Mini Split Air Conditioner the compressor won’t run

Поділитися
Вставка
  • Опубліковано 26 гру 2024

КОМЕНТАРІ • 154

  • @rottiev264
    @rottiev264 2 роки тому +19

    Been on a few ductless courses, those boards hold around 300vdc after you shut off the power, they always told us it takes about a sec per volt to dissipate, so give it at least 5min before diving in. Good advice for clearing nuisance codes too 👍

    • @jphvac5725
      @jphvac5725 2 роки тому +3

      Or you can discharge the caps just like with microwaves. That many volts dc especially with high amps can not just shock but kill.

  • @tcphvacr9950
    @tcphvacr9950 2 роки тому +12

    Glad you mentioned about the inverter board being dangerous after powering off. The capacitors hold one hell of a charge that’ll hurt you bad.

    • @FlyEaglesFly19111
      @FlyEaglesFly19111 2 роки тому +3

      All the new modulation equipment is that way now. Minisplits are no different. Wait at minimal 10min. Yes 10 min before diving in or that will be one hot potatoe.

    • @primetime758
      @primetime758 2 роки тому +1

      i rememeber when i first started workin with my pops i was a little kid touched a start cap ya ... it was a kicker lmfaoo

  • @DanO181919
    @DanO181919 2 роки тому +2

    Enjoyed the music while you put the puzzle back together. 👍👌

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому +1

      Epidemic sound. I had to buy the subscription so I’m UA-cam legal.

  • @danwittels5542
    @danwittels5542 2 роки тому +1

    Excellent repair video! Goo to see Tippy back in the game! ;-)

  • @joeshearer1247
    @joeshearer1247 2 роки тому +1

    I’m impressed you got a new board that quickly

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому +2

      Air con actually has decent support and is dirt cheap. If your customer registers the equipment it’s a 5 year parts warranty.

  • @mallow399
    @mallow399 2 роки тому +4

    Well Done dave. Been telling my boss this for years you cannot go to any mini split system without a service manual.

  • @IFIXCASTLES
    @IFIXCASTLES 2 роки тому +2

    Nice job there Dave!

  • @FlyEaglesFly19111
    @FlyEaglesFly19111 2 роки тому +3

    Goooowd stuff Brother Dave. Those PCB boards go bad alot. They don't like voltage spikes. Usually lower voltages kill them. Carrier/Panasonic mimisplits are horrible nowadays for them. Stay safe and be well Brother Dave.

    • @OcRefrig
      @OcRefrig 2 роки тому

      Yea, I was asked to look at a samsung 3 ton a while ago not working. Two boards failed. not very old unit. maybe 5-6 years. no way to test compressor to see if it failed also / locked up without new boards.

    • @FlyEaglesFly19111
      @FlyEaglesFly19111 2 роки тому

      @@OcRefrig well you could just ohm out the windings. Even put on a megger. I would have ohm out the power and wire to the indoor. I had a job where electricians did a poor job on their end. Other than that grab holy water and pray for the best! Lol

    • @rottiev264
      @rottiev264 2 роки тому +1

      The Cfan motor also likes to take out those boards. They are sensitive, like a woman 🤣🤣🤣🤣

    • @anthony5530
      @anthony5530 2 роки тому

      @@rottiev264 didn’t carrier have a recall on the od fan harness? I know I had to go back and replace several with fusible links to help protect the board from a fan failure.

    • @rottiev264
      @rottiev264 2 роки тому

      @@anthony5530 I’ve had this happen on a couple different brands of ductless, LG, Fujitsu, Daikin, Gree. Not sure about the recall you speak of but sounds like a good idea 👍

  • @OnePointLander
    @OnePointLander 2 роки тому +1

    Out of all my "good" meters, I still use my 35 dollar UNI-T as well. Slim, accurate and reliable.

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 2 роки тому +1

    Stick that manual in the truck!
    Thanks again for the videos!
    🥃🥃🍺🍺🍺🎳⛳
    Stay safe.
    Retired (werk'n)keyboard super tech. Wear your safety glasses!

  • @Abrokadabro
    @Abrokadabro 2 роки тому

    Good work Super Dave

  • @frostcontrolhayder3463
    @frostcontrolhayder3463 2 роки тому

    on Lg when you have same peoblem the manual says check the power if ok or not ,otherwase call Lg service ,anyway after the warranty ends you should forget call Lg service , nice video.

  • @scottk0623
    @scottk0623 2 роки тому

    I don’t know why but the older I get I ABSOLUTELY hate having to replace boards on mini splits. Various tech support seem it quite often have you replace the condenser fan motor when doing a board. Glad it went smooth for you.

