Inside look - Growatt 12000T 12kW and 6000T 6kW 48V 120/240V Inverter

Поділитися
Вставка
  • Опубліковано 6 вер 2024
  • An inside look at a Growatt DVM SPF 12000T MPV (7kw Solar input - 2 x 3.5kW - at 250Vdc 2 x 60A MPPT) and a Growatt DVM SPF 6000T MPV (5kW at 250Vdc - 1 x 100A MPPT)
    sales and support at watts247.com

КОМЕНТАРІ • 44

  • @OffGridandOutdoors
    @OffGridandOutdoors 2 роки тому +8

    Any possibility of a more detailed review of the 12kw? Seems no one is talking about these.

    • @_a1001
      @_a1001 2 роки тому +2

      I've been running the 12k model for about a year (purchased through Ian) and it's been solid. It really is heavy, but the auto transformer is worth it. On average, we use about 25-30kWh/day through the 12k, up to 50-60kWh/day in the summer.
      Honestly the only downside is you can't parallel it, and the wifi card isn't built in like some of the MPP Solar units, which took me a few tries to get set up, but is working now.

  • @larrybell4599
    @larrybell4599 11 місяців тому +1

    Ian, you’re ruining my dreams. I specially asked if the 6000T is a low frequency inverter. Are you telling me that it is Not a low frequency inverter, but a high frequency inverter with an auto transformer in order to supply split phase power?
    Now you tell me that it can’t be paralleled. That would have been priceless information when I asked to buy a second one. .

  • @alexnoff6284
    @alexnoff6284 Рік тому +4

    Hi Ian. Two questions: Did you bond ground and neutral in the subpanel witch inverter feeds? Did you run a neutral from main panel to subpanel to have a common neutral? Thank you.

    • @josesantiagosanchezsanchez3154
      @josesantiagosanchezsanchez3154 Рік тому

      I have been asking and investigating no one seems to answer that question ❓❓❓ I'm only off grid... should I bond them in the panel or just run a ground cable separate to a rod...

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 2 роки тому

    HOWdy I-S-P,
    Thanks for the LOOK inside
    COOP
    the WiSeNhEiMeR from Richmond, INDIANA
    ...

  • @christopherstaples6758
    @christopherstaples6758 8 місяців тому

    such a same no parallel mode i rather multiple smaller units especially when your talking about something 80kg , what Mosfets are in these the 150v input is quite low compared to other inverters its a tuff one when 4x panels are just a tad over voltage

  • @Sovereign_Citizen_LEO
    @Sovereign_Citizen_LEO 2 роки тому

    That LF transformer is massive. You should put a link in your description to your business. I thought the 6000T or smaller (4000T, 5000T) can be paralleled? I bought the 6000T (though haven't even installed it or tested it yet), and was planning on getting another to parallel them. I guess I didn't do my homework.

  • @marksorel800
    @marksorel800 2 дні тому

    is it possible ti connect 3 of these inverters together ?

  • @russbritt4100
    @russbritt4100 9 місяців тому

    How's it running now at the end of 2023? Signature solar dropped it for a few reasons one being reliability

  • @ozzlopez8605
    @ozzlopez8605 2 роки тому

    Are you familiar with what could cause code 56 and 4, battery voltage its code all the way to inverter, even inverter detects voltage but gives me those two codes, same problem in two (2) growatts 3000

  • @cwhjr7719
    @cwhjr7719 Рік тому

    which one of those boards is the MOV board in the 12k inverter ??

  • @itninja2716
    @itninja2716 2 роки тому

    if it is an inverter/ charger can a portable generator hook up to it and be used to charge 48-volt battery bank.

  • @plojm123
    @plojm123 Рік тому

    Can you charge with ac input 120v generator by chance? have you ever tested I know manual says only input 240v but I didnt want to buy another generator

  • @rickyrusselburgusa8644
    @rickyrusselburgusa8644 2 роки тому

    What size is the copper that goes to the lugs?
    Just found your channel too!

