How to Wire a 4 String PV Combiner Box - Combines Box Wiring for Your Solar Panels

Поділитися
Вставка
  • Опубліковано 8 жов 2022
  • This video is about solar dc combiner box.
    in this video tutorial, I will show you solar panels string connection with Combiner Box.
    Disclaimer
    Video is for educational purpose only Copyright Disclaimer Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research Fair use is a use permitted by copyright statute that might otherwise be infringing Non-profit, educational or personal use tips the balance in favor of fair use
    Some photos in the video are downloaded from Google Image. The picture used in this video is protected by the Fair Use Law, section 107 used for commentary, criticism, news reporting, or education for transformative use.
    Thank You
    Other social links
    Instagram:
    / ak.electricdiy
    Facebook:
    profile.php?...
    tiktok:
    tiktok.com/@akelectricdiy

КОМЕНТАРІ • 58

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 7 місяців тому +5

    Thank You Ak-E-DIY, ...
    Very easy to UNDERSTAND
    COOP
    the WiSeNhEiMeR from Richmond, INDIANA
    ...

  • @milespraza3374
    @milespraza3374 Рік тому +2

    amazing demonstration!

  • @LammiiDirribaa
    @LammiiDirribaa 9 днів тому +1

  • @fadzimeki1117
    @fadzimeki1117 7 місяців тому

    Simple easy and understandable illustrations

  • @internationalbusiness5877
    @internationalbusiness5877 4 дні тому

    What I learned today is that, 1 fuse is 15A and 6 panels parallel-connected to 1 strings is equivalent to 8A x 6 = 48A.
    Which will overload the fuse and blow if we connect it like your diagram shows.

  • @MrPmanshimba
    @MrPmanshimba 4 місяці тому

    Yeah nice and neat.

  • @Boersenwunder-
    @Boersenwunder- 4 місяці тому

    Hi! Have you ever heard of the Shoals Plug and Play cables / system? Can anyone judge whether it makes sense to use it? Although they seem to be a bit more expensive, they are extremely easy to use and no professional installer is required. Installation is also said to be very quick and more energy efficient than conventional cables... Some thoughts on it?

  • @valramsingh8360
    @valramsingh8360 Рік тому +2

    do a video with a large system using recombiner boxes..

  • @jfbaro2
    @jfbaro2 11 місяців тому +1

    Is there a type of "combiner box" available that can primarily utilize power from solar panels (when sunlight is available) and supplement its output with grid power (as a secondary source) only when the solar current is insufficient to meet the required output?

    • @rarefruit2320
      @rarefruit2320 6 місяців тому

      That’s the job of the charge controller

    • @Reels24720
      @Reels24720 3 місяці тому

      Make use of string inverter

  • @ericyapi7182
    @ericyapi7182 Рік тому +2

    Why only the + cables go to Into the fuses when we have to use the + polarity and - polarity fuses in the junction box?

    • @MrPmanshimba
      @MrPmanshimba 4 місяці тому

      I believe that the Fuse he is using are not 2 pole fuses so that's why.

  • @raimonbawazir5449
    @raimonbawazir5449 5 днів тому

    thank you for this rich video. can I know the name of this software to draw?

  • @p5makersplace
    @p5makersplace Рік тому

    Using this example, what is the voltage of each panel before series wiring? Also - what gauge wire would then be used on the output feed to the inverter?

    • @akelectricdiy
      @akelectricdiy  Рік тому

      Complete details in the next upcoming video. Thanks for your comments 🙂

  • @ratishcreative5495
    @ratishcreative5495 7 місяців тому

    What is the range of floting voltage in 20 pv string

  • @rekedek
    @rekedek Рік тому

    Can you explain to me why you connect all the (-) and (+) ,except the first (+), together and then conect them with a black (-) cable to the combiner box and in the meantime draw a red (+) cable of the first (+). Instead of connecting separately all the (-) of the panels together and connect them with a black (-) cable to the combiner box and all the (+) together and connect them tο the combiner box with a red (+) solar cable?

    • @akelectricdiy
      @akelectricdiy  Рік тому +3

      • All pv strings connected in series The series circuit definition states that a series circuit is a path where the current flows from one component to another through a single path.
      • In these types of series circuits, the negative terminal of the component is connected with the positive terminal and vice versa.

    • @rekedek
      @rekedek Рік тому +1

      @@akelectricdiy Thanks for your response

  • @PastorJamesAndrews
    @PastorJamesAndrews 10 місяців тому +2

    Instead of going to “inverter in” could you also go to the “charge controller”, then from the “charge controller” to “inverter in”?

  • @crnibozur4312
    @crnibozur4312 6 місяців тому +3

    Many mistakes in the video. Minus wire also shoud go through fuse, SPD comes after MCB....

