Pile Foundation कैसे डाली जाती है

Поділитися
Вставка
  • Опубліковано 7 сер 2020

КОМЕНТАРІ • 65

  • @CivilEnggQuickSolution
    @CivilEnggQuickSolution  3 роки тому +3

    facebook.com/jatinsaini70/
    Follow on Facebook

  • @skullfire_9
    @skullfire_9 3 роки тому +5

    sir video acchi hai...par agar waha they toh bolna jarur chahiye tha ki reinforcement jaali jo andar daal rahe, saare ko lakwaa maar diya hai...puri ring tedhi.....reinforcement bhi load lene ka kaam karta hai....agar mai uske original position se jaise taise daal k concrete karwaa du...toh wo galat hai...aur aisa koi book ya IS code nai sikhaata...I have already worked as site engineer and know ki thoda bhot galti hoga hi...maine bhi kiya hai...lekin rings itni tedhi aur ring mai cover disc bhi nai ek bhi....aapko tokna chahiye tha....ya ho sakta mere aakho ka dhokha hai...either way it can be but I simply put forth my point

  • @possibleboy5537
    @possibleboy5537 2 роки тому +2

    Very helpful video for all civil engineering students

  • @khanfahad93
    @khanfahad93 2 роки тому +1

    Thanku Sir for sharing such informative video

  • @AjayThakur-ko2sc
    @AjayThakur-ko2sc 3 роки тому +1

    informative video sir

  • @RS-up4si
    @RS-up4si 3 роки тому +4

    very practical video of field🧡🧡🧡

  • @birdslife01
    @birdslife01 3 роки тому +1

    Good work,sir

  • @mebinglapung3405
    @mebinglapung3405 3 роки тому +1

    Clearly explained sir

  • @budhiramsahni3581
    @budhiramsahni3581 2 роки тому +2

    Dear Sir, under bottom bars should be develop length bars L safe size

  • @kennyomega8937
    @kennyomega8937 Рік тому

    Thanks

  • @Deep_2397
    @Deep_2397 3 роки тому

    wao amazing

  • @ritwikgaur1858
    @ritwikgaur1858 3 роки тому +4

    Sir u are doing a great work... Keep it up..... 🙏🙏

  • @RandomVideos-xy5uz
    @RandomVideos-xy5uz 3 роки тому

    Best video 👍👍

  • @iert9120
    @iert9120 2 роки тому

    Nice video sir.....aur video banaiye sir

  • @nawinsingh9467
    @nawinsingh9467 3 роки тому +5

    Sir, kindly make video on pile foundation used in transmission lines in river crossing.

  • @adnan3122
    @adnan3122 3 роки тому +1

    Spacing bar should not require?
    For conecrete cover

  • @nanajeenani7157
    @nanajeenani7157 3 роки тому +1

    Why concrete is not Segregation in water? Please clarify

  • @bvsnagababu7954
    @bvsnagababu7954 8 місяців тому

    sir how much time required to drill the bore of 20 mtrs on a average of dia 1200 and the rate per meter how to fix it

  • @anujj1459
    @anujj1459 3 роки тому +2

    Good video sir 🙏

  • @shababimran
    @shababimran 3 роки тому +1

    Whats is the slump?

  • @poshandas8112
    @poshandas8112 3 роки тому

    Kon sa grade h water kitna mix h is concrete m

  • @ashutosharya6221
    @ashutosharya6221 5 місяців тому

    they haven't provided the leggings of bar at termination level in pile cage, its not the right practice

  • @bhojrajpatle7443
    @bhojrajpatle7443 11 місяців тому +1

    Pile के bottom में cover नही छोड़ते क्या 300 mm का cover रहना चाहिए। आपकी pile cost करने की theory galat hai

  • @civilbabavlogs8778
    @civilbabavlogs8778 3 роки тому +1

    Without safety.......how it is possible ???

  • @er.ankitmishra1682
    @er.ankitmishra1682 2 роки тому

    👍

  • @rajvardhan8605
    @rajvardhan8605 Рік тому

    Without flushing 🙄????

  • @vishalsahu3180
    @vishalsahu3180 2 роки тому

    बेन्टोनाईट कितना use करते है।

  • @Meditation3850
    @Meditation3850 7 місяців тому

    Covering ka use nhi kiya

  • @narentamang54
    @narentamang54 Рік тому

    cover block has not been provided .