  • @robertomuhammad35
    @robertomuhammad35 Рік тому

    Hi . Please Which best battery brand and capacity to install with my 12kw hvm growatt.

  • @armandorivas3581
    @armandorivas3581 Рік тому

    Where can I buy control board for this inveter or for 6kw inverter?

  • @tomr5121
    @tomr5121 2 роки тому +1

    Hi Ian, do you know the idle consumption on these units. I've heard around 150w but it would be nice for some confirmation. Thanks

    • @JM-yx1lm
      @JM-yx1lm 2 роки тому +1

      Just at idle yes but once you put it to work doing something there is no idle draw

    • @northlander1948
      @northlander1948 2 роки тому

      I’m also wondering this.

  • @kevinsimth6548
    @kevinsimth6548 Рік тому

    hey how are doing i am trying to find a control board my growatt spf 8000t dvm

  • @bigblockcutlass123
    @bigblockcutlass123 2 роки тому

    I need to buy the spare board for my 12K

  • @SyberPrepper
    @SyberPrepper 2 роки тому

    I bought a Growatt 5000es with a transformer, but I probably should have purchased this low frequency 12KW unit (for the U.S. market) instead.

    • @sh839c
      @sh839c 2 роки тому

      Agreed.

  • @Fritsvrolijk
    @Fritsvrolijk Рік тому

    Is the Growatt stil working fine ????

  • @electromechanicalstuff2602
    @electromechanicalstuff2602 2 роки тому

    Can it start a home central ac unit?
    1.5 ton?
    12000t
    Just bought a mpp lv6048
    If I buy 2 will they start a 1.5 ton ac unit?

  • @richeagleton5285
    @richeagleton5285 2 роки тому +1

    I run it in my house akso I was going to make a video on conect in everything

  • @450kman
    @450kman 2 роки тому

    Ian, how sure are you that this inverter utilizes an autotransformer? Do you have any information from Growatt confirming this?

    • @ashforkdan
      @ashforkdan 2 роки тому +1

      Did you not see the size of the transformer?

  • @niktak1114
    @niktak1114 2 роки тому +1

    Can you test their 3x power surge capability?

    • @sh839c
      @sh839c 2 роки тому +1

      Yes, this would be good to know for people with deep well pumps. I doubt that the transformer less unit could handle those loads that's why I am looking at the heavy transformer models.

    • @niktak1114
      @niktak1114 2 роки тому

      @@sh839c I tested my 3HP 240V well pump with my LVX6048 recently. Started it easily.

    • @sh839c
      @sh839c 2 роки тому

      @@niktak1114 that is promising, how much battery do you have? I will just be using batteries for emergency water for now.

    • @niktak1114
      @niktak1114 2 роки тому

      @@sh839c about 10kwh usable. The only issue with this particular inverter is that it doesn't have a power save mode so it wastes a lot of energy if the only thing it will be used for is a well pump that pumps a few times an hour.

    • @sh839c
      @sh839c 2 роки тому

      @@niktak1114 Thanks. Which one does not have a power save mode, the Growatt or your LVX6048?.

  • @tsp2jxd
    @tsp2jxd 2 роки тому

    What is minimum battery size for using 6kw version?

    • @JM-yx1lm
      @JM-yx1lm 2 роки тому +1

      In the manual it says 300ah I believe.

    • @sh839c
      @sh839c 2 роки тому

      @@JM-yx1lm So just 3 100amp hr batteries for full output, for an hour?.

    • @ashforkdan
      @ashforkdan 2 роки тому

      I use 50.000 watts a thousand eighty amp hr.

  • @Tech4UbyJames
    @Tech4UbyJames 2 роки тому

    Has anyone bought anything from 24/7watts?

    • @ghiahzzzz1891
      @ghiahzzzz1891 2 роки тому

      Yes, shipped next day, Super guy

    • @larrybell4599
      @larrybell4599 Рік тому

      I did and Ian is great and he also answered questions after the sale. That is rare now days.