Home Automation 32CH Distribution Board DIY Smart Home IOT Project 2020

Поділитися
Вставка
  • Опубліковано 5 вер 2024

КОМЕНТАРІ • 454

  • @darioampuy
    @darioampuy Рік тому +27

    i would suggest for the next project, use a busbar instead of daisychaining the breakers... it's cleaner and safer. the only negative point in busbar is that you have to replace the busbar is you want to expand the circuit... havn't seen expandable busbars so far

    • @KinCony
      @KinCony  Рік тому +1

      yes, thanks for your suggestion, next project will improve it.

    • @pedroveloso9707
      @pedroveloso9707 Рік тому +1

      yeapp... busbar, and normal wire to the connection off the drivers, small secction. great job never the less :)

    • @pedroveloso9707
      @pedroveloso9707 Рік тому

      one more thing, 25A, and 2.5 wiring you are on the edge off it. better 16A to that wire section

    • @KinCony
      @KinCony  Рік тому

      @@pedroveloso9707 thank you

    • @KinCony
      @KinCony  Рік тому

      @@pedroveloso9707 ok, thanks.

  • @Willeexd1337
    @Willeexd1337 Рік тому +9

    Good idea for a project but you shouldn't really connect stuff like this. Daisy chaining the contactors like that will overheat if you draw a big current, use a busbar instead and split the circuit into different sections. So you use maybe 4 busbars with 4 wires from the main fuse to split up the load in the wires. The fuse should be before the contactor to protect it as well because those can't handle 63A like the main breaker is rated for. This is no hate its just some constructive criticism from someone who is a Automation engineer.
    edit: spelling error, English isn't my main language

    • @KinCony
      @KinCony  Рік тому +2

      thank you very much for your suggestion, we will make new video tour based on new controller and solution, it will be improved.

    • @Willeexd1337
      @Willeexd1337 Рік тому

      @@KinCony Nice! Looking forward to it :)

    • @KinCony
      @KinCony  Рік тому

      @@Willeexd1337 thanks.

  • @PHUC_DOHUU
    @PHUC_DOHUU Рік тому +8

    As a control and distribution cabinet, you should distinguish and specify the wire color, usually red wire for phase, black wire for neutral, green/yellow wire for ground, signal control wire is a small wire and also distinguished by wire color and the ends of the wire are the heat-generating contacts, so the presser should be used.

    • @KinCony
      @KinCony  Рік тому

      thanks for your suggestion, we are designing another new solution.

    • @dpsmoin2151
      @dpsmoin2151 Рік тому

      good think!

    • @dpsmoin2151
      @dpsmoin2151 Рік тому

      Distribution cabinet use the cable only fire alarm cable.

    • @KinCony
      @KinCony  Рік тому

      @@dpsmoin2151 how about this style? ua-cam.com/video/Ae4CDMBKRwA/v-deo.html

    • @waoooSky
      @waoooSky Рік тому

      @@KinCony waiting new design so

  • @ronross4288
    @ronross4288 Рік тому

    Ron Ross, I am a Principal Design Engineer for a Large Utility in the US. I just turned 67 and I will be retiring. I would like to add comments for improving your panel. I realize that this may be copied by others. I am not sure of the color code used but the hot wire here is black. White is used for the neutral and green for the ground wire. As I understood your control layout, the relays powered the circuit breakers which then fed the output to the circuits. The main breaker in the panel limits the internal and downstream circuits by its rating. I did not count the breakers, but I believe you had 32 at 25 Amp each. The main is maybe 63 amp? two pole. We do not break the neutral of white wire with a breaker in the US. If you are going to use a main breaker, it should be larger, maybe 100 amp. Also, you need to group the power runs in groups of 5 from the main. You are feeding them all with the same wire. The din rail under the relays and the breakers should have a screw thought the mounting plate about every six inches.

    • @KinCony
      @KinCony  Рік тому

      Thank you very much for your valuable advice, this video made by two years ago, this month we have made a new solution video tour, i think you will love it. ua-cam.com/video/Ae4CDMBKRwA/v-deo.html how about this solution?

  • @anoyarhosenmondal5205
    @anoyarhosenmondal5205 2 роки тому

    Sair very very nice video and easy proses to learning

  • @mohammadsaifkamal1468
    @mohammadsaifkamal1468 Рік тому +1

    Good sir 🇮🇳🇮🇳🇮🇳

  • @user-nt4ie4iv6l
    @user-nt4ie4iv6l Рік тому

    Very good

  • @paulbell7654
    @paulbell7654 Рік тому

    Death trap in a box! No separation of mains and low voltage. No earthing or bonding. Main switch feeding contractors without circuit protection. Undersized cables. RF devices installed inside a metal box - thanks for demonstration of what not to do.

