How to install downlights LED spotlight wiring How to wire LED down light

Поділитися
Вставка
  • Опубліковано 31 жов 2018
  • Hi. This video is about the LED downlights installation . I am showing how to wire it, make a ceiling holes and install 5 downlights on kitchen ceiling. Thank you for watching. Please Subscribe
  • Навчання та стиль

КОМЕНТАРІ • 272

  • @user-yw6qb9tt7t
    @user-yw6qb9tt7t 2 роки тому +2

    This guy is the best. What the eye doesn't eventuality see doesn't matter.

  • @francisokufi7968
    @francisokufi7968 3 роки тому +7

    absolutely brilliant you showed the full works how to do it including cutting the ceiling to get to the other sides and said how to fix the unwanted holes... fabulous

    • @amitdasor6171
      @amitdasor6171 3 роки тому

      When did he say how to full the holes?

  • @jimadams244
    @jimadams244 5 років тому +3

    what a clever way to do it ive often wondered how to solve this problem if you cant lift the upstairs floor and thanks to you now i know

  • @vbroder15
    @vbroder15 3 роки тому +2

    O man, so many holes. Good for plaster and painter. Thank you for your video.

  • @amitdasor6171
    @amitdasor6171 3 роки тому +6

    Would have been nice to see how you fill the holes. Great video, enjoyed watching and learning.

  • @paulweasel1
    @paulweasel1 4 роки тому +1

    A really great video tutorial - thanks!

  • @Colesy1978
    @Colesy1978 5 років тому +17

    I've never been able to work out how to loop the wires into a fixed plasterboard ceiling and now that explains it. Just need to learn how to plaster the holes up now :) Addicted to your clear and simple vids. Nice one!

  • @fielding68
    @fielding68 4 роки тому +1

    Great tutorial. Thank you.

  • @baweasel
    @baweasel 3 роки тому +2

    Very good, great detail! Thanks for this video m8!

  • @localgoat4176
    @localgoat4176 3 роки тому

    Simple and direct. Thanks.

  • @swidishtofu749
    @swidishtofu749 3 роки тому

    Thx! Got my thought of method confirmed, now i can start working on it and stop wonder if it will work! ^^

  • @enayatassadi5553
    @enayatassadi5553 3 роки тому +9

    I wish you showed us how to block the holes as well, btw it was brilliant and thanks a lot

    • @sprig6043
      @sprig6043 Рік тому

      I was just thinking the same and looking for videos of his that show the hole blocking grrrr!

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 11 місяців тому

      If you cut circular holes you keep the cut outs and best number them. Then to replace you put a 8 to 10 mm thick short piece of flat wood up into the hole which extends half the diameter of rhe hole either side . you can put a screw in it to pull the wood down onto the ceiling or use your fingers on top of the wood to hold down. You use a drywall screw up through the ceiling to hold the said wood both sides then screw your cut out to that piece of wood. It is how plasters patch fill dry wall. If they have an unsightly hole they cut an even shape in the drywall and fill it with a piece of drywall the same size and shape holding it as aforesaid.

  • @ratskirobo4836
    @ratskirobo4836 4 роки тому

    Nice ceiling decor!

  • @Adnanbest1
    @Adnanbest1 3 роки тому +2

    Love the video now I wana see the plaster work and texture and how’s its look after

  • @Grumpy_huskie
    @Grumpy_huskie 2 роки тому

    Great video! So straightforward!

  • @jontom7787
    @jontom7787 2 роки тому

    Thanks brother, this was a perfect guide.

  • @Gnome008
    @Gnome008 3 роки тому

    Thanks for this! I've got downlights in my bathroom and want to replace them (they're covered in paint and the previous owners were not so good with the DIY so I dont know if they are correctly rated at IP65), so really glad you also explained that they're easy enough to take out

  • @ratchriat1716
    @ratchriat1716 5 років тому +2

    you mad it easy and simple loved the video

  • @connyberg5665
    @connyberg5665 3 роки тому

    Thanks! Very informative video!