  • @sterlingarcher46
    @sterlingarcher46 2 роки тому

    The board's packaging was hilarious 🤣

  • @frankjackson1918
    @frankjackson1918 2 роки тому +1

    Great work Dave. I wish you would use your ladder lock on that extension ladder. Only takes a few extra minutes to clamp it on .

    • @OcRefrig
      @OcRefrig 2 роки тому +1

      nothing to clamp to.

    • @shifter8207
      @shifter8207 2 роки тому

      Wish that ladder grip thing worked on roofs like those...
      Good ol bungee cord or tool bag strap is the only real good way

  • @Eddy63
    @Eddy63 2 роки тому

    Super Dave brings good things to life ... Good vid thx for sharing ...

  • @fredflintstone8048
    @fredflintstone8048 2 роки тому +2

    Super techs are never afraid or think they're too smart to read a tech manual.

  • @avarageerod
    @avarageerod 11 місяців тому +1

    Great video. Appreciate it. Where did you order the board from?

  • @jrsmyth9761
    @jrsmyth9761 2 роки тому +3

    Disconnect mounted directly on equipment is okay in your area?

  • @throttlebottle5906
    @throttlebottle5906 2 роки тому +1

    it's always good idea to "hipot" test the compressor before calling a control board. it could very well have a current leak to ground, which can kill the board and not show up on simple resistance testing with ohm meter. I'd say the off brand mini-splits are meant to be thrown away when broken.

  • @embeddedgirl
    @embeddedgirl 2 роки тому +2

    electronics engineer here, those switching FETs (black 3 pin devices at the top of the board) don't look too happy. I'm willing to bet that they went open circuit due to extended thermal stress. these FETs drive the compressor btw, which would explain no output from the drive.

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому

      Outstanding thank you

    • @yeliab814
      @yeliab814 2 роки тому

      The compressor three phase vfd switching actually occurs in the integrated power module to the right. The bridge rectifier is to left. Those middle two components are curious. The right one almost looks like two pin not three, maybe diode? Maybe they are a mos switch and schottky for some kind of power factor correcting boost citrcuit? Don’t typically see any to220 devices wherever the integrated vfd power modules are employed. for example look at latest generation genteq ecm motor controller boards. silicon consists of bridge rectifier and an STM integrated “power module” vfd/mcu chip..

    • @embeddedgirl
      @embeddedgirl 2 роки тому

      @@yeliab814 ahh ok makes more sense I had a feeling it might be the module but wasn't sure. I dont deal with high power stuff, I work with FPGA's all day lol. those STM modules look really cool though, I might toy around with some if I get some time.

    • @yeliab814
      @yeliab814 2 роки тому

      @@embeddedgirl FPGA’s thats super cool. Yes the modules are really amazing, although the datasheet scared me off. In theory the modules promise greater reliability through defined circuit paths, inherent FET matching built-in switching deadltime control/protection, etc. Time will tell. . As with the latest new things these days, designing around these seems all about writing the software /logic implementation !

    • @embeddedgirl
      @embeddedgirl 2 роки тому

      @@yeliab814 reliability, yea ok Dave should send them the board to evaluate their claim lol. I'm still willing to bet thermal stress is the cause of its failure,

  • @harryharding2123
    @harryharding2123 2 роки тому +1

    That mini split was straight forward unlike a Fujitsu, ever check out that video on Andy Irons

  • @dalza_uk9424
    @dalza_uk9424 2 роки тому +1

    PCB Board hehehe......top job though :)

  • @soloch69
    @soloch69 2 роки тому

    Love it keep them coming great videos👍🏻

  • @sevagarmoudikian4639
    @sevagarmoudikian4639 2 роки тому

    Dave looks like they have been spraying the sky’s there also

  • @PaulHVAC1
    @PaulHVAC1 2 роки тому

    Love it Dave 👍✌️

  • @ishkabibble-oj1oi
    @ishkabibble-oj1oi 9 місяців тому

    Is there a surge protector on the disconnect ?.

  • @gene-khvacr
    @gene-khvacr 2 роки тому

    Great vid Is that the same place you installed in the kitchen too a while back enjoy watching your vids keep posting keepin it 💯 light and fun

  • @jamierushing8811
    @jamierushing8811 2 роки тому +1

    Hi bro from west Alabama love ya

  • @derricaguilar
    @derricaguilar 3 місяці тому

    What if the board is new but the compressor still won't start? Would you try to repair the compressor or just replace the whole unit?

