GFCI Outlets: How They Work And New Requirements

Поділитися
Вставка
  • Опубліковано 16 бер 2023
  • In this video you'll learn how a GFCI receptacle works, new 2023 requirements and why they are critical for life safety. GFCI protection requirements have expanded in 2023 and I'll go over the three major changes so you have all the latest information needed for your next project.
    🎁 My Favorite Electrical Tools
    ⚡️Wire Strippers - amzn.to/3RpbeiC
    ⚡️Linemans Pliers (with Crimper) - amzn.to/3ReM6tI
    ⚡️Diagonal Pliers - amzn.to/3sSBQz7
    ⚡️Electrical test kit: amzn.to/3ZUiKDY
    ⚡️Wire Strippers: amzn.to/4061YBC
    ⚡️Electrical screwdriver set: amzn.to/3yGbzmV
    As an Amazon Associate, I earn from qualifying purchases with not additional cost to you.
    Other videos You may like:
    Receptacle Orientation - • Are your outlets insta...
    Electrical Pigtails - • Should you pigtail you...
    Gas Can Mods - • Fix a New Gas Can in 4...
    Subscribe here.. It's free and will help youtube recommend future videos from my channel. ua-cam.com/users/BackyardMai...
  • Навчання та стиль

КОМЕНТАРІ • 120

  • @BackyardMaine
    @BackyardMaine  Рік тому +3

    If you like electrical related content check out this playlist here: ua-cam.com/play/PLNTCwOMUgw1pnPfaoX5ZcjkhqyGSzRDVe.html and if you would like to subscribe to the channel you can do that here. ua-cam.com/users/BackyardMaine Thanks for being part of the Backyard Maine community.

    • @AARON10B
      @AARON10B 5 місяців тому

      Great channel and video John! I have a question, our house was built in 1983 and recently we thought we had a dead non-GFCI receptacle in the front bathroom. So I decided to upgrade it to a new GFCI receptacle with usb ports for my wife. I then realized that it was on the same circuit as the receptacle in the master bath that is a GFCI receptacle, and read that you shouldn’t put more than one GFCI receptacle on the same circuit (you can but it may cause some issues). So I made the decision to put the new GFCI receptacle with usb ports in the master bath and buy a new regular duplex receptacle with usb ports in the front bathroom. So now, after watching your video, I wonder if I should put a GFCI receptacle in the front bathroom as well as the master on the same circuit?
      I understand that not all codes apply to both new construction and remodel/retrofits, I would just like to do whatever is the best and safest for my family. Any assistance you can give me is greatly appreciated!

    • @BackyardMaine
      @BackyardMaine  5 місяців тому +2

      @@AARON10B Thank you.. GFCI protection is required in bathrooms but you don't have to have a GFCI receptacle in the bathroom to meet the code. The protection can come from a GFCI circuit breaker or from another GFCI located somewhere else in the home. I personally like to use the receptacles at point of use because if you trip it (which will happen) you can reset it right there. But the way you have it now is fine. Just be sure that it's connect correctly by testing it. Plug testers are cheap and I great tool to have around the house. You can find one at HD or Lowes with a button to test GFCIs. Just plug it into the non-GFCI in the bathroom, push the button and make sure it trips the one in the other room. Also I put several GFCI on the same circuit all the time and have never had a problem.

    • @watup110875
      @watup110875 5 місяців тому

      @@BackyardMaine thank for update, did not know that on GFCI

  • @JJSafetyLLC
    @JJSafetyLLC 5 місяців тому +2

    Great video! Thanks for covering the NEC 2023 GFCI updates at 5:00. Your videos are helping people stay safe.

    • @BackyardMaine
      @BackyardMaine  5 місяців тому

      Thanks my friend.. I try to help with my videos. I just uploaded a new one about 5 false statements about code requirements.

  • @davidholmes5910
    @davidholmes5910 Рік тому +5

    Great teaching videos, thank you. Your videos are concise and to the point.

    • @BackyardMaine
      @BackyardMaine  Рік тому +1

      Glad you like them! Much appreciated Sir.

  • @fitzgeraldgerundio8123
    @fitzgeraldgerundio8123 5 днів тому

    This is helpful for students like studying Basic Occupational Safety and Health. Thank you so much!❤

  • @danpags7023
    @danpags7023 Рік тому +3

    I appreciate your knowledge. I use your videos as a great resource to help me stay in code. Nice work on your presentation as well. Thanks

    • @BackyardMaine
      @BackyardMaine  Рік тому

      I appreciate that! I love to hear my videos are helpful to my viewers

  • @surferdude642
    @surferdude642 Рік тому +3

    Excellent demo and Information.

