  • Опубліковано 29 тра 2023
  • HMH7 Heat Pump New Construction wiring and charging tips
    • HMH7 Heat Pump New Con...
    HMH7 Installation and Testing Video
    • HMH7 Modulating Heat P...
    How to rough in a Mini split in new construction house?
    • How to rough in a Mini...
    How to heat and cool a barn dominium?
    • How to heat and cool a...
    Foam Insulation Verses Standard Insulation
    • Spray Foam Insulation ...
    Wanna Learn more about hvac? Check out my hvac tips for technicians playlist.
    • HVAC Tips for Technicians
    Click JOIN and become a member
    / @taddydigest
    ‪@samsunghvacAmerica‬ ‪@YorkHomeComfort‬

КОМЕНТАРІ • 56

  • @braydon44884
    @braydon44884 21 день тому +1

    This looks like a sick install

  • @kennethbubser9601
    @kennethbubser9601 Рік тому +3

    Great job. Spiral pipe always look great. Could not tell if spiral or regular round pipe. But looks good. I always do returns in every room but kitchen, closet, bathroom. But I get it. Whatever in the budget. Hate when people say negative shit about a job on UA-cam without knowing budget.

  • @AaronPowellvox
    @AaronPowellvox Рік тому +3

    What is the point of those rough in mini-split boxes when the copper doesn’t line up right when you go to install the head? I’ve seen guys have to go and put those RLS couplings on there and just cut out the flare joints. Just curious. Can they be installed where you can just use the fare joints with some proper planning?

  • @kennethbubser9601
    @kennethbubser9601 Рік тому +1

    But nice clean work. In New Jersey we have to hard pipe or flex every return. We can’t draw bays or have any wood. Every job has to have load calcs. Duct test for leakage. We got to be painters on top of every other thing we Hvac guys do. Mastic all connections even flex to boot. Miss how we did 30 years ago. Lucky if we taped a joint

  • @PaulHVAC1
    @PaulHVAC1 Рік тому +1

    Thanks Tad I enjoyed it. Keep up the good work Cheers from 🇨🇦

  • @USA-GreedyMenOfNoIntegrity
    @USA-GreedyMenOfNoIntegrity Рік тому +8

    I stopped doing new construction 13 yrs ago. Once you find out where your profits and time are worth more you’ll avoid builders too.

    • @brooksparadis2230
      @brooksparadis2230 Рік тому +1

      Exactly, more money in installing mini splits, service and replacing condensers/air handlers and furnaces

  • @steveoh9838
    @steveoh9838 Рік тому +2

    Looks good. I would shorten and throw some 90's on them exterior condensate lines. There are gonna get knocked at some point.👍

  • @Seedavis397
    @Seedavis397 Рік тому +2

    Do you angle your 3 way supply grilles toward in our out of home??? It looked like they were feeding inward I’ve always done the opposite is there a reason for that?

  • @titolopez4270
    @titolopez4270 Рік тому +2

    Great video!
    I am starting in hvac in Arizona, I learned from your video return size vent should be 200 Sq inch per ton

    • @TaddyDigest
      @TaddyDigest  Рік тому +1

      That is awesome!
      Glad I could help my friend

  • @mervyncorrales2876
    @mervyncorrales2876 4 дні тому +1

    What’s the best software to use to bid an hvac system from a blueprint?

    • @TaddyDigest
      @TaddyDigest  4 дні тому

      That's a good question I have run across a couple of different softwares, but i'm not sure who I would recommend.Let me do some digging

  • @nazmulhassan5283
    @nazmulhassan5283 Рік тому +1

    Boss . Mitsubishi AC . light bilking 14 time . not working Indoor fan. this it problem gas r32 .after giving . same problem. now gas ok . but not working . flash light continue . please reply?

  • @Metalamigo1984
    @Metalamigo1984 8 місяців тому +1

    Nice work bro keep pushing 💪

  • @amithimani8163
    @amithimani8163 Рік тому +1

    Hey Taddy, I love your Videos. I also Have an HMH7 4 ton unit Installed with two Zones. I am curious to know why did you Wwre the thermostate for HMH7 Y and Y2? HMH7 is a modulating unit and it does not have a 2 stage it have several stages and the out side unit (HMH7) controlles the stages depending on the call? Can you please Explain. Also in your other videos you have not wired the thermosates for HMH7 the way you did it in this video.

  • @Dread-pg6sr
    @Dread-pg6sr 8 місяців тому +1

    What size wire do you use for the air handler?

  • @amithimani8163
    @amithimani8163 Рік тому +1

    In this install, you wired the thermostat differently than you did in your previous video for the MHM7 just wondering why?

  • @joshuaseaton4526
    @joshuaseaton4526 Рік тому +1

    Oh, and why the big trim plates for the MHK2 thermostats? Shouldn't need them on new construction.

  • @williamgildea8348
    @williamgildea8348 Рік тому +2

    Love your videos. Why didn’t you use spiral duct in the open space, might of looked a little nicer.
    Surge protection on the mini split?

  • @billyrivere6664
    @billyrivere6664 Рік тому +1

    Thanks so much for the info!

