IDEAL LOGIC BOILER SERVICE - How To Service An Ideal Logic Boiler

Поділитися
Вставка
  • Опубліковано 9 лют 2025
  • IDEAL LOGIC BOILER SERVICE
    Do not attempt unless you are Gas safe or under the supervision of someone Gas safe. Attempting this without a Gas Safe ID can be dangerous to you and people around you.
    This is aimed at people who don't service much, new to this boiler or trainees.
    All this information is already widely available.
    MAKE SURE TO SUBSCRIBE TO GET FIRST DIBS IN COMPETITIONS AND SEE BRAND NEW VIDEOS COMING SOON!
    See my channel for more boiler goodness, including the, 'how to put boiler into service mode' series.
    Subscribe and click the bell to see new videos!
    Don't forget the service basics, visuals, terminations, ventilation, electrically isolated correctly, gas rates, working pressure, clean the electrodes.
    This video will show you how to fully service the ideal logic boilers.
    . - check your MI for individual readings for output and model.
    If there is a particular video regarding gas boilers you would like to see, please comment below
    THANKS FOR WATCHING!

КОМЕНТАРІ • 66

  • @davidobrien6667
    @davidobrien6667 5 років тому +6

    U should tell people about the little crack that can appear on logics when u take the sump cover off on the top right hand side. Easy to miss and its AR

    • @goldgas1216
      @goldgas1216  5 років тому +6

      Pinned! Very useful.
      I should of mentioned it and I was meant to, but only realised when I finished the video. Gonna do more ideal videos, so will get it in there.
      Cheers for watching mate! 👍

    • @bellagio1066
      @bellagio1066 4 роки тому +1

      Yep mine had the hairline crack and flooded the whole base of the boiler. Be careful to get the correct part. My engineer came out and fitted one that had the connector on the side rather than below so basically had to snap it off and refit the correct one the following day. It was a pricey lesson learnt.

  • @miwka40
    @miwka40 3 роки тому +6

    Excellent service. You doing the way service must be done. I had half a dozen boiler services in my property and the gas engineer max spent 20 minutes. They don't check everything as you do.
    They don't even clean/remove limescale build up in the clear filtering box/tube

  • @barrylumsden6331
    @barrylumsden6331 3 роки тому +2

    Couldn't have done the job better myself. Good to see a true professional at work 👍

  • @SalimKhan-gk1fh
    @SalimKhan-gk1fh 5 років тому +6

    Well done on cleaning and flushing out the heat exchanger
    you must be one of the few of the engineers who actually bothered to do it !
    Believe me I have seen a few that have not been done

    • @goldgas1216
      @goldgas1216  5 років тому +2

      Cheers mate, appreciate that. 👍
      It don't take long at all on this boiler. I just do the job I'd expect if I was paying for it

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 5 років тому +1

      Gold Gas Videos No problem it’s nice to see engineers out there who do the proper job
      trust me I have not seen many cleaned at all and you can always tell when they’ve never been apart

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 5 років тому +1

      Gold Gas Videos , Keep up the videos mate they’re really enjoyable to watch
      Just out of interest what brand of boiler do you have at home?

    • @goldgas1216
      @goldgas1216  5 років тому

      @@SalimKhan-gk1fh appreciate you saying pal. Means alot.
      My boiler is (not by choice) ideal icos. Nothing wrong with Ideals, but the icos /isar boiler is not my favourite.

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 5 років тому

      Gold Gas Videos yes nothing wrong with ideal, the later logics ,mini and independents all proven to be reliable enough
      The odd cracked sump and flow turbine but ok in general, my Combi at home is a viessmann by choice
      Got the vitodens 100 and I’m over the moon with it!🙂 viessmann also my first recommendation to customers

  • @blastfromthepastism
    @blastfromthepastism Місяць тому

    Thanks for making and sharing mate 👍

  • @ismails8155
    @ismails8155 7 місяців тому

    Thanks mate, explained in detail, very helpful

  • @Abulsuny
    @Abulsuny 3 роки тому +4

    Fantastic very professionally explained
    Wish this gentleman can service our logic combi boiler which is being a nightmare for us l2 f2 all the time 😔
    Had it serviced over a year ago but think we have been cheated by this boiler man.😔

    • @Bestperformancecars
      @Bestperformancecars 2 роки тому +1

      Change your electrode. I got it for £15 online.

