3 phase motor test

Поділитися
Вставка
  • Опубліковано 13 гру 2015

КОМЕНТАРІ • 240

  • @berkotropia
    @berkotropia 3 роки тому +4

    You always bring light into my brain! Thanks for that! The people who work with you are probably the luckiest people in UK

  • @wiserdaley2191
    @wiserdaley2191 4 роки тому +3

    You are just perfect in teaching. My gosh I wish other teachers would take a page from your book so they can stop teaching like you're making scrambled eggs.

  • @matthewmeuleman3369
    @matthewmeuleman3369 4 роки тому +6

    Nice way to test motors with special equipment!
    I like your explanation about insulation molecules, I have experienced a climbing IR value before. Electrical teachers normally just tell you to pee on something to help with continuity values, they never mentioned holding an IR test.

  • @gibbyrockerhunter
    @gibbyrockerhunter Рік тому

    I’m so glad I found this channel. Believe it or not I was wanting a “how to” video buy someone who knows a little more then if the multimeter beeps or not.
    In the words of G. Marx...
    I thankque!

  • @michealplater9007
    @michealplater9007 2 роки тому +1

    Yes. star/delta, 6 wires back to a starter, connect in star or delta depending on your supply voltage. Also each winding has a start U1,V1,W1and finish U2,V2,W2 mix them up and your in trouble. Normal practice is to bring the start out of the motor together and finish out together.

  • @laworder6092
    @laworder6092 4 роки тому +3

    Thank you sir for your generosity I appreciate it, I work with some plonkers when it comes to see how they do installations they send me to get coffee for them!!!and this happen all the time.

    • @demohmand
      @demohmand 4 роки тому +3

      That's terrible of them! I hope you get to work with nicer people who value you as an equal member of the team. All the best!

  • @reissner1967
    @reissner1967 5 років тому +5

    I had a motor come back from being “rewound” and one set of windings was mislabelled. U1 & U2 were backward. This caused the motor to draw about 185% of full load current. The motor ran slow and erratic with no load. I found the winding that was backward and relabelled it and tried it again and it only drew less than 40% of FLA with no load on the motor. Finding the three windings is the first step, then you have to find which ends are U, V & W 1 and which are U V & W 2 because when they are wired up they form a phaser diagram for current. Each should be 120 degrees apart. If a winding is backward, one current will be between the other two on the short angle. Let’s say all windings are okay and the currents are 100 A at 0 degrees and the second is 100 A at -120 degrees and the third is 100 A at +120 degrees. If the third winding was wired backward because it was mislabelled, then the currents would be: 100 A at 0 degrees and the second is 100 A at -120 degrees and the third is 100 A at -60 degrees(+120 degrees - 180 degrees). If you plot them you will see why the current is so much higher at no load. If it was a perfect motor, the current would be 200%. If this still doesn’t make sense, plot the voltages and currents in each winding on a phaser diagram and reverse one winding and do the plot again to see the effect when you add the currents.

  • @wiserdaley2191
    @wiserdaley2191 4 роки тому +3

    This gentleman speaks like Magneto in X-Men. Nice British accent 👌

  • @tonyfrewin4822
    @tonyfrewin4822 7 років тому +58

    You would never set the six ends in this configuration. The top set would be moved one place to the right so vertical delta links didn't link both ends of the same winding. ( I know this was star but you just don't do that). Also should have explained that the ones and twos must be at the correct end. Instant burnt out motor if not. Without manufacturer data you can only assume that all 3 ends from one side are ones and all 3 from other end are twos. Also you don't run 6 ends back to the starter unless it's star delta. You did say for delta. You also said contractors change from delta to star, this would be the other way round in star delta situation.
    The order for terminal posts could be / top row , W1/U1/V1, bottom row U2/V2/W2. So giving two different winding ends to each vertical pair. ie. (w1/U2) ( U1/V2) (V1/W2).
    I know there is a lot of good info here but there is also a fair bit of confused info here that will baffle learners.

