Design of Column for Three Storey Building Practical Video

Поділитися
Вставка
  • Опубліковано 8 вер 2024

КОМЕНТАРІ • 136

  • @qualitybuilders569
    @qualitybuilders569 3 роки тому +39

    These columns can bear 5 stories, The column design is over specified Its is not economical also design should make as per thickness of walls like 8x18 inch or 8x24 inch would be much better.

    • @Deepakyadav-jk5km
      @Deepakyadav-jk5km 3 роки тому +11

      You're right and he is right too, this column can hold 5-6 floor easily in resident building but as he said this one is for commercial building which mean live load is many times higher than the resident's live load so 3 floor in commercial is easily equal to 5 floor in resident

    • @valentinovictor
      @valentinovictor 3 роки тому +5

      Rightly said, too much usage of steel for 3 storey building, even if it's commercial this specification has been exaggerated

    • @valentinovictor
      @valentinovictor 3 роки тому +6

      @@Deepakyadav-jk5km if the span distance between two columns is higher , then it's acceptable or reasonable to add number of steel rods, but looking at the site the columns are closely arranged and the rooms are not that bigger. Not a proper design

    • @Deepakyadav-jk5km
      @Deepakyadav-jk5km 3 роки тому +1

      @@valentinovictor what if they have to put tonns of metal ore in it, all the theories is worthless in commercial everything should be extra

    • @tumusiimejohn1089
      @tumusiimejohn1089 Рік тому +2

      Liked all arguments you guys. Very educative to us beginners. Thanks

  • @rogernbackyard6677
    @rogernbackyard6677 Рік тому

    Thanks for sharing sir and this vedio...new friend from Phillipines

  • @muralikrishna5435
    @muralikrishna5435 3 роки тому +8

    It will be much better if the bottom of plinthbeam atleast 3inches below ground level to avoid seepage of water into basement during heavy rain and the entry of rats through bottom of beam

  • @jayareddy6252
    @jayareddy6252 Рік тому

    It is very useful for common peoples. Jayachandrareddy

  • @somalia5019
    @somalia5019 8 місяців тому

    New subscribed from Somalia

  • @BLNBorey
    @BLNBorey 2 роки тому

    Good job I love Civil Engineer

  • @nasirahmed5091
    @nasirahmed5091 Рік тому

    Thanks for beautiful information

  • @21stcenturyworldsystem46
    @21stcenturyworldsystem46 Рік тому

    Very knowledgeable video. Thanks

  • @uddinhelal5392
    @uddinhelal5392 3 роки тому

    Very good explain.

  • @phyohtetkoko929
    @phyohtetkoko929 2 роки тому

    Thanks For Teaching Sir

  • @askarkhan263
    @askarkhan263 3 роки тому

    Wow that's nice job and good work

  • @Mike-dm2og
    @Mike-dm2og 3 роки тому

    Jazzakallah Khairan brother

  • @muhammedibrahim450
    @muhammedibrahim450 11 місяців тому

    It's good. Keep it up.

  • @meiyalaganc3204
    @meiyalaganc3204 2 роки тому +1

    Could you please share the video of this building current status… completed building video… thanks

  • @sameersinghyadav5645
    @sameersinghyadav5645 2 роки тому

    Nice and informative

  • @waqastv7862
    @waqastv7862 3 роки тому +1

    Sir this plinth beam alignment out not proper work because plinth beam is zigzag?

  • @aamirsingh3351
    @aamirsingh3351 3 роки тому +3

    I'm just a random guy but I can see all the rebars are cut at same height .
    Is this acceptable ?

    • @sanjayhs5301
      @sanjayhs5301 3 роки тому +2

      No... it's not acceptable...