    • @Abulsuny
      @Abulsuny 2 роки тому +1

      @@Bestperformancecars Thanks mate did works great 👍

    • @Bestperformancecars
      @Bestperformancecars 2 роки тому

      @@Abulsuny if the f2-l2 appears again within weeks , then the heat exchanger is filled with carbon deposit you will bees to flush it with water as seen in the video. But you should change the heat exchanger gasket.
      Mine has the same problem. I didn't get time to clean the heat exchanger but i keep cleaning the electrode with sand paper..
      Best of luck.

  • @sudhiradhikari19
    @sudhiradhikari19 3 роки тому

    First time came across your video, very informative, thank you.

  • @CorneliusOSullivan-n8y
    @CorneliusOSullivan-n8y Рік тому

    Great help we'll done

  • @MaxEpsom
    @MaxEpsom 10 місяців тому +1

    Do you have to replace the gaskets when you talk fan off and main heat exchanger off

  • @raihankhan5638
    @raihankhan5638 3 роки тому

    Thanks mate it’s really helpful tips

  • @maxwebster1863
    @maxwebster1863 Рік тому

    Would you hover your analyser round the burner gasket to make sure its sealed correctly ie zero on readings ?

  • @aidensholeh3696
    @aidensholeh3696 3 роки тому

    Great video thanks mate!

  • @2009bager
    @2009bager 2 роки тому

    Good service, many engineers just clean the condensing and do FGA.

  • @candymanoooooo
    @candymanoooooo 11 місяців тому

    Just has our boiler serviced by heatforce who fitted the boiler 3 years ago and they didnt do half of what you did when they serviced it as i was there the whole time, it has a TF1 Sigma filter should he cleaned this as he didnt do anything we paid a lot for the service and he didnt seem to do much for the ammount we paid

  • @1000Mikey
    @1000Mikey 5 років тому +2

    Top job. I've heard the spacing between the two electrodes is about the same size of a pound coin.

    • @goldgas1216
      @goldgas1216  5 років тому +3

      Bang on it mate. Easier than a tape haha. Cheers geez 👍

    • @rayc1503
      @rayc1503 5 років тому

      @@goldgas1216 you can give the electrodes a good file all around. It should keep on continuity from point to point. I have in the past heated the tips until they're cherry red and straightened them. Yeah spacing is as much as pound coin.

    • @goldgas1216
      @goldgas1216  5 років тому

      @@rayc1503 defo on the file all around, haven't tried heating and bending it. Will defo try, haha if it breaks I'm blaming you😂

  • @Ryanj82
    @Ryanj82 4 роки тому

    Fantastic boiler to work on.

  • @rayc1503
    @rayc1503 5 років тому +1

    I use a garden spray bottle with the manometer hose attached to sparay out the heat engine. It's also great for filling up the condense trap before you put the top rubber hose back on. Infact it's great for a multitude of different applications. 😁Always as usual great content pal. 😉

    • @goldgas1216
      @goldgas1216  5 років тому

      Oh wise dude. 🙌🙌 Cheers mate. Great advice too mate, will give the hose on my sprayer a go. 🤟👍

  • @nobs6004
    @nobs6004 3 роки тому

    We have this boiler and it has an issue with hot water. The boiler fires up when a hot tap is turned in the bathroom but it will shortly go off again like the boiler does not see a demand for the hot water anymore. However, if we put 2 hot taps on at the same time the boiler will stay firing and give us hot water. As soon as one tap is turned off the water on the remaining hot tap will turn cold. Any ideas? Central heating works fine

  • @abdulh63
    @abdulh63 4 роки тому

    great service!

  • @wesleybushell3215
    @wesleybushell3215 2 роки тому

    If I get boiler cover and he uses utube should I cancel them

  • @jaimedamascena1142
    @jaimedamascena1142 4 роки тому

    Great video, where do you take your inlet pressure, appliance gas valve or gas cock valve test point?

  • @tambias
    @tambias 4 роки тому +3

    Great thorough job.try doing 9 a day!

  • @jonwillock3594
    @jonwillock3594 4 роки тому

    How much do you charge for a service like this on a logic?

