11Kw pool heater wiring and installation coasts 220v 240v connecting to electric panel box

Поділитися
Вставка
  • Опубліковано 18 лис 2024
  • 11Kw pool heater wiring and installation coasts 220v 240v electric panel

КОМЕНТАРІ • 105

  • @stacyspooner3572
    @stacyspooner3572 2 роки тому +4

    Did you use enough PTFE?

  • @ericwood8745
    @ericwood8745 3 роки тому +5

    I’m seeing a lot of questions about wire sizing. The unit runs at 11000 watts and runs at 240v. To calculate your amps divide 11000/240. This comes to roughly 45 amps which is why they suggest 50 amps. So you’ll need a 50 amp 2 pole breaker for your panel. Nec 310.16 says the wire must be sized at #8 copper at 75 degrees Celsius.

    • @Glasswithattitude
      @Glasswithattitude 3 роки тому

      that my worry

    • @worthington5687
      @worthington5687 2 роки тому +1

      @@Glasswithattitude Check the tables then go at least one size heavier. I used #6, - it called for #8.
      Those who need to save money should first _carefully determine the correct wire to use_ , buy it, run it, then call an electrician to inspect/connect it.

    • @lawrencecohen9715
      @lawrencecohen9715 2 роки тому

      @@worthington5687 How is it working? I purchased one but didn’t install it yet. I’m worried about installing a 220V #6 and 50A… that’s a lot of juice!

    • @worthington5687
      @worthington5687 2 роки тому

      @@lawrencecohen9715 You're smart to be concerned. 220v can be scary. If you've never done that work before and are really nervous about it I recommend consulting an electrician.
      Anyway, I think I broke my unit, I'm still looking for parts as it's out of warranty.

  • @brianmcknight2599
    @brianmcknight2599 Рік тому

    How does the green light come on? How does it detect the pump?

    • @petermokry8020
      @petermokry8020 Рік тому

      The green light is part of an optional circulation pump control. For that you need a second relay and refer to wiring diagram 4 of the 2021.01.06 manual.

  • @VikingsFan27
    @VikingsFan27 4 роки тому +14

    Is this video from the company? If so how have they not been sued right out of business with this installation video? I mean from the start with the teflon tape to the end with the backyard wiring of a 240v system there wasn't anything that I saw that was to code or safe. To all of you DIY'ers out there looking to install this heater, please do not use this video as a guide on how to do it. You will likely electrocute yourself or your family.

    • @vinbia
      @vinbia 3 роки тому +2

      Seriously. This needs to be at the top of comments.

    • @worthington5687
      @worthington5687 2 роки тому +3

      He used about 5X too much teflon tape. His electrical skills will put someone 6-feet-under someday.

    • @petermokry8020
      @petermokry8020 Рік тому

      Also of concern, the unit is rated as 2 phase, 240V at 50A. From the looks of it, they are running all 50A that should go through two wires, only going through one wire.

    • @thenathanielhardyproject8675
      @thenathanielhardyproject8675 7 місяців тому

      Agreed! Also you should not have a valve installed on the “OUTLET” of a water heater!

  • @DonDiegoHS
    @DonDiegoHS 2 роки тому

    Can i do install directly to the pool? I mean I don’t like to touch original pool tube installed. Does the heater got a pump?

  • @soulsforchristdeliverancec5419

    Need help, I have the 5.5kw unit power is getting to unit water is flowing to and inside heater, but heater light not coming on and temp stays at 66 degrees, can you help me

  • @cornelhughes6763
    @cornelhughes6763 3 роки тому

    Need some help in regards to whether and how to remotely (preferably wirelessly but even wired is accepted) start and stop this heater. Also how to control the temperature remotely(wired or wirelessly)

  • @goran8958
    @goran8958 2 роки тому

    Hi can you tell me about another codes like HC

  • @eliocosaro360
    @eliocosaro360 3 роки тому +2

    What pump does this machine need?

    • @donesramon1
      @donesramon1 2 роки тому

      You know how mutch HP machine need?

    • @worthington5687
      @worthington5687 2 роки тому

      Any Hayward 1.5HP is prolly good.

  • @willitan69
    @willitan69 4 роки тому +1

    Hi ! Maybe you can help me with a electric problem.
    I have a 240v coetas pool heater end I have not been able to connect it. The water heater has 4 wires (3 red and one blue) I red, II red, III red and blue, and from the circuit breaker (black, red and white. The red and green light in the unit don’t turn on . Thank you

    • @gonzo357567
      @gonzo357567 4 роки тому +1

      I just bought one too, did you ever figure out on how its wired?

    • @domenic2049
      @domenic2049 3 роки тому +1

      I just bought one too, did you ever figure out on how its wired?

    • @chonkiras
      @chonkiras 3 роки тому

      Just splice L1 and L2 to one phase then L3 and N to the other phase.

