Delta PLC Simulator and Factory IO connection

Поділитися
Вставка
  • Опубліковано 15 тра 2023
  • Everyone I see on youtube is running factory io with a real plc. I show you how to do it with COMMGR simulator WITHOUT a real plc.
    I shared similar subjects in my blog. You can translate it by using the translate widget on the left side.
    erolcum.blogspot.com/2023/05/...
    Programs used in video :
    Download free softwares ISPSoft 3.17 and COMMGR 1.14 from :
    downloadcenter.deltaww.com/en...
    www.ptc.com/en/products/kepwa...
    factoryio.com/download-archive/
    www.hw-group.com/software/her...
    This site can calculate LRC in modbus ascii packet if you want :
    www.metools.info/encoding/ecod...

КОМЕНТАРІ • 21

  • @shabnalp.m4440
    @shabnalp.m4440 Місяць тому

    Thanks for the explanation. In my case it's working only with the internal memory bit. If I use a bit like X0 or X1 it's not working.
    I noticed that "client access" in the tag section changes to read only mode.

    • @mohamadjavadarab6114
      @mohamadjavadarab6114 27 днів тому +1

      In delta PLC simulation, you cant change the value of inputs. because of that you have to use internal Memories instead of inputs. It's different from Siemens simulation

  • @sourabhraghuwanshi8299
    @sourabhraghuwanshi8299 Рік тому +2

    Thanks brother, it is working,

  • @ertugrulbayhan
    @ertugrulbayhan Рік тому +1

    Emeğinize sağlık

    • @erolcum34
      @erolcum34  Рік тому +1

      Sizin gibi ilgili gençlere bu ülkenin ihtiyacı var, rica ederim

    • @ertugrulbayhan
      @ertugrulbayhan Рік тому

      @@erolcum34 hocam inanın ilgili gençlere sizden başka kimse bir harf bile öğretmiyo 4 aydır staj yeri aruyorum 😀😀😀 kimse almıyo

  • @realdraxx2142
    @realdraxx2142 9 місяців тому +1

    In factory io, in the opc server drop-down menu nothing is showing

    • @erolcum34
      @erolcum34  9 місяців тому

      your firewall or antivirus blocks port 10002 may be, I don’t know. You may try to give permission for this port in firewall

  • @shorty52732
    @shorty52732 4 місяці тому

    Inside isp soft when i write a ladder turning an output on, the output doesnt turn on inside factory io nor does it change value from 0 to 1 inside of kepserver. What could i be doing wrong ?

    • @erolcum34
      @erolcum34  4 місяці тому

      please watch the video carefully. Port number, address etc. anything may be the issue

  • @MrMango-if8ye
    @MrMango-if8ye Рік тому

    How do you know what address to put for tags in kepserverex?

    • @erolcum34
      @erolcum34  Рік тому

      please watch carefully. it is shown in commgr settings second 44 of video

  • @vishnuhu9086
    @vishnuhu9086 9 місяців тому

    Why do we have to use the kepler software, is it possible to do it without it?

    • @erolcum34
      @erolcum34  9 місяців тому

      it is a communication bridge between dvp simulator and factory io. so it is required.

    • @vishnuhu9086
      @vishnuhu9086 9 місяців тому

      @@erolcum34 Delta connects to kepler using modbus over ip. so why cant it do the same with factory io?

    • @erolcum34
      @erolcum34  9 місяців тому

      delta uses modbus ascii protocol but factory io does not support this protocol

  • @realdraxx2142
    @realdraxx2142 8 місяців тому

    Where can i find input/output address like 001281

    • @erolcum34
      @erolcum34  8 місяців тому +1

      You need to find it from Delta documents. You can see it here : www.scribd.com/document/382276093/Modbus-Address-Table-Delta-Plc

    • @realdraxx2142
      @realdraxx2142 8 місяців тому

      @@erolcum34 thanks man

  • @teknology111
    @teknology111 5 місяців тому

    WPLSOFT ile de oluyormu