  • @krishnaommi691
    @krishnaommi691 3 роки тому +2

    I am using 9 X 18 column size distance between two columns 20feet .. so which size using beams and bars

  • @KoromaAlhajiSheiku
    @KoromaAlhajiSheiku Місяць тому

    Is this same reinforcement continue to the last floor

  • @AungThein-zh7cj
    @AungThein-zh7cj Рік тому

    Verygood

  • @bickyrajkumar3545
    @bickyrajkumar3545 3 роки тому +2

    3 storey building heavy steel bar therw is no diamond stirup

  • @uniquerahman9887
    @uniquerahman9887 3 роки тому

    Good job

  • @julianamyrthong1263
    @julianamyrthong1263 3 роки тому +1

    Please explain about domestic building

  • @valentinovictor
    @valentinovictor 3 роки тому +2

    Using 20mm rods, that too for 12 numbers, is way too much , not a feasible cost effective design

  • @madhurisurajbharath3634
    @madhurisurajbharath3634 2 роки тому +1

    Sir iron will get rust , after some years. Can we use steel instead of iron for pillars.. .

  • @mickhailrapang7316
    @mickhailrapang7316 8 місяців тому

    What about the iron for the floor where it is tied... Sorry I just learned

  • @abmsiddiqui007
    @abmsiddiqui007 7 місяців тому

    fine

  • @j6pluskusnandar265
    @j6pluskusnandar265 3 роки тому

    Waalaikum Salam warohmatullohi Waabaraqatuu🙏🙏🇮🇩

  • @Fundamental_Gospel
    @Fundamental_Gospel 3 роки тому

    Sir, you are very sincere!👍

  • @krishna_raj9331
    @krishna_raj9331 2 роки тому +3

    Hello sir,
    Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..?
    The column to column distance is 15 feet.
    How many storeys can be built with this much reinforcement..?

  • @halonaoba8827
    @halonaoba8827 3 роки тому +3

    Sir i want to know about septic tank for house best

    • @praveensm223
      @praveensm223 3 роки тому

      ಈಶಾಣ್ಯ ಮೂಲೆ

  • @erkundanyadav
    @erkundanyadav 3 роки тому

    Perfect

  • @mohmmadjeyaurrahman8105
    @mohmmadjeyaurrahman8105 3 роки тому +3

    Assalamo alaikum
    I made a structural design of 3 storey domestic building as per IS code in my design column size is 230*230 with 16mm 4 baar and bindup it with 8 mm ties by calculation it can bear the load so it's right or not please comment
    Thank you

  • @jyot3950
    @jyot3950 3 роки тому +1

    If there is one basement one ground and 4 more stories,total 6 then what should be the column beam structure

  • @SuperCOLDRICE
    @SuperCOLDRICE 3 роки тому +1

    Perfect job

  • @shrayanshjha8109
    @shrayanshjha8109 3 роки тому +7

    I am using 9" X 15" column for 19 feet horizontal span So What can be the distance between two column vertical span for G+2 building

  • @hokughazhimomi2835
    @hokughazhimomi2835 3 роки тому +2

    I want to have 15 feer distance from column to column or( 16 feet center to center of column), using 9"x15" size column.
    1 is it OK?
    2. What size and number of steel bars are advised?

  • @qualitybuilders569
    @qualitybuilders569 3 роки тому +4

    16mm Longitudinal would have been enough

  • @nobertsyriaque6727
    @nobertsyriaque6727 3 роки тому +2

    What is the size of footing and steel reinforcement details.

  • @migustoes5089
    @migustoes5089 Рік тому

    What about if I need Reinforcement columns? The measurements will be the same?

  • @joelrosales6359
    @joelrosales6359 Рік тому

    Notice no construction joints for beams and columns.

  • @riqueldelcopete6504
    @riqueldelcopete6504 3 роки тому

    Hola amigo sebe una estructura muy bien y fuerte como para hacer 5 o 6 alturas 🇪🇸👍💪

  • @sankarmegavath6265
    @sankarmegavath6265 Рік тому

    Sir, between coloum Max allowed length please

  • @sajjadrehmani7439
    @sajjadrehmani7439 11 місяців тому

    sir how distance in 2 coulumn in three story buillding you prefferd. plz reply

  • @kindisaac5008
    @kindisaac5008 Рік тому +1

    I love tutoring I hope I will contact you someday

  • @probathsangma5951
    @probathsangma5951 2 роки тому

    Sir from the starting show

  • @vikasjha6829
    @vikasjha6829 2 роки тому +1

    Sir 1200 sq ft m ghar bnana h mujhe..3 manjil building bnane k liye pillar ka size 10"x10" de skte h with 6 rods of 12 mm.
    Distance between two pillars is 10 feet.. Total 12 pillars h..
    Please mera reply kre ❤💯🙏🏼🙏🏼🙏🏼🙏🏼

