Very good knowledge sir,..mere pass voltas 1 ton non inverter split ac me indoor unit band karne par outdoor unit ka fan band nahi hota bahot der tak dekha lekin band nahi hota kya fault hoga please bataye.
Achcha bhai yah batao ki Indore mein PCB Mein line a Raha Hai Magar flower Nahin chal raha hai aur outdoor Mein line Nahin a Raha doctor bhi nahin chal raha hai kya Mushkil Hai comment Mein batao Mere Bhai theek hai
Indore ke PCB mein check Karen Jo outdoor ke liye tar ja rahi hai vahan per supply a rahi hai ya nahin ya FIR out Dor wali wire mein koi jod to nahin hai aur check Karen wiring check Karen out Dor wali agar koi problem hogi to bahar hi aapko dikh jayegi nahin to out Dor ke PCB mein problem ho sakti hai
Split ac ko continue on off karne ke bad cooling deta Ek baar me on karke wait karta ho to cooling Nahi deta on of jiyada martaba karne ke bad colling deta aisa Kiya waja he
Outdoor wala wire check Karen aur agar warning sahi hai to outdoor per check Karen Jahan per wire laga hua hai vahan per voltage a rahe hain ya nahin aur FIR bataen
Mera voltas ka invertor AC ha iska outdoor unit kabhi kabhi chalte chalte band ho jata ha phir apne aap chalu ho jata ha. Aaj outdoor fan bahut slow chal raha aur cooling nhi ho rahi. Maine technician 2 baar bulaya wo jab aata ha uske saamne outdoor fan chalu ho jata ha samaajh me nhi aata kya karu
P0 ka indicator aa raha hai technician ko dikhaya to usne pcb ka problem Bataya fir pcb ko repair kar ke lagaya thi nahi hua ab bol raha hai voltage ka problem hai Lakin mera second ac chal raha hai
Out door not ruing old models checking first due capcitr ot contactef buring no checking ok comprss gas checking trmials checkinv maing ground no trmial condvit shoeing no body checking wird buring con frome bai see old dusyty pm unit pborx checkinv ok capciter old checkinv oneby checking gas smprd reparing dolved ok bsi jolly hvac
Same inverter AC..1month old...fan nehi chal raha hain...indoor chal raha hain..bt outdoor fan nehi chal raha hain...aur ek prblm..agar fan chal raha hain..indoor bandh krneke baad bhi outdoor fan chal raha hain...keya kare sir... cooling bhi kam kar raha hain
Sabse pahle iske wire check Karen koi wiring loose to nahin hai ya FIR koi wiring mein joint hai vah joint leak ho to bhi yah problem a jaati hai is problem ko communication error bolate Hain yani ki wire ka current jo hai out Dor per match nahin kar raha hai jiski vajah se yah dikkat aati hai
Sir good find out of advice, Ac remote me timer system me Reset kaise kare और विदाउट timer chala sake
Good sir ji ❤
Very good knowledge sir,..mere pass voltas 1 ton non inverter split ac me indoor unit band karne par outdoor unit ka fan band nahi hota bahot der tak dekha lekin band nahi hota kya fault hoga please bataye.
Sir chlte chlte outdoor or fan dono band ho jate h or indoor voice krne lgta h or cooling ni hoti ?
Same haal hmara hai 😢
Mere ac me bhi same yahi ho raha hai
Sir voltage km ya zyada hor ha tha jis ki vaja sa hamry ac ka outdoor nhi chal rha please is k ly kya krna ha?
Iske liye ac ke hisab se stabilizer lagaen
Humara 1.5ton ka ha haier company ka ha, but outdoor nahi chal raha ha, koi bata raha ha pcb kharab ha, thoda suggest kariye plz
Kaun si company ka hai AC aapka inventory non inverter
@Technicalsamayofficial , haier, 1.5 ton
Achcha bhai yah batao ki Indore mein PCB Mein line a Raha Hai Magar flower Nahin chal raha hai aur outdoor Mein line Nahin a Raha doctor bhi nahin chal raha hai kya Mushkil Hai comment Mein batao Mere Bhai theek hai
Indore ke PCB mein check Karen Jo outdoor ke liye tar ja rahi hai vahan per supply a rahi hai ya nahin ya FIR out Dor wali wire mein koi jod to nahin hai aur check Karen wiring check Karen out Dor wali agar koi problem hogi to bahar hi aapko dikh jayegi nahin to out Dor ke PCB mein problem ho sakti hai
Bhaiya outdoor ka compressor aur capacitor garam hota hai kya
Sir outdoor ka fan ek min chalta hai fir automatic band ho jata hai kya dikkt aa skti hai
Baut pareshan hai
रिमोट में अपने ड्राई का बटन तो नहीं दबा रखा है
❤❤👌👌
Split ac ko continue on off karne ke bad cooling deta
Ek baar me on karke wait karta ho to cooling Nahi deta on of jiyada martaba karne ke bad colling deta aisa Kiya waja he
Bhai meri dikin ki ac h. Uska out door nhi chal raha h. Or indor chala raha h. Kya dikkt ho gi
Outdoor wala wire check Karen aur agar warning sahi hai to outdoor per check Karen Jahan per wire laga hua hai vahan per voltage a rahe hain ya nahin aur FIR bataen
❤❤❤
ye split ac hai kyaa
स्प्लिट एसी का आउटडोर है
Mera voltas ka invertor AC ha iska outdoor unit kabhi kabhi chalte chalte band ho jata ha phir apne aap chalu ho jata ha.