  • @jumpingsloth3963
    @jumpingsloth3963 Рік тому +1

    Just subbed and wanted to say thanks. Good information and learning. You deserve more subs.

  • @sjpropertyservices3987
    @sjpropertyservices3987 9 місяців тому +1

    Thanks for sharing.

    • @BackyardMaine
      @BackyardMaine  9 місяців тому

      Our pleasure! Thanks for watching.

  • @zacharykorbet9690
    @zacharykorbet9690 Рік тому +8

    You should do another video about all the changes in the electrical code. Just the ones that DIYs would use

    • @BackyardMaine
      @BackyardMaine  Рік тому +8

      I'm thinking about doing a series on that.. 1-3 minute videos on 2023 code changes. I'm just wondering if it would have enough interest?

    • @zacharykorbet9690
      @zacharykorbet9690 Рік тому

      @@BackyardMaine well I know I'd be interested LOL

    • @BackyardMaine
      @BackyardMaine  Рік тому +1

      @@zacharykorbet9690 Thanks Zachary.. I think I'll try a few videos and see how they perform. Stay tuned my friend.

  • @user-dh2wn5ux5q
    @user-dh2wn5ux5q 5 місяців тому

    Good work, clear and easy to understand!

    • @BackyardMaine
      @BackyardMaine  5 місяців тому

      Glad it was helpful! Thanks for watching

  • @jimcampbell5583
    @jimcampbell5583 Рік тому +1

    I love your videos. OMG were just all going to live forever if they keep adding all these restrictions

    • @BackyardMaine
      @BackyardMaine  Рік тому

      I know right. lol Thank you my friend. It's a lot of work putting these together and it's nice to read comments like yours.

  • @vince6829
    @vince6829 7 днів тому

    Love your videos. Thank you for sharing your knowledge.

  • @sophiarodriguez1861
    @sophiarodriguez1861 4 місяці тому

    Thank you so much!!

    • @BackyardMaine
      @BackyardMaine  4 місяці тому

      You're welcome! Thanks for watching.

  • @benstastic
    @benstastic 10 днів тому

    Great video as always - thank you.

    • @BackyardMaine
      @BackyardMaine  10 днів тому

      My pleasure! Thanks so much for watching my videos.

  • @wilbready
    @wilbready Рік тому +8

    I still find it troubling that they require GFCI outlets for refrigerators. I find that they will trip the GFCI receptacle and shut off the refrigerator causing food spoilage. What would you recommend? Also, how in the Halifax are we to GFCI protect a 30 amp dryer and what lead to that decision? Great video.

    • @BackyardMaine
      @BackyardMaine  Рік тому +3

      I agree. I think the refrigerator or a freezer should be exceptions. For a 30A dryer or a 50A range you would use a 2P-30A or a 2P-50A GFCI breaker. Remember you won't have to change an existing installation unless you're renovating or sometimes it's required as a condition of a sale. Dryers are usually beside the washing machine or part of the washing machine which present what's considered a significant amount of water over a gallon and is why the CMP (code making panel) voted to include them in the requirement.

    • @DavidGossMusic
      @DavidGossMusic 5 місяців тому +1

      There are GFCIs that have an audible alarm when tripped. Wouldn't help if you're away though.

    • @ranger178
      @ranger178 5 місяців тому +1

      the code making panel is getting ridiculously stupid @@BackyardMaine

    • @JohnSmith-ys4nl
      @JohnSmith-ys4nl 5 місяців тому

      @@ranger178 Fridges have become live and killed people (as have washers/dryers).

    • @ranger178
      @ranger178 5 місяців тому

      we had a old fridge that had a butter warmer compartment in the door, and you could get a shock from it if you opened the door and was touching something else and i would still never have a gfi on a refrigerator@@JohnSmith-ys4nl

  • @johnparkhurst825
    @johnparkhurst825 Рік тому +5

    would like to see a AFCI Video

    • @BackyardMaine
      @BackyardMaine  Рік тому +2

      I have that on my list as well. Stay tuned..

  • @alialshammary7188
    @alialshammary7188 Місяць тому

    thank you very much , you are amazing in explain

  • @chrshuston
    @chrshuston 27 днів тому +1

    It's crazy how little you talked about how they actually work in this video

    • @BackyardMaine
      @BackyardMaine  22 дні тому

      I find that with videos if I go deep into the actual way things work people eyes glaze over and my video retention is poor. I have to keep it to the basics but I could and happily would go into the details if I knew that would work.