  • @tk4270
    @tk4270 9 місяців тому

    We had groaning noise each time boiler fired up, which has now disappeared after engineer from Ideal replaced burner because we weren't getting any hot water.

  • @ParkesPlumbing
    @ParkesPlumbing 5 років тому +3

    Nice one bro .. proper job

    • @goldgas1216
      @goldgas1216  5 років тому +1

      Cheers mate, love a comment from the big dog! 🐶👍👍👍🍻

  • @malcolmclarke2832
    @malcolmclarke2832 8 місяців тому

    That's a proper service there, cheap engineer just checking operation and clean trap

  • @sodig876
    @sodig876 5 років тому +1

    Good informative video 👍 how often would this type of service be required?

    • @goldgas1216
      @goldgas1216  5 років тому +4

      Every year mate, tbh seals rarely need changing and if they do it's usually the once. You can get the whole boiler apart in 10 mins. Great boiler to work on if I'm honest 👍 and thank you mate, appreciate it

    • @livingwithouthair2185
      @livingwithouthair2185 4 роки тому +1

      @@goldgas1216 you wouldn't get time to do all that if working on social housing

    • @goldgas1216
      @goldgas1216  4 роки тому

      @@livingwithouthair2185 oh really that sucks mate, you gotta do what you gotta do

  • @salamabegum8289
    @salamabegum8289 3 роки тому

    I got a problem with my boiler, when I turn the heating on it leaks and we had no hot water so we had the flue manifold changed which cost us £120🙁 but it is still leaking so we were told to have a new heat exchanger filter which will cost £300-£400 and my boiler is only 3 yrs old 😭😭now we can’t turn the heating on because of the leak

  • @williammcgrattan9583
    @williammcgrattan9583 5 років тому +1

    No mag filter on?

    • @goldgas1216
      @goldgas1216  5 років тому +2

      No mate, wasn't one on this baby

  • @xiaoye6423
    @xiaoye6423 3 роки тому

    Hi, friends,how much the fix cost?where are you ?

  • @stevedavies8703
    @stevedavies8703 4 роки тому +1

    Great lesson to stay away from fitting Logics

    • @timhancock6626
      @timhancock6626 2 роки тому +1

      Logics are brilliant and easy to service and fix. They are pretty reliable and they've sold nearly 4 million. I've had a heat only 18 for six years, no problems. I used to fit them before I retired. None of mine needed sumps though I have fitted sumps to early logics. I hardly had any warranty calls on them. Customers like them, job done.

    • @petegasguy
      @petegasguy 2 роки тому +3

      @@timhancock6626 sold nearly 4 million of them because they knock ‘em out to major developers for £300 each 😂

  • @worldstarepic9942
    @worldstarepic9942 2 роки тому

    I have had my boiler serviced many times but not like this at all!

  • @andrewknipe4261
    @andrewknipe4261 Рік тому

    great Job pal. nicly done

  • @jasonbrooksbank
    @jasonbrooksbank 4 роки тому

    Did one today took 1hr.45 mins. What a pain.

  • @irr834
    @irr834 2 роки тому

    Hola te querría preguntar cuanto tardas en hacer una revisión así y cuantas haces al día ?gracias amigo.

  • @robinmyman
    @robinmyman 4 роки тому

    Answer to an Ideal boiler...scrap it and fit a Viessmann.
    Design fault in heat exchanger...mine lasted 2 years from new.
    Replacement warranty one year not ten.
    Ideal will not guarantee their boilers for ten years unless it was fitted from new with their own brand filter.
    Avoid.

    • @timhancock6626
      @timhancock6626 3 роки тому +1

      That's nonsense. I've had two warranty calls on the Logics I fitted. The rest have been fine and the first one I fitted was ten years ago. I have one at home since 2016. I've changed one sump on a very early model somebody else fitted locally. I've seen far more Worcester Bosch heat engine failures. You do know there are over 3 million Logics out there now and for the most part they are pretty bullet proof and dead easy to service properly. Viessman electronics fail in my experience though they have recently dropped the price of control units/ boards.

  • @dougbushell7277
    @dougbushell7277 2 роки тому

    I had a boiler service all he done was check gases with a meter and cleaned magatec filter. Take 10min £60 what a rip off