Have You Ever Seen a Turbomolecular Pump Like This One?

Поділитися
Вставка
  • Опубліковано 25 кві 2024
  • I have a new turbomolecular pump. A split-flow pump, to be precise. However, it is indicating an error, and in today's video, I will try to get it running again and mount it on my vacuum chamber.
    Join my Patreon and support my projects! Your contribution means the world to me and helps bring my ideas to life. I truly appreciate your support! / advancedtinkering
    If you need custom circuit boards, 3D printed parts, or CNC-machined components, visit PCBWay: www.pcbway.com/
    Wissel-Vakuum: en.wissel-vakuum.de/
    Website to simulate an ideal gas: phet.colorado.edu/en/simulati...
    Stock Image: www.pexels.com/de-de/@masterc...
    Vacuum Discord Server:
    1: / discord
    2: / discord
  • Наука та технологія

КОМЕНТАРІ • 99

  • @AdvancedTinkering
    @AdvancedTinkering  27 днів тому +24

    Thank you to all the comments that informed me that the non-insulated transformer was the cause of the electric shock. That was a careless mistake on my part.
    Thank you for explaining the reason!

  • @contomo5710
    @contomo5710 28 днів тому +148

    you must be the sole reason for the price increase of used turbomolecular pumps in germany

    • @AdvancedTinkering
      @AdvancedTinkering  28 днів тому +17

      Sorry :(

    • @Xsiondu
      @Xsiondu 26 днів тому

      Do you, or someone you know, have a problem with acquiring turbo molecular pumps? Help is available. You and your loved ones don't have to suffer alone. Visit Lab Equipment Anonymous and begin your recovery today.

  • @0verv0ltage
    @0verv0ltage 28 днів тому +121

    The output from a autotransformer is not isolated from mains. So the 48VDC supply you build using the variac wasnt isolated from mains either.

    • @PlaywithJunk
      @PlaywithJunk 28 днів тому +14

      Yeah that's pretty dangerous. You get full mains voltage on the pump case if you're unlucky. He was lucky not to fry the USB adapter...

    • @jaymzx0
      @jaymzx0 27 днів тому +11

      Yup. For these types of shenanigans it's good to have a 1:1 isolation transformer handy. It's also useful if you want to use an oscilloscope on mains-connected circuits.

    • @1495978707
      @1495978707 3 дні тому

      ​@@jaymzx0I recently fried something because of this... but it was a junk for curiosity thing and isolation transformers aren't exactly free

  • @EeroafHeurlin
    @EeroafHeurlin 26 днів тому +23

    "Countless people still grow up withour access to a lathe or a milling machine" is such a great intro to the sponsor segment.

  • @sealpiercing8476
    @sealpiercing8476 28 днів тому +48

    The professionally improvised adapters bring me great nostalgia. Everyone does this, I think.

    • @AdvancedTinkering
      @AdvancedTinkering  28 днів тому +8

      Haha, I'm happy to hear that I'm not the only one.

    • @sealpiercing8476
      @sealpiercing8476 28 днів тому +11

      ​@@AdvancedTinkering I once made several adapters between 16 inch CF flange and 55 gallon trash can :P

  • @allesklarklaus147
    @allesklarklaus147 28 днів тому +16

    Variacs are autotransformers and thus not galvanically isolated on the secondary side. So the output is still referenced to mains earth and a single point of contact can give you a shock. Since you rectified the voltage, both positive and negative terminals are connected to the reduced mains voltage (alternatingly via the rectifier diodes) and thus have a certain potential against mains earth/your body. One of those two is probably connected to the pump housing (probably the negative one aka "ground").

  • @thevoidedwarranty
    @thevoidedwarranty 28 днів тому +23

    You were very lucky that you didn't destroy anything because variacs are not isolated .