  • @emmaezirim3153
    @emmaezirim3153 8 місяців тому

    ❤❤❤

  • @komalpreetkaur7940
    @komalpreetkaur7940 2 місяці тому

    Great content .

  • @patriciacunningham5748
    @patriciacunningham5748 5 місяців тому

    Thanks

  • @YoungLy-y9t
    @YoungLy-y9t 6 днів тому

    Can you use more than one GFCI coming from one breaker and what about the ground wires, use them or not or either or?

  • @duncanharris4723
    @duncanharris4723 11 місяців тому +2

    My house was built in the early 50s. So unfortunately, I don’t have a ground wires. Is it possible to use a GFCI outlets to get around rewiring my house for now?

    • @BackyardMaine
      @BackyardMaine  11 місяців тому +3

      Yes it is. GFCIs with still operate as designed without a ground and it will allow you to connect three prong plugs. The only thing is you need to put a sticker on each one indicating there is no ground.

  • @MrTherende
    @MrTherende Місяць тому

    What is the requirement for submersible water pumps (typically 240V, 20A circuit)? I would like to see a video on circuits that require BOTH AFCI and GFCI protection.

    • @BackyardMaine
      @BackyardMaine  Місяць тому +1

      Hard wired submersible well pumps do not require GFCI protection. If they are cord and plug connected they do. I put that video on my list. Stay tuned.

  • @Jorge-Molina
    @Jorge-Molina 3 місяці тому

    Does the receptacle in which the GFCI is installed have to be grounded for protection to be effective?

    • @BackyardMaine
      @BackyardMaine  3 місяці тому

      If you have a ground wire then you do want to connect it but to answer your question, the GFCI will still function properly with no ground.

  • @arthouston7361
    @arthouston7361 5 місяців тому

    I’d like to add something that is missing from that nice milliamp chart right at the beginning of this video. Back in the 1970s when I started doing electrical work for a railroad, we were taught that it only takes 6 mA flowing across your chest in order to send your heart into fibrillation, which can only be stopped with an AED device…and back in the 70s, none of us had those devices because they were only available in certain emergency service vehicles and were quite bulky, as they were the same units used in hospitals.

    • @BackyardMaine
      @BackyardMaine  5 місяців тому

      Thanks for the info..The chart I used was borrowed from an OSHA document and I believe those are the current numbers the industry is using today.

    • @arthouston7361
      @arthouston7361 5 місяців тому

      @@BackyardMaine Oh, they are, but they're not specific, and they neglect what happens when current passes across your chest just a little bit, because unless somebody is there that can defribrilate you if your heart goes into V-fib, you are a dead man.
      You have to remember that OSHA is not industry professionals. It's bureaucrats.

    • @BackyardMaine
      @BackyardMaine  5 місяців тому

      @@arthouston7361 I was the electrical engineer for a multi billion dollar corporation. We would occasionally get an OSHA audit and they would send experts in every area of expertise. Electrical, chemical, mechanical etc. The electrical guys from OSHA I worked with were experts who understood everything I showed them from 35kv distribution, generators, UPS systems, transfer switches, rotary UPS systems couples to generators, fire pumps, controls and everything else. The bureaucrats were not the guys in the field in my experience.

    • @arthouston7361
      @arthouston7361 5 місяців тому

      @@BackyardMaine The guys that they sent you that you are describing are part of a very specialized group.
      I've met the guys from OSHA who fit that category, but they're not the people that make the rules, and they're not the people who produce graphics. I didn't do any 35K work, but our railroad signal power on the former Penn Central was 8.8 kv. More than enough to send you to meet the great I am. Our power source was the old Philadelphia electric company, and so we had a lot of safety information that came directly from them.

  • @easternhops
    @easternhops Рік тому

    thanks fo rthe info I jave a GFI plug green light is on but no power is the plug no good and do I need to replace it? thanks Robert from Canada

    • @BackyardMaine
      @BackyardMaine  Рік тому +1

      That's an unusual problem. Check to make sure it's wired correctly first and that there are no loose connections. If everything looks good replace the receptacle.

    • @jonreedau81
      @jonreedau81 10 місяців тому +1

      It has probably failed- depending on when it was made as more recent GFCIs are designed to interrupt power delivery when they no longer provide GFCI protection.

