HOW TO REPLACE A JACUZZI HEATER.....The SpaMan will show you how.... Arizona Hot Tub Factory

Поділитися
Вставка
  • Опубліковано 6 вер 2024

КОМЕНТАРІ • 25

  • @PaulPatMcGarry
    @PaulPatMcGarry Місяць тому

    Thanks so much for making this video. We were able to change out the heater and are now back in business!!

  • @billiamc1969
    @billiamc1969 11 місяців тому +2

    Much respect from Baltimore. We just started to heat the hot tub back up to 102F as the weather FINALLY cooled off and now I am back to soaking 2 times a day

  • @byronhadley9662
    @byronhadley9662 11 місяців тому +2

    It’s cool to see you make mistakes and keep them in the video!

  • @DolphinDancer-nk9tw
    @DolphinDancer-nk9tw 3 місяці тому

    Hey Scott Miracles of miracles. Looked last night Jacuzzi temp up to 101 degs. Same this am so I guess it fixed itself But I'll keep your how to in mind Thanks Karl

  • @josephgraham1065
    @josephgraham1065 11 місяців тому +1

    Another great video. I have a Sundance and was wondering where the heater is .... Now I know... Thanks

  • @DolphinDancer-nk9tw
    @DolphinDancer-nk9tw 4 місяці тому +2

    Hey Scott Great video I probably could do this myself. Still would be good if you know of someone in San Diego that could do it Thanks Karl

    • @spaman5440
      @spaman5440  3 місяці тому

      Wish I could help with that... Thanks for Watching & SUBSCRIBING

  • @brianbanks3044
    @brianbanks3044 11 місяців тому +1

    i did a similar repair a few months ago on my J-325...luckily I didn't break any fittings but i pretty much did it like you did and didn't lose more than 12 ounces of water

    • @spaman5440
      @spaman5440  11 місяців тому

      That is awesome..I love hearing stories like that from the viewers .. Great Job.. Thanks for Watching & SUBSCRIBING

  • @BraveHelios
    @BraveHelios 8 місяців тому +1

    Hey Scott, this is Tony from Idaho. We spoke a couple of weeks ago about my Tuff Spa. I have a no heat issue. Recirc pump works. I have 240 volts going to the element and disconnected the element wires and checked resistance on the 4 kw element. It has around 2.5 k ohms. I then connected everything back up and checked the amps. I believe the 4 kw element should draw around 20 amps but my meter only read 0.178 amps. Is this enough information to conclude that the element is bad and needs to be replaced? Thanks!

  • @joshsteele5488
    @joshsteele5488 6 місяців тому

    Ahoy Scott, J-365 model jacuzzi. Breaker started tripping. After disconnecting the power to the heater, I found that’s what it is.
    Just replaced the heater, but the breaker is still kicking. I found now that it seems to be the circulation pump. Once I unhooked the power from it, breaker stops tripping. But when the electric is hooked back up to it, the breaker trips as soon as the circulation pump kicks on.
    I just replaced that circulation pump a year ago though.

  • @oscarochoag82
    @oscarochoag82 10 місяців тому

    Congratulations on your channel, I am a fan of your videos, you are a professional and excellent instructor. I have a HotSpring Jetseeter. When I turn on the jets I hear repeated clicks on the relays. I left the jets on for about 5 to 10 minutes and they stopped working, I checked the voltage (120v) and it was fine, the next step I did was unplug the pump and check if it was working and really if it is ok... I wonder if this is a problem with the relay board or the main board.... I hope for your help

  • @user-bw3nz9nk4t
    @user-bw3nz9nk4t 9 місяців тому

    Thank you
    Благодаря вашим видео смогла отремонтировать свой спа.

  • @w.r.6019
    @w.r.6019 7 місяців тому +1

    Jacuzzi J365 that is leaking from the heater area, a victim of freezing weather. What is there that can be effected by freezing temperatures? The weather is suppose to be better next week so will be able to work in it but I really need to know what to look for before I order a whole new heater. Thanks. Your video was fantastic!

    • @spaman5440
      @spaman5440  7 місяців тому

      I would call Scott. There are several factors that come into play when dealing with a hot tub that is leaking. Like does the heat work or not work is it full of water or is it empty with very little water in the lines.All of these thing has a different effects on what the path to getting it fixed will be.. Thanks for Watching & SUBSCRIBING

  • @antonellaluna3595
    @antonellaluna3595 11 місяців тому +1

    Hi! I have a jacuzzi j series, Fl 1 message showing…replaced sensor flow, pump 1 , heat sensor, circuit board, did the hose on the filter..new filter.. fl1 still showing and pump 1 wont start..help!! Please 😩

  • @alknight1675
    @alknight1675 10 місяців тому +1

    Great video! I was wondering about the old clear hoses and was worried about getting them off. Heat gun is the solution! Question, do you have to drain the hot tub before doing the heater replacement?

    • @spaman5440
      @spaman5440  9 місяців тому

      Yes the heat gun is the secret... and I always empty the Hot Tub to replace the Heater. Thanks for Watching & SUBSCRIBING

  • @user-el3xe3zz6y
    @user-el3xe3zz6y 11 місяців тому +1

    I did not see a way to contact you with a question. I have been trying to solve a watchdog error on my Sundance Chelsea 780 series spa. The last time it happened following start up I noticed that the flow valve was extremely hot (150 f). Determined with a digital heat sensor (gun). The water was only 96 f. I'm assuming that the temp of the flow valve is what caused the watchdog error. Your thoughts on this would be greatly appreciated.

    • @spaman5440
      @spaman5440  11 місяців тому

      If you are not moving water through the heater were the sensors are located and the water around the heater is heating up you may receive a false reading... the cir pump should come on the min the breaker is turned on pushing water past the heater then flow switch and back into the tub if it is all working properly then I would mov on to the sensors in the tub to make sure they are working also if all that checks out then most likely you have a software issue and the board would need to be replaced. Hope this Helped
      Thanks for Watching & SUBSCRIBING

  • @jackiefolio1559
    @jackiefolio1559 11 місяців тому

    What size brass fitting did you use? Also, what size diameter was the clear piece of hose you replacrd? Thanks!

    • @spaman5440
      @spaman5440  11 місяців тому +1

      The brass fitting was a 1/4 by 3/8 and the hose was a 1/2 inch

    • @jackiefolio1559
      @jackiefolio1559 11 місяців тому

      Thanks soo much. Love your videos!@@spaman5440

    • @jaredwhite-music
      @jaredwhite-music Місяць тому

      @@spaman5440 Are you positive? I've slowed the video down, and it looks like it is a 1/8 MPT x 5/16 In. It's really hard to see in the video. Will either work?

    • @spaman5440
      @spaman5440  29 днів тому

      @@jaredwhite-music I know what mine was yours could be different. They make more then one and I've seen several different ones over the years