How to re-pressurising expansion vessel on an Ideal Logic boiler step by step

Поділитися
Вставка
  • Опубліковано 15 вер 2024
  • How to re-pressurising expansion vessel on an Ideal Logic boiler step by step
    This video is for GAS SAFE ENGINEERS only, always follow manufacturer instructions.
    Before to start any work on gas appliance isolate the power, turn off the gas and the waters.
    1. Remove front cover
    2. Download manual
    idealheating.c...
    3. Drain the boiler
    4. Connect compressor to expansion vessel
    5. When the boiler pressure drop to 0 bar you can re-pressurise the expansion vessel till 1 bar.
    6. Make sure you leave open the drain point.
    7. When the boiler pressure is 0 bar, the drain point stopped and the expansion vessel pressure is 1 bar, then it's done.
    8. Remove the compressor.
    9. Close the drain point.
    10. Re-pressurise the heating system till 1 - 1.5 bar.

КОМЕНТАРІ • 8

  • @fredthesavannahcat2899
    @fredthesavannahcat2899 2 місяці тому

    No ldf on the schrader valve?

    • @bheating
      @bheating  2 місяці тому

      Yes, you have to test to make sure is not letting by.

  • @paulbentley849
    @paulbentley849 5 місяців тому

    My expansion vessel label say precharge is 0,75 +0,2 bar can u help me the pre-charge expansion vessel pressure

  • @paulbentley849
    @paulbentley849 5 місяців тому

    U didn't close the flow and return valves

    • @bheating
      @bheating  5 місяців тому

      Yes, I didn't isolated because the boiler was on top floor the highes point of the heating system.

    • @ashleybone342
      @ashleybone342 4 місяці тому

      So if you had had to do that, is it the 2 black valves on opposite ends of boiler to isolate them?

    • @bheating
      @bheating  4 місяці тому

      @@ashleybone342 Yes