    • @michaelcostello6991
      @michaelcostello6991 7 років тому +3

      Thanks very much for correcting stuff here. There was a lot of unanswered questions including the ones and twos which i still need more info on

    • @PURGE-3000
      @PURGE-3000 5 років тому +1

      Made perfectly sense.

    • @MountainBikers2015
      @MountainBikers2015 4 роки тому

      I picked up on all of these and I don’t understand why he is using cable instead of the normal plates! Also got me confused when he said that you must run back to a contractor for delta??
      Also even if your motor is on a inverter you still need the 1s and the 2s the right way round

    • @GymChess
      @GymChess 4 роки тому +1

      I was thinking the same thing, i.e., how to know which ones are 1's and 2's so to speak.

    • @KevinRocket01
      @KevinRocket01 4 роки тому +1

      quickly realized the wiring after he made the connection and immediately look on the comments to check if anyone noticed that too.

  • @vincentmasanja789
    @vincentmasanja789 5 років тому +1

    Thanks for your training.If you are talking about industry,you are talking about motors.

  • @bradjunes1610
    @bradjunes1610 2 роки тому

    Be back but sleep called----finish it tomorrow. Great video so far.

  • @pedrooropeza3527
    @pedrooropeza3527 Місяць тому

    Thank you for the information I like the way you explain the work

  • @simonevans7938
    @simonevans7938 4 роки тому +3

    Good video, but would have like to have seen you phase out the windings for Start and finish or 1 & 2 of each winding...before connecting in star and saying it would run correctly. Good chance a winding is in opposition to the other 2.

  • @DairyNZ
    @DairyNZ 8 років тому +16

    The large 3 phase motors I've come across are wired with the coils not aligned on the terminal block i.e W1-U2, V1-W2, U1-V2. This means you can wire them star or delta by moving the copper jumpers. Why would you wire this motor W1-W2, V1-V2, U1-U2? Is it not made to run in delta configuration? Wouldn't it be safer to wire it W1-U2, V1-W2, U1-V2 in case someone wires it into delta; to prevent a short circuit?

    • @MrCT2012
      @MrCT2012 7 років тому +5

      Yeah, I think it should be wire as what you said, U1-W2, V1-U2, W1-V2, so that easier for us to change the copper plate with vertical or horizontal directly for both Delta or Star connection respectively. But for Star Connection in this video, maybe he just don't care about that since it's for Star only, of course for safety consent, it should be like what you said.

    • @davidtan6873
      @davidtan6873 6 років тому

      MrCT2012 c

  • @chriskitcher
    @chriskitcher  7 років тому +8

    It is a Megger MIT 400. Very good piece of equipment

  • @angelinnasmith6368
    @angelinnasmith6368 8 років тому +35

    WRONG!
    1st. You should look at the terminal board, it should read U1, V1, W1, V2, W2, U2, not important in star only.
    2nd. What is difficult with 6 wires like that is to figure out which one is 1 and which one is 2 that have to be correct in both star and delta.
    3rd. On motors with light load there is no need for a star delta starter (they are becoming obsolete because there is many better ways to start a motor today), and you can start the motor in delta with a VFD
    4th. Even when you use a star delta starter it's nice to connect L1, L2 L3 on both top and bottom terminals

    • @MrCT2012
      @MrCT2012 7 років тому +1

      How to check which one is 1 and 2?

    • @honeydhiman2633
      @honeydhiman2633 7 років тому

      Angelinna Smith helooo

    • @TajulIslam-xv1xv
      @TajulIslam-xv1xv 7 років тому

      Angelinna Smith u r right

    • @sparky2464
      @sparky2464 7 років тому

      if u run it on two voltages it has to be connected for delta for the lower voltage. then it is very important to know which one is 2 or v1

    • @helixkatambo4675
      @helixkatambo4675 7 років тому

      what is the name of the device his using to measure the resistance and polarization of the Motor efficiency ?