    • @KinCony
      @KinCony  Рік тому

      next version will all improve

  • @ekesmanaffiliate9308
    @ekesmanaffiliate9308 2 роки тому

    I really appreciate your efforts in educating the world with innovations.
    Home automation has always been my dream career.
    Will you be my direct mentor?

    • @KinCony
      @KinCony  2 роки тому

      thanks, any question need help just leave message. we will help everyone.

    • @BTW...
      @BTW... Рік тому

      SRSLY?

  • @ASHOK-ob3yu
    @ASHOK-ob3yu Рік тому

    Hi nice

  • @EliasAwandaOduor
    @EliasAwandaOduor Рік тому

    This nice

  • @oaba201
    @oaba201 Рік тому

    Busbar (Splited (Not one large!!!!)) Clean the paint under the earth strap!!! I would put an earth strap between the back panel and box too. Labels. Larger neutral distribution bar. And earth distribution bar too. Wiring diagram on the inside of the door. I would put a switch on the front door. That does not allow the door to be opened while the switch is ON.
    The wire color might OK in your Country. EU IEC 60445:2021
    Might you want cabinet lighting as well?

    • @KinCony
      @KinCony  Рік тому

      thanks for your suggestion. this is our new solution: ua-cam.com/video/Ae4CDMBKRwA/v-deo.html this is better.

  • @abbarrukhanelectricandplum1750

    butyfull video

  • @DeKempster
    @DeKempster Рік тому

    Strange way of mounting the din rail. Why multiple pieces in the same row. Self tapers are also much easier. Good videos non the less, always interesting how people make cabinets in other countries.

    • @KinCony
      @KinCony  Рік тому

      thanks for suggestion.

  • @henkhakkertoene
    @henkhakkertoene Рік тому +3

    shouldn't the wire be thicker when the fuse is only 63 amps ?

    • @KinCony
      @KinCony  Рік тому

      yes, this demo, not use full of load current.

  • @shahzoddehqonov4935
    @shahzoddehqonov4935 Рік тому +1

    Thank a lot of

  • @gustavocalderon8153
    @gustavocalderon8153 3 роки тому +2

    Thanks a lot KinCony. Amazing job. I Will be waiting the second video of this Electrical WiFi Control Panel.

    • @KinCony
      @KinCony  3 роки тому +5

      if want to use wifi, just replace the controller with KC868-H32B is ok

  • @aglmbranagahmaddghabibah3573
    @aglmbranagahmaddghabibah3573 6 місяців тому

    Selamat pagi bos db gn dlm nya cantik gn kemas cuma ada lg kurang dlm db book tu tidak ada kipas pendingin haba panas untuk pcb bot control nya kalau tidak ada kipas pendingin udara apabila pcb bot tu nanti panas cepat rosak sebap panas alat elektronik pcb nya pasti tidak akan tahan lama gn cepat rosak jadi mesti kena letak kipas bos 😊🇲🇾

    • @KinCony
      @KinCony  6 місяців тому

      thanks for suggestion.

  • @Jumman_Hossen
    @Jumman_Hossen Рік тому

    Good

  • @shashikantmarskole
    @shashikantmarskole Рік тому +1

    nice work, love it. thank u

  • @Broadcast1Channel
    @Broadcast1Channel Рік тому +12

    Anyone viewing this please do not use this as a guide. Get in contact with a qualified electrician and find out how it should be done.

    • @frikkied2638
      @frikkied2638 Рік тому

      Wtf why? This is a super clean build.

    • @chunchun722
      @chunchun722 Рік тому

      ​@@frikkied2638cuz sometimes viewer copying the video and doing it wrong

    • @cedricschoemans5214
      @cedricschoemans5214 9 місяців тому

      Yes, but if you don't know what you're doing you can make some mistakes and that can put you and your house in danger when you try to connect with the power

  • @firsteerr
    @firsteerr 8 місяців тому +1

    can that 4mm singles take the sixty to 100 amps you will be drawing through it ?

