A look inside / mini review: Fluke 28 II EX (Pre-production model)

Поділитися
Вставка
  • Опубліковано 20 лис 2012
  • A look inside and review of the Fluke 28 II EX (Intrinsically Safe) Multimeter.
    Discussion and pictures on my forum:mjlorton.com/fo...
    -------------------- Click "Show more" ------------------------------
    My website and forum:- www.mjlorton.com
    Donations and contributions:- www.mjlorton.com
    My techie channel MJLorton - Solar Power and Electronic Measurement Equipment - / mjlorton
    My Techie Amazon Store: astore.amazon.c...
    My other channel VBlogMag - For almost any topic under the sun! - / vblogmag
    My VBlogMag Amazon Store: astore.amazon.c...
    -----------------------------------------------------------------------
    Thanks to Comtest for the loan of the Fluke 28 II EX: www.comtest.co.za
    Purchase the Fluke 28 II here:
    astore.amazon.c...
    My full review of the normal Fluke 28 II:
    • Multimeter review / bu...
    Overview:
    Now there's one intrinsically safe digital multimeter (DMM) you can use in IIC (gas), in Zone 1 and 2 and IIIC (dust), Zone 21 and 22. Whether you work in petroleum, chemical, or pharmaceutical environments, all the test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built. The Fluke 28 II Ex is also waterproof, dust-proof and drop-proof. You'll be equipped to handle any situation, inside and outside of hazardous zones, without compromising compliance or measurement performance.
    Detailed information here:
    www.fluke.com/f...
  • Наука та технологія

КОМЕНТАРІ • 51

  • @aptsys
    @aptsys 11 років тому +10

    Ah. Finally a multimeter that's safe to use in the W.C.

  • @mjlorton
    @mjlorton  11 років тому

    Yes, correct...thanks for the input.

  • @AintBigAintClever
    @AintBigAintClever 11 років тому +1

    Nice teardown. Not many people will get their hands on one of these, let alone whip the cover off!

  • @mjlorton
    @mjlorton  11 років тому

    Thanks for the input.

  • @antraciet
    @antraciet 11 років тому

    Indeed. They exists for a long time, but the last few years they are getting more popular, for the DIY also.

  • @deathventure
    @deathventure 11 років тому

    The front daughter board is for further input protection, they are an array of DF series full wave bridge rectifiers. If I saw right, on the back daughter board, there were two small relays, so I believe those are also contributing to input protection. Something to do is to look up the actual part numbers to get more insight on what they do.

  • @SteveRobReviews
    @SteveRobReviews 11 років тому

    Fantastic, well done Martin,thanks !!

  • @chrispychickin
    @chrispychickin 11 років тому +2

    I'll bet Dave watched this and thought, "damn, why didn't I get one of these!"

  • @matlesterdivinagracia6528
    @matlesterdivinagracia6528 2 роки тому

    I think that green one that connecting the big redistor that you called MOV is a PTC

  • @willywgb
    @willywgb 11 років тому +1

    Martin
    The screws that fasten the back cover on this Meter are called Torx (pronounced torks)
    Willy

  • @bambam144
    @bambam144 10 років тому

    great video thx a lot martin
    and a big thumbs up for this beautiful mulitmeter

    • @mjlorton
      @mjlorton  10 років тому

      bambam144 My pleasure.

  • @nuntana2
    @nuntana2 7 років тому

    Great, thanks. Fantastic bit of kit.

  • @Monkeh616
    @Monkeh616 11 років тому

    Yes, that's an SMT inductor. Dave Jones had to replace the same part several times on his 28II after drop testing.

  • @ComplexPole
    @ComplexPole 9 років тому +2

    The 4-pin SMD devices on the top daughter board look to be bridge rectifiers.

    • @movax20h
      @movax20h 6 років тому

      These are probably clamping diodes.

  • @designdemos8021
    @designdemos8021 4 роки тому

    The 'gunk' you refer to that encapsulates the 440ma fuse and used on the board is a potting gel - Arnocanali Isol Gel.
    This fuse assembly (part no. 4016494) is hard to get hold of and relatively expensive at 40EUR compared to the regular Bussmann DMM440/100 (440mA, 1000V, 10.3 (Dia.) x 35mm) fuse it contains.
    You can quite easily dig the fuse out of the gel compound and reinstall with the potting compound, cost 12GBP via fleabay plus the cost of the fuse, a round 5GBP.
    The trick to re-potting is to correctly align the pins while setting in the gel. I created a 3D print to locate the pins precisely. Contact me and I'll make them available.

  • @peterxhudo5177
    @peterxhudo5177 10 років тому +4

    are you sure the production 28ii ex came with a bar graph? I just purchased one and it doesnt have a bar graph and fluke was no help
    the production date is 09/11

    • @bouipozz
      @bouipozz 3 роки тому

      Also looking for info on this

    • @filipsz6728
      @filipsz6728 Рік тому

      I just made some small research and looks like the one without bargraph has bigger digits.