    • @Glasswithattitude
      @Glasswithattitude 3 роки тому

      you need 3 Phase electrical like industrial most houses are single phase

    • @blkcivic00
      @blkcivic00 2 роки тому

      @@chonkiras do have pictures of this.
      I am having so much trouble

  • @danieltiscareno7656
    @danieltiscareno7656 2 роки тому

    Can you help me, I just install one of 15kw, the machine starts, but I cannot get that the heating button works, there are some with the same problem? Could be the flow rate? The machine only reads the temperature but does not heat, please help me

    • @bottseo
      @bottseo 2 роки тому

      Were you able to solve?

    • @worthington5687
      @worthington5687 2 роки тому

      Hold down the button and it should display the flow rate.

    • @AlbertoSanchez-jo5og
      @AlbertoSanchez-jo5og 14 днів тому

      ​@@worthington5687cuál botón amigo?

    • @carlsmiff1936
      @carlsmiff1936 13 днів тому

      @@AlbertoSanchez-jo5og somamente uno.

  • @ma7rix13
    @ma7rix13 3 роки тому +2

    This is more of a what not to do video. Please ppl, do not just wrap 240v wire and tape it. = bad! Please don’t mount heaters on stools while loosely being connected to said wires. … think about it… you have a high water / moisture pool house in this video with plumbing all over the place. Someone trips or knocks that thing over… wire gets disconnected… buzz buzz … go meet your maker.

    • @SerenityMusicOasis
      @SerenityMusicOasis 3 роки тому +2

      The guy in this video is probably dead by now...And anybody swimming in that pool too...Geeezus

  • @cesarsanchez9566
    @cesarsanchez9566 5 місяців тому

    Does anyone here know how to prepare the heater? I already connected the 2 phases, the neutral and the earth ground, the heater just turns on, but the light bulb does not turn on where it says heating :( can someone help me

    • @barzdun
      @barzdun  5 місяців тому

      hi! send me couple pics of your wiring and basic pics of the heater - will see if i can help you

    • @barzdun
      @barzdun  5 місяців тому

      the maill ... north2005 at g m a i l c o m - can rwrite normally because the you tu be filters

    • @carlsmiff1936
      @carlsmiff1936 13 днів тому

      All I can say is make damned sure it has enough water flowing through it, first

  • @tropicaloasis8203
    @tropicaloasis8203 5 років тому +1

    What size wire did you use? I have same setup, planning to use 12/3

    • @outdoorsurvival7730
      @outdoorsurvival7730 4 роки тому +1

      Tropical Oasis 10mm

    • @jarrydee2799
      @jarrydee2799 3 роки тому

      Looks like there is no neutral required, so 12/2 would be fine. Black tape on both ends of the white wire to show it's a hot and you are good to go

    • @samiortezthedictionary5968
      @samiortezthedictionary5968 2 роки тому

      I’m have the same one and I’m use #6 wire Bc the breakers is 50 amp but I’m have issues Bc I don’t have neutral.?

  • @danielhughes8013
    @danielhughes8013 4 роки тому +6

    That’s some of the worst wiring I’ve ever seen! 🙈⚰️

  • @MrTantalust
    @MrTantalust 4 роки тому +4

    "Coasts" is supposedly a counterfeit scam/rip/off name for "COATES" heaters. ??

  • @chrisgamingzone502
    @chrisgamingzone502 Рік тому

    Thanks I just but

  • @cesarsanchez9566
    @cesarsanchez9566 5 місяців тому

    Alguien de aquí sabe cómo hacer prender el calentador? Ya conecte las 2 fases, el neutro y la tierra física, nomás prende el calentador, pero no prende el foco donde dice calentando :( alguien me puede ayudar?

    • @barzdun
      @barzdun  5 місяців тому

      Hola, envía una foto con la disposición de tus cables y algunas fotos generales del calentador. Si puedo, te lo explicaré.

    • @AlbertoSanchez-jo5og
      @AlbertoSanchez-jo5og 14 днів тому

      ​@@barzdunamigo ese tipo de calentador se puede instalar de 110 watt? Aunque sea de 220

    • @barzdun
      @barzdun  13 днів тому

      @@AlbertoSanchez-jo5og can be, but you need to use both wires of 110 coming to your box. then you get 220-240 aprox.

    • @carlsmiff1936
      @carlsmiff1936 13 днів тому

      @@AlbertoSanchez-jo5og download the manual, info is in there.

  • @josephcilia8762
    @josephcilia8762 4 роки тому

    I have wired my pool heater but the wire gets hot can tell me why please

    • @domingorios8117
      @domingorios8117 4 роки тому

      Need to up the wire size and possibly the breaker

    • @Jericho_bella
      @Jericho_bella 4 роки тому

      Domingo Rios u don’t just tell someone up the wire and possible the breaker ask what size breaker is needed and ask what size wire they are using before u potential burn someone’s house down

    • @outdoorsurvival7730
      @outdoorsurvival7730 4 роки тому

      10mm

    • @luistorres6
      @luistorres6 4 роки тому

      What #breaker to use for this heater?