Aaj outdoor fan bahut slow chal raha aur cooling nhi ho rahi. Maine technician 2 baar bulaya wo jab aata ha uske saamne outdoor fan chalu ho jata ha samaajh me nhi aata kya karu
Outdoor not working and temperature automatically gone to 36
Bhaiya mera ac 1.5tan ka hai carrier ka out door fan nahi chal raha hai kabhi kabhi chal ke ruk jata hai please Bataye
Jab outdoor fan ruk jata hai to use time Indore PCB mein kaun sa indicator show karta hai vah bataen
P0 ka indicator aa raha hai technician ko dikhaya to usne pcb ka problem Bataya fir pcb ko repair kar ke lagaya thi nahi hua ab bol raha hai voltage ka problem hai Lakin mera second ac chal raha hai
Carrier customer care se baat Karen aapki solution solve ho jayegi
Mere ac ka outdoor fan slow chal Raha hai capister bhi change kr liya....phir bhi....
Mera inverter ac outdoor se awaz aaii or band hogya chal ni raha breaker bhi band hogya tha kiya masla hai?
Outdoor me sply nahi aa rahi h sir ji😮
Mera outdoor direct to chl rha hai without indoor connect but jb indoor chlate hai to outdoor nhi chlta
Mera marq ka hai c1 pe compresor nahi chal raha hsi only 16 to 24 tk chal raha hai
Bhai ac me F2 error aa raha hai outdoor nahi chal raha hai sirf indoor chal raha hai koi solution bataye
Body me carent arahahe
voltas Invertor AC ka outdoor fan beach beach m band ho jata hai or Cooling bhi band ho jati hai to plz help kre ki kya problem hai?
Jis time band hota hai use time iski outdoor PCB per volt check Karen a rahe hain ya nahin
Mere ac ka outer fan nahi chal raha hai nere outer ka wire chek kiya to corent saply ho rahi hai
Kaun sa aisi hai aapka inverter hai normal
Sir inverter hai
Inverter
Outdoor fan nhi chal rha indoor chal rha hai kya kare
Kaun sa Ac hai aapka inverter ya non inverter
@@Technicalsamayofficialinverter
Same problem
Out door not ruing old models checking first due capcitr ot contactef buring no checking ok comprss gas checking trmials checkinv maing ground no trmial condvit shoeing no body checking wird buring con frome bai see old dusyty pm unit pborx checkinv ok capciter old checkinv oneby checking gas smprd reparing dolved ok bsi jolly hvac
Outdoor PCB mein problem ho sakti hai
Fan nahi chal raha hai
Communication error hai ya to iski wire kahin se loose hai ya FIR iski outdoor PCB mein koi Na koi problem Hui hai
Ac cooling kr rha h but bht jada smell kr rha h
सर्विस कब करवाई थी आपने Ac की
2 month hua h kharide hue
Outdoor nhi chal rha h but supply aa rhi h and indor pe E6 ka alarm aa jata h
Mera inverter AC hai voltas ka
इसकी आउटडोर पीसीबी में प्रॉब्लम है
@@Technicalsamayofficial outdoor PCB check kra di hai wo okay h
और कोई प्रॉब्लम नहीं है PCB में ही problem hoti hai तब E6 error आता है
Same problem mere v AC ka h
Outer 5min k liye chl rha h phir bnd ho ja rha h jbki indor work kr rha h
Kaun sa Ac hai inverter ya non inverter
Dry filter ka problem hai Sayed
Same problem hai
Non inverter hai
Mera ac outdoor nhi chal rha bahut jada garam kar rha hai compreshar
आउटडोर का फैन चल रहा है या नहीं
Same problem my 10days old godrej ac outdoor fan chalte chalte band ho ja raha hai aur indoor garam hawa fek raha hai kya problem hai sir g 😢
Inverter AC hai ya non inverter
@@Technicalsamayofficial
1.7 ton 3star inverter hai sir g 😭
Same inverter AC..1month old...fan nehi chal raha hain...indoor chal raha hain..bt outdoor fan nehi chal raha hain...aur ek prblm..agar fan chal raha hain..indoor bandh krneke baad bhi outdoor fan chal raha hain...keya kare sir... cooling bhi kam kar raha hain
Mere AC ka outdoor nahin chal raha hai outdoor ka pankha bhi nahin chal raha hai
Sabse pahle iske wire check Karen koi wiring loose to nahin hai ya FIR koi wiring mein joint hai vah joint leak ho to bhi yah problem a jaati hai is problem ko communication error bolate Hain yani ki wire ka current jo hai out Dor per match nahin kar raha hai jiski vajah se yah dikkat aati hai
Wire check kar liye condensar donon change kar diye relay change kar diya
Ismein supply check Karen Ac on karke agar ismein voltage Sahi a rahe Hain to fir iske outdoor mein problem hai
Inverter AC ka kaise hoga
Aap ka number milega kya sir, plz
❤❤
Mera inverter ac outdoor se awaz aaii or band hogya chal ni raha breaker bhi band hogya tha kiya masla hai?