Hi Friends,
I am Ismail Khan and all of you are most welcome in my UA-cam Channel Ideal For Technical
In this video I have explained about complete information about all sensors used in inverter AC.
there are so many types of sensors used in inverter AC such as ambient sensor discharge line sensor and suction line sensor in outdoor unit while room sensor and coil sensor are used in indoor unit.
inverter AC has a DC inverter compressor which runs always on variable speed by the help of PCB.
PCB gets massage from the unit by sensor to operate compressor on desire speed.
if there problem occurs in system so sensor conveys massage to PCB and PCB shows error on display.
I have also explained that how sensor works in inverter AC
Queries Solved:-
Complete Information About All Sensor Of Inverter AC
Complete Information Of All Sensor Of Inverter AC
Inverter AC Me Sensor Ka Kaam Kya Hai
Outdoor Unit Sensor Of Inverter AC
Work Of Ambient Sensor
Work Of Discharge Line Sensor
Inverter AC Error Code Kyu Show Karta Hai
Inverter AC Sensor Details
Inverter AC Temperature Sensor
Ambient Sensor
Discharge Line Sensor
Suction Line Sensor
Inverter AC Discharge Line Sensor
Working Of Sensor In Inverter AC
Hope you enjoy this video
Thanks
About The Channel:-
Dosto Mere UA-cam Channel Ideal For Technical Ke zariye Refrigeration And Air conditioning, Electricals, Electronics, Mobile, UA-cam Channel Aur Computer Se Related Technical Knowledge, Tips And Tricks Ke Saath Social Welfare Se Related Video Upload Kiye Jaate Hai
Videos Ko Dekh Kar Comment Zaroor Kijiyega
Watch My Other Videos :-
Compressor Is Running But AC Not Cooling
• Compressor Is Running ...
Purge ! How To Purge Air From Refrigerant
• Purge ! How To Purge A...
How To Fit The Valve On Refrigerant Can
• How to fit the valve o...
Double Door Refrigerator Not Cooling
• Double Door Refrigerat...
Big Fault Of Double Door Refrigerator
• Big Fault Of Double Do...
Window AC Leakage Test And Repair
• Window AC Leakage Test...
Frost Free Refrigerator Wiring
• Frost Free Refrigerato...
Wiring Of Refrigerator
• Wiring of refrigerator...
Less Cooling In Refrigerator
• Less Cooling In Freeze...
Damper Of Samsung Double Door Refrigerator
• Damper Of Samsung Doub...
How To Top Up Gas In Window AC
link:-
• Window AC Gas Top Up !...
Refrigerator Leakage Test
Link:- • Refrigerator Leakage t...
Song/Music :-
Song/Music Attribution Not Required Provided By UA-cam Library
Disclaimer :-
Copyright Disclaimer Under Section 107 Of The Copyright Act 1976,
Allowance Is Made for " Fair Use " for Purposes such as Criticism, Comment, News Reporting, Teaching, Scholarship And Research, Fair Use Is A Use Permitted By Copyright Statue That Might Otherwise Be Infringing
Nonprofit, Educational Or Personal Use Tips The Balance In Favour Of Fair Use.
Thank You So Much
#sensor
#inverterac
#idealfortechnical
Contact For Business Inquiries :-
ismail05ideal@gmail.com
very very good and easy way to explain the functions of installed sensors. Thanks you Khan sahib. Jeety raho.
Many Many Thanks To You Sir For Appreciation 🌹🌹💐💐
Bahar ka tempochar bar jane se sensor condraser motor ka speed kam deta he not fan ka motor
@IdealForTechnical sir agar enme se koi sensar kharab ho jaye to kya ac room thanda krega please reply
@@indianyouth189 nehi
Nice explain sir... continue inverter ac videos sir..and washing machine fridge etc inverter type
बहुत ही सुंदर ढंग से सटीक समझाया है भाई ने! जबरजस्त भाई को नमस्कार
इतना प्यारे कॉमेंट के लिए बहुत बहुत शुक्रिया 🌹
Very good style of sharing descriptive information , good video composition..
Keep it up sir....
Assalamualaikum sir Very Good information thank you so much Sir
Nice information
Top
👍👍
@@IdealForTechnicalsir agar enme se koi sensar kharab ho jaye to kya ac room thanda krega please reply
Bahut accha sir
Nice information sir
🎉 informative video. Thank you.