    • @KinCony
      @KinCony  8 місяців тому

      ua-cam.com/video/Ae4CDMBKRwA/v-deo.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.😀

  • @KinCony
    @KinCony  Рік тому

    ua-cam.com/video/Ae4CDMBKRwA/v-deo.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.😀

  • @amadoubaa4700
    @amadoubaa4700 Рік тому +1

    ❤❤❤

  • @Alexander-dv9vx
    @Alexander-dv9vx Рік тому

    Мне кажется мягким проводом монтаж был бы намного проще, быстрее и надежнее. Идея хорошая, исполнение на 3.

    • @KinCony
      @KinCony  Рік тому

      thanks for suggestion, this is the newest solution: ua-cam.com/video/Ae4CDMBKRwA/v-deo.html

  • @wiratno6612
    @wiratno6612 3 роки тому +1

    this video is in accordance with my hobby.can the manual switch button be replaced with a touch switch?thank you.

    • @KinCony
      @KinCony  3 роки тому

      already can extend connect with wall switch. the black button inside of AC contactor only for emergency use.

    • @BTW...
      @BTW... Рік тому

      @@KinCony No, it's for isolation and bypassing control signals when testing.

    • @KinCony
      @KinCony  Рік тому

      @@BTW... if use bypassing control, will use COM,NC,NO will be very large space.

  • @barycza
    @barycza Рік тому +1

    No commentary - annyoing music in background instead. It tells everything about your channel quality.

    • @KinCony
      @KinCony  Рік тому

      next video will have voice explain.

  • @lameckobiero3160
    @lameckobiero3160 Рік тому

    i like the work,can this be used in offices

  • @oumartellydiallo6411
    @oumartellydiallo6411 Рік тому

    I would like to follow this training

  • @eliomargoncalves
    @eliomargoncalves 2 роки тому +1

    Parabéns. 1000 ok

  • @rickymeadows5176
    @rickymeadows5176 Рік тому

    Beautiful work !

  • @sandeepshinde4709
    @sandeepshinde4709 Рік тому

    Nice

  • @SrPachaman
    @SrPachaman Рік тому +1

    This is beautiful ❤

  • @metamud8686
    @metamud8686 Рік тому

    5:05 if you put those remote units in an all metal enclosure, won't that make for poor reception due to them being inside a Faraday cage?

    • @KinCony
      @KinCony  Рік тому

      mainly use by ethernet, not use by wifi.

  • @prashantdawar
    @prashantdawar Рік тому

    Awesome work

  • @muhammadsohaibkhan6224
    @muhammadsohaibkhan6224 2 роки тому

    I
    love this video

  • @MatSmithLondon
    @MatSmithLondon 3 роки тому +4

    I really like this work. Have you manufactured smart dimmers, like triac dimming or for LED light?

    • @KinCony
      @KinCony  3 роки тому +1

      i am dimmer, you can see this video: ua-cam.com/video/cKgbX8nO0jQ/v-deo.html

    • @MatSmithLondon
      @MatSmithLondon 3 роки тому +1

      @@KinCony Thank you! Do you have a triac dimmer as well (for incandescent or other lights)?

    • @KinCony
      @KinCony  3 роки тому +1

      yes, we have, KC868-D8 + SSR is ok, i will make video later.

  • @user-ri8mr1on9z
    @user-ri8mr1on9z 2 роки тому

    Great job

  • @weikeungtang6722
    @weikeungtang6722 Рік тому +1

    Bad to use more than 40 red short wires instead of using copper bar with plastic cover

    • @KinCony
      @KinCony  Рік тому

      thanks for suggestion.

  • @mrhendry6552
    @mrhendry6552 2 роки тому

    nice job sir

    • @BTW...
      @BTW... Рік тому

      No... dangerous and non complaint to any mains wiring Standard.

  • @mathiauskalanda9377
    @mathiauskalanda9377 Рік тому

    Hello Conny...requesting for circuit diagrams and software documents

    • @KinCony
      @KinCony  Рік тому

      Link in video description

  • @deang5622
    @deang5622 Рік тому

    Those MCBs are not intended for routine switching things on and off. Typical contact life is 100,000 operations.

    • @KinCony
      @KinCony  Рік тому

      yes, mainly control ON/OFF by extend wall switch panel, not by MCBs.

  • @hussainnawaz9641
    @hussainnawaz9641 Рік тому

    Good....we need your circuit diagram and code plxxx share it with us

    • @KinCony
      @KinCony  Рік тому

      all our diagram you can see here: www.kincony.com/forum/forumdisplay.php?fid=33

  • @waheedkhokhar5755
    @waheedkhokhar5755 3 роки тому

    You use back ground music if u stop music only you explain all connection so more help full for alls

    • @KinCony
      @KinCony  3 роки тому

      thanks for your suggestion, here is a video we have maken: ua-cam.com/video/B3RgOH_MGeQ/v-deo.html that we have explained details.

