VFD GT series operation

Поділитися
Вставка
  • Опубліковано 11 гру 2024

КОМЕНТАРІ • 109

  • @martyscncgarage5275
    @martyscncgarage5275 6 років тому +7

    Show demonstration with BRAKING resistor on GT series and fast decelleration to stop on 5hp motor. How fast can you stop without faulting the VFD

    • @traunicht1872
      @traunicht1872 3 роки тому

      hello, someone has seen a similar video, or with DC braking

  • @maxlevesque
    @maxlevesque Рік тому

    At 9.18m the video says "contact customer service" for break resistor when ordering... The problem is Amazon provides no way of contacting HuanYang, or any othe seller for that matter.

  • @josepastorjimenez
    @josepastorjimenez 2 роки тому

    best regards friend. Excuse me, I have a Haunyang frequency variator, it would be GT, that has the keyboard locked and does not let me change anything. the control light with external keyboard flashes. Do you know how the variator is respected to reset everything to the factory?

    • @huanyanginverter6516
      @huanyanginverter6516  2 роки тому

      There is no way to replace the motherboard. .
      It can only be solved in the factory

  • @BackTheTooFuture
    @BackTheTooFuture 7 місяців тому

    Can you tell me what amps are needed for the 220V input on GT-7R5G-2?

  • @MarshallDudley
    @MarshallDudley 2 роки тому

    The video says to connect single phase power to R and T terminals. The Q and A on Amazon for this controller says to attach to R and S. Which is it?

  • @steveu235
    @steveu235 4 роки тому

    Just finished the wiring it was easy thanks for making this video

  • @kylerf150
    @kylerf150 8 місяців тому

    Hello, i have a gt series running a 7.5hp motor. I have a switch sends 220v to the vfd. Can I wire s1 and com together (connected all the time). That way when the vfd gets 220v it runs immediately after it boots up?

  • @philjacobus5715
    @philjacobus5715 3 роки тому

    Just received myn1.5 kw water cooled dpindle. Inhavtbyo star the programming over so let’s see if I can do it. One thing noticed is a lot of vibration when the spindle is running. Should I be concerned?

  • @Elchapo62
    @Elchapo62 Рік тому

    Your manual very confusing, P2.01- I have a 2.2 KW motor, the setting range is 0.4-3000 for motor rated power, can you tell me what to enter . Also how do I change the frequency read out to RPM, I try the shift key doesn't work is the another key i have to enter?

  • @Elchapo62
    @Elchapo62 Рік тому

    Can you do a video on 485 communication with GT series VFD.

  • @AdamRhoads
    @AdamRhoads 7 місяців тому

    I have the 7.5kW VFD GT series. When i turn the power on to the VFD it displays 330V instead of the 230 I have at the input. I verified the input voltage to be correct with a multimeter. Is there a setting to change this?

    • @huanyanginverter6516
      @huanyanginverter6516  7 місяців тому

      SHIFT

    • @AdamRhoads
      @AdamRhoads 7 місяців тому

      I understand that the shift button cycles between options to display. When the LED for V is illuminated it reads 357. Should this be displaying 220 input voltage instead?

    • @huanyanginverter6516
      @huanyanginverter6516  7 місяців тому

      @@AdamRhoads Yes, the display shows DC voltage.

    • @huanyanginverter6516
      @huanyanginverter6516  7 місяців тому

      @@AdamRhoads yes

    • @huanyanginverter6516
      @huanyanginverter6516  7 місяців тому

      @@AdamRhoads The displayed voltage is a bit high

  • @ВадимАфанасьев-ю7е

    Hello. How to connect 3-wire( multe-speed ) control. What inverter settings need to be done? I can't figure it out. Thanks.

  • @aticafloorable
    @aticafloorable 4 роки тому

    What parameters should I set for when the engine is running, the screen will only show me the revolutions. Thank you

  • @aticafloorable
    @aticafloorable 9 місяців тому

    sr the frequency in use is 60 HZ AND THE FREQUENCY OF MY MOTOR IS 50 HZ. THE PARAMETERS P0.03 60HZ, PO.O4 60HZ, P0.06 60HZ, AND FOR THE MOTOR P2.02 50HZ Is this correct? thank you

  • @ruzannasahakyan
    @ruzannasahakyan 9 місяців тому

    Hello. Please tell me how to connect and configure the NC Studio program with HY HUANYANG ‎GT-7R5G-2

    • @huanyanginverter6516
      @huanyanginverter6516  9 місяців тому

      This scope is too broad, you need to go into specific details. What functions are achieved. Draw a sketch for me.