  • @orbepa
    @orbepa 4 роки тому +5

    Great simple explanation - I'm now a subscriber. Thanks for taking the time to make it

  • @rllrll2166
    @rllrll2166 4 роки тому

    best video on this! thanks

  • @joeqasim1
    @joeqasim1 4 роки тому

    Great video thank you very much.

  • @61shapnevduke
    @61shapnevduke 2 роки тому +2

    Excellent! I'm just about to do the same job and this made everything very clear on how to wire everything - just a daisy chain of downlighters really. Many thanks

  • @jasonrichards6504
    @jasonrichards6504 4 роки тому +5

    Really good video thank you! Im starting an electrician course and these videos are great and helping me prepare

    • @wyndavies5044
      @wyndavies5044 2 роки тому

      I wont be watching his videos to learn how to be an electrician! RAF!

    • @jasonrichards6504
      @jasonrichards6504 2 роки тому

      @@wyndavies5044 good for you….

  • @OldFloatingSeaman
    @OldFloatingSeaman 4 роки тому +2

    I use a Wago box and connectors with a fly lead to the fitting as this stops any undue strain on the fitting itself causing it to move.
    The springs are good for single leads but struggle to hold their position with multi cables attached.

  • @BangladeshNewsOfficial
    @BangladeshNewsOfficial 4 роки тому

    It’s great work 😍

  • @martinwarner1178
    @martinwarner1178 2 роки тому

    Good video, clear method. Thank you. Peace be unto you.

  • @umraosingh8374
    @umraosingh8374 4 роки тому

    Great work man

  • @deltabanduk
    @deltabanduk 4 роки тому +4

    Hole sole :-) Love it!

  • @rbfreitas
    @rbfreitas 3 роки тому

    Great video! Thanks for sharing

  • @jswaldred
    @jswaldred 4 роки тому

    very good. thank you

  • @harrymcmahon6876
    @harrymcmahon6876 3 роки тому +2

    Thank you. But any tips on how to thread the cable from hole to hole?

  • @ciao532
    @ciao532 Рік тому

    Another fantastic job 👏

  • @Clydepatos2001
    @Clydepatos2001 5 років тому +1

    Great video is only way to pass this cables, as circuit is protecteted RCD does not matter 50 mm

  • @eemirali2658
    @eemirali2658 3 роки тому +1

    Really good tutorial, do you train new starters?

  • @robbo0tr
    @robbo0tr 5 років тому +1

    How would you deal with the earth if it’s a single cable? I.e end of the line device

  • @soloman4386
    @soloman4386 4 роки тому +1

    Excellent video

  • @rulechange6329
    @rulechange6329 Рік тому

    Great videos, clear instruction, reassuring.
    Thank you

  • @siukss
    @siukss 5 років тому

    Super filmik

  • @yasarashraf4662
    @yasarashraf4662 3 роки тому +1

    What model down lights did you use mate are they any good?

  • @stopwatch584
    @stopwatch584 2 роки тому +1

    Brother your video is great, can you make video how to construct House footer, please lots of love for your nice video.

  • @alexandresouza8174
    @alexandresouza8174 3 роки тому

    Nice explanation

  • @EnigmaPSU
    @EnigmaPSU 4 роки тому +4

    Perfect...example of a hack job.

    • @chrisshenton7467
      @chrisshenton7467 4 роки тому

      Genuine question; have you got a better tutorial? Planning on doing this in the kitchen soon but would rather avoid making the additional holes and the reskim that I'm guessing the wife would insist on!

    • @mbrofc
      @mbrofc 4 роки тому +3

      Chris Shenton use a wood chisel for the ceiling plaster where the joists are and take a bit of wood out enough for the thin wire only.
      Feed the electrical wire with a wire coat hanger (taped) fish it past all the joists using this method and simply plaster the small channels you made with the chisel.

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 2 роки тому

      @@mbrofc baloney. Not compliant with bs7671 in any event if cutting into joists and not protecting cables so routed with armour

  • @pqjzheng
    @pqjzheng 3 роки тому

    what brand is your led pot light and where did you buy them?