  • @kennypuri7399
    @kennypuri7399 Рік тому +1

    Hey Taddy, can you do a video on lightstat thermostat, it’s been a painful process for me to try and troubleshoot these, would greatly appreciate it

    • @TaddyDigest
      @TaddyDigest  Рік тому +1

      I'm not familiar I will check into that yes I can do a video

  • @MrtoSammy
    @MrtoSammy Рік тому +1

    Can you please make some videos about conversion to LP for different brands furnaces

  • @michaelfassino4314
    @michaelfassino4314 Рік тому +1

    Are you returning air from each room or just the return plenum ?

  • @Hvacnc
    @Hvacnc Рік тому +1

    Nice video

  • @DiegoMoncada-be6gn
    @DiegoMoncada-be6gn Рік тому +1

    Hey Tan, do you vacuum each head on the multi zone !? Thanks in advance 🙏

    • @TaddyDigest
      @TaddyDigest  Рік тому +1

      The ports that you use to vacuum
      They are connected To all the indoor heads.
      So yes you vacuum them at the same time

    • @DiegoMoncada-be6gn
      @DiegoMoncada-be6gn Рік тому +1

      Is there a tool to evacuate 3 heads at the same time that you may recommend I appreciate it Taddy
      I will become a member for sure, for your quick response 👍

    • @TaddyDigest
      @TaddyDigest  Рік тому

      You do not have to have a special tool
      I think I have a video on it
      I will try to find it

  • @2SmoothV
    @2SmoothV 10 місяців тому +1

    Hey i'm looking into going into hvac school mainly to learn how to do this for construction purposes. Do they teach this type of infomation at school, or is this something you learn working with other people.

    • @TaddyDigest
      @TaddyDigest  10 місяців тому

      They definitely do not teach this in school
      I have a Bunch Of courses that you can have access to by becoming a level three member.
      Definitely check out my member's only courses

    • @2SmoothV
      @2SmoothV 10 місяців тому +2

      Interested. What would be the pipleine in order to do this? Would I need schooling for this? what type of certifications from the state?
      @@TaddyDigest

    • @TaddyDigest
      @TaddyDigest  10 місяців тому

      I have my electrician license so I can pull a electrical Permit
      I have my general mechanical contractor license so I can pull in mechanical permit.
      But I only have to use that one for commercial

  • @michaelfassino4314
    @michaelfassino4314 Рік тому +1

    Noisy return also ?

  • @michaelgonzales803
    @michaelgonzales803 Рік тому +1

    I see you mentioned 200 sq in per ton on return ... is that a minimum or is there a such thing as "Too Much return air"? Thank you for the great videos.

    • @TaddyDigest
      @TaddyDigest  Рік тому

      There is never such a thing as too much return
      You can never have too much return
      Give me more return please

    • @michaelgonzales803
      @michaelgonzales803 Рік тому +1

      @Taddy Digest thank you for the quick reply... yeah that's what I was thinking. I m thinking of adding returns to my rooms.

  • @potentialhvac6074
    @potentialhvac6074 Рік тому +1

    Props to you on making another great video. Great demo. Does your two ton mini split have a greater capacity than 24k? Because 9k plus 18k is 27k and usually id have my indoor units equal outdoor capacity or less...

    • @TaddyDigest
      @TaddyDigest  Рік тому

      Thanks brother
      The two ton will do thirty percent more than its capacity

    • @potentialhvac6074
      @potentialhvac6074 Рік тому +1

      Aaw I suspected something like that. Learned something new, exactly why I watch your channel. Now i wonder if that varies umoung different brands. Recently watched the shoptalk show and learned that you have dedicated training videos. I swear ima hit that join button sooner than later lol. I work in Northern California San Francisco/North of SF.

    • @tonyedwards9972
      @tonyedwards9972 Рік тому +1

      @@TaddyDigest I've never seen the units set like that, in a closet like that we box in the bottom section of the closet 32-34 inches high and set unit on top, using the bottom for return... and frame like you did for return grill.

    • @tonyedwards9972
      @tonyedwards9972 Рік тому

      @@TaddyDigest looks good though

  • @joshuaseaton4526
    @joshuaseaton4526 Рік тому +1

    Code here is to have the nail plate or metal extend 3 inches top and bottom of the top plate. Those guys aren't always accurate with their screws and nails, lol.

  • @NoorRefrigerationsystem
    @NoorRefrigerationsystem Рік тому +1

  • @dporrasxtremeLS3
    @dporrasxtremeLS3 Рік тому +1

    Seems Like a Great mower before the burndown... Too Bad.

    • @TaddyDigest
      @TaddyDigest  Рік тому

      lol 😆

    • @cashonlyj3469
      @cashonlyj3469 Рік тому

      You make me want to get a haircut 😅 nice video Taddy Poppins.

  • @tonyedwards9972
    @tonyedwards9972 Рік тому +1

    Hey taddy, will you be building a shelf in side the closet?

  • @tonyedwards9972
    @tonyedwards9972 Рік тому +1

    If your try ing to push that air, why not use a small ceiling fan/light in hallway area