  • @jonoanderson8025
    @jonoanderson8025 Рік тому +1

    I have huanyang gt 4kw 220v 1ph in 3ph out running 230v 3ph induction motor 50hz 2.2kw 3hp 2800rpm 8.7A. I set motor parameters p2.01,02,03,04,05 as motor name plate. And settings hz p0.03=50hz p0.04=50hz p0.05=0hz p0.06=50hz p0.07=1 then auto run auto tune no problem. Then motor works in v/f mode but when switch to vector control motor makes noise and wont spin. I want to run in vector mode for low speed torque and control speed through control pad potentiometer can you help me please.

  • @SanjivMaheshwari
    @SanjivMaheshwari 4 роки тому

    Sir, can be use solar dc as input and get single and triple phase at the same time / different time to run two motors.

  • @elroyjames8623
    @elroyjames8623 3 роки тому

    Hello I have a GT -7RSG~2
    Running a 7.5hp 3 ph motor on a small block machine for vibrating the shaft and operating the pump
    However once I apply the load by activating the vibration the vfd keeps chipping...with error code oc1 and sometimes OH1

  • @Elchapo62
    @Elchapo62 Рік тому

    Can you make a diagram on jumpers setting using 485.

  • @marabunsewq4623
    @marabunsewq4623 3 роки тому

    what current external start/stop button do i need for 5,5 hp motor.
    Is it ok with small current button?

    • @huanyanginverter6516
      @huanyanginverter6516  3 роки тому

      Yes, no need to consider current

    • @traunicht1872
      @traunicht1872 3 роки тому

      @@huanyanginverter6516 how to brake the engine by injecting alternating current?

    • @huanyanginverter6516
      @huanyanginverter6516  3 роки тому

      @@traunicht1872 ua-cam.com/video/yt2YEVnULDE/v-deo.html

  • @Elchapo62
    @Elchapo62 2 роки тому

    can I use a GT series VFD to control a 24 K rpm cnc spindle ?

  • @steveu235
    @steveu235 4 роки тому

    Do all the gt series have the same program parameters and terminal for run jog stop etc.and also for using an external Potentiometer?

  • @briang7298
    @briang7298 4 роки тому

    I have other inverters but cannot get this one to output power to motor even tho the inverter seems to be running. Please help.

  • @jjww9151
    @jjww9151 4 роки тому

    external potentiometer is shown connected to GND,AI2 and ACM but instructions say 10v,AI2 and ACM --- WHICH IS IT?

  • @MarkThomas123
    @MarkThomas123 6 років тому

    Where can I download the Manuals for the HY01D511B-T 110V In 1.5KW and GT-2R2G-2 220V In 2.2KW? Interested in both..
    I think the programming has different numbers for parameters? HY01D511B-T does not come in a Vector version?

    • @huanyanginverter6516
      @huanyanginverter6516  6 років тому

      Where can I download the Manuals for the HY01D511B-T 110V In 1.5KW and GT-2R2G-2 220V In 2.2KW? Interested in both..
      I think the programming has different numbers for parameters? HY01D511B-T does not come in a Vector version?

  • @aticafloorable
    @aticafloorable 2 роки тому

    could you please make a video illustrating the same thing but with a 5.5 kW 7.5 HP 220 V

    • @huanyanginverter6516
      @huanyanginverter6516  2 роки тому

      What problem are you having?

    • @aticafloorable
      @aticafloorable 2 роки тому

      @@huanyanginverter6516 Mr. I want to buy. the model 5.5 kW 7.5 HP 220 V AC 25 A I want to know if the configuration and the terminals are the same as the model 4 kw 5 Hp. I bought a 4 Kw and your video helped me to program lpsandos remotely now I want to buy a 5 Kw and I want to know if your video will also help me with this. Thank you

  • @Dragon90815a
    @Dragon90815a 3 роки тому

    Do you have a manual for all of these codes and functions?