  • @SignalDitch
    @SignalDitch 28 днів тому +13

    Ah, the familiar feeling of listening to a questionable turbo noise with your hand hovering over the STOP button

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому +2

      Like it will change anything if something goes really wrong haha

  • @TheBackyardChemist
    @TheBackyardChemist 28 днів тому +15

    Variacs are not isolated transformers IIRC. So it is possible that this pump is designed for an isolated PSU and connects the body to "ground", but you got the live and neutral swapped and the input voltage is present between the body and mains earth!

  • @alexandermarsteller7848
    @alexandermarsteller7848 28 днів тому +4

    Ahh, the good old Pfeiffer experience of having the wrong voltage version controller for a pump.
    If the pump has already been running for a long time and you are going to pump heavy gasses like argon, you might run into material fatigue of the rotor at some point. You might want to think about connecting the pump to some extrusions to absorb torque in case of a crash rather than have the ISO-KF flange suffer the hit.
    In any case, very nice to see how your project is coming along.

  • @dtiydr
    @dtiydr 28 днів тому +6

    A variac is not isolated from mains so the case got full mains on it (there exist variacs that are isolated but they are very rare and extremely expensive) so if not fully understand them they can be lethal, you were very lucky there.

  • @thomaskerslack4299
    @thomaskerslack4299 28 днів тому +8

    The reason for audible vibrations can also come from the fact, that the rotor speed of the pump sometimes hits exactly the resonance frequency of your chamber (or a multiple of it). Espeacially all the aluminium foil likes to vibrate and make sound ;)
    I have a spectrometer at work with 9 turbopumps attached, and when I turn all of them on or off at the same time, it not only sounds like the deck of an aircraft carrier, but also some really nasty high pitch sounds from resonating components in between :D

    • @Xsiondu
      @Xsiondu 27 днів тому

      Phew that actually makes me less worried. Thank you.

  • @martin09091989
    @martin09091989 28 днів тому +18

    Tip for using threads locker or pipe dope: put it on the male part of the thread!
    If you put it on the female part the bolt tip will push out the majority, if applied on the male part it will get spread between the threads all the way in. And on pipes you don't push the surplus into the media side! 😉
    Bolts still won't fall out though.

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому

      Thanks for the advice!

    • @artemiypolozhintsev6190
      @artemiypolozhintsev6190 3 дні тому

      ​@@AdvancedTinkeringbe careful though, this is only valid for through holes! On blind holes the correct way is to put it into the hole as you did it, then the thread locker gets squeezed up along the whole thread as you compress the space below the bolt.

  • @derredc
    @derredc 28 днів тому +8

    I never even finished high school, but somehow you manage to make sense to me over and over again. Thanks for not being afraid to simplify things, and thanks for not being afraid to be complicated where it's needed. Always very interesting, always very entertaining.

  • @willtipton
    @willtipton 9 днів тому +1

    I appreciate the tip about PV Turbo viewer software. I was able to find and download it and also make an adapter for the Pfeiffer turbos we have at work. Thanks!! My team now has much better visibility of the turbo parameters during troubleshooting.

  • @knibknibknib
    @knibknibknib 27 днів тому +3

    Searching for swollen capacitors was the bane of my job here for the first year. I found and replaced three with no luck. One starting capacitor on a coolant pump, a power supply capacitor for an Edwards turbo controller, and one on a small pneumatic control block. Lesson learned, I'm an not an electrician. Lessons also learned at my current job; I'm not an optician, wet chemist, or physics modeling expert. What I am is a middling button monkey. 😅

  • @Kirill_Maker
    @Kirill_Maker 28 днів тому +6

    I guess that autotransformer doesn't give you galvanic isolation that's why you got live on case :)

  • @KillianTwew
    @KillianTwew 20 днів тому

    2:25 I thought you started it for a second LOL
    Very intuitive explanation of mean-free-path. When I started working at our cryolab, they had a 6FT 25KF bellowed tube between the vessels and the TMP's. It was taking them three hours to pump down to the required pressure for tests. Now it's like 30 minutes

  • @BeigeAlert
    @BeigeAlert 28 днів тому +2

    We've got some in the mass spectrometry lab with that kind of hours, I can't believe something can do 90,000 RPM for over ten solid years but I guess it makes the high price feel more reasonable!