  • @leehawkins1533
    @leehawkins1533 Рік тому +2

    You said it was parallel but you connected as a series string

  • @khaleddhr6238
    @khaleddhr6238 Рік тому

    If i want to use this diagram some times and change all (pv1,pv2,pv3,pv4) to series to use it and return again to first diagram ,How to do that without adding new solar panels?

    • @sale666
      @sale666 8 місяців тому

      This is a series connection looking at the panels... the only thing that makes it parallel is the bus bur.. you should than connect each string to its own fuse and than from the fuse to its own breaker per string... assuming your inverter handles 4 separate strings in

  • @rintomarambadjawa5904
    @rintomarambadjawa5904 4 місяці тому

    Untuk outputnya dapat brp

  • @rongray4118
    @rongray4118 4 місяці тому

    No mention of size of array/amps/volt/watts...

  • @AmanKhan-hf6pj
    @AmanKhan-hf6pj 3 місяці тому

    Kya Nitrox 6 kw k liye agar do string lagayen to Kya Dono barabar panels k hony chahiye ?
    Matlab agar aik string 9 panels.
    Aur dosra 3 panels. ho to Kya Hoga?

    • @akelectricdiy
      @akelectricdiy  3 місяці тому

      Please share with me inverter and solar panels nameplate picture

    • @AmanKhan-hf6pj
      @AmanKhan-hf6pj 3 місяці тому

      @@akelectricdiy Nitrox 6 kw new model hai. Aur JA Solar 545w k 9 panels aik string lagi hoi hai.

  • @larrymiller7128
    @larrymiller7128 Рік тому

    If my inverter only has max open voltage of 150, how to I run 16 of 320 w 39 open voltage panels

    • @akelectricdiy
      @akelectricdiy  Рік тому

      Please send me an inverter name plate picture

    • @brianimpellizzeri325
      @brianimpellizzeri325 7 місяців тому +1

      3 series max VOC of 117. Parallel depends on ISC and max amps of weakest link in the string. Wire is 30A.

  • @jmonteen
    @jmonteen 10 місяців тому

    What is a Nutrial busbar?

  • @rintomarambadjawa5904
    @rintomarambadjawa5904 4 місяці тому

    Bang,untuk panel surya thin film arus bolang balik,pake pv brpa lembar agar dapat arus ac 220🙏?

    • @akelectricdiy
      @akelectricdiy  4 місяці тому

      In the series string, solar panels voltage is added, and the current remains the same.
      In parallel string connection, solar panels voltage remaining the same, and current adding this depends on your system

  • @sunjayjay240
    @sunjayjay240 Рік тому

    can u show different Voltages per string
    what wil be addition

    • @Solar-Sigma
      @Solar-Sigma Рік тому

      In this scene in the video, the current and voltage of each string should be consistent.

  • @mosfet500
    @mosfet500 Рік тому +2

    Won't work, series voltage is too high for charge controllers in off grid apps. Running long strings is best with microinverters or SolarEdge optimizers in intertie apps.

    • @charliewatts6895
      @charliewatts6895 Рік тому +1

      Agree. Assuming each panel is 25 volts VDC (conservatively), that's 150 volts per string x 4, or 600 volts. That's packing a wallop, and well above any controller (Just the first string along would exceed capability for my off-grid controller). For safety reasons, it's not recommended that 100 volts VDC be exceeded. VDC at the level can kill.

    • @user-xb2of4sr9q
      @user-xb2of4sr9q Рік тому +1

      I have solar panels that are rated 540w
      My vmpp is 40.5 v I’m aiming to connect them to an inverter that runs a motor for water pumping
      I will use 64 panels so they can provide 34kw. So I’m using 4 strings each with 16 panels in series
      If i add up the volts in one string i will end up with 650dcv is that dangerous?
      Also what do you suggest?

    • @user-xb2of4sr9q
      @user-xb2of4sr9q Рік тому

      And also mine is on grid
      Thanks

    • @mosfet500
      @mosfet500 Рік тому

      @@user-xb2of4sr9q According to what you are saying each of your modules puts out 64/34k = 531.3 watts. I think there might be something wrong in your calculations. Microinverters, that is an inverter on each module, run high voltages as the string voltage is the sum of each module. If you're are feeding an inverter or charger controller that runs low voltages you have to make your bank something like 2 modules in series connect in parallel, that is 2 S x 16p, that will give your a total voltage of~81V .according to your VMPP of 40.5 V.

    • @stefanstosic8379
      @stefanstosic8379 Рік тому +2

      @@charliewatts6895 Voltage does not add up across parallel connections, it's the current that increases, isn't it so?

  • @hlkdmegmailcom
    @hlkdmegmailcom 11 місяців тому

    I guess, 2 x series panels will only need one Fuse and the rest remain the same?
    How to calculate the size of FUSE, SPD, DC Breaker?