  • @onyenekemichael4098
    @onyenekemichael4098 5 місяців тому

    What should be the range of accurate resistance values for eleçtrical 3 phase motors

  • @geneclemetson4779
    @geneclemetson4779 Рік тому +1

    In terms of U, V, and W wiring assignments, did you do that randomly? How did you know which letters to give to which wires? Is it a standard configuration ?

  • @yosh1don
    @yosh1don 3 роки тому

    Another excellent vid from Sir Kitcher

  • @emitwealth
    @emitwealth 6 років тому +6

    Really nice video. Please how do I know u1, u2, v1, v2, w1, w2? The issue here is the 1s and 2s. How do I know a 1 and a 2? Thanks.

    • @simonevans7938
      @simonevans7938 4 роки тому +1

      See my comment above. Its called phasing out and using the visual effect of Lenz's Law...Using a 6 volt battery and a anologe volt meter on 10 volt or less.

  • @24allnightmike
    @24allnightmike 4 роки тому +4

    where did you get that meter it's good that it megers the insulation

  • @jonskelton7433
    @jonskelton7433 Рік тому

    I have a motor I’m trying to identify the windings on, there is 12 connection, I can see there is 6 pairs. It was operating as 2 speed on the machine. I need to wire it at 2800 delta to connect a VFD, any idea how to identify which is which ?

  • @dgb5820
    @dgb5820 5 років тому +4

    Love that multimeter

  • @replicant357
    @replicant357 Рік тому

    Finally , the penny dropped , thanking you kindly ! 🙏🏻

  • @wowtech1310
    @wowtech1310 8 років тому +10

    how you assign u1 u2 , v1 v2 and w1 w2 ?

  • @lucyhaule108
    @lucyhaule108 4 роки тому +1

    the video is very helpful and easily understandable,

  • @sambathbunkh
    @sambathbunkh 6 місяців тому

    Very good explanation and video ❤❤❤

  • @alanmarriott9216
    @alanmarriott9216 2 роки тому

    Great video. Can I ask if you have a video or how you test Single phase motor. Sorry if its a silly question

  • @roger200921
    @roger200921 4 роки тому +1

    very good explanation.. but you mixed the start and the end of the coil in the terminal block. you just shorted..the wrong ends of the coil..

  • @TheManLab7
    @TheManLab7 6 років тому +4

    You didn’t check the polarity of the windings and the orientation to see if the motor runs clockwise or anti-clockwise.

    • @Wizowes95
      @Wizowes95 5 років тому

      Bet he had a reverse pole too 🤣

  • @paintballisawsome
    @paintballisawsome 5 років тому

    That terminal block is going to going bang if someone ran delta links. The Windings should be offset on the block not aligned with each other. IE if you connect three phases then each end of a link will connect 2 ends of A DIFFERENT winding. Its dangerous to connect a winding block to only accept star links where as offsetting the windings allows for either star or delta by just changing link configuration.

  • @hessammousavi500
    @hessammousavi500 4 роки тому +1

    how do you make sure which one is U1 and which one is U2? because if you connect them wrongly you will end up burning the motor.

    • @DipakFalane-es5ue
      @DipakFalane-es5ue Рік тому +1

      No it turn reverse

    • @hessammousavi500
      @hessammousavi500 Рік тому

      @@DipakFalane-es5ue no. If you do it wrongly it will burn the motor. One of the magnetic fields might be reverse compared to other two if you connect wrongly

  • @agdelig67
    @agdelig67 7 років тому +3

    what about voltage applied for insulation test 480 acv 13.8acv

  • @fidelcarlos9526
    @fidelcarlos9526 8 місяців тому

    and how did u know that coil is beggining leads and ending leads?