  • @ajaysalvi2571
    @ajaysalvi2571 3 роки тому +2

    Cover nahi diyaa hai

  • @AhmadRaza-gy3pn
    @AhmadRaza-gy3pn 3 роки тому

    1200 Dia ki pile hai kya

  • @CivilThinking
    @CivilThinking 3 роки тому +1

    Nice sir.

  • @arjunasoren9610
    @arjunasoren9610 3 роки тому +1

    Pile cage spirals are not fixed on proper way

  • @07ahirprabhu41
    @07ahirprabhu41 3 роки тому +2

    Thank you sir

  • @santoshkakde5928
    @santoshkakde5928 3 роки тому

    1pile ke liye kitna kharcha aata hai

  • @ArifShaikh-ni8mt
    @ArifShaikh-ni8mt 2 роки тому +1

    Wrong method of cage lowering and cage without cover block is ok for you..?

  • @baburana3428
    @baburana3428 2 роки тому

    I need machine

  • @qambaralibhangwarcivilengi5380
    @qambaralibhangwarcivilengi5380 3 роки тому

    What is pile foundation?

    • @SonuYadav-yx1lm
      @SonuYadav-yx1lm 3 роки тому

      Deep foundation used to transfer load of a structure on hard strata.

  • @vishaljaiswal1440
    @vishaljaiswal1440 3 роки тому

    sir jab concrete dalta hai tab impurity mix nahi hota hai kya

    • @GautamKumar-cz2vf
      @GautamKumar-cz2vf 3 роки тому

      Nhi hota hai.... Charge krte hai concrete ko...mtlb freefall me concrete ko girate hai.... To jitna impurities rhta hai upar aa jata hai....

  • @technicalengineer1235
    @technicalengineer1235 3 роки тому

    Sir sabhi ka technical name bhi bataye

  • @syedasif2945
    @syedasif2945 Рік тому

    Siment salari pani ke sath bahar nahi aaega

  • @johnbutler7023
    @johnbutler7023 2 роки тому +1

    Why we don't pump out all the water before concreting ? If the water mixes with concrete will it not affect the water/cement ratio ?

    • @Jayeshsharma15
      @Jayeshsharma15 2 роки тому

      thats what i was thinking. this method will decrease strength of concrete.

    • @omparkashjoshi8459
      @omparkashjoshi8459 2 роки тому +1

      Due to higher water label of water , it's keep coming

    • @er.subhashkumar9653
      @er.subhashkumar9653 Рік тому

      Even after 1 month water will not be emptied

  • @Sunnysingh-zk8ur
    @Sunnysingh-zk8ur 3 роки тому +1

    1st like sir

    • @CivilEnggQuickSolution
      @CivilEnggQuickSolution  3 роки тому +1

      Anil Rajput thank you very much

    • @Sunnysingh-zk8ur
      @Sunnysingh-zk8ur 3 роки тому

      @@CivilEnggQuickSolution ni thnku apko sir boht sikne ko milta ae apse🙏

    • @Sunnysingh-zk8ur
      @Sunnysingh-zk8ur 3 роки тому

      @@CivilEnggQuickSolution sir simpsons formule k bare me batado plssss

  • @mustknow4008
    @mustknow4008 3 роки тому

    Sir jo pipe use kar rahe hai uska dimensions kya hai

  • @ajaysalvi2571
    @ajaysalvi2571 3 роки тому

    Water se clean bhi nahi kiyaa

  • @Satyamje007
    @Satyamje007 Рік тому +2

    1. No cover blocks
    2. Very poor spacing of helical rings
    3. No L in bottom cage
    4. No Proper lap
    Very bad pile work

  • @raviranjansingh28
    @raviranjansingh28 2 роки тому +1

    Mashine bale ka no do

  • @chandanbiswas9097
    @chandanbiswas9097 3 роки тому

    Apka ae pile Cage ki Cover kew nahi apply kiye sir ji ? Pile cap me keya Cover nahi ata he sir ji 😂?

  • @shababimran
    @shababimran 3 роки тому

    Yar aadha adhura video mat bnaya kero..ya to video.mein detail information diya kero ya video mat bnaya kero..apne liner ke bare mein kuch nhi btaya..jo ki isme already dala ja chuka hi