  • @panapasatawakece9408
    @panapasatawakece9408 9 місяців тому

    Keep up the good work👏

  • @mohammmedpatel8044
    @mohammmedpatel8044 2 роки тому

    Very good 👍🏻

  • @MMG_MoonManGuitar
    @MMG_MoonManGuitar 5 років тому +1

    Nice to have u back on youtube pal.

    • @how2d223
      @how2d223  5 років тому +1

      Thanks. I was just too busy at work and some other troubles.

    • @mohamadboodhoo
      @mohamadboodhoo 5 років тому

      Can you use 1.5 cable?

  • @Smiler7
    @Smiler7 Рік тому

    Excellent!!

  • @ChrisLivingInYork
    @ChrisLivingInYork 5 років тому

    How do I connect a loop in when there is only a neutral and live connection. Can I use a wago connector like you used on the earth

  • @m.k.rahmathali9633
    @m.k.rahmathali9633 5 років тому +1

    I save your money and time

  • @imyimz786
    @imyimz786 5 років тому +4

    Amazing job I had same situation laminate floor above kitchen lol

  • @philtaylor3098
    @philtaylor3098 3 роки тому

    Perfect.

  • @DISCODAN1
    @DISCODAN1 Рік тому

    Das ist großartig und danke für dein Video. Ich installiere die genauen Lichter in meinem Büro und das war sehr hilfreich! Danke von der anderen Seite des Teiches!

  • @CF-Gaming01
    @CF-Gaming01 5 років тому

    What IP rating do you recommend for directly above a shower for a bathroom with no extractor fan. However a large window is open when in use?

    • @blakegriffin172
      @blakegriffin172 4 роки тому +2

      Its not about recommendations you need to follow the regs. Page 94-95 of on site guide. Fan/windows makes no difference. IPx4 minimum if over 2.25m in height. IPx5 if under 2.25m in height. Remember to use SELV if the circuit is not rcd protected. Also it is notifiable work so must be signed off by an building control (or via a qualified spark)

  • @user-pb6zk7nx5e
    @user-pb6zk7nx5e 4 роки тому

    Whats the maximum spotlight can you replace?

  • @metubeusercom
    @metubeusercom Рік тому

    Thank you sir

  • @womblestacker7993
    @womblestacker7993 5 років тому

    What about cables in celling

  • @mothaerorisangtimothy1534
    @mothaerorisangtimothy1534 2 роки тому

    That was awesome

  • @spendtimesavemoneydiy
    @spendtimesavemoneydiy 5 років тому +5

    Great video! Do the cables not have to be 50mm up going through a joist?

    • @how2d223
      @how2d223  5 років тому

      Yes it should be ! But I think 90% of electricians will do it this way and nobody cares. It s just the easiest way to do it.

    • @supersparks9466
      @supersparks9466 5 років тому +6

      @@how2d223 count me in the 10%

    • @DrummerOnTwoWheels
      @DrummerOnTwoWheels 4 роки тому +5

      How2D2 90%? You’re having a laugh, man. This is rough as toast. Always drill through the joists to avoid penetration of nails etc. Earth cables not sleeved and single insulation showing on entry to fittings and cable clamps not used.
      This is not how you install downlights.

    • @nickgilbert1264
      @nickgilbert1264 4 роки тому +3

      @@DrummerOnTwoWheels What is the purpose of sleeving an earth cable when the entire metal fitting is connected to earth? For such a short length, this achieves nothing.

    • @DrummerOnTwoWheels
      @DrummerOnTwoWheels 4 роки тому

      Nick Gilbert sleeving the earth identifies the conductor, you would understand that if you were an electrician. Rough as toast.

  • @robjackson3510
    @robjackson3510 3 роки тому +9

    If you are to do the work from this room, you should cut hatches in the ceiling large enough to drill through the joists at least 50mm from the ceiling, this method is not code and presents a dangerous future proposition re heating of wires and safety from nailing the wire... hey itll work the lights for this demo, but its incorrect on many levels of safety.