    • @ranger178
      @ranger178 5 місяців тому +1

      some of them have a light to tell you outlet is on while others have one to tell you it has died

  • @user-gf2hu7mk7x
    @user-gf2hu7mk7x 4 місяці тому

    I recently took the National Home Inspector exam and this question came up. At what amp with the GFCI trip with human contact and 5 amp wasn't one of the answers had 4, 6, 10 and 12. Not sure if I got the answer correct I choose 6. Now I'm thinking more like 4.

    • @BackyardMaine
      @BackyardMaine  4 місяці тому

      The manufacturers rate the devices to trip between 4-6 mA. Picking 5mA is the industry standard. If I had to choose between 4 and 6 I would choose 6 since it may not trip at 4.

  • @stevethomas5849
    @stevethomas5849 Рік тому

    IET Wiring Regulations 18 th Edition
    Chapter 41 411.1 where specified, additional protection is provided by an RCD with rated residual operating current not exceeding 30mA, in accordance with Regulation 415.1.
    That's how is it in our Wiring Regulations. Same science, different voltage and amps.

    • @BackyardMaine
      @BackyardMaine  Рік тому

      Yes it's a bit different. I think the reason for the higher 30mA is because you run 220v to ground which will nuisance anything less than 20mA. We have SPGFCI breakers for voltages greater than 150v to ground which trip at 20mA.

    • @stevethomas5849
      @stevethomas5849 Рік тому

      @@BackyardMaine
      Since the 18th Edition Amendment 2: 2022 was introduced. All new domestic installation have to have Surge Protection (SPD). Also property's that are Care Homes , Student Accomodation and Hotels need AFDDs (Arc Fault Detector Device) on all circuits. So, now the circuit is protected from over current by circuit breaker, earth fault by RCD, Surge current by SPD and finally Arc Faults by AFDD. Come a long way from a simple re-wireable Fuse that your Dad re-wire if it had blown. Only socket outlets and light fittings are permitted by non skilled person (electrically) since 2005. No tinkering with Fuse Box anymore for Dad.

  • @richroc7
    @richroc7 5 місяців тому

    My apartment was shut down by code for no heat or hot water but we also were living there for 5 years with everything in the three bedroom apartment hooked up to only TWO circuit breakers 20 amps each and our oven was not on gfci.

    • @BackyardMaine
      @BackyardMaine  5 місяців тому

      Old or existing installations are not required to upgrade to current standards unless new work is being done.

    • @richroc7
      @richroc7 5 місяців тому

      @@BackyardMaine oh, it’s not even about upgrading to newer standards it’s about that was completely out of code to begin with to have a three bedroom apartment running off two circuit breakers that are 20 A each. There’s no way that that can be right you know what I mean

    • @BackyardMaine
      @BackyardMaine  5 місяців тому

      @@richroc7 Unless it was built 70 years ago or more.

    • @richroc7
      @richroc7 5 місяців тому

      @@BackyardMaine you’re saying that it’s legal to remove all the wires from all the other 14 circuit breakers and hook them up to the last two in the panel and rent the apartment to a family of 6? It has nothing to do with being old, the electrical was redone in the nineties but when the circuit breakers broke because they were 30 years old they just moved the wires to a breaker that worked instead of replacing the breaker. Do you understand now? It’s also against the law to remove the main breaker while the family is living there and that’s what my landlord did to my neighbor downstairs.

    • @BackyardMaine
      @BackyardMaine  5 місяців тому

      @@richroc7 No what I'm saying is it may have been code compliant when it was installed if the installation happened a very long time ago. The code is not retroactive so we are not required to make updates and the code updates over the decades. It applies to new work. There may be rules outside of the code that prevent renting an apartment when it is unsafe but it's not in the NEC. I hope this clear up any confusion.

  • @ericringsrud9398
    @ericringsrud9398 8 місяців тому

    What section of code is this GFCI change under in the 2023 NFPA 70?

    • @BackyardMaine
      @BackyardMaine  8 місяців тому

      (210.8 A-F) GFCI Protection for Personnel. (210.13) (230.95) GFCI Protection for Equipment. Other Articles for GFCI and SPGFCI are scattered throughout the code. (410.184) (680.5) (680.44) (690.41) probably a few more I can't remember.

  • @VideoByPatrick
    @VideoByPatrick Місяць тому

    Another youtuber says don't use Load terminals to next outlet as next outlet will still be hot despite gfi tripping ! Is that true ?