  • @bobbauvian7700
    @bobbauvian7700 2 роки тому

    thank you. this is perfect explanation. on my way to test a 3 phase, dual motor, compressor. its popping the beaker every couple of hours or so. I wanted to get a quick refresher. came to the shop to pickup the fluke scope, clamp and my old all-test. Usually i work on single phase stuff. when it gets to 3ph, mainly cuz I get to use my tools I get a little jittery and excited about it, hehehehe
    can polarization test be used on a single phase motor as well?

  • @josephksung
    @josephksung 10 місяців тому

    Thanks so much! What's the HP of this motor?

  • @MrWilsonVolleyBall
    @MrWilsonVolleyBall 5 років тому +3

    the successful way to get a big fire

  • @user-hv7rd8pf7n
    @user-hv7rd8pf7n 2 роки тому

    Why did you do the test with 500V ? Can we make it with 1000v ? And if it can be done with 1000v will we expect the same value after deviding the 10min and 1min ?

  • @xlvii6994
    @xlvii6994 2 роки тому

    the winding resistance value how do you know that you've got the right value?

  • @carloambisyoso_
    @carloambisyoso_ 3 роки тому +2

    How do you know which wire is U1 and U2 / V1 and V2/ W1 and W2?

    • @ef7480
      @ef7480 2 роки тому

      They are the terminals not the wires. The wires can be connected in different combinations. UVW (1) WUV (2) are the terminals.

  • @SABIRALI-gf3fv
    @SABIRALI-gf3fv 7 років тому +5

    you have nice digital ohmmeter.

  • @salmann94
    @salmann94 5 років тому +1

    at 9:30 you said that the polarization currents runs through the insulation because it could find paths through the un-aligned dipoles, but this is not accurate. The polarization current exists because of the time changing polarization density which induces the current. J = delta(P)/delta(t).

  • @MD-cd7em
    @MD-cd7em 6 років тому +5

    ON SOME MOTORS THE WINDING DESIGNATORS ARE MISSING..SO WHAT HE IS DOING IS CORRECT.

    • @s0m3th1n6s177y
      @s0m3th1n6s177y 6 років тому +1

      Furthermore, it is always best to know a complete method as opposed to relying on labels so this is a more useful methodology than is simply assuming designations are correct ad nausea

  • @CnormTV
    @CnormTV 3 роки тому

    Thank you and yes that meter is awesome 👌🏾

  • @mehul122
    @mehul122 5 років тому +4

    Excellent video, thank you so much!!

  • @theoblackadder8198
    @theoblackadder8198 7 років тому

    Great video, very concise and clear. I'm trying to run a three phase motor on single phase. Do you have any advice for a formula to determine capacitor size for optimum power and minimum heating? Thank you

  • @wasimedoo7994
    @wasimedoo7994 2 роки тому

    One question sir can I connect six 6 lead motor in star or delta for high an low voltage as 220 or 460 three phase please let me know thanks

  • @markb7692
    @markb7692 4 роки тому

    Hi, I can't understand why you didn't do an insulation resistance test from motor windings to earth, from the start of testing..... if there's a earth fault on the motor, why carry on.

  • @parol1519
    @parol1519 6 років тому +7

    PRO TIP: Set the video speed to x1.5 so the video takes 7.5 min.
    You're welcome.

    • @ericjohnstone5771
      @ericjohnstone5771 5 років тому

      If he had his coffee that wouldn't be necessary.

    • @vrexxter1750
      @vrexxter1750 5 років тому

      Lol yes the speed of UA-cam.

    • @reeb8587
      @reeb8587 4 роки тому

      i actually enjoyed the pace

  • @smooddawg9166
    @smooddawg9166 3 роки тому

    Do they have to be in that order? Like w1at the top w2 beneath etc

  • @dharamsinhmali9012
    @dharamsinhmali9012 4 роки тому

    Very nice video...
    Sir..

  • @outdoorsadrenaline
    @outdoorsadrenaline 6 років тому +3

    Good video mate, cheers!