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 11 місяців тому

      If mechanically protected running notched in joist you are allowed do this. Joists are notched on top for cables. Is all that wrong for not being 50mm from top.

  • @Jamie-km2sl
    @Jamie-km2sl 3 роки тому +1

    Your amazing

  • @mango3586
    @mango3586 5 років тому +6

    good video make another video showing how you filled the un used holes

    • @davejones4740
      @davejones4740 5 років тому +8

      mango3586 you would save the piece that came out of the hole saw, next you get a small piece of wood and feed up into hole, net use screws plasterboard screws to fix into the wood that has been passed up through hole then the pieces can be screwed to wood that's in hole and finally easy filler to make good, sand and then painting, etc.

  • @raj080288
    @raj080288 6 місяців тому

    do you not need to sleeve the cpc in the spot light?

  • @fireblaster9961
    @fireblaster9961 4 роки тому +1

    All this work and finish work for 4 led down lights

  • @eglantina6
    @eglantina6 3 роки тому

    Very good

  • @clivelikumbi
    @clivelikumbi 5 років тому +2

    Best DIY Video I have watched so far

    • @DrummerOnTwoWheels
      @DrummerOnTwoWheels 4 роки тому +5

      Clive Likumbi must be the only one you’ve watched, then.

  • @anwaranazi531
    @anwaranazi531 4 роки тому +1

    Thank you it was very useful and great work. But from where the electrical coming for the new spotlights? Please mention that how you connected the center-point cable for the new spotlights. BR,

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 11 місяців тому

      Wagos in a box. My wife could do it

  • @womblestacker7993
    @womblestacker7993 4 роки тому +4

    Did you say 1mm cable

  • @davidshanahan3693
    @davidshanahan3693 5 років тому +9

    Good video. Did you notch the joists to let cable pass through ?

    • @paulhill2012
      @paulhill2012 3 роки тому +1

      No, his hole saw drilled the joist enough to pass the cable through

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 2 роки тому +1

      @@paulhill2012 how 🤔?

    • @paulhill2012
      @paulhill2012 2 роки тому

      @@user-yw6qb9tt7t directly from underneath. He drilled a 70mm diameter hole into the centre of the joist that removes the ceiling and a piece of joist. He does that for each joist. I doubt that it is allowed under regulations.

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 2 роки тому +1

      @@paulhill2012 he is using a hole saw. That will not remove a piece of joist. A spade bit would but not a hole saw. What has happened is he says in reply to a comment that there was lathe and plaster with plaster board over so this has given him the clearance to put back in the cut out plasterboard leaving out the lathe and plaster cut out. It is all in breach of bs7671 to run cables across joists if not either 50mm deep or mechanically protected as in this case someone may unknowingly put another layer of plasterboard on and screw into the unprotected cables

  • @PsychedelicKen
    @PsychedelicKen 4 роки тому +4

    In the UK, would a part P qualified electrician be required to do this work? As I plan to install down lights in my kitchen soon.
    I think I'd prefer the cables passing through the timber though.

    • @OldFloatingSeaman
      @OldFloatingSeaman 4 роки тому

      If you are drilling through joist then you will be governed by Part P Regulations. If you also installing a new circuit, this is also notifiable under Part P

    • @SqwarkParrotSpittingFeathers
      @SqwarkParrotSpittingFeathers 4 роки тому +1

      @@OldFloatingSeaman And, isn't it notifiable because it's in the kitchen?

    • @OldFloatingSeaman
      @OldFloatingSeaman 4 роки тому

      Keith C Some work in Kitchens is now exempt but a new Cooker circuit is notifable Just one example.

    • @SqwarkParrotSpittingFeathers
      @SqwarkParrotSpittingFeathers 4 роки тому +1

      @@OldFloatingSeaman Thanks for that clarification. But, this video is worrying, he appears to know the correct way but doesn't care.