    • @BackyardMaine
      @BackyardMaine  Місяць тому

      No, if you use the load terminal to feed other receptacles and the GFCI trips, those receptacle will lose power. That's the whole point, all receptacle connected to the load side terminal will be GFCI protected.

    • @VideoByPatrick
      @VideoByPatrick Місяць тому

      @BackyardMaine the other youtube meant if 2nd receptical is gfi it won't ttip.

    • @BackyardMaine
      @BackyardMaine  Місяць тому

      You can actually even use a gfci down stream of another gfci and it will work but there is nothing gained by wiring them that way.

    • @VideoByPatrick
      @VideoByPatrick Місяць тому

      @BackyardMaine I've learned that when stringing 3 gfi on same branch leg I couldn't use LOAD as that would be serial; I needed parallel so if one gfi tripped, all three gfi would trip.

  • @ranger178
    @ranger178 5 місяців тому

    i thought they had an exception for dedicated refrigerator outlets so you don't lose all the contents of refrigerator from a nuisance trip.
    my neighbor redid their kitchen and the inspector wanted gfci breakers not outlets in the kitchen why is he asking for that is that in new code is the breaker better than the outlet?

    • @BackyardMaine
      @BackyardMaine  5 місяців тому +1

      The refrigerator on GFCI is new in 2023. I don't like it either and i'm sure a lot of people are going to be changing them out after inspection.

  • @jhill4874
    @jhill4874 Рік тому +1

    Is this new construction or retroactive?

    • @BackyardMaine
      @BackyardMaine  Рік тому +1

      New construction or if you renovate and pull a permit. Also depends on which year code you state and county have adopted. Some states are several code cycles behind.

  • @carlseiler6441
    @carlseiler6441 Рік тому

    I was hoping he was going to explain HOW they work. I get it that when there is an imbalance they trip, but how does the device actually detect the imbalance.

    • @BackyardMaine
      @BackyardMaine  Рік тому +5

      The GFCIs use a CT (current transformer) to monitor the hot and neutral together which will detect zero amps during normal operation. The CT is monitored by an IC board (integrated circuit board) and when it detects ~5mA or more the IC opens a relay which trips the GFCI which interrupts the flow of current to the fault. I hope this helps.

    • @carlseiler6441
      @carlseiler6441 Рік тому

      @@BackyardMaine thanks. IC board makes sense. Wonder if that’s how they were making them back in 1975.

  • @KBQuick81
    @KBQuick81 6 місяців тому

    Darn, I need to install GFCI throughout the entire kitchen

    • @BackyardMaine
      @BackyardMaine  6 місяців тому

      You don’t need to change existing wiring. That’s for new installations

  • @rafalfediuk505
    @rafalfediuk505 3 місяці тому

    ..so I'll have a heart attack before a light bulp turns on?. Very interesting 😁

  • @ReasonablySane
    @ReasonablySane 6 місяців тому +2

    They were forced to put a few of these in my new shop building in order to get power hooked up. Even though the building has no water. The problem is that on a 15 amp breaker, about 80% of the time my saw will trip the GFCI when it starts up, even though it is less than 15 amps. The real problem is that when my wife and I were out of town for a week there was an interruption in our power and, though the power came back on, All of the GFCI outlets tripped, and two of them were connected to a freezer. We lost a lot of food.
    My solution: Removed and replaced with normal outlets. Problems solved. I'll live - probably. Our outlets are as safe as they were when I was in high school (early 70's). And we built our own home at that time. i.e. it has no GFCI outlets and nobody has died yet.😁
    The ones in our home trip from time to time, but that's not really a problem because they are not on the circuit attached to our refer, and we don't plug any high power appliances. Not worth the hassle of replacing them. They are simply not acceptable in the shop building.

    • @BackyardMaine
      @BackyardMaine  6 місяців тому +1

      I hear you. We want to be safe but we need the circuits to work. Power surges can damage a GFCI since they do have electronics. One of the reasons why surge suppressors are now required by code. Power saws are inductive loads which means they have inrush each time they start. That inrush can be as high as six times the running load for a short duration. My table saw draws about 12A while cutting but will trip a 15A breaker every time it starts. I have to remember to plug it into a 20A circuit.

  • @TomCee53
    @TomCee53 11 місяців тому

    Please get it right, even though it doesn’t matter to this discussion. A 100 watt light bulb in the US draws about 800ma, not 1000.