  • @anjungantechnic4462
    @anjungantechnic4462 3 роки тому

    How much maximum value that winding at limit resistance? 1000 m ohm?

  • @dodznb238
    @dodznb238 2 роки тому

    Hello sir my dear new friend very good information..watching from philippines.👇👇👇👇👇👇🤝🙏🏼

  • @kennethlobo4420
    @kennethlobo4420 3 роки тому

    In the ten minutes polarisation test what are the units known as ( G) ohms, what does G stand for? Thanks

  • @YazidSG
    @YazidSG 8 років тому +1

    Good Information Thanks

  • @TheRecocebo
    @TheRecocebo 7 років тому +3

    Delta connection will not work. Also how do you know if a wiring is not swapped. I mean wether one of them will produce opposite magnetic field. Am I right?

    • @clems6989
      @clems6989 4 роки тому

      Yes your correct, he has no way to know which wire is which end of the winding..

    • @TheRecocebo
      @TheRecocebo 3 роки тому

      @Jack O'Bean also in star

  • @mmachwenepeo2055
    @mmachwenepeo2055 4 роки тому +2

    powerful explanations...thank you

  • @pbrown4
    @pbrown4 6 років тому

    does a 3 phase star motor need earthing? if so where?..what about neutral?

  • @chrisdodd4121
    @chrisdodd4121 6 років тому +1

    Hi there, I have recently discovered your excellent videos. I am just starting out in electrical maintenance. Could you recommend a good multimeter and megger. Also any other recommendations for testing equipment..... Many thanks

    • @mujisantoso7267
      @mujisantoso7267 3 роки тому

      multimeter = sanwa , megger tester = kyoritsu

    • @Pedro72740
      @Pedro72740 3 роки тому +2

      Yes. Pick a different field of work. 20 years from now you’ll be wondering how the hell you thought this shit would be cool to do for a living. Hot factories, grease monkey, product in every crevice of your body. Did I mention it’s hot! Shirt soaked every night. If you are lucky you will have a boss who won’t make you do project work while also running the floor fixing breakdowns. Emergency breakdowns are the worst. If there is an oven or many ovens in the plant - run! And don’t look back. Shoot! What the hell was i thinking!!!?

  • @sheldonstarling7068
    @sheldonstarling7068 Рік тому

    Can single-phase be turned into 3 phase power?

  • @GEEKICIDALTENDENCIES
    @GEEKICIDALTENDENCIES 5 років тому

    whats ment by a good "earth"? is it the same as a "ground"?

  • @kennethkristensen5537
    @kennethkristensen5537 2 роки тому

    What are the lowest insulation resistor you will recommend between earth and the winding?

    • @tehking111
      @tehking111 Рік тому +1

      Late answer but regulations say 1M ohm.

  • @janr.9035
    @janr.9035 8 років тому +2

    thank you so much... this is a very helpful video.

  • @alquiloscrisjanninog.6607
    @alquiloscrisjanninog.6607 5 років тому

    How much the resistance consider that motor is damage??

  • @tomesky
    @tomesky 8 років тому

    Do you have to do the polarisation test on each winding? Also where abouts is the earth wire in that terminal block? or is it just to the body of the motor somewhere?
    Also what about the neutral wire?

  • @goldfish5606
    @goldfish5606 3 роки тому

    What tester brand are you using

  • @JustaCuriousity
    @JustaCuriousity 4 роки тому +1

    Hi, thank you for such nice video. Whats your multitester model by the way?

  • @MaheshBabu-jb2hz
    @MaheshBabu-jb2hz Рік тому

    Thanks for information

  • @viswanathancr2801
    @viswanathancr2801 2 роки тому

    good video

  • @muzimazibs
    @muzimazibs 7 років тому

    What is the advantage of checking the resistance of the windings compared to checking for continuity?

