PILE FOUNDATION OF BRIDGE IN DETAIL || PILING || MAIT MACHINE || HYDRAULIC DRILLING RIG|| PILE CAGE

Поділитися
Вставка
  • Опубліковано 10 бер 2021

КОМЕНТАРІ • 22

  • @kennyomega8937
    @kennyomega8937 Рік тому

    Useful video. Thank

  • @ranjeetKumar-tg2sr
    @ranjeetKumar-tg2sr Рік тому

    Thanks sir aap kafi details me btate hai

  • @shankarbirajdar1356
    @shankarbirajdar1356 10 місяців тому

    @13.26min what is name of this procedure (removing cement exposing rebar) ?

  • @TheUnknownvisitor
    @TheUnknownvisitor Рік тому

    Vertical out hai,

  • @satyajitdas9980
    @satyajitdas9980 27 днів тому

    First pouring time charging plate dala nahi, ganda Pani pile k andar gushgaya, a to bahut bara galti hogaya matlab pile bakar hogaya...

  • @akashshelke1475
    @akashshelke1475 Рік тому

    Can we get this drawing copy pdf in discription

  • @lalitlokesh667
    @lalitlokesh667 2 роки тому

    concreteing karte hue charging plate nhi lagayi

    • @lalitlokesh667
      @lalitlokesh667 2 роки тому

      agar concrete hard hota to treime pipe chowk karsakta hai

  • @msvlogs9923
    @msvlogs9923 2 роки тому

    How many pilling for one pillar

    • @ranjeetKumar-tg2sr
      @ranjeetKumar-tg2sr Рік тому

      Depending upon soil quality and load
      Normally 4 , 6, 8, 10 group use

  • @onlyayushonly
    @onlyayushonly Рік тому

    Betonite consumption kitna hota hai for 1200mm dia pile

  • @rohitsinha5991
    @rohitsinha5991 2 роки тому

    Sir thoda ache se samjhao ki cutt of level pile me kya hota hai

    • @civilinformationatsite
      @civilinformationatsite  2 роки тому

      As per IS 2911-1-2
      It is the level where a pile is cut-off to support the pile caps or beams or any other structural components at that level.

    • @LAXMAN12325
      @LAXMAN12325 2 роки тому

      @@civilinformationatsite It is the cut-off for mixed soil, plastic with concrete that comes up above the pile cut-off level,
      But we need pure concrete to be there so that we cut out that mixed concrete where soil particles, plastics & other unacceptable particles are present.
      Ex:- if your depth of pile is 10m(pile cut-off level @10m) then You've to pour concrete up to 11m to 12 m
      That means- 1m to 2m more than that(above cut-off level).
      "You might have one doubt that how unacceptable concrete mixture comes up above the pile cut-off level"
      It is because we placed our Timmy pipe to pour concrete into the pile hole but we'll not place our Timmy pipe exactly to the 10m means not into the touch of hard strata so that when we pour concrete through Timmy pipe then after filling the bottom part, concrete starts coming up around the Timmy pipe.

    • @vverma1987
      @vverma1987 2 роки тому

      @@civilinformationatsite please send your no

  • @justaewaine
    @justaewaine Рік тому

    Bhai mery first of all aap kay logo ki safety bilkul ni dosra aap nay trimie pipe ko boar main dalny kay bad sub kuch hata lia i mean clump wagera .
    Tesra kay aap nay na he ramp bnaya jis say truck waly ko mushkil say bore pay truck lagana para.
    4th kay aap ny koi descending ka function ni rakha agr ni to pani ko bahir phenkny kay liay chota sa pit bna lety hain jis say kay thora yeh hota hy kay pani cassing ki sides main ni ghusta jis say koi pareshani nai peda hoti.
    Or han spacer lazmi use kia karo

  • @deepakkumarpandey6696
    @deepakkumarpandey6696 3 роки тому

    piling