  • @aparamon
    @aparamon 6 місяців тому +1

    Why can't we just use GFCI circuit breakers. it is much easier to upgrade them instead of all the receptacles in a house. It is also hard to find heavy dusty GFCI receptacles.

    • @BackyardMaine
      @BackyardMaine  6 місяців тому +3

      Yes, GFCI breakers are also a code compliant option. Many people prefer the point of use option for a few reasons. 1- The receptacles are more convenient to reset rather than having to go to the panel. 2- The receptacles are a whole lot cheaper than the breakers. 3- The breaker will protect the whole circuit which isn't always desirable.

    • @aparamon
      @aparamon 6 місяців тому

      Thank you for the clarification of the code.
      In some projects a large number of receptacles may need to be updated (e.g. basement). In this situation upgrade of the circuit breaker may be cheaper. A 14A receptacles is about $15-20. A circuit breaker is about $50.
      It is also hard to find heavy-duty spec of GFCI receptacles. There are hospital-grade GFCIs but they are very $$$. At the same time you can find an industrial-grade Leviton for $7-8. GFCI circuit breakers may also be an option if outlet endurance and reliability are desired by the customer.

    • @ranger178
      @ranger178 5 місяців тому

      most of the time you just put one gfi outlet in first one on that circuit and then feed rest of outlets off of that gfis output terminals so you only need to buy one GFI not every outlet@@aparamon

  • @user-kr6pn9kb6t
    @user-kr6pn9kb6t 6 місяців тому

    Хорошее видео.

  • @fjl05
    @fjl05 Рік тому +4

    A range requires GFCI? where do you even get a GFCI receptacle for a range oven?
    ANd now a refrigerator and microwave require gfci? These are devices known to trip GFCI's all the time just from regular use. this is a bad decision and I am completely against it. YOu just know electricians will comply for the inspectors then change them out after everything passes.

    • @BackyardMaine
      @BackyardMaine  Рік тому +3

      GFCI protection for the range would be installed at the panel as a breaker. I get that the GFCIs do save lives but there is also the practicality of the device to consider. I don't wind the range or even a microwave but refrigerators and freezers are a mistake in my opinion. Once people start loosing a freezer or refrigerator full of food because they didn't realize the GFCI tripped they will be changing them out.

    • @fjl05
      @fjl05 Рік тому

      @@BackyardMaine exactly. and i think the same will go with microwaves and stove/range.

    • @ryanbrown5334
      @ryanbrown5334 4 місяці тому +1

      Refrigerant compressors can trip GFCI’s on start up. AC’s and heat pumps are also required now. Homeowners are going to love paying for a service call just for a tripped gfci

  • @tchevrier
    @tchevrier 11 місяців тому +14

    the recent code changes for GFCI and AFCI are going way overboard in my opinion

    • @BackyardMaine
      @BackyardMaine  11 місяців тому +2

      I don’t disagree.

    • @jonreedau81
      @jonreedau81 10 місяців тому +6

      They are being driven by circuit breaker manufacturers looking to increase their sales of both. And trying to drive business away from receptacle manufacturers.

    • @ranger178
      @ranger178 5 місяців тому

      another fine example of government stupid overreach I will never put a refrigerator on a GFI it is ridiculous

    • @vicktorpatriot1430
      @vicktorpatriot1430 5 місяців тому +2

      I want to know how much bribe money is paid out by manufacturers to get their products, often causing loss of food , water control when it comes to Arc fault devices,

    • @SuperJhuffman
      @SuperJhuffman 3 місяці тому +1

      They are based on the number of electrocution deaths that could have been prevented. Children died because the code changes were not yet in place.

  • @rothgang
    @rothgang Місяць тому

    Jeez. Why not just make everything require GFCI from the very beginning? Why play this game of slowly requiring more and more locations to be protected?

    • @BackyardMaine
      @BackyardMaine  29 днів тому

      I get that.. Probably the end game will be everything GFCI and AFCI protected.

  • @panemon187
    @panemon187 4 місяці тому

    GFCI protection can be challenging to implement on multiwire branch circuits (MWBCs) due to the shared neutral. In a MWBC, two hot wires share a common neutral. When a GFCI monitors the current on the hot and neutral conductors, it may not accurately detect ground faults because the current on the neutral is the algebraic sum of the currents on both hot wires. I guess you could get away with using a double pole GFCI breaker for both phases.

  • @CarrieWard-ny1zl
    @CarrieWard-ny1zl 5 днів тому

    Why not make everything GFCI? I mean, geez.