    • @jasmany19
      @jasmany19 7 років тому +1

      Just checking for continuity across your windings will not tell you if you have a shorted winding. You have to check the actual resistance value of each winding and compare it to the others. The ohmic value should be very close across all windings.

    • @muzimazibs
      @muzimazibs 7 років тому

      I understand

    • @Pats-Shed
      @Pats-Shed 6 років тому +1

      Muziwandile Mazibuko . If you test the resistance of each winding using an accurate meter like this , you can check for damage within the coil such as a short circuit resulting in a lower resistance reading or an overheated coil due to a bad contactor will show up with this test . This kind of damage may not be apparent otherwise.

  • @robericom
    @robericom 3 роки тому

    Do you do the 1 & 10 minute PIR test for each winding?

    • @newname9262
      @newname9262 3 роки тому

      He connected all 3 windings together, so no. You'll just be testing all 3 at the same time.
      I like to disconnect them from each other and do the test on each on though. Proves they're ok on their own.

  • @racerx942
    @racerx942 3 роки тому

    How do you know wich is uvw and wuv?

  • @Britcoolful
    @Britcoolful 4 роки тому

    Instant motor burn and fuse trip after that random direction windings. Good for learners. 🤗

  • @Okie-Tom
    @Okie-Tom 8 років тому +1

    What is the brand and model of your tester?

  • @Sparklife-UK
    @Sparklife-UK 3 роки тому

    Thanks Chris

  • @dan57dan57
    @dan57dan57 7 років тому +5

    you did not identify the polarity of the windings, if one winding is incorrect, the motor will burn out over a period of time

    • @athenian10
      @athenian10 5 років тому

      A Long period of time !

    • @reissner1967
      @reissner1967 5 років тому +2

      I had a motor come back from being “rewound” and one set of windings was mislabelled. U1 & U2 were backward. This caused the motor to draw about 185% of full load current. The motor ran slow and erratic with no load. I found the winding that was backward and relabelled it and tried it again and it only drew less than 40% of FLA with no load on the motor. Finding the three windings is the first step, then you have to find which ends are U, V & W 1 and which are U V & W 2 because when they are wired up they form a phaser diagram for current. Each should be 120 degrees apart. If a winding is backward, one current will be between the other two on the short angle. Let’s say all windings are okay and the currents are 100 A at 0 degrees and the second is 100 A at -120 degrees and the third is 100 A at +120 degrees. If the third winding was wired backward because it was mislabelled, then the currents would be: 100 A at 0 degrees and the second is 100 A at -120 degrees and the third is 100 A at -60 degrees(+120 degrees - 180 degrees). If you plot them you will see why the current is so much higher at no load. If it was a perfect motor, the current would be 200%. If this still doesn’t make sense, plot the voltages and currents in each winding on a phaser diagram and reverse one winding and do the plot again to see the effect when you add the currents.

  • @dritonneziraj2010
    @dritonneziraj2010 8 років тому +4

    very helpful thank you !

  • @khadraj3178
    @khadraj3178 5 років тому +1

    hello sir,Thank you for your great videos, I’v a refrigeration compressor works and then stops for less than a minute and it’s circuit breaker cut off, when i measured the current for 3 phases, I noticed L2 giving a very high current "3 times the normal value" and L1 and L2 normal, what is expected to occur this problem, Even though there is a failure phase sequence in the circuit

    • @MountainBikers2015
      @MountainBikers2015 4 роки тому +2

      It’s either that in your system they are using your L2’s 230V to control a light or the control circuits or you are experiencing a motor that is unbalanced and you’d be expecting very low resistance on L2 due to the breaking down of windings

    • @matthewmeuleman3369
      @matthewmeuleman3369 4 роки тому +3

      Ohm's law, voltage = current * resistance. If your current has gone up, your resistance has gone down. The winding would have failed insulation about 1/3 along its winding, shortening the length of the active winding, thus lowering the resistance.
      If the winding draws 3 times normal current, then the motor draws 5/3 of its rated value. Circuit breakers used in motor protection take longer to trip, as to allow for the high start up current of motors.
      Phase protection is to save your motor from running on two phases if one phase goes down.