  • @chrislester3152
    @chrislester3152 Рік тому

    I fixed my mini split throwing protect compressor code and after figuring it out the cause was that I had used a twin piggy back breaker which I have heard causes no harm but it does because I can put mine back on the tandem and get a code and take it off and working without fail so sometimes it may help to check and make sure

  • @thesilentonevictor
    @thesilentonevictor 2 роки тому +1

    Great work nor cal Dave just wanted to ask your work shoe have you had it for a while ?

  • @JohnOgletree-u1q
    @JohnOgletree-u1q Рік тому

    Good video bro... Thx!

  • @dsmillz
    @dsmillz 2 роки тому

    Dave where are you at in the Bay Area? I'm having an issue with my unit and would like to schedule a time for you to come by?

  • @diysolaradventures7894
    @diysolaradventures7894 Рік тому

    What does error code EL OC mean ? Senville 12,000btu Mini Split

  • @Freonleon
    @Freonleon 2 роки тому +1

    Damn hack in moe mini split install from Friday

    • @sjefoekel6058
      @sjefoekel6058 2 роки тому

      Hahaha, this is true! Proof is on U tube

  • @dutch661
    @dutch661 2 роки тому

    Never seen tye wraps used to make a book

  • @bk3606
    @bk3606 2 роки тому

    Hello I have a new 36k 4 zone mini split. It sends all units heat when even only one unit should be calling for it, they will all blow barely warm air. If all are calling heat they all blow hot. No zone control on heat. No error code. What could cause that issue?

  • @timothydelgado4907
    @timothydelgado4907 2 роки тому

    Super mode for the super tech

  • @tanyaradzwatysonmwoyosvi9093
    @tanyaradzwatysonmwoyosvi9093 2 роки тому

    @ Dave did I miss the part where you put heat sink paste when putting the new board

    • @waynecostanza2280
      @waynecostanza2280 2 роки тому

      Sadly I’m sure the way that board was shipped it did not come with any and it probably went back without any. Won’t be long.

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому

      The heat sink comes pre installed on these boards.

    • @waynecostanza2280
      @waynecostanza2280 2 роки тому

      That’s good to hear! Did you remove the old one just for inspection? Good to hear it was covered. Did they want the old board back?

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому

      @@waynecostanza2280 no they didn’t. And yes I took the old one apart

    • @tanyaradzwatysonmwoyosvi9093
      @tanyaradzwatysonmwoyosvi9093 2 роки тому

      Thank you Dave, I love your video they gives me confidence

  • @joshuabest100
    @joshuabest100 2 роки тому

    Did you put fresh thermal paste on the heatsinks

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому

      Heat sink comes installed on new board

    • @joshuabest100
      @joshuabest100 2 роки тому

      @@NorCal-refrigeration oh cool it's just because I saw you remove the old heatsink from the old board but great video

  • @jochemsluis8834
    @jochemsluis8834 2 роки тому

    I have had the outdoor coil sensor measure out fine but had a short which took out the outdoor board. First we replaced the outdoor board which worked for about a month then the sensor shorted the board out again. We replaced the outdoor coil sensor which had arced through the metal housing 👀. I didn't think there was that much voltage to do that but it did and haven't been back.

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому

      Great info

    • @allanbrito13
      @allanbrito13 2 роки тому

      So you ohmed out the sensor and it came out fine then checked it to ground and saw a reading?

    • @jochemsluis8834
      @jochemsluis8834 2 роки тому +1

      @@allanbrito13 No as it was dry at the time but had an outdoor coil sensor fault the second time with comms fault on indoor unit. When talking to tech support they sent outdoor coil sensor and outdoor board under warranty. I noticed the burn hole when replacing it.

  • @michaellow5448
    @michaellow5448 6 місяців тому

    Where are your knee pros??

  • @DWAYNE2ism
    @DWAYNE2ism 2 роки тому

    hey great video. question do you install voltage monitor on these mini split?

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 роки тому +1

    Flares, drains and boards.....3 biggest most common problems with mini splits.

  • @kingofthecrease30
    @kingofthecrease30 2 роки тому +3

    lesson #1...install a mitsubishi mini split 😁

  • @barberlife806
    @barberlife806 Рік тому

    I got a question outdoor ambient temperature sensor where can I get one I’m f1 code on aux mini splitter ac But it works good a tonight

  • @smithsimyon8467
    @smithsimyon8467 7 місяців тому

    We have all type of minisplit pcbs

  • @davejohnsonnola7908
    @davejohnsonnola7908 2 роки тому

    Wait.
    I killed power but there are still bulbs lit?
    Dammit we didn't cover this in shop class 1987!