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому

      This one spins at 60k RPM, but it’s still incredibly impressive.

  • @Alexelectricalengineering
    @Alexelectricalengineering 28 днів тому +2

    Awesome video, thumbs up 😎
    There was no galvanic isolation on your variac and bridge rectifier, and most likely the negative is connected to the chassis of the controller that's connected to the pump, that's why you was get electric shock!

  • @alialy210
    @alialy210 27 днів тому +1

    I really hope you do a more in depth video about the different pump and different mechanism. This is very interesting.

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому

      I made a video about diffusion pumps (and a short one about my cryopump) but I haven’t covered the others yet.

  • @ChrisEldridge
    @ChrisEldridge 28 днів тому +2

    I just learned about these a few months ago when tearing down a leak checker. Pretty neat stuff. Looking forward to when you get a cryo as well.

  • @eriknielsen1849
    @eriknielsen1849 11 годин тому

    A big 👍👍👍 for a informative video where I learned a lot I can use later for water desalination here in West Sahara.

  • @BalticLab
    @BalticLab 25 днів тому

    Strange, I wasn't notified to this new upload by YT until today... Great video!

  • @DoAyBarrelRoll
    @DoAyBarrelRoll 28 днів тому +2

    The voltage thing was very confusing at first. Spent a good amount of time making sure that the voltage was correct for my pump. Nice to see that the controller can account for the voltage and not damage the pump due to incorrect voltage.

  • @DEtchells
    @DEtchells 27 днів тому

    It may not matter at the pressures you’ll be using for sputtering, but mating threads create PITA virtual leaks for high vacuum. A narrow groove milled or ground lengthwise along the shaft of the bolt wherever there’ll be a nut or it will enter or pass through a threaded hole will shorten the escape path for air molecules and drastically shorten the pumping time to reach higher vacuums.

  • @aleksadjokic4115
    @aleksadjokic4115 12 днів тому

    Hi! Good work as usual! You should replace the oil cartridge in the pump with a fresh one ASAP. Since I have many old used pumps with more then 32000h of run time, I usual just soak the cartridges with fresh TL011 oil, works good but its better to replace with new.

  • @daisywong-ke1kz
    @daisywong-ke1kz 22 дні тому +1

    Woww really stunning work!🤩

  • @ToxicMrSmith
    @ToxicMrSmith 28 днів тому +1

    Ill be honest, i just like spinning turbines and thats why i like this channel.

  • @HerosAndZeros
    @HerosAndZeros 26 днів тому

    Please, for your safety, never use variacs like this! One side is drectly connected to mains. You have a 50% chance that your pump ”ground” is at mains voltage. But you already managed to find out. Thanks for your video!

  • @FUZxxl
    @FUZxxl 25 днів тому

    Your ad convinced me, I should get a lathe!

  • @morrisputman8592
    @morrisputman8592 28 днів тому +2

    i learned so much from this video! thanks ;)

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому +1

      I’m happy to hear that you liked it and learned something new! :)

  • @flomojo2u
    @flomojo2u 28 днів тому

    For a student you always seem to have very nice equipment! I hope your pump works out for you, I also have a split molecular pump and just blocked up the lower vacuum hole with an aluminum plate. It worked just fine, and although I switched to another pump, I never had problems with it. I definitely got some odd noises when it spun up, but I believe this has to do with the transition from being supported by sleeve bearings to the magnetic bearings once it spins fast enough.

  • @nilamotk
    @nilamotk 28 днів тому +1

    I have zero use for an ultra high vacuum setup, but I feel I need one for some reason... 🤔😂

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому

      Better to have it and not need it than to need it and not have it ;)

  • @WernerEngel1
    @WernerEngel1 27 днів тому +1

    Have fun with the QCM and its temperature drift ;-)
    And did you think about using scroll pump - they are oil free and provide a much cleaner vacuum. There are the NxDS15i but also Pfeiffer provides them - and they are very silent!!