Thankyou very much sir apka
Sir Dry mode par Ac 3 Amp Se chalta hai aur Normal Coold Mode par Trip karta hai kya ye Sensor ki vajah se ho sakta hai ??? Aur ho sakta hai to konsa Sensor
Nice
Super explain
Sir Error code par video banadijiye plz!!!
Very good sir nice information 👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍
Inverter ac compressor not running ful speed in day time. At night time it runs properly. Which sensor is faulty? ( Ogeneral inverter ac 1.5 )
Check the ambient sensor in outdoor unit
Good 👍
Shawevj zaidi AC technician
Welcome 👍
Sir teeno senser bhr nikl dain tu Kiya Hoga
No..Technical leges..sadi bhasa me samjao
sir ODU ambient sensor is damaged can we put 15k instead of 10k? on inverter compressor? Thank you..
Hi bro...my Godrej 1.5 ton inverter model 5star ac....day time working good not problem.but night time and rainy time not cooling that time outdoor stopped....I can't understand...what is the problem please help me
It needs proper servicing
Mashaallah
sir agar enme se koi sensar kharab ho jaye to kya ac room thanda krega please reply
Ambient sensor pe mitti hone se bhi kya cooling am hoti hai
bhai jitna safty company deta hai otna fault bhi yahi inverter model me hota hai 😂
Hi sir mery gree 1.5 ton Inverter ac ma f5 error a gea tha mechanic ne compressor wala sensor pcb ma direct kar dea ha ab unit 9 amps la rha laga tar es ka koi hal bta dan please es se f5 error thk ho gea ha ac cooling b kar rha ha but current bht le rha ha
Assalamualakum kya ap bata sakte hai ke compressor ka discharge temp kitna rehna chaya. Gas 410 gas ka ya R 22 ya R134 ka
Why ac take excess amp in starting like 10 to 14 amp on low mode
कंप्रेसर के डिस्चार्ज सेंसर को कैसे पहचाना
I have Mega T3 1.5 Ton installed, its temperature sensor is not working, even at 28 degree cooling, it takes about 8 amperes current and the room temperature drops to 20 but its amperes do not decrease.
Remote ko reset kro cell nikal kr 3 ya 4 mnt baad dobara dalo or ac on kro h9 jay ga theek
sir our ac outdoor unit is not working properly sometimes its fan just stuck even when the ac is on and also ac is not showing any error message, i am from delhi temperature nowadays average 45 degree and ac is voltas 1.5 ton spilt invertor
Bearing or bush of the fan motor is faulty
So it will not work properly
Change or repair the fan motor
aslam o alikum bhai kese ha ap sir mere inverter a.c ha sir who cooling boht achi krta ha magar i thing ho inverter pe nahe convert hota is ka kya masla ho skta ha kindly help kr de
P8 error ifb ac main kya problem ho sakti h
Gas Kam ho sakti hai
Lg split AC inverter compressor speed nahi badh rahi gas poori hai kya karen konsa sencer kharab ho sakta hai yan pcv mai problem hai?🤔
Sir mera naya samsung fridge ke niche bahar touch karu toh pani hain??
Diagram me wiring dikhao sir
T5 sensor kya hota he sir?
Sir aap kya online kochig padate ho
Baarish aane par ac me error aa jati hai to kya kare
avorator coil sansor konsa hota hai
Indoor unit me do sensor hote hai
Ek evaporator ke saamne Jo room sensor hai aur doosra coil se touch rahta hai usko coil sensor kahte hai
@@IdealForTechnical Electrolux inverter e5 de rha hai kya masla hai iska
Amazonbasics inverter ac me E6 code aa raha hai. Kaise theek karein?
Sir aap reply nahi karte whatsapp msg ka.
Khride kahan se
AC fridge ki spare parts ki shop se
hi, my inverter aircond, compressor failed to consistently pump maximum. it will drop and pump maximum again in not more than a minutes and keep on running high and low. During running in good condition, the compressor will pump high until temperature drop then compressor will decrease the speed. What sensor is faulty
Bakk
Nambar sand
Nice
sir agar enme se koi sensar kharab ho jaye to kya ac room thanda krega please reply
sir agar enme se koi sensar kharab ho jaye to kya ac room thanda krega please reply
Ac off ho jayega to cooling kaise karega
@@IdealForTechnical thanks sir