Dc Inverter Air Conditioner When Compressor Starts But Fan Motor Not Works | AC Pcb Repair | Fujitsu
Вставка
- Опубліковано 2 тра 2021
- 💡 Join Us On Patreon 👉 bit.ly/3vMga6S
💡 Subscribe To Get All FREE Videos 👉 bit.ly/3MMozxd
_____________________________________________________________
💡 Subscribe Forever Tech Shorts Channel 👉 bit.ly/3gL5vQz
💡 Subscribe to the English Channel 👉 bit.ly/3pzBLvh
Social Media Links
💡 Facebook 👉 bit.ly/3hTPHvY
💡 Instagram 👉 bit.ly/3oJcwDm
💡 Twitter 👉 bit.ly/3atkbRl Dc Inverter Air Conditioner When Compressor Starts But Fan Motor Not Works | AC Pcb Repair | Fujitsu
Subscribe ▶ bit.ly/2Xj8JkN
Subscribe 2nd Channel ▶ bit.ly/336lCSz
Popular Video ▶ bit.ly/3nGjlGH
Previous Video ▶ bit.ly/3bgdTpt
Hello Guys It is Great to see you again on our channel forever tech we hope you always support our efforts because we can not run this channel with out your support good luck and have a nice day.
About this Video
In this video we have repaired an inverter air conditioner whose compressor starts and works properly but its outdoor fan motor is not starting and working so we have repaired this issue of o general ac or fujitsu ac with complete information and detail in this video.
Social Media Links
..................................................................................
Facebook ▶bit.ly/36FbFgP
.....................................................................
Instagram ▶bit.ly/3oJcwDm
....................................................................
Twitter ▶ bit.ly/3atkbRl
......................................................................
Our Other Videos
Air Conditioner Basics/ Hvac basics Playlist
▶ bit.ly/36GtfRQ
Compressor Testing Playlist
▶ bit.ly/36JgkOZ
Automatic Washing Machine Repair Tricks Playlist
▶ bit.ly/3rj7Dmc
Dc Inverter Air Conditioners PCB Repairing Tips Playlist
▶ bit.ly/2YPIrr7
Electronic Component Testing
▶ bit.ly/39MQdbP
Washing Machine Basics
▶ bit.ly/3t9AGt7
Refrigerator Faults and problems
▶ bit.ly/3tcYE6D
.......................................................................
#forevertech #ac #airconditioner #ogeneralac #inverterac #dcinverterac #fujistu #compressor #fanmotor #dc
Friends Do Share this Video With Others As Well And Hit the Like Button....
And How Did You find this information do Comment for that
Really good video. You Know a lot about Inverter Sistem, thank you so much from Venezuela
Beautiful information.
Wow very nice video 👍
Thank you sir.
Sir apse ek req hai ap bht lambi detail btate hn sir
Sir you always sharing authentic videos
Thanks vai ❤❤❤❤❤❤🇧🇩
Good job
Nice bro best of luck
thnkyou sir
Nice
good Nice
Bahot mehnat karke video banate h aap thanks
Sir namaste. Sab voltages sahi ane ke bavajud kyu in components ko change karna pada sir. Plz reply sir
great video,I have the same board but it works then cut off and it is communication problem,how to fix that.
Very good video.
Thank you very much!
Great sir,
thanks
❤❤❤
PCB ka all component check karne ka tarika ka is video ek banaen sir
Properly Full Testing And Folt components Changing at Show The UA-cam channel . First Point:- digram is perfect next second :- testing is ok but last Faulting Components Change Not Show .
Salam
Brother ap kaha say ho
Aslaam o alaikom sir g outdoor unit mean compressor pr jo kapdra hot hai wo hona chahiye ya nahi or wo compressor k liye fade mand hai ya nai zara mehrbani se information de den aap ki bari mahrbani ho ghe
Sir iski indoor cercuit ki power supply ke reapairing btaiye
😊😊😊
Nadeem from Saudi Arabia Sir electronics frig ka on position main heater check kernain ka treeka Bata dain
asalamu alaikum. sir aap ke video dekhta houn, DAIKIN INVERTER AC 1.5 LATEST OUTDOOR KA FAN AUR COMPRESSOR START HOTHA 30 SE 45 SEC MAIN OUT DOOR KA FAN OFF HOJATHA HAI OUTDOOR SENSOR CHANGE KARE; PL REPLAY
Mumbai hai kya sir apka service
Bought Forbes inverter AC on 2019 , just few months used given my flat for rent. Then on march 2020, my flat home is vacant till now.. now today went there to my vacant flat to check AC, stabilizer shows 245, them AC indoor unit is running, no cooling air , about 7 minutes later, shuts off and shows E1 in display. By remote control, i checked with off, display shows nothing(off mode), then again by remote, switched ON , same E1 shows in panel display.
After sometime, again switched on the AC, went upstairs to know whether outdoor unit fan is running or not. Saw on outdoor unit, fan is not running. So actual problem by this outdoor unit only ? What to do next, to call authorised Eureka Forbes AC technician if it's warranty as i don't know...or have to search for local AC technician to solve this problem. Please help me?