  • @darkshadowsx5949
    @darkshadowsx5949 4 місяці тому

    why would someone want a PLC for their house? whats so tedious that you would want to automate?
    does it wash the dishes, do your laundry, mow the yard, and cook for you?
    No? what the point then?
    automating lights isn't worth the cost.

  • @H1GH0CT8N3
    @H1GH0CT8N3 Рік тому

    Our company would like to specialize in your products and methods for IOT. How can we get training?

    • @KinCony
      @KinCony  Рік тому

      we have online training video play list: www.kincony.com/forum/forumdisplay.php?fid=18

  • @siderminerkgl8193
    @siderminerkgl8193 Рік тому

    Do you love to tidy stuff in casings?
    Do you like building robust mechanisms?
    Do you also like tech?
    Say hello to embedded systems engineering or embedded systems!

  • @shahzoddehqonov4935
    @shahzoddehqonov4935 Рік тому +1

    Zuda zoʻr

  • @matthijsthijssen3406
    @matthijsthijssen3406 2 роки тому

    Why you didn’t choose for a wireless solution, Zigbee based or so? Not necessary to wire your whole home to this central switch box…

    • @KinCony
      @KinCony  2 роки тому

      because wired solution is best stable. we will use a new way for switch panel connection, reduce wires number.

  • @hu2481
    @hu2481 Рік тому

    When you come in with AC L1 in one relais and then go 32 screw terminals to the last one, you have high connection resistance. Did you measure voltage drop under load?
    Use 4 or more feed ins and connect them in star topology.

    • @KinCony
      @KinCony  Рік тому

      yes, you are right, now using 8 pins together with power in.

    • @BTW...
      @BTW... Рік тому

      Poor advice from a non-electrician. Can't you see the gross design errors here?
      The only safe and professional way to do this is use a correctly rated (63A) manufactured and insulated copper busbar to connect the supply to all CB's... that then individually feed the contactors.
      A single 63A rated cable connects Main Switch to Busbar. Enclosed in a box that would be 16mm2 cable minimum. what's he using? Looks like 4mm2 solid core wire at the most... good for 32A.
      Note: No more than 2 conductors per terminal is what those CB and Contactor terminals are designed for anyway.
      Where are the Neutral and Earth bars with a minimum of 33 terminals for outgoing circuits?
      The enclosure is too small to accommodate sufficient segregation and cable management anyway.

    • @KinCony
      @KinCony  Рік тому

      @@BTW... this is a demo, most use for lamp, not use full current. if large current load need thicker wire.

    • @piotrkowalkowski7349
      @piotrkowalkowski7349 Рік тому

      @@KinCony doesn't metter what kind of load (lamps or anything else). Remember that CB must protect device AND CABLE - this is a principal rule. In case of some short circuits your contactors and wires are not protected, 63 A will burn out them.

    • @KinCony
      @KinCony  Рік тому

      thanks for your suggestion, next project will update.

  • @vicentecamilo5636
    @vicentecamilo5636 Рік тому

    Why didn't you use an electrical bus instead of cable jumpers?

    • @KinCony
      @KinCony  Рік тому +1

      now updated for use bus

  • @joshuadingle2761
    @joshuadingle2761 3 роки тому +2

    Hello sir! How much is the cost hardware not including the software?

    • @KinCony
      @KinCony  3 роки тому +1

      you can see our online store: kincony.aliexpress.com/ all our software is free.

  • @alimimuhammes5258
    @alimimuhammes5258 2 роки тому

    Hope not putting cooling fan wont damage the panel?

    • @KinCony
      @KinCony  2 роки тому

      it can work without fan

  • @AalimOnlineOfficial
    @AalimOnlineOfficial Рік тому +1

    7:11 why you did multi looping?

    • @KinCony
      @KinCony  Рік тому

      Load diversion for safer operation

    • @AalimOnlineOfficial
      @AalimOnlineOfficial Рік тому

      Multi looping is prohibited in good designs

    • @KinCony
      @KinCony  Рік тому +1

      @@AalimOnlineOfficial thanks for suggestion.

  • @Engineer1GH
    @Engineer1GH Рік тому

    Hello,
    That's beautiful! I want to give it a try. Could you share circuit and software with me?

