@@mrsvensmile Hiya and thanks for the comments. Basic system breakdown in the description but in addition i have a Siemens Sirius high voltage DC monitoring relay controlling a 7.5kw resistor bank via a 3 phase solid state relay to limit the turbine in high winds! As the TriStar can only cope with 3.3KW which covers most typical wind speeds. I also have a soft stop system of relays to electronically brake/stop the turbine controlled automatically on full battery or remotely via my phone using a Shelly relay. Sounds complex but it's all pretty straightforward to setup!
Hey Billy I’m planning to build and install also a heli 4.0 which setup are you using?
@@mrsvensmile Hiya and thanks for the comments. Basic system breakdown in the description but in addition i have a Siemens Sirius high voltage DC monitoring relay controlling a 7.5kw resistor bank via a 3 phase solid state relay to limit the turbine in high winds! As the TriStar can only cope with 3.3KW which covers most typical wind speeds. I also have a soft stop system of relays to electronically brake/stop the turbine controlled automatically on full battery or remotely via my phone using a Shelly relay. Sounds complex but it's all pretty straightforward to setup!
@ what I nice setup! I really will take you setup in mind and copie some components thanks from the Netherlands!