  • @grumss9248
    @grumss9248 3 роки тому +4

    Being an Instrument tech, i smiled a bit whilst you were trying to explain some of the principles to those that dont know :) We have been using these meters for many years, perhaps their biggest weakness is that the banana jacks tend to break with our industrial use, otherwise a very handy meter and an industry standard here in Aus. Great review

    • @sergiobenton7837
      @sergiobenton7837 3 роки тому

      you all prolly dont care but does anybody know a trick to get back into an Instagram account..?
      I somehow forgot my account password. I love any tips you can give me.

    • @louisduncan9434
      @louisduncan9434 3 роки тому

      @Sergio Benton instablaster :)

    • @sergiobenton7837
      @sergiobenton7837 3 роки тому

      @Louis Duncan thanks for your reply. I found the site through google and Im trying it out now.
      I see it takes quite some time so I will get back to you later when my account password hopefully is recovered.

    • @sergiobenton7837
      @sergiobenton7837 3 роки тому

      @Louis Duncan it did the trick and I finally got access to my account again. I'm so happy!
      Thank you so much you really help me out !

    • @louisduncan9434
      @louisduncan9434 3 роки тому

      @Sergio Benton you are welcome :D

  • @johnolivares
    @johnolivares 4 роки тому +1

    Great video, man!
    I'm used to work using 789 and this is the best video i've ever seen explaining its functions and functionalities

  • @andyandy7968
    @andyandy7968 3 роки тому +5

    5:35 you cannot switch from DC to AC because you have no leads connected. This meter has internal test leads detection circuit and by default it expect that you connected to middle (DC) output.

  • @Alexander_Sth
    @Alexander_Sth Рік тому +1

    Hi! You are using rechargeable batteries, however Fluke doesn’t recommend it because there are 1.2v instead of 1.5v. They told that it could influence on the correct accuracy.

  • @sidsybounheung7774
    @sidsybounheung7774 9 місяців тому +1

    How to change current from0am-20am to 4am-20am

  • @juliocesardealmeida2167
    @juliocesardealmeida2167 Рік тому

    Great video! So good!!!

  • @DarlingMarco-rg2vx
    @DarlingMarco-rg2vx 11 місяців тому

    Hi good day! I have question, my fluke 789 spark when i test the voltage ac of a motor, the selector is in voltage Ac, but the test jack was in mA. Will it damage the fluke permanently ? 😢

  • @charlespereirapedro461
    @charlespereirapedro461 3 роки тому +1

    Good afternoon friend how do I change the scale from 0 to 20mA to 4 to 20mA?
    thankful.

  • @jacka.4774
    @jacka.4774 4 роки тому

    when you popped the battery lid open, for a second I thought I was looking at my own 789. I have the exact rechargeable batteries and just changed them. Here is a question I was hopping you would answer, On mine all of sudden the digits went away. and did not come back on. it would turn on just did not display any digits. when changed the batteries digits came back on. does that tell me the battery is low?

  • @ronrosario6763
    @ronrosario6763 3 роки тому

    Evione it's really great your vedio so I have some issues with simulate its doesnt show reading cos I fuse was blown as I forgot to change the probe it was on sale 4-20m.and small spark after tat I replace fuse but now wen I want set some liquid level transmitter it doesn not shown the reading is it cos some testor issues pls advice me

  • @danhealey7320
    @danhealey7320 4 роки тому

    Good video and thanks for the info, at about the 16:10 mark you measure approx 31 VDC, when the 789 is in source mode. Where are you taking the measurement from? regards Dan.

    • @cobelali
      @cobelali 4 роки тому

      That is the voltage the Fluke is outputting through the source connection. The output of the Fluke is connected to the current input of the red multi meter. He changes the connection on the red meter to read voltage.

  • @lancerudy9934
    @lancerudy9934 4 роки тому

    Will the meter drive a valve open or closed?

    • @grumss9248
      @grumss9248 3 роки тому

      It will drive the "control signal" and open and close the valve...BUT Most valves will need a secondary power supply being air or electricity..

  • @CharlesSelva
    @CharlesSelva 4 роки тому

    how i do check number of calibration on fluke 789?

    • @user-bg9rc1sx1s
      @user-bg9rc1sx1s 3 роки тому

      With holding a hold button, turn to ohms, press hold one more time and you will see how many times meter was adjusted

  • @danylieto5222
    @danylieto5222 4 роки тому

    What is the importance of source and stimulate and at what condition we will use?plz show the ckt connection

  • @lancerudy9934
    @lancerudy9934 4 роки тому

    What do you mean by source?

    • @grumss9248
      @grumss9248 3 роки тому

      Means it can become the source of the signal (ie can send out 4 to 20mA to an external device)

    • @grumss9248
      @grumss9248 3 роки тому +1

      Most industrial instruments use 4 to 20mA (current) as control signals..... A voltage signal is affected too much by voltage drop in most plants due to the instruments being remote.. The signal starts at 4mA, below 4mA suggests to the control equipment that there is a fault in the circuit.

  • @tonytromp6794
    @tonytromp6794 Рік тому

    Mooi verduidelik, dankie!!

  • @LovelyDoetje
    @LovelyDoetje 4 роки тому +2

    Ramp options are: slow, fast, 25%step slow, 25%step fast. If you had more patience you would have seen it.

  • @ysamuelarai
    @ysamuelarai 5 років тому

    "Of course" is overused.

  • @tonytromp6794
    @tonytromp6794 Рік тому

    Hey, jy moet nie bubbles hap nie jong!