    • @Die-Spezialisten
      @Die-Spezialisten Рік тому

      I got 2 new ones. Both without bargraph. The newest one is from 2021

  • @deathventure
    @deathventure 11 років тому

    A likely event is that high voltage creates arcing over that particular fuse more so than the second fuse so they pot it to avoid the possible arcing to other components. Given that it's a prototype, they've probably done something different with the release to market version.

  • @mjlorton
    @mjlorton  11 років тому

    All account are generally approved within 24 hours. What probably happened is that you did not receive the confirmation email. Try login, if there's a problem email me. Cheers, Martin.

  • @mjlorton
    @mjlorton  11 років тому

    Thanks...correction made with an annotation.

  • @mjlorton
    @mjlorton  11 років тому

    Torx / torks...thanks, Willy!

  • @Monkeh616
    @Monkeh616 11 років тому

    XAF1 and XAF2 are the 2mm banana sockets for the 440mA fuse.

  • @DanFrederiksen
    @DanFrederiksen 11 років тому +1

    The Ex doesn't stand for explosive, it stands for expensive :) 1150$ retail.
    I think you could have used the expression 'for the price' a couple of times here : )

  • @Die-Spezialisten
    @Die-Spezialisten Рік тому

    IMPORTANT!!!!!
    Watch out for the batteries. If you use normal Alkali batteries, check them regularly or change them. When they leak, the gases can not get out and the dirt gets on the PCB. The gases can destroy the pcb. Also the housing plastic will be destroyed. My 28-2ex is dead because of that. The new one has got Lithium AAA batteries.

  • @mjlorton
    @mjlorton  11 років тому

    If you watch T4D #31 I explain why it's gone...hope to have something back soon.

  • @SolidStateWorkshop
    @SolidStateWorkshop 11 років тому

    MOVs are usually shiny. PTCs are usually a matte finish

  • @filipsz6728
    @filipsz6728 Рік тому

    Can someone tell me where I can buy holster for this meter?

  • @mjlorton
    @mjlorton  11 років тому

    Yes...didn't think of that! ;-)

  • @NaveedAhmad-cd8op
    @NaveedAhmad-cd8op 2 роки тому

    I have Fluke 28 ii ex multimeter after replacing the MOV's now it's showing 600-ohm resistance instead of unlimited resistance. Please share your experiences?

  • @mjlorton
    @mjlorton  11 років тому

    Remember this is based on the original Fluke 28 II so that board might be from then.

  • @spagamoto
    @spagamoto 11 років тому

    28:00 Copyright 2008? This thing was made in 2012... perhaps they didn't update the board text?

  • @bkupiec
    @bkupiec 11 років тому

    I wonder why only one fuse (440mA) was potted?

  • @NicuIrimia
    @NicuIrimia 11 років тому

    c'mon Martin, can't you just see the LED (D56) at 27:36 ? it sit's in the middle and top and bottom "bits" are receivers :)

  • @DLTX1007
    @DLTX1007 11 років тому

    Be careful about the high res range, it's x10 the counts accuracy range

  • @drpsht
    @drpsht 11 років тому

    you mixed up the MOVs and PTC again, Martin. :) That next to the power resistor is the PTC, the other 3 are MOVs. BTW, I'm waiting for a forum account approval for a month now, what's going on?!

  • @rolandtutorial3377
    @rolandtutorial3377 4 місяці тому

    Ilike that 😊

  • @chrispychickin
    @chrispychickin 11 років тому +1

    Look closely at the screen as martin pulls off the screen protector, digits get illuminated by static charge. Kind of ironic considering the overall design of the meter ;)

  • @movax20h
    @movax20h 6 років тому

    How it can be intrinsically safe when it has high current amps measurements. In theory you could have leads accidentally in current sockets, and then connect to measure mains voltage for example, and create a spark on leads contact. I do not like it.

    • @Die-Spezialisten
      @Die-Spezialisten Рік тому

      The housing is completely water and dustproof. Also the fuses. So a spark can´t get out.
      The manual says: in ex zones you may measure with max. 5A and 65V

  • @mikeadler434
    @mikeadler434 2 роки тому

    👍👍

  • @blakebuchanan1420
    @blakebuchanan1420 5 років тому

    a lot of use of "obviously" when reviewing something not obvious

  • @thomasleerriem6872
    @thomasleerriem6872 7 років тому +1

    I'd never put duracell batteries in my gear. They're notorious for leakages. Apart from their overrated price, they'll cost you even more by damaging your stuff.

    • @bouipozz
      @bouipozz 3 роки тому

      I just ordered one of these meters... and a pack of Procell batteries to go with it haha. Do you have a preferred brand?

    • @Die-Spezialisten
      @Die-Spezialisten Рік тому

      I experienced it. My meter is dead. The gases get into the electronic section and destroy it.

  • @keramzytowymocarz7104
    @keramzytowymocarz7104 2 місяці тому

    what a dush strip sticker