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 11 місяців тому

      He's is fine apart from not mechanically protecting the cable running under each joist. For that you would get told by an assessor to rip it all out

  • @ja_adam_
    @ja_adam_ 5 років тому +12

    I would say you should have cut out plasterboard before the joist with a padsaw enough to drill through the actual joist so that the cables are not against the joist and plasterboard. Also you should really be putting Earth sleeping on the CPC’s before they enter the push connectors. It seems like you have also left off the cord grips supplied with the downlights? Cord grip should be on and gripping the outer sleeving and not the conductors, and there should be a lid provided that screws on over the terminals? There should be no single insulated conductors showing, best way would have been use a choc box and take a flex to each downlight ?

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 11 місяців тому

      Reference methods allow for cable to be against plasterboard surface so is the OSG wrong ?

  • @m.k.rahmathali9633
    @m.k.rahmathali9633 5 років тому +5

    Brother give me one chance.i do wiring without any extra holes

  • @phomzaraboon7688
    @phomzaraboon7688 3 роки тому +7

    Would have liked to see finished ceiling after plugging in holes and plastering

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 11 місяців тому

      This is not a plastering video. Any plasterer can tell you how it is done. By smoking roll ups waiting for the first coat to be ready for top coat

  • @mattyboy2037
    @mattyboy2037 5 років тому +2

    I'm confused about the cables under the joists bit. If the joists are untouched how do you seat the old bit of plasterboard properly into position to fill the holes back up. Surely the cable you've installed will prevent this.

    • @supersparks9466
      @supersparks9466 5 років тому +1

      Your right to be confused, it’s someone playing at being a electrician instead of being a professional

    • @BMRProductions
      @BMRProductions 5 років тому +1

      Notice he marked where each stud joist was. Then cut the extra holes where the joists were. Cables go over the joists, not under, then he uses the cut out holes and screws it back in to each stud. Very simple.

    • @daveharvey8425
      @daveharvey8425 3 роки тому +8

      He clearly states he's running the cable under the joists and can be seen doing so.

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 2 роки тому +1

      In any case how could you run the cable over the joist from a 70mm circular cut out centred on a joist

  • @DerekHundik
    @DerekHundik 5 років тому +15

    What do you mean passing cables uder the joices ? Aren't plasterboards attached to the joices ?

    • @davejones4740
      @davejones4740 5 років тому

      1000fantomas he would use hole saw to cut into areas where joists are going across ceiling, he has no access from above. So I guess the hole saw could be used by measuring to locate joists and the underside of the joists cut , to pass cable under joist. Normally joists are located to standard span distances. Metal detectors could be used to locate plasterboard screws that are used to fix plasterboard to joists.

    • @DerekHundik
      @DerekHundik 5 років тому +2

      Dave Jones i do that on the daily bssis. It doesn't show how he passes the cable.

    • @how2d223
      @how2d223  5 років тому

      The joists are remains untouched and I slide the cable underneath them so if there is a single plasterboard - cables are almost inside the thickness of plasterboard. in this video I have old ceiling with the wooden stripes covered with old cement based plaster and one layer of plasterboard ( unexpected) so cables are under the joists at a depth of around 3 cm

    • @danhatcher7455
      @danhatcher7455 5 років тому +1

      @@how2d223 Still not getting it. So you're not drilling into the joist, you're drilling beside the joist and then creating a 3cm channel in plasterboard to go under joist?
      I would do similar but drill a another hole into the joist (through the hole in the plasterboard)
      Thank you for video very good but you appear like a magician how you get cables through.

    • @Jackzuk
      @Jackzuk 5 років тому +2

      Great vid but im confused how there is a gap between the joists. Are the counter battens between the joists and ceiling? It sounds like your saying there is plasterboard over old lath and plaster ceiling but still cant imagine where there is a gap unless there are counter battens, thanks

  • @DerekTJ
    @DerekTJ 3 роки тому

    What's that connector you used for the redundant earth wires?

  • @MrGine77
    @MrGine77 5 років тому +5

    I think before you start to drill the holes in the selling you should check or there any cable's or pipes in the selling ( safety ). Cable all ready was in the selling. How do you know from where cable are going and wich direction? And then there is space between the joint ant plasterboard for cable?