  • @engpk7211
    @engpk7211 Рік тому

    Number of bars and column sizes way too beyond required standards depending on floor loadings and number of floors

  • @user-sq7cq6pn1b
    @user-sq7cq6pn1b Рік тому

    Dear, How do I buil G+2 Building using 9"x12" column size

  • @dohdolla1704
    @dohdolla1704 Рік тому

    What is an inch in technology

  • @user-cb5mi3qq8m
    @user-cb5mi3qq8m 2 місяці тому

    Detail grade beam

  • @Kpraveen1407
    @Kpraveen1407 Рік тому

    Latak Beem kitne inch ka hoga our
    Rencforment kya hogi

  • @robertswanson6774
    @robertswanson6774 2 роки тому +1

    Sir what is your distance from one column to the other?

  • @bilalchohan8761
    @bilalchohan8761 3 роки тому

    Sir why the Brickwork foundations nearly plot too much deep where you use third class brick?

  • @engrrahamsher6162
    @engrrahamsher6162 3 роки тому

    Lap zone in column should be the middle portion

  • @simluong1290
    @simluong1290 3 роки тому

    Quá chắc, xây bao nhiêu tầng hả cụ

  • @anishanishkt5284
    @anishanishkt5284 3 роки тому

    Please details of steel in beam

  • @makistar4855
    @makistar4855 2 роки тому +1

    Sir in my house contractor is using 20 columns but in 6 columns span is 18.5 feet, 19 feet. Is column spain is right. Column size is 9×14 and bars used are 16 bars. 16 mm are 4 bars and 12 mm are 2 bars. And plinth beam size is 9×18 can I go for G+2 with this structure

  • @sukumarghosh1195
    @sukumarghosh1195 2 роки тому

    Centre to centre distance between columns not given

  • @elviraandadi1985
    @elviraandadi1985 9 місяців тому

    what is the column size

  • @malakand1656
    @malakand1656 3 місяці тому

    Dy column da pasa beem size ba sa razi

  • @AlamKhan-hg4fn
    @AlamKhan-hg4fn Рік тому

    سٹیل کے ساتھ جو کنکریٹ لگی ہوئی ہے اس کی صفائی بہت زیادہ ضروری ہے

  • @sadhubaba789
    @sadhubaba789 Рік тому

    No dpc work for ground

  • @mahbubalam2584
    @mahbubalam2584 3 роки тому

    Sir it is learning of construction process. So this is not structure or column design learning or thiury.

  • @jotamanroka7226
    @jotamanroka7226 3 роки тому

    Hight of column from plinth beam.pls mention sir,,,🙏🙏🙏🙏

  • @muhammadadil6183
    @muhammadadil6183 2 роки тому

    Beam boht zeyada day deye hain ap nay.... Kam b day saktay thay

  • @AtaurRahman-lw3pp
    @AtaurRahman-lw3pp Рік тому

    Total rod how much per sqft

  • @anwartalha3048
    @anwartalha3048 3 роки тому

    Sir can I make colomn in plinth beam?if not make in foundation for 2 storey house?

  • @Inspireme211
    @Inspireme211 3 роки тому

    What is size of plinth beam

  • @aifiama5881
    @aifiama5881 3 роки тому

    What about the beam

  • @perfectopadillajr3452
    @perfectopadillajr3452 Рік тому +4

    Thumbs rule: Never make decision on how big and how many bars to use for your house/building if you are not a trained structural designer. Buildings are most likely different from each other. Hire a prof structural engineer, be safe and save money.

    • @engpk7211
      @engpk7211 Рік тому

      True. Safety and economy all on par

    • @wawannazar2275
      @wawannazar2275 Рік тому

      So if you cant pay prof engineer, you cant built a house. You know prof engineers are not cheap these day.

