you did good job but you must have changed all igbt of burnt side beacause remained igbt becomes effected and can create problem on the load so better to change all worn components
What a wonderful tutorial, I'm from Nigeria i have same hybrid inverter that is faulty i changed some components, but there two SMD at the button that i couldn't get there value uptil now. Could you assist me please?
hi, if you have this board, i need the model or de V of ZD1,ZD2,ZD7,ZD8.(botton side near of tlp 350). And the service manual if its posible. I try to repair but those components exploded.Thanks
Hello, 3000 watt solartronics full sinus inverter fault light is on. When the inverter is turned on, a relay tripping sound is heard, then the fault light is on, what do you think could be the problem?
Hello, M PS-V-3500W-PLUS arrived today, I connected only the battery, without consumers, after about 15 min it started beeping, it indicated that it would enter the 220v network and it smelled of smoke, I closed it, after 30 min I opened it, it beeped no it shows no error code, some relays are heard and it closes, it is worth repairing or trying with the warranty. But I don't think I can solve anything with DBSOLAR. Thank you
I have Ns GWI Green Energy Solar Inverter. A series of 2 * 2 solar panels of 410 watts and then parallel to them. Every morning as soon as the sun rises The inverter turns off OUTPUT and F51 appears on the screen. This fault disappears automatically after restarting the inverter. Then all day this inverter works properly. The same fault again the next morning.
Bhai mere pass fox ess h1-6.0-e hybrid inverter he Osme battery voltage range 85-450vdc he Magar bhul se mene 48v ki battery 10kw storage ki kharidi Magar mere pass inverter capacity 85voltage Inverter ki battery capacity 85 se 48 kar skate he
bhai apne bata hu bohat acha magar testing k doran apke hath ki waja se kuch nazar ni aya k apne kia kia check kiya kam az kam bol kar bata diya kare k kiya kiya kar rahe hain
you did good job but you must have changed all igbt of burnt side beacause remained igbt becomes effected and can create problem on the load so better to change all worn components
Dapat bossing nilagyan mo nang panibagong silicon compound o grease para intact ang heat transfer ng transistors.
Good tiching karte hai 👍👌👍👍👌👌👍
Very nice Sir 👍
vedio k sta voice ka hnoa zarore hy
zabardasat
Hi, do you perhaps know what is the value of D8 diode?
What a wonderful tutorial, I'm from Nigeria i have same hybrid inverter that is faulty i changed some components, but there two SMD at the button that i couldn't get there value uptil now.
Could you assist me please?
Yes
very good
Nice sir
Ap ne Kam acha kiya but bol k Bataya kuch ni agr ap apni voice batate b rhete to or achi video hojati 👍
hi, if you have this board, i need the model or de V of ZD1,ZD2,ZD7,ZD8.(botton side near of tlp 350). And the service manual if its posible. I try to repair but those components exploded.Thanks
Vey nice
The manual actually explains all the errors displayed on the screen. With it, you know where the issue is coming from
Hello, 3000 watt solartronics full sinus inverter fault light is on. When the inverter is turned on, a relay tripping sound is heard, then the fault light is on, what do you think could be the problem?
Assalam u alaikum
irfb4127 ki jaga konsa fet chal jaye ga
Hello, M PS-V-3500W-PLUS arrived today, I connected only the battery, without consumers, after about 15 min it started beeping, it indicated that it would enter the 220v network and it smelled of smoke, I closed it, after 30 min I opened it, it beeped no it shows no error code, some relays are heard and it closes, it is worth repairing or trying with the warranty. But I don't think I can solve anything with DBSOLAR. Thank you
Assalam o alaikum
Kia ap bta skty hain k ic fault k any ki waja kia hai?
I have Ns GWI Green Energy Solar Inverter. A series of 2 * 2 solar panels of 410 watts and then parallel to them. Every morning as soon as the sun rises The inverter turns off OUTPUT and F51 appears on the screen. This fault disappears automatically after restarting the inverter. Then all day this inverter works properly. The same fault again the next morning.
over current or surge fault
WhatsApp 03024105803
hello, any solution for pv18 3024 with error code 74 and 33
Is there any pdf or video that shows general steps in repairing and testing inverters for faults
Not yet
Hi anyone know the reason when battery breaker for hybrid inverter keep tripping
Repairing without explaining?
easy-peasy
Bahi Jan is Yi Wala board mil jay ga aur kitnay ka hay mehrbani karna bata den
kon sa board
Bhai mere pass fox ess h1-6.0-e hybrid inverter he
Osme battery voltage range 85-450vdc he
Magar bhul se mene 48v ki battery 10kw storage ki kharidi
Magar mere pass inverter capacity 85voltage
Inverter ki battery capacity 85 se 48 kar skate he
5kw homage inverter dc booster section
bhai apne bata hu bohat acha magar testing k doran apke hath ki waja se kuch nazar ni aya k apne kia kia check kiya kam az kam bol kar bata diya kare k kiya kiya kar rahe hain
ok
App ka shop kaha pr he
lahore
sir , yeh konsa model hy , aur tesla ka konsa model sabse best hy?
ye vm2 h
Hello po. E06 din po error ng sakin.
Anybody there near Kolkata/Bardhaman who can repair Su kam 5KV PCU ?
not know
@@hightechups6705 Nobody ? Tata Power Solar is not ready help consumer of other company.
Please who can tell the cause of code 53 in 5kva hybrid inverter
inverter soft start failed
@@hightechups6705 what's the remedy?
hi did u find out the remedy for code 53
সোলার ইনভার্ট ননস্টপ হলে করণীয় কি
I have 3000kw doing same error 06 please what can i i do help me out thanks
FET check kary
output is to high
@@hightechups6705 what next to check on it thanks
@@leeone7822 WhatsApp 0923024105803
looks like its now showing error 01