These columns can bear 5 stories, The column design is over specified Its is not economical also design should make as per thickness of walls like 8x18 inch or 8x24 inch would be much better.
You're right and he is right too, this column can hold 5-6 floor easily in resident building but as he said this one is for commercial building which mean live load is many times higher than the resident's live load so 3 floor in commercial is easily equal to 5 floor in resident
@@Deepakyadav-jk5km if the span distance between two columns is higher , then it's acceptable or reasonable to add number of steel rods, but looking at the site the columns are closely arranged and the rooms are not that bigger. Not a proper design
It will be much better if the bottom of plinthbeam atleast 3inches below ground level to avoid seepage of water into basement during heavy rain and the entry of rats through bottom of beam
Hello sir, Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..? The column to column distance is 15 feet. How many storeys can be built with this much reinforcement..?
Assalamo alaikum I made a structural design of 3 storey domestic building as per IS code in my design column size is 230*230 with 16mm 4 baar and bindup it with 8 mm ties by calculation it can bear the load so it's right or not please comment Thank you
I want to have 15 feer distance from column to column or( 16 feet center to center of column), using 9"x15" size column. 1 is it OK? 2. What size and number of steel bars are advised?
Sir 1200 sq ft m ghar bnana h mujhe..3 manjil building bnane k liye pillar ka size 10"x10" de skte h with 6 rods of 12 mm. Distance between two pillars is 10 feet.. Total 12 pillars h.. Please mera reply kre ❤💯🙏🏼🙏🏼🙏🏼🙏🏼
Sir in my house contractor is using 20 columns but in 6 columns span is 18.5 feet, 19 feet. Is column spain is right. Column size is 9×14 and bars used are 16 bars. 16 mm are 4 bars and 12 mm are 2 bars. And plinth beam size is 9×18 can I go for G+2 with this structure
Thumbs rule: Never make decision on how big and how many bars to use for your house/building if you are not a trained structural designer. Buildings are most likely different from each other. Hire a prof structural engineer, be safe and save money.
Sir, distance b/w two columns 18ft, and column 9*12inch, pl suggest sillbeam, rcc and beam reinforcement details, construction area 30*40 ft (can I send plan sir)
My contractor has give 25feet distance between two pillars. He has used 9x18 pillar size with 8 pieces of 16mm tmt bars. Beam size is given as 9x24 with 6 pieces of 20mm bars. It is a G+2 residential building. Is it ok ?
These columns can bear 5 stories, The column design is over specified Its is not economical also design should make as per thickness of walls like 8x18 inch or 8x24 inch would be much better.
You're right and he is right too, this column can hold 5-6 floor easily in resident building but as he said this one is for commercial building which mean live load is many times higher than the resident's live load so 3 floor in commercial is easily equal to 5 floor in resident
Rightly said, too much usage of steel for 3 storey building, even if it's commercial this specification has been exaggerated
@@Deepakyadav-jk5km if the span distance between two columns is higher , then it's acceptable or reasonable to add number of steel rods, but looking at the site the columns are closely arranged and the rooms are not that bigger. Not a proper design
@@valentinovictor what if they have to put tonns of metal ore in it, all the theories is worthless in commercial everything should be extra
Liked all arguments you guys. Very educative to us beginners. Thanks
Thanks for sharing sir and this vedio...new friend from Phillipines
It will be much better if the bottom of plinthbeam atleast 3inches below ground level to avoid seepage of water into basement during heavy rain and the entry of rats through bottom of beam
It is very useful for common peoples. Jayachandrareddy
New subscribed from Somalia
Good job I love Civil Engineer
Thanks for beautiful information
Very knowledgeable video. Thanks
Very good explain.
Thanks For Teaching Sir
Wow that's nice job and good work
Jazzakallah Khairan brother
It's good. Keep it up.
Could you please share the video of this building current status… completed building video… thanks
Nice and informative
Sir this plinth beam alignment out not proper work because plinth beam is zigzag?
I'm just a random guy but I can see all the rebars are cut at same height .
Is this acceptable ?
No... it's not acceptable...
I am using 9 X 18 column size distance between two columns 20feet .. so which size using beams and bars
Is this same reinforcement continue to the last floor
Verygood
3 storey building heavy steel bar therw is no diamond stirup
Good job
Please explain about domestic building
Using 20mm rods, that too for 12 numbers, is way too much , not a feasible cost effective design
Yes bro 16mm with 12nos is more then enough
Over designed column
For G+2 6 no 16 mm is sufficient
@@kgmanjunatha4849 what about G+3
Sir iron will get rust , after some years. Can we use steel instead of iron for pillars.. .
What about the iron for the floor where it is tied... Sorry I just learned
fine
Waalaikum Salam warohmatullohi Waabaraqatuu🙏🙏🇮🇩
Sir, you are very sincere!👍
Hello sir,
Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..?
The column to column distance is 15 feet.
How many storeys can be built with this much reinforcement..?
