  • Working with WS2815 or any other digital pixel LED strip that has Backup data? In this short video, we will show you how we are connecting this type of strip. For those that are working with our LED Ethernet Controller 3 or SPI Matrix, the D/B pin on the Output is not the Backup data.
    BUY ARTNET UNIVERSES NOW - ledstrip.studio/ArtNet-Price-List
    LED Strip Studio is brand dedicated to development of progressive LED technology, LED controllers and LED accessories. We truly have strong tradition of successful projects and happy clients all over the world. Something about the merest beginning of this brand, achievements, and aborts also, you can find on our blog
    BLOG - ledstrip.studio/go-to-blog
    PAGE - ledstrip.studio/visit-us
    Follow us on:
    FACEBOOK - / ledstripstudio
    INSTAGRAM - / ledstripworld
    TWITTER - / ledstripstudio
    #ledstripstudio
    Any questions? 👀 Let us know in the comment section!
    email: info@ledstripstudio.com
    phone: +421 220 283 002
  • Розваги

КОМЕНТАРІ • 10

  • @MichaelKochSchulte
    @MichaelKochSchulte Рік тому +1

    I have a recently acquired a strip that is labelled "FI FO" instead of BI. It seems to be the backup line as it runs the LED light program for either line. The distributor recommended that I tie the data DI and FI together. FYI, the product is a 10m length of 24v "flex" strip light.

    • @LEDStripStudio
      @LEDStripStudio  Рік тому

      Best practice, for us, is to connect the Backup data on Ground. Which IC is this? Curious about the labeling. Never encountered such strip, yet it happend a few times that the producer simply decided to use their own marks :)

  • @butineloi8778
    @butineloi8778 2 місяці тому

    Hey, can you give me DMX 512 to the SPI decoder which can work with this LED group (WS2815), I try to create a DIY pixels mapping but it's always difficult for it to work. Thank you for this video she helped me

    • @LEDStripStudio
      @LEDStripStudio  Місяць тому

      Our small SPI LED controller can convert DMX512 to any SPI signal (including WS2815): www.ledstripstudio.com/spi-led-controller/

  • @damichl9684
    @damichl9684 Рік тому +1

    Thank you very much for the good video. But what is the point of the backup pin? is this there for the fact that if an LED breaks, that the signal is then looped through?

    • @LEDStripStudio
      @LEDStripStudio  Рік тому +2

      Hi, yes, the purpose of the backup is when one LED diode dies, the second one after the broken one will work.

  • @dankaufman8900
    @dankaufman8900 Рік тому +3

    Why couldn't you connect the backup data to the original data line?

    • @LEDStripStudio
      @LEDStripStudio  Рік тому +5

      Because that would shift the image data. The backup line should remove first LED from the data you send, but we don't do that in the controllers. You would need to generate whole new signal, which doesn't contain first LED to be correct. Anyway, our experience - the backup never works well.

  • @grupasc
    @grupasc 8 місяців тому

    Czyli takie podłączenie spowoduje ze kopia zapasowa będzie działać bez problemu tak ?

    • @LEDStripStudio
      @LEDStripStudio  7 місяців тому

      Tak :) though it is worth noting that this is for the strip type that we are using.