    • @KinCony
      @KinCony  Рік тому

      next week, we will have new version circuit

    • @Engineer1GH
      @Engineer1GH Рік тому

      @@KinCony thanks a lot; looking forward to that

    • @KinCony
      @KinCony  Рік тому +1

      @@Engineer1GH ok, because we have released new smart controller, many new functions.

  • @sygad1
    @sygad1 Рік тому

    I would enjoy a follow up video where you explained it, watching the construction doesn't tell me a lot

  • @aljasiyaengineering1297
    @aljasiyaengineering1297 2 роки тому

    Can you upload video on Home Automation using Smart Station. Please

    • @KinCony
      @KinCony  2 роки тому

      Smart Station?

  • @yog-f21
    @yog-f21 Рік тому

    Mantab

  • @omegamix7750
    @omegamix7750 2 роки тому

    Thanks a lot 👍

  • @muzammilahmed8799
    @muzammilahmed8799 3 роки тому

    Nice Work done👍👍. I need the circuit diagram and it's specificications like what kind of MCB, chips and elcbs used. Can you please give me its detail.

    • @KinCony
      @KinCony  3 роки тому +1

      www.kincony.com/download/SMART-MAIN-DB-AUTOMATION.pdf

    • @BTW...
      @BTW... Рік тому

      No it isn't. Don't do it.

  • @Andrey0I
    @Andrey0I 9 місяців тому

    8:55 это место 100% первым выгорит. Жаль у вас нет тепловизора)

    • @KinCony
      @KinCony  9 місяців тому

      ua-cam.com/video/Ae4CDMBKRwA/v-deo.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description.

    • @Andrey0I
      @Andrey0I 9 місяців тому

      @@KinCony ua-cam.com/video/Ae4CDMBKRwA/v-deo.html да, тут уже все отлично.

    • @KinCony
      @KinCony  9 місяців тому

      thanks@@Andrey0I

  • @dharmapatel2235
    @dharmapatel2235 Рік тому

    32 channel means it can control only 32 different devices (On/Off) - correct? What if I have dimmable CCT lights? Also, how to connect this to Home Assistant that I already have?

    • @KinCony
      @KinCony  Рік тому

      yes, relay controller use for control 32CH ON/OFF, if you need dimmer, you can add KC868-D16 dimmer controller into DB, so that they can work in one software.

  • @paholovillagran1527
    @paholovillagran1527 Рік тому

    Muy bueno

  • @cristianantwi1212
    @cristianantwi1212 Рік тому

    i really wanna do this as my final year project what are the names of the components u used in doing this please help me out kk

    • @KinCony
      @KinCony  Рік тому

      thanks, many use our KC868-H32 series smart controller, this month have new hardware version, support alexa , google and apple homekit directly

  • @jasonmare33
    @jasonmare33 3 роки тому

    very cool!

  • @godfreyonyango512
    @godfreyonyango512 Рік тому

    Hi can you wirig of the lighting and auto gate please

    • @godfreyonyango512
      @godfreyonyango512 Рік тому

      Share wiring diagram showing the position of lighting ,dry switch and cable for auto gate.

    • @KinCony
      @KinCony  Рік тому

      www.kincony.com/forum/forumdisplay.php?fid=33

  • @janniemalan1597
    @janniemalan1597 Рік тому

    May i ask the diagram and software used for this awesome project please

    • @KinCony
      @KinCony  Рік тому

      you can download from kincony webpage: www.kincony.com/document

  • @crisptvevents681
    @crisptvevents681 2 роки тому

    wow nice project. please can it be controlled with amazon alexa?

    • @KinCony
      @KinCony  2 роки тому

      yes, it can

    • @crisptvevents681
      @crisptvevents681 2 роки тому

      Okay. Please is possible for you to do a video on that?

    • @KinCony
      @KinCony  2 роки тому

      @@crisptvevents681 ok, later we will make it.

    • @crisptvevents681
      @crisptvevents681 2 роки тому

      @@KinCony alright.. thank you

  • @josephtloumello2609
    @josephtloumello2609 Рік тому

    why does it not have Earth leakage that panel? how does it protect against earth fault?

    • @KinCony
      @KinCony  Рік тому

      if you want ,you can add it, this is a sample demo.

  • @traditional-vs-cultural
    @traditional-vs-cultural 3 роки тому

    Thanks

    • @KinCony
      @KinCony  3 роки тому

      you are welcome

  • @magayweryvan
    @magayweryvan Рік тому

    Woo!