  • @JeffLiebermann
    @JeffLiebermann 6 років тому

    The video says:
    "Note: Contactor or switch is forbidden to be installed between inverter's U,V,W terminals and motor".
    Why? Does the VFD require a permanent load? What happens if I run it without a motor or load attached?

    • @huanyanginverter6516
      @huanyanginverter6516  6 років тому +1

      When the frequency converter is running, suddenly the motor is disconnected, which will lead to the damage of the frequency converter.

  • @aticafloorable
    @aticafloorable 4 роки тому

    Mr my motor is 3 KW. 4 HP. 11.8 / 6.8 A. 1400 RPM. 50 HZ. 220/380 V. IT IS FROM A CEMENT POLISHING MACHINE THAT I MUST SET PARAMETERS. THANKS. THE MODEL IS THE SAME FROM THE VIDEO

  • @Hackjob-Extraordinaire
    @Hackjob-Extraordinaire 2 роки тому

    hello, i cant get my motor to run!!
    inverter model gt 5r5g 2 with 220v 3 phase motor 5hp 1725rpm

  • @stuartflys
    @stuartflys 4 роки тому

    Hi, what size potentiometer would you recommend?

  • @fahimasghar6375
    @fahimasghar6375 5 років тому

    Very nice video Sir. Thanks

  • @ZOREDA100
    @ZOREDA100 4 роки тому

    Thanks 👍🏼really helpme

  • @steveu235
    @steveu235 4 роки тому

    I Have 2 jog buttons one reverse one forward the default frequency is 5 where can i Change this.Thanks

    • @huanyanginverter6516
      @huanyanginverter6516  4 роки тому

      You change the forward and reverse parameters in the, video.

    • @steveu235
      @steveu235 4 роки тому

      @@huanyanginverter6516 I found it in the book thanks

  • @Crestone-saju
    @Crestone-saju 5 років тому

    How do you change motor pole and motor speed "rpm"?
    Thank you

  • @elshantagiyev
    @elshantagiyev 4 роки тому

    Hello everyone, please help me. I have connected VFD GT 2.2kw between NOVUSUN NVEM v2 + mach 3 controller.
    But I am having a problem I cannot adjust the spindle speed for match3. When enabled through match 3, the speed increases to the maximum. Help how to connect correctly

    • @huanyanginverter6516
      @huanyanginverter6516  4 роки тому

      Your question cannot be answered in a few sentences. . . You have to provide drawings of MACH3. . You need to set the functions of these terminals S1, S2, S3, and S4.

  • @steveu235
    @steveu235 4 роки тому

    I have flashing red lights what causes this I see nothing in the book about the flashing leds

    • @steveu235
      @steveu235 4 роки тому

      Found the problem the com and the 10v of potentiometer have to be connected at the right place cant be interchanged

    • @huanyanginverter6516
      @huanyanginverter6516  4 роки тому

      Excuse me, which specification do you buy?

    • @huanyanginverter6516
      @huanyanginverter6516  4 роки тому

      Which country

  • @renosgarage7451
    @renosgarage7451 5 років тому

    Very helpful thank you

  • @Phantom-mk4kp
    @Phantom-mk4kp 6 років тому

    i
    Hi I have a 220v 7.5 KW GT version where can i download a manual Thanks

  • @pomonabill220
    @pomonabill220 Рік тому

    Nice video.. couldn't stand the tinkly music though!!!!!!

  • @khurramshaikh4347
    @khurramshaikh4347 3 роки тому

    Vfd setting save not saved please help

    • @huanyanginverter6516
      @huanyanginverter6516  3 роки тому

      Can't understand what you mean, you sent it to me in a video. Email:xwdnzyp@163.com

  • @cache3738
    @cache3738 4 роки тому

    Just like you said, i leave a message here.
    Here is my problem with the inverter
    ua-cam.com/video/FIC34LxeqOM/v-deo.html
    The UP button is not working.

  • @jeffreyehrens4843
    @jeffreyehrens4843 4 роки тому

    How the heck do you simply change from 50HZ to 60 HZ. This is so basic and info unobtainable
    Huge PITA for something so basic . Read the manual 1 0x and useless for me
    Frustrating

  • @Johnchew7
    @Johnchew7 4 роки тому

    如何connect mach3 ethernet card 2? hewgant86@gmail.com