Sir i want to know about septic tank for house best
ಈಶಾಣ್ಯ ಮೂಲೆ
Perfect
Assalamo alaikum
I made a structural design of 3 storey domestic building as per IS code in my design column size is 230*230 with 16mm 4 baar and bindup it with 8 mm ties by calculation it can bear the load so it's right or not please comment
Thank you
23x45 would have been much better
Are 8 bar use krte bro
If there is one basement one ground and 4 more stories,total 6 then what should be the column beam structure
Perfect job
I am using 9" X 15" column for 19 feet horizontal span So What can be the distance between two column vertical span for G+2 building
16mm - 4bars 12mm-4bars
Steel percentage should be maintained
What is your beam size?
@@devapratimbaishya 9 x 15 inch
@@shrayanshjha8109 it's fine , where are you from?
I want to have 15 feer distance from column to column or( 16 feet center to center of column), using 9"x15" size column.
1 is it OK?
2. What size and number of steel bars are advised?
same question
16mm Longitudinal would have been enough
What is the size of footing and steel reinforcement details.
same question
What about if I need Reinforcement columns? The measurements will be the same?
Notice no construction joints for beams and columns.
Hola amigo sebe una estructura muy bien y fuerte como para hacer 5 o 6 alturas 🇪🇸👍💪
Sir, between coloum Max allowed length please
sir how distance in 2 coulumn in three story buillding you prefferd. plz reply
I love tutoring I hope I will contact you someday
Sir from the starting show
Sir 1200 sq ft m ghar bnana h mujhe..3 manjil building bnane k liye pillar ka size 10"x10" de skte h with 6 rods of 12 mm.
Distance between two pillars is 10 feet.. Total 12 pillars h..
Please mera reply kre ❤💯🙏🏼🙏🏼🙏🏼🙏🏼
16 is better
Number of bars and column sizes way too beyond required standards depending on floor loadings and number of floors
Dear, How do I buil G+2 Building using 9"x12" column size
What is an inch in technology
Detail grade beam
Latak Beem kitne inch ka hoga our
Rencforment kya hogi
Sir what is your distance from one column to the other?
18ft
Sir why the Brickwork foundations nearly plot too much deep where you use third class brick?
Lap zone in column should be the middle portion
Quá chắc, xây bao nhiêu tầng hả cụ
Please details of steel in beam
Sir in my house contractor is using 20 columns but in 6 columns span is 18.5 feet, 19 feet. Is column spain is right. Column size is 9×14 and bars used are 16 bars. 16 mm are 4 bars and 12 mm are 2 bars. And plinth beam size is 9×18 can I go for G+2 with this structure
you can...
Centre to centre distance between columns not given
what is the column size
Dy column da pasa beem size ba sa razi
سٹیل کے ساتھ جو کنکریٹ لگی ہوئی ہے اس کی صفائی بہت زیادہ ضروری ہے
No dpc work for ground
Sir it is learning of construction process. So this is not structure or column design learning or thiury.
Hight of column from plinth beam.pls mention sir,,,🙏🙏🙏🙏
Beam boht zeyada day deye hain ap nay.... Kam b day saktay thay
Total rod how much per sqft
Sir can I make colomn in plinth beam?if not make in foundation for 2 storey house?
What is size of plinth beam
What about the beam
Thumbs rule: Never make decision on how big and how many bars to use for your house/building if you are not a trained structural designer. Buildings are most likely different from each other. Hire a prof structural engineer, be safe and save money.
True. Safety and economy all on par
So if you cant pay prof engineer, you cant built a house. You know prof engineers are not cheap these day.
@@wawannazar2275 what you save for prof engr you make up for the bars... 🙂 in any case, bear in mind safety always comes a priority
I want have column Rings grape 7 inchee with 20 mm 4 bar n 2 piece 16 mm
Hello mr civil engineering where is the footing of colum???very big mistake....he is not a civil engineer.....
What are byou doing? Do you understand what you do?
sir also made video in pashto please
Sir I want to know about colum size, beam size and depth of footing for two storey house
Add a video for two storey house
👍👍🙏🙏🙏
👍👍👍❤
The reinforcement is ok.. but the brick foundation. I'm scepticle
Footing dept ?
Sloof & tiang coloum nya ukuran berapa ini ?
Hi
Sir, distance b/w two columns 18ft, and column 9*12inch, pl suggest sillbeam, rcc and beam reinforcement details, construction area 30*40 ft (can I send plan sir)
For 18ft distance you could've used 12*12 inches column size
Waleakum aslam
Why do you bend those hooks at 135°
It can bear more load & Stable than 90° bent hooks
Column size
Ok
Who r u addressing???
Vertical !
Fromm the beginning make a video I mean from foundation
Terrado family share
My contractor has give 25feet distance between two pillars. He has used 9x18 pillar size with 8 pieces of 16mm tmt bars. Beam size is given as 9x24 with 6 pieces of 20mm bars. It is a G+2 residential building. Is it ok ?
My contractor has also used 16mm x8 for the pillars. I want to know if it's OK. (3 story building)
No
these are not 20mm!!
Too much usage of steel, which only increases the cost
5/tr
😥😥
Sir can you added subtitle
gulami wali zuban mat
Speak in Hindi
Bakwas band karu eay 3 floor calculation nahy hy