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому

      Thanks ;)
      I would love to have a scroll pump at some point, but I haven’t found one I can afford yet. But I will keep an eye out.

  • @XAirForce
    @XAirForce 28 днів тому +1

    Thanks!

  • @hisuiibmpower4
    @hisuiibmpower4 27 днів тому +1

    I think this controller is just a VFD if u get the voltage,amp and frequency right other contorller/vfd will also work on this pump

  • @tannerbean3801
    @tannerbean3801 27 днів тому

    Sweet! I have a little pfeiffer TMP I bought for like $150 USD. I'll see if I can get it running

  • @lady_draguliana784
    @lady_draguliana784 27 днів тому +1

    For SOME reason, for a miniscule moment, a minute part of my Being felt insanely compelled to find: or make: an electrical engineering or electronics manual written in Shakespearian meter... 🤔
    🤣

  • @user-ek4pg9wn2d
    @user-ek4pg9wn2d 28 днів тому +1

    nice!

  • @hanyolo105
    @hanyolo105 27 днів тому

    Dude, nice concept and I love the presentation! I am currently working on an abstract proposing a piston operated modulated pump to create very low pressures. Working title 'The POMP' :) I would very much like to exchange ideas with you and anyone here interested.

  • @AngDavies
    @AngDavies 28 днів тому +1

    German plugs are unpolarized if i recall correctly, so it would be a tossup whether the output of the variac was referenced to neutral( which should be around earth or live

    • @AngDavies
      @AngDavies 27 днів тому

      So to clarify 48v DC corresponds to about 34v AC. Because of unpolarized German plugs the two outputs of the Variac will be either 0 and 34v with respect to ground. Or 230v and 230-34=196v with respect to ground, depending on which way you plug it in. You rolled unlucky and got the second, and thus basically just touched the live, and got a shock

  • @ahfreebird
    @ahfreebird 24 дні тому +1

    317 billion rotations on those bearings!

    • @AdvancedTinkering
      @AdvancedTinkering  24 дні тому

      Haha, awesome, I didn't think about that. That's mind blowing!

  • @Minecraftmigapiku
    @Minecraftmigapiku 27 днів тому +1

    For my bachelors I did QCM meter. If you'd have any problems with yours, would like to build custom one or need help in any way feel free to reach out.

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому

      Thank you for the offer!
      I haven't been able to test the QCM yet, as components of the quartz holder are likely missing. I would appreciate it if you could send me an email when you have time, and we can discuss some of my questions. The email address is in my UA-cam profile.

  • @Akideoni
    @Akideoni 22 дні тому

    That thing is sure heavy

  • @ChiralSymmetry
    @ChiralSymmetry 26 днів тому

    What type of mechanical bearings are used inside the turbomolecular pump? After 80,000 hrs of use, I would worry they might have worn out?

  • @zaprodk
    @zaprodk 28 днів тому +4

    You got an electric shock because that Variac is NOT insulated from the mains. Both the controller and your computer is at mains potential. This is VERY dangerous. Please do not do this!

  • @nekomakhea9440
    @nekomakhea9440 28 днів тому

    I'm pretty sure he spends more time playing with his turbopump collection than actually making vacuums

  • @Ma_X64
    @Ma_X64 26 днів тому

    Variac you used isn't isolated from the grid and your equipment has GND net connected to its body. So you have phase potential on all your equipment. Never use a variac to power any low voltage equipment without an additional isolating transformer. It is quite dangerous not only phisiologically-vise but also from fire-safety view. And, of course, getting shock from your equipment means draining some current through your body but this current may damage random electronics in your equipment because it goes trhough almost random nets like digital interfaces, sensor cables and so on.
    *I heard that using turbomolecular pump with no pre-vacuuming with usual pump isn't a good idea. I don't know if it's really true or not but I can see some logics in it.

  • @wendelinweingartner7904
    @wendelinweingartner7904 28 днів тому +1

    Great video. Can you please point to the turboviewer download page?

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому

      Can you send me an email? I don't know if Pfeiffer wants me to share the link on the comments.