    • @indokarasan
      @indokarasan 4 роки тому

      ceiling, already, which and "and"

    • @luxiaainteriors
      @luxiaainteriors 4 роки тому

      indokarasan This truly made me laugh. Bless MrGine77 😊. Also I believe he meant ‘joist’ instead of ‘joint’.

  • @evaali6025
    @evaali6025 4 роки тому

    👌🏻👏🏻

  • @SY-ml5nl
    @SY-ml5nl Рік тому

    So you connected the new wire to the old wire light so they work with the same old light switch on the wall? But what about the earth wire? You put it in a clip, are they touching? Or is that a seperate wire holder clip? Is that not dangerous? Having no earth wire?

  • @dodongworks
    @dodongworks 4 роки тому

    lain kaayo tan-awon imong alkuba chui kay daghan kaayog bangag

  • @myheaven2626
    @myheaven2626 2 роки тому

    May i know how mm is the gypsum board please

  • @ek6868
    @ek6868 5 років тому

    👍👍👍

  • @frenchfries2378
    @frenchfries2378 3 роки тому

    Hi, where are you based?

  • @lelds57
    @lelds57 5 років тому

    Where did you bought this led ?

  • @randy6334
    @randy6334 3 роки тому +1

    I don't understand how to plaster the ceiling where you can't see it. That ceiling had a texture. What if it had popcorn or drop down. How do you cover up stuff like that without being able to see the repair?

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 2 роки тому

      You cannot disguise the holes. He kept the cut outs to replace but some marks will be left afterwards no matter what you do

  • @ozzyollie5870
    @ozzyollie5870 Рік тому

    Hi , i just replacing my old light bulb to led downlight n the old light got 3wires, but the led only need 2 wires, what should i do with the earth wire? Thx

  • @waseemakram9352
    @waseemakram9352 4 роки тому

    Very nice and helpful.

  • @shaunmcgovern5877
    @shaunmcgovern5877 2 роки тому

    I would use a Dade dust catcher

  • @ariftanoli9768
    @ariftanoli9768 4 роки тому +1

    There is no doubt in my mind you are the best Electrician youtuber.

  • @bahavujames401
    @bahavujames401 4 роки тому

    what a great idea...

  • @rdl4028
    @rdl4028 5 років тому +1

    thankyou very good video well done

  • @KGBgringo
    @KGBgringo 4 роки тому +3

    ITT people saying everything is wrong but not saying why.

  • @oscar_led343
    @oscar_led343 4 роки тому

    like it

  • @stephentraquair305
    @stephentraquair305 3 роки тому

    Anyone tell me how to replace the bulb in these or do you have to replace the whole unit ?
    Thanks lads.

    • @delboypass
      @delboypass 3 роки тому

      Remove downlight and replace GU10 bulb.. no you dont need to replace unit

  • @paull557
    @paull557 3 роки тому +6

    Great video but can anyone tell him that the Artex contains asbestos? Watching drilling a hole without wearing respirator with right filter makes me concern.

    • @philhowells7715
      @philhowells7715 2 роки тому

      There's always one!

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 2 роки тому

      Only about 10 per cent asbestos and then white asbestos. All poles smoke so no concern

  • @crystaldavies3197
    @crystaldavies3197 5 років тому +2

    What about beams. Won't they be in the way at some point?

    • @indokarasan
      @indokarasan 4 роки тому

      I was thinking the same. I would measure from inside the loft

    • @user-yw6qb9tt7t
      @user-yw6qb9tt7t 2 роки тому

      Electric cables penetrate everything

  • @mikardo8864
    @mikardo8864 4 роки тому +2

    How much would an electrician charge for a job like this (including materials)?

  • @omarayala4799
    @omarayala4799 Рік тому +1

    what size wire did you use

  • @DGT73
    @DGT73 2 роки тому

    Trying to work out how to wire these in a 2 way lighting circuit 🤷🏻‍♂️

  • @pullunikoyakutty1187
    @pullunikoyakutty1187 5 років тому

    Why u make too hole only four light