  • @mohammadshawal2213
    @mohammadshawal2213 2 роки тому

    Hi sir , you can do smart air breaker DB box.

    • @KinCony
      @KinCony  2 роки тому

      yes, but we not change breaker structure.

  • @MrDenisJoshua
    @MrDenisJoshua Рік тому

    Witch software are you use in the mobile phone please ?
    Thanks for the video

    • @KinCony
      @KinCony  Рік тому

      now our newest controller can work with tuya app

    • @MrDenisJoshua
      @MrDenisJoshua Рік тому

      @@KinCony I don't like tuya... I like all my questions in my local area.
      Is this tuya on you phone please ?
      Thanks again

    • @KinCony
      @KinCony  Рік тому

      @@MrDenisJoshua ok, understand now, it can use kincony KBOX application in local network without internet.

    • @MrDenisJoshua
      @MrDenisJoshua Рік тому

      @@KinCony ok Thanks a lot for the answer.

    • @KinCony
      @KinCony  Рік тому

      @@MrDenisJoshua you are welcome

  • @dineshsingh-gb6un
    @dineshsingh-gb6un Рік тому

    2017 ke bad lenevo thinkserver kyu nahi aaye purane hi kyu bik

  • @kofikwofie
    @kofikwofie Рік тому

    please where can i get the materials to buy and diagram

    • @KinCony
      @KinCony  Рік тому

      you can from our online store: kincony.aliexpress.com/store/1100463977
      all diagram download at here: www.kincony.com/forum/forumdisplay.php?fid=33

  • @omumaro
    @omumaro Рік тому

    Why do you use C breakers and not B?

    • @KinCony
      @KinCony  Рік тому

      mainly use for light. here is our new solution: ua-cam.com/video/Ae4CDMBKRwA/v-deo.html this is improvement.

  • @r_candlejustice4915
    @r_candlejustice4915 Рік тому

    I am very interested in your video. Can I get the physical wiring information or electrical drawing? I would like to apply home IOT to my parent's house.

    • @KinCony
      @KinCony  Рік тому +1

      you can download from our webpage, now we will make a new video tour with the newest function soon.

  • @maxphipps2
    @maxphipps2 3 роки тому +27

    Not much smart in 32 on off switches. Good to see how not to build a breaker panel though.

    • @LouieCastro3
      @LouieCastro3 3 роки тому +1

      Yea those massive jumper chains look awful

    • @KinCony
      @KinCony  3 роки тому +3

      now we are using new jumper, will take new video later.

    • @BTW...
      @BTW... Рік тому

      Yeah, pretty dumb in many ways. I say not good to see someone with no idea on how to design and fabricate a non-compliant SCA with the intent of instructing others!
      Count the number of morons that think it's all "good work" and 'fans' who have even less idea.
      I just pity the Emergency responders that have to attend a fire or electrocution as a result of dumb ideas like this.

    • @HobbyFinn2
      @HobbyFinn2 Рік тому +5

      I think it’s neat, BUT is’n all the current for every single braker going through the first screw terminal?! 32x10A……320A on a single screw terminal. Worst case. I smell MAGIC SMOKE…

    • @BTW...
      @BTW... Рік тому +4

      @@HobbyFinn2 Correct regarding the string connection of supply Active to each sub circuit. EVERY dodgy looping in that panel is problematic. On that type CB the clamp is designed for little more than 32A, because that's the max rating of those CB's, when properly installed. That involves using rigid pressed copper busbar that maybe rated to carry 160-225A total loading which also directly connects to the 2 pole 63A rated Main Switch (it's not a CB... just an isolation switch). Your calculation of 32 x 10A = 320A isn't correct because this panel would be fed from an overcurent protection device (Fuse or CB) at the Main Distribution panel in the building.... but maybe not if some dodgy idiot connected it up. That fuse or CB's rating should be no more than the rating of cable to this panel AND the rating of the Main Switch. Who knows what he has used. Further, he has used small gauge low current rating solid wire for the looping and connection to Main Switch that is only good for 32A... some looping there using lower gauge wire is only rated for 10A.
      BUT LOOK closer.. that unswitched active loop feeds to every CONTACTOR (that has a even lower designed current rating) that then feeds individual CB's. This "neat" fire hazard is wired back to front!
      In any case, I first look at the Earthing/Grounding circuit, which is most important to protect life... and that fails Standards.
      Further major design flaws present.
      The Control power supply (for PLC and contactor switching operation) that is fed from Main Switch should be protected by it's own 2-10A fuse or CB. Without that the control wiring at mains potential under fault condition (which could happen inside the PLC or any relay switched contactor or low voltage power supply in that enclosure) is 'protected' at a current rating of the fuse or CB in Main Switchboard. Could be 63A... only needs to be 16A to 32A max if that thing is only controlling lighting circuits... more if general power circuits for appliances... and a lot more if controlling high demand loads like fixed heating too.
      At least he made it easy to isolate any wireless control to the panel. All you need to do is close the metal door of the Faraday Cage enclosure! LOL