  • @pokojnitozo2360
    @pokojnitozo2360 28 днів тому +2

    You got shock because you are still referenced to mains. You do not have galvanic isolation.
    You are lucki you didn't connected something else to laptop. You also could get shock fromlaptop.
    Please use isolation transformer....

  • @tomholroyd7519
    @tomholroyd7519 28 днів тому +1

    I like cryopumps

  • @VinokDesign
    @VinokDesign 27 днів тому

    What is the discord channel you are on for the vacuum stuff? I have 3 turbomoleculars pumps, want to sell 2 of them

  • @Kyle_0701
    @Kyle_0701 28 днів тому +2

    9:50 Going to build a milling machine soon?

  • @Drinksfromtap
    @Drinksfromtap 27 днів тому

    No, no I have not seen a turbomolecular pump like this. Probably cause the only place I ever see such pumps is on your channel 🤪

  • @Mark-ce9xh
    @Mark-ce9xh 4 дні тому

    You're not using the massive pump on your chamber anymore?

  • @elitearbor
    @elitearbor 28 днів тому

    "Manual? No, it's automatic, why do you ask?"

  • @UltrAgejmr
    @UltrAgejmr 27 днів тому

    You should use Raspberry Pi rather than whole PC for monitoring and even maybe controlling the vacuum table components.

    • @ThiefMaster
      @ThiefMaster 27 днів тому

      There's a good chance whatever software he uses (self-made stuff aside) runs on standard x86 Windows systems. The Raspberry PI has an ARM CPU. So not a great combination.
      A small-form-factor x86 PC makes much more sense here, e.g. an Intel NUC or similar.

  • @jimsvideos7201
    @jimsvideos7201 28 днів тому

    60k RPM? 😮

  • @Xsiondu
    @Xsiondu 27 днів тому +1

    I thought it wasn't safe to turn on these types of pumps in open atmosphere. Was i misinformed?

    • @AdvancedTinkering
      @AdvancedTinkering  27 днів тому +1

      There is no harm in starting a turbomolecular pump at atmospheric pressure for a few seconds.
      You shouldn't vent it when it's at full speed or let it run for long times. But it won't hurt the pump to shortly spin up.

    • @Xsiondu
      @Xsiondu 26 днів тому

      @@AdvancedTinkering cool! Thank you for explaining that to me.

  • @cyberbiosecurity
    @cyberbiosecurity 25 днів тому

    what about antimatter chamber gas annihilation pump?
    oh sorry this is a spoiler

  • @beachboardfan9544
    @beachboardfan9544 27 днів тому

    Electrolytic caps are such a chronic failure point. Why are they still used, surely theres a more reliable alternative!

  • @kamilguzik3870
    @kamilguzik3870 25 днів тому

    comment

  • @aswinpradeep5681
    @aswinpradeep5681 7 днів тому

    Meanwhile me first of all what is molecular pump

  • @erniecamhan
    @erniecamhan 28 днів тому

    Never run a turbo pump at atmospheric pressure, it needs to be in high vacuum

    • @AdvancedTinkering
      @AdvancedTinkering  28 днів тому +13

      There is no harm in starting a turbomolecular pump at atmospheric pressure for a few seconds.
      You shouldn't vent it when it's at full speed or let it run for long times. But it won't hurt the pump to shortly spin up.

    • @christopherleubner6633
      @christopherleubner6633 28 днів тому +5

      Yup its OK to test for a few seconds to see if the motor spins.. The worst thing that could happen is if your chamber has a sudden catastrophic leak while spinning at full speed. This is BAD. I've seen them grenade from that before.😮

    • @ChrisEldridge
      @ChrisEldridge 28 днів тому +2

      @@christopherleubner6633 I usually go with Turbo Salad. I have also heard it called Turbo Confetti. There was no food or fun when either of those happened.

    •  28 днів тому

      @@christopherleubner6633 That will wake you up!

  • @infectedrainbow
    @infectedrainbow 27 днів тому +2

    I have to say, a German riffing on Shakespeare makes me feel grossly ignorant...well played.