    • @mageinteriors3012
      @mageinteriors3012 Рік тому

      @@wawannazar2275 what you save for prof engr you make up for the bars... 🙂 in any case, bear in mind safety always comes a priority

  • @mathskind
    @mathskind 2 роки тому

    I want have column Rings grape 7 inchee with 20 mm 4 bar n 2 piece 16 mm

  • @shahidmunir4917
    @shahidmunir4917 Рік тому

    Hello mr civil engineering where is the footing of colum???very big mistake....he is not a civil engineer.....

  • @truesolution6069
    @truesolution6069 5 місяців тому

    What are byou doing? Do you understand what you do?

  • @hikmatkhan3385
    @hikmatkhan3385 3 роки тому

    sir also made video in pashto please

  • @debasisdas5696
    @debasisdas5696 3 роки тому

    Sir I want to know about colum size, beam size and depth of footing for two storey house

  • @maskepo99
    @maskepo99 Рік тому

    👍👍🙏🙏🙏

  • @julsvlogtv1991
    @julsvlogtv1991 2 роки тому

    👍👍👍❤

  • @alinsorohan
    @alinsorohan Рік тому

    The reinforcement is ok.. but the brick foundation. I'm scepticle

  • @deleted1070
    @deleted1070 3 роки тому

    Footing dept ?

  • @NdyMv24
    @NdyMv24 Рік тому

    Sloof & tiang coloum nya ukuran berapa ini ?

  • @asiffarsifitingkolhapur6820
    @asiffarsifitingkolhapur6820 Рік тому +1

    Hi

  • @rameshak5268
    @rameshak5268 2 роки тому

    Sir, distance b/w two columns 18ft, and column 9*12inch, pl suggest sillbeam, rcc and beam reinforcement details, construction area 30*40 ft (can I send plan sir)

    • @rahulbisht3838
      @rahulbisht3838 Рік тому

      For 18ft distance you could've used 12*12 inches column size

  • @mjshafi5311
    @mjshafi5311 2 роки тому

    Waleakum aslam

  • @baiduibrahim6424
    @baiduibrahim6424 3 роки тому

    Why do you bend those hooks at 135°

    • @kgmanjunatha4849
      @kgmanjunatha4849 2 роки тому +1

      It can bear more load & Stable than 90° bent hooks

  • @harishkumarsharishkumars848
    @harishkumarsharishkumars848 3 роки тому

    Column size

  • @kulijowo8273
    @kulijowo8273 Рік тому

    Ok

  • @Kse1010
    @Kse1010 Рік тому

    Who r u addressing???

  • @sonofman8262
    @sonofman8262 Рік тому

    Vertical !

  • @probathsangma5951
    @probathsangma5951 Рік тому

    Fromm the beginning make a video I mean from foundation

  • @joshuaterrado9654
    @joshuaterrado9654 2 роки тому

    Terrado family share

  • @pavanagarwal9167
    @pavanagarwal9167 2 роки тому

    My contractor has give 25feet distance between two pillars. He has used 9x18 pillar size with 8 pieces of 16mm tmt bars. Beam size is given as 9x24 with 6 pieces of 20mm bars. It is a G+2 residential building. Is it ok ?

    • @justmusz6530
      @justmusz6530 2 роки тому

      My contractor has also used 16mm x8 for the pillars. I want to know if it's OK. (3 story building)

    • @surendersharma3879
      @surendersharma3879 Рік тому

      No

  • @titde1961
    @titde1961 2 роки тому

    these are not 20mm!!

  • @valentinovictor
    @valentinovictor 3 роки тому +3

    Too much usage of steel, which only increases the cost

  • @user-xh3hj8cl8z
    @user-xh3hj8cl8z Рік тому

    5/tr

  • @SabirAli-dm8zj
    @SabirAli-dm8zj 3 роки тому +1

    😥😥

  • @sukasunnah
    @sukasunnah 3 роки тому

    Sir can you added subtitle

  • @Molanan4
    @Molanan4 3 роки тому +1

    gulami wali zuban mat

  • @Sarojkumar-xe2qi
    @Sarojkumar-xe2qi Рік тому

    Speak in Hindi

  • @JaveedKhan-sn6qz
    @JaveedKhan-sn6qz 3 роки тому

    Bakwas band karu eay 3 floor calculation nahy hy