Hum apki video skip kr dete hn q ky sir hum kit thek ni krty apki video kit thek krny walo ko faida dy ge hmain ni dy ge
I also have another one with this problem,i measure the cap are all fine,what is the problem?
Sir outr ki fan motor kbi rok jati hay kbi nhy amper 2.5 1.5 3.5 hojaty Hain cooling down hoty hay 10 15 ment KeY bad os say pehly 10.5 amper🎉 cooling fit hoty hay
Ok bro
Sir mein 1 month pehelay ek 2022 model whirlpool ka 1.5 ton inverter 5star inverter ac kharida huin. Ac acha cooling karta indoor blower regular acha se bhi chalta hai.
Per outdoor unit ka fan kuch second ya 1 mint keliye stop hojata hai fir auto start hota hai.
Per mera ac achasa cooling karta reheta hai..
Sir kiya mera ac kharab hai?
Pls replay me first
Tradução para o Inglês.😮
Nice video
Aap bhut acche se sajhate hai
Bahut kuch sikha hai apse
Sir ek o GENERAL inverter me kabhi 5 time blink hota hai kabhi 3 time kabhi 2 time timer led blink hoti hai
Kaha ka fault ho sakta hai ye
Dear 1 blink 2 blink aur 3 blink par hamare video already mojod ho aur 5 blinks bhi osi catergory mai aya hai
@@ForeverTechh sir I have find that fault
Now it's working properly
Assalamu aikum
Sir ham ny esi year kenwood k AC liya h 4 month ho gay. Sir ajkal jab us ko raat ko on krty hain 28C py to wo 2 hours k baad cooling kr k 2 ampire sy kam py aa jata h. Us wqt sir AC ki air mn sy smelll any lag jati hai mn ny outer ko b dika us k sir fan band hota h or room temprature chk kru to 26 hota h sir plz tell mn ya koi masla h es mn ya matloba temprter py aa k aasa krta h AC. Sir plz tell mn jazakAllah
emulate the control board of the inverter air conditioner cold head
Rajitensh 803 ke10 likha hai iska matlab kya hota hai sir 🙏
Sir mere pel dc inverter me f1 error aata hy lekin aksar bilkul theek chalta hy. Jab error aaye to kuch minutes off krne k baad theek ho jata hy. Lkn kbhi kbhi kafi tng krta hy. Jab chalay to cooling bhi achi krta hy... Koi temporary type issue hota hy. Kese solve ho skta hy?
Ustad ji mery ps Hitachi dc inverter h us k outr mai siply de raha hon to forn fuse ur jata h kya problem h
🙏🙏sir ji IFB ka inveter ac h light jane ke baad ye ac automatically on nhi hota remote se on karna padta hai kaya problem ho sakta h sir ji
Heair DC Ac 15 minutes outdoor on hta phr off ho jta phr 15 minutes bd on hta hai kia problem hai
Sir ji... Mery Voltas ki window AC me .. Temperature 🌡️ +. - . Set Nahi ho paa Raha he. What is the problem _Reason ... Coil sensor +Room temperature sensor Mene multimitor se check Kiya ... Ok he.. cooling is verry cool . AC condition is ok . AC Amp is 8.5
Dear sir jab fan k jack par. Voltage sahi aa rahe the to fir pcb repair kyu li
Please sir thora Aista Aista video ko Samjhaiea sir har video appka jaldbaji oure jhat pat kartea hai
Sir AP ka num ya shop ka address mil Jay ga
My AC TATA VOLTAS 18000 BTU invter outdoor unit not working . can you pls hellpe me
Sire mere ace me same yhie problem aa rahi
Same ac hai apka?
Motor working but compressor not working.1 se 2 minute tak chalta hai.uske bad bund ho jata hai.2 minute chalta cooling bhi karta hai.is fault plz batain
Jo bolan hain us se jayada edhar udhar q Bolton hai
Sir
Carrier inverter ac ka out door fan motor heat ho raha hai aur slow chal rha hai
Phir compressor overheat ho ke trip ho jata hai
Kya reason hai pls reply
Sir same problem mujhe aaraha hai kaise solve hua tha please bataye
Bol ne ke time itna Harvard q kartoon hain ap
Fan not working,replacing capacitor >>ua-cam.com/video/RT0pZLG6BFM/v-deo.html
भाई आप कहां के रेहने वाले हो मोबाइल नंबर भेजो
hello Sir,
hum ne 2019 ma gree AC 1.5 ton inverter (GS-18AGS-18AITH11S) purchase kia. 2020 ma iska panel/kit (PCB) jal gya.
hum ne last year isay Rs. 25000 ma purchase kia...
iss season ma AC start kia to ye kaam ni kr raha tha
electrician ko bulaya to pata chala k Mother board Compressor ko On ni kar pa raha... he said k mother board theek krna paray ga..
Aap kya advice krtay hain k hamay kya krna chaye
thanks
my whatsapp number is 03314203625
انورٹر ایس سی سولر پہ چل رہا ہے سب شام کو پانچ بجے سورج کی روشنی کم ہوتی ہے تو وہ ایف زیرو دکھاتا ہے اور ایک بجے تک ٹھنڈ زیادہ ہوتی ہے ان کے بعد ٹھنڈ نہیں دیتا ورک کر رہا ہے