    • @djbraca6581
      @djbraca6581 4 роки тому

      I just bought the same heater can someone how to properly connected wires and all please thanks

  • @worthington5687
    @worthington5687 2 роки тому

    Do these heaters really require vertical mounting as shown? In other words, will it work okay lying on it's back, flat?

    • @barzdun
      @barzdun  2 роки тому

      i used on the angle and also - before mounted permanently - was on the side. worked. all of the problem in these - can be the sensor inside the u-pipe - water channel inside the box, but this generation don't have any moving part inside - sensor for the stream - is electronic or somehow made without any lever or other moving part, so position doesn't matter. but, anyways - this my personal opinion and i'm not technician or installer... do what you want to do :) better be sure on breaker - give a little more amps. mine was changed couple times . 18 kw heater - 20a - worked for few months and started to overheat. maybe the quality... replaced with 25 - no problem. good luck!

    • @thenathanielhardyproject8675
      @thenathanielhardyproject8675 7 місяців тому

      @@barzdunFor a 18kW heater you need at least a 75amp breaker.

  • @darrenmarsh3068
    @darrenmarsh3068 2 роки тому

    Can't get it running for more than 2 nights then it stops and I have to change parts or it leakes everywhere

  • @metou3072
    @metou3072 4 роки тому +13

    someone needs to teach this guy how to use teflon tape...im not exaggerating...he literally started wrapping the threads with the teflon tape at 0:50 and does not finish until after 2:00 in the video...how the hell is the company he works for supposed to make money when he uses a $5 roll of teflon tape for each and every joint...you have got to be joking...there is not a roll of teflon tape anywhere near this guy in a 50 mile radius...dude has to stop at 7 hardware stores to get enough teflon tape to install something simple like a water heater...unreal!!!! 🤣🤣🤣🤣🤣

    • @pierreverdoni
      @pierreverdoni 4 роки тому +2

      NEVER seen so much teflon OCD !!!!

    • @Jericho_bella
      @Jericho_bella 4 роки тому

      I’m surprised the damn female threaded on it was so thick of tape

    • @Jesse8478
      @Jesse8478 4 роки тому +1

      dude what the fuck i was thinking the same thing this gucking guy is god dam crazy that fucking triggers me

    • @secomeco724
      @secomeco724 3 роки тому +1

      🤣🤣🤣🤣🤣🤷‍♂️🤷‍♂️😜😜😜

    • @milehigh3494
      @milehigh3494 3 роки тому +1

      And this what a crack head looks like using Teflon tape🤦😏🤣🤣🤣🤣🤣🤣🤣🤣

  • @cristianrodrigues6233
    @cristianrodrigues6233 3 роки тому

    I bought this heater for Argentina.... here we have 220v at oulets.... but I saw that the heater needs 50Amper to work??? is it possible? Common home connections doesn't have that power....... Thanks!

    • @worthington5687
      @worthington5687 2 роки тому

      Wire directly to your panel. It needs tons of current. Never even TRY a standard outlet.

  • @secomeco724
    @secomeco724 3 роки тому

    Can this heat up 20,000 gallons pool.

    • @worthington5687
      @worthington5687 2 роки тому

      Yes, depending on the model and where you live and how quickly you need the water heated. . I got the biggest 27 one.

  • @joeyv9886
    @joeyv9886 4 роки тому +1

    Black text would of made it easier to read FYI 😉

  • @Justadadandmore
    @Justadadandmore 3 місяці тому

    WTF! That was so sketchy. The irregular cut outs for the inlet and outlet because they dont have the correct machine to just punch the correct sized hole, that packing tape wrapped around the wires that are just twisted together, entire roll of ptfe tape per nipple, the only thing missing is a guy cutting metal with a grinder using is bare feet to hold the metal...

  • @tvillan2000
    @tvillan2000 3 роки тому +2

    that's too funny ! I hope someone doesn't buy this and wires it just like the guy in this video. what a shock their going to get when they flip the switch . 220V Yikes!

    • @darrenmarsh3068
      @darrenmarsh3068 2 роки тому

      Payed an electrician to put it in and almost everything has blown i have 2 elements and it leakes everywhere

    • @worthington5687
      @worthington5687 2 роки тому

      No lie, look at his carton/packing tape on the splices, then touching right on the metal edge... WTF, hope that wasn't a permanent wiring job. 😮

  • @barzdun
    @barzdun  5 місяців тому

    hey - i see there a lot of "professional's" tellin shit about dangerous wiring and so. i highly recommend - then don't touch the water and... at all... and go and f***k yourselves with no pool and get vacsinated again!

  • @carloschavez453
    @carloschavez453 3 роки тому +1

    This is a FAKE UNIT the real one is spelled COATES

  • @MontrealDentistry
    @MontrealDentistry 2 роки тому

    this is tooo Lol, sketchy af!!! typical made in China. i was wondering about these heaters and this video made me confirm to stay away from this unit, and please do not wire your stuff like this.

  • @captain5969
    @captain5969 4 роки тому

    China product