  • @johnkosheluk1041
    @johnkosheluk1041 Рік тому

    and when something goes bad how do you replace it with all the wires on it

    • @KinCony
      @KinCony  Рік тому

      there is manual control button.

  • @joelcalaminos8259
    @joelcalaminos8259 2 роки тому

    Where we can buy supplies in the Philippines? Thanks

    • @KinCony
      @KinCony  2 роки тому

      you can order from our online store: kincony.aliexpress.com

  • @iqking2828
    @iqking2828 2 роки тому

    With this set up it is not possible to control much load, no?

    • @KinCony
      @KinCony  2 роки тому +1

      just add controller will control much load.

  • @sethtetteyannan
    @sethtetteyannan 2 роки тому

    Please what of type of circuit breaker did you use? I see another attachment to it?

    • @KinCony
      @KinCony  2 роки тому

      middle row is contact, the breaker just traditional MCB

  • @MrRajSood01
    @MrRajSood01 3 роки тому +1

    Big fan of your work !!! Keep up the
    Good work

    • @KinCony
      @KinCony  3 роки тому

      thanks, we will make more interesting applications

    • @BTW...
      @BTW... Рік тому

      Seriously?

    • @richardswairg3695
      @richardswairg3695 Рік тому

      @@BTW... give him a break bro he said he made this project for fun 😅

    • @BTW...
      @BTW... Рік тому

      @@richardswairg3695 Lets say... between the two.. a 'how to' DIY no idea 20kg batch of black powder fireworks, stored in every room of the house, or this 'how to' DIY no idea mains voltage (240V AC 40A @ 10kA pfc) switchbox fireworks, permanently connected to a home or commercial building.
      Now, what do you think would be more fun and safer?
      ...and it follows, Do you think demonstrating either of these highly dangerous 'DIY fun' things is suitable for UA-cam promotion?

  • @thebestever2851
    @thebestever2851 Рік тому

    What type of microcontroller are you using?

  • @MooshyVR_gorrila
    @MooshyVR_gorrila Місяць тому

    Cool but if i turn off the power my i ternet wont work so i cant turn it back on 😂😂😂😂😂😂😂😂

    • @KinCony
      @KinCony  Місяць тому

      use two different channel.

  • @TheTIAHUB
    @TheTIAHUB Рік тому

    Sir what is the range of controlling to this panel?

    • @KinCony
      @KinCony  Рік тому

      anywhere, just have internet.

  • @bagyamadushan34
    @bagyamadushan34 3 роки тому +1

    Hi..
    Do you have a distributor in sri lanka?

    • @KinCony
      @KinCony  3 роки тому

      no, need send product by express

  • @bamideledavid8769
    @bamideledavid8769 Рік тому

    Can you please share the circuit diagram?

    • @KinCony
      @KinCony  Рік тому

      circuit diagram in the video description

  • @ahmedgholoumbinali6905
    @ahmedgholoumbinali6905 2 роки тому

    Is the contactor necessay? , can i make it with just mcb , cb, kc868 , 12v cb and switch terminal only?, i mean what is the used of cobtactor?

    • @KinCony
      @KinCony  2 роки тому

      contactor main control large current load. if only use by smart controller's relay , not use for large current, add a contactor will be safety.

    • @kacoeng
      @kacoeng 2 роки тому

      Does the contactor function same as relay? So there will be current flow in the coil of contactor to close the contact just like relay?

    • @KinCony
      @KinCony  2 роки тому

      @@kacoeng yes, like a relay, but suit for large current, such as 25A,40A,.....

    • @BTW...
      @BTW... Рік тому

      If you need to ask this question you SHOULD NOT be doing this type of work.

    • @BTW...
      @BTW... Рік тому

      @@KinCony Use of correctly rated switchgear aside.... what you have fabricated is NOT SAFE.

  • @DocMacLovin
    @DocMacLovin 2 роки тому

    Is it possible to direct drive DC valve motors (for floor heating) forward and backward on the output terminals? Can you show how to integrate the controller with Home Assistant?

