you got some value out of this video.

  • @zekenzy6486
    @zekenzy6486 10 місяців тому

    Great Video. Thank you for sharing

  • @shine-cg9uf
    @shine-cg9uf 11 місяців тому +1

    🇺🇸💪👍❄️ great informative video thanks for sharing much appreciated

    • @IceMachine411
      @IceMachine411  11 місяців тому

      You’re welcome! Good to see you again!

  • @michaelmooreargumentativespeec
    @michaelmooreargumentativespeec 10 місяців тому

    Yoooooo you’re a tech too? It’s Moore.. I found your video trying to diagnose a Hoshizaki

    • @IceMachine411
      @IceMachine411  10 місяців тому

      What’s up buddy!? Email me. Icemachine411@gmail.com. Maybe I can help you out.

  • @EdwardOrozco12
    @EdwardOrozco12 11 місяців тому

    awesome stuff

  • @raviyadav8743
    @raviyadav8743 9 місяців тому

    Thanks for sharing,

  • @santoshsubedi9449
    @santoshsubedi9449 8 місяців тому

    what to do if the ice machine is making ice but not falling even after changing float switch, control board water inlet valve and water filter. Also cleaned the whole ice machine

    • @IceMachine411
      @IceMachine411  8 місяців тому

      Does the machine cycle into harvest? What are your harvest pressures? How is your water flow down the center of your evaporators? Is your thermistor working properly? Is the evaporator clean? There are lots of possibilities. It’s really hard to diagnose without knowing the specifics.

  • @ASKIBHIPR
    @ASKIBHIPR 9 місяців тому

    Got a question 🙋 about the evap crome plates
    Change is not easy?????

    • @IceMachine411
      @IceMachine411  9 місяців тому

      Change is not easy. Don’t do it unless you’re with someone who has done it before.

  • @frankevans588
    @frankevans588 11 місяців тому

    Good stuff brother, just subd

  • @criticaltemperature3343
    @criticaltemperature3343 11 місяців тому

    Man, i haven't worked on a hoshizaki in years. Frankly im not a fan either. Is that a KM series machine by chance ?

    • @IceMachine411
      @IceMachine411  11 місяців тому

      It’s either a KM or KML. I can’t remember off the top.

  • @harrydickson4575
    @harrydickson4575 11 місяців тому +1

    👍👍👍

  • @chrissipple1018
    @chrissipple1018 11 місяців тому

    Hoshizaki needs to go back to old bin switch.

  • @taylorcartwright2601
    @taylorcartwright2601 11 місяців тому +1

    Hoshizaki? More like hoshiduki!