  • @ThorOdinson1269
    @ThorOdinson1269 3 роки тому

    Thank you for the video kind sir.

  • @gassanali8667
    @gassanali8667 4 роки тому

    crystal clear and super informative

  • @rmascarinas47
    @rmascarinas47 3 роки тому

    in any rate of motor doing same procedure Sir? 😊😊

  • @glauciooliveira5654
    @glauciooliveira5654 8 років тому +1

    Good informations !!!Thanks for share!!!!

  • @one4stevo
    @one4stevo 4 роки тому

    I got a 3 phase motor i like to hook it up to a single phase vfd i know i need to set the motor for delta, and they have been paired. but my problem is there is no u v w labels does this matter can you "call them anything like you say"

  • @sonnybernaljr
    @sonnybernaljr 2 роки тому

    What happen if i connect V1 U1 W1 for YWE connection.ty

  • @yadunathpandey7740
    @yadunathpandey7740 7 років тому

    Is 3 phase 5 wire is useful?

  • @has997
    @has997 5 років тому

    Hi Please how can i identify unmarked 6 leads on 3 phase motor ? In order to use delta connection

  • @balajividhya6234
    @balajividhya6234 6 років тому

    Very nice explanation thanks but after megger y u not short the leads to earth

  • @mechtechtechnician7040
    @mechtechtechnician7040 5 років тому

    I'm from India.I'm general mechanical technician.3phase motor like 3wire I mean uvw.or ryb.star connection to connect u1-w2,v2-w3,w3-w1.,we can check amp minimum value it's coming every star connection motors condition ok.in 3connection any one less.that motor has ground.replace another motor

  • @user-sq4zs7fx8z
    @user-sq4zs7fx8z 5 місяців тому

    Hi sir how do you test single phase motor

  • @0786RICARDO
    @0786RICARDO 8 років тому

    Does the polarization on the insulation applies same way for all types of insulation?

  • @vrexxter1750
    @vrexxter1750 5 років тому

    The insulation quality test required for each lead? I'm think yes .

  • @madhanbabu9920
    @madhanbabu9920 3 роки тому

    Nice

  • @gatekeeper88
    @gatekeeper88 7 років тому

    what meter is that please?

  • @andrewbarber6992
    @andrewbarber6992 8 років тому

    Clear and concise, thanks

  • @ekubayfisseha6567
    @ekubayfisseha6567 5 років тому +1

    thank you ,so useful video

  • @dundasjunctionmodelr.r-jam8267
    @dundasjunctionmodelr.r-jam8267 7 років тому +2

    How do you know if phases are reversed In Canada we number leads 1,2,3,4,5,6, Y connection 4,5,6 but if all leads same colour ?,

    • @Bmwm54ever
      @Bmwm54ever 7 років тому +1

      James Gaulton color code. I work for a company the everytime we replace a electric motor , either will rotate wrong direction or the brake won't release.

    • @s0m3th1n6s177y
      @s0m3th1n6s177y 6 років тому +1

      Damn Canadians! Why is math standard and electricity all different.

  • @james77011
    @james77011 5 років тому +1

    if the resistance is the same on all winding, how r u knowing whats what?

    • @DavomaTechTv
      @DavomaTechTv 5 років тому

      Because winding of same terminal gives low resistance value.

    • @RobsRobotChannel
      @RobsRobotChannel 5 років тому +1

      Yea but you don't know what is U, V, or W just from the ohms. I see the point of the question. Seems like the instructor rushed through a couple points.

  • @Bianchi77
    @Bianchi77 2 роки тому

    Creative video, thanks :)

  • @MsBlkz
    @MsBlkz 3 роки тому

    How to find head and tail of winding