    • @KinCony
      @KinCony  2 роки тому

      if connect with large current load, suggest add AC contactor. controller can work with home assistant by MQTT, we have video tour: ua-cam.com/video/Yrat7hVzXRw/v-deo.html

    • @BTW...
      @BTW... Рік тому

      @@KinCony Use an AC contactor for a "large current" DC load? Seriously?

    • @BTW...
      @BTW... Рік тому

      The correct answer is.. Yes, if a forward AND reverse function contactors are used. That will use 2 control output channels of the PLC instead of 1only. 3 states of operation... Forward / OFF / Reverse.
      Check to see if the valve motors need to be de-energised after full travel actuation. i.e. if there is internal switching that disconnects applied control signal so the motor doesn't keep running after achieving a full open or close position.
      Use contactors/relays designed for use on DC... not AC, unless you enjoy replacing faulty equipment.

    • @KinCony
      @KinCony  Рік тому

      @@BTW... if you want use DC load, just replace with contact for DC version, there are many contact type can be used, just according to "load type".

    • @freundderuc9146
      @freundderuc9146 Рік тому

      @@BTW... even worse, breaking an inductive load generates an eletric arc which regular AC contactors aren't designed for. You definitely need a device with spark extinguishing chamber, otherwise your contacts are burnt down pretty fast and as a result the contacts may stick

  • @benoitpesesse9773
    @benoitpesesse9773 2 роки тому

    Connecting red and blue cables together !?

    • @KinCony
      @KinCony  2 роки тому

      what time showed?

    • @benoitpesesse9773
      @benoitpesesse9773 2 роки тому

      @@KinCony 8:56

    • @KinCony
      @KinCony  2 роки тому

      @@benoitpesesse9773 i see, that is "N" line. maybe the AC contactor teminal use blue is better.

  • @hammadjathar6558
    @hammadjathar6558 Рік тому

    hello i hope you are fine
    Can you send me complete code and circut diagram

    • @KinCony
      @KinCony  Рік тому

      ua-cam.com/video/Ae4CDMBKRwA/v-deo.html this is 2023 newest smart distribution board DIY video tour, have diagram download link in video description

  • @rantungsampouw9099
    @rantungsampouw9099 Рік тому

    This is Great. Thank you!

  • @jeremykromah9267
    @jeremykromah9267 Рік тому

    how you did it??

  • @user-jm1bm1kd3y
    @user-jm1bm1kd3y 4 місяці тому

    Във производството на зъболекарски кабинети има един от многото му прости "детАйли" един прост, който се нарича "щуцер".....💧.📍.💦. 🦄 ....колко са операциите на един стругар за изработката му като "краен продукт"....

  • @eliomargoncalves
    @eliomargoncalves 2 роки тому +1

    Eu quero trabalhar com essa tecnologia (Casa Inteligente).

  • @adilibrahim375
    @adilibrahim375 2 роки тому +1

    iot is good , but no proper channel duct , no lugs , no proper main wire distribution , you may need to learn more about electrical . otherwise i see some burning smell from your this panel .. ;)

    • @KinCony
      @KinCony  2 роки тому

      thanks for suggestion, the new verison many have updated.

  • @wes89
    @wes89 2 роки тому

    Lose the audio, speed the video up and get the thought across.

  • @crypto2own811
    @crypto2own811 2 роки тому

    Can you also install 32 push button switches for controlling besides the APP?

    • @KinCony
      @KinCony  2 роки тому

      yes, support.

    • @crypto2own811
      @crypto2own811 2 роки тому

      @@KinCony Can the push switch with LED to indicate is ON?

    • @KinCony
      @KinCony  2 роки тому

      @@crypto2own811 yes, no problem, it can feedback relay state.

    • @crypto2own811
      @crypto2own811 2 роки тому

      @@KinCony Which module controller will work with HomeKit? I need to contol 48 devices.

    • @KinCony
      @KinCony  2 роки тому

      @@crypto2own811 KC868-H32BS is best, another you need add a raspberry pi.

  • @supandi100
    @supandi100 3 роки тому

    i wanted to buy all these divices and make myself distribution boardwith IoT controller…pls give me address for placing order from India..
    DO YOU HAVE AGENT IN INDIA.?

    • @KinCony
      @KinCony  3 роки тому

      you can add us whatsapp number:+86-15381188302 we make online order for you by alibaba.com. now no agent in India.