  • @sjefoekel6058
    @sjefoekel6058 2 роки тому

    Was there warranty? Im suprised that you could get a replacement board.

  • @Yukonjackman1
    @Yukonjackman1 Рік тому

    My heat stopped working, wiggled many wires bundles and it started to work codes lights pointing to doing that.

  • @benkuxhouse787
    @benkuxhouse787 2 роки тому

    How much did that inverter board cost?

  • @billwalton4120
    @billwalton4120 2 роки тому

    What kind of work pants you wear?

  • @RickSegui
    @RickSegui 2 роки тому

    How much is the board?

  • @danvenezio3720
    @danvenezio3720 2 роки тому

    No Heat sink compound in box ?

  • @greg778123
    @greg778123 2 роки тому

    You should put thermal paste back on it
    Definitely would last longer if they run cooler

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому +1

      New board comes with heat sink installed we all good

    • @greg778123
      @greg778123 2 роки тому

      @@NorCal-refrigeration That’s good
      These new units are pretty cool a VFD and 2 dc motor speed controllers threw some microprocessors
      There’s a lot going on

  • @lee-johnson
    @lee-johnson 2 роки тому

    90 day warranty baby!

  • @peterking1134
    @peterking1134 2 роки тому +1

    The compressor runs on DC? I thought that an inverter implied AC.

    • @OcRefrig
      @OcRefrig 2 роки тому

      The word " inverter " means. to invert / opposite. You feed in a/c & Get D/c out. Hense to make a change to opposite.
      inverter can also Feed Dc in & A/c Out. Such as a Car inverter you can buy. Takes Car battery at 12 volts Dc & inverts / changes to the opposite / to A/c.

    • @FlyEaglesFly19111
      @FlyEaglesFly19111 2 роки тому

      Negative. To have an invrrter compressor it runs DC voltage. As the AC voltage will damage the compressor when slowed down.

    • @supersussycat
      @supersussycat 2 роки тому +3

      the compressor does not run on DC, the line voltage (AC) get rectified and smoothed to DC and then chopped to AC again, except now the frequency is not fixed at 50/60Hz, it can change

    • @sjefoekel6058
      @sjefoekel6058 2 роки тому

      @@supersussycat Wrong! Its a brushless DC compressor, and by the way once converted, no turning back to ac just dc pulses coming out.

    • @supersussycat
      @supersussycat 2 роки тому

      @@sjefoekel6058 and "dc pulses" = AC 😂 they even alternate

  • @michaelturner5919
    @michaelturner5919 2 роки тому

    i got a daikin mini split ac only 36,000 btu. for sale, i bought it, used for few wks. now in storage unit. looks n works brand new. open to offers

  • @daleborg9070
    @daleborg9070 2 роки тому

    I did not see any support on the lines between the condenser and the roof penetration.

    • @GOOCHIElicker
      @GOOCHIElicker Рік тому

      The wind keeps them propped up

    • @daleborg9070
      @daleborg9070 Рік тому

      @@GOOCHIElicker ya, the winds coming off the ocean can be pretty strong. It will prop them up

  • @Mrhappy555
    @Mrhappy555 Рік тому

    I enjoy watching mini videos but they way you went up on the roof. Why?

  • @harrydickson4575
    @harrydickson4575 2 роки тому

    👍👍👍

  • @ThePete2432
    @ThePete2432 2 роки тому

    How do u do the ladder without a bungee? Your balls must give you extra stability lol

  • @rocker8692
    @rocker8692 2 роки тому

    I'm in Florida, I imagine people are nicer in Cali,like the girls.Maybe I'm wrong.

  • @WswRefrigeration
    @WswRefrigeration 2 роки тому +1

    If that was a ducted system that board wouldn’t fail

  • @matb2505
    @matb2505 2 роки тому

    Unsubed cuz refrigeration is for the birds rip norcal

  • @shine-cg9uf
    @shine-cg9uf 2 роки тому

    ❄💪🇺🇸👍🔥

  • @OcRefrig
    @OcRefrig 2 роки тому +1

    Good video ! i Wish they had Board tests to actually test the bad board and that way your not just making an educated guess ! / taking a risk of $$$. Board is prob. $300.00 or more.
    That unit was not that old was it ? i thought you just put that in a little bit ago. i think i remember the video.

    • @FlyEaglesFly19111
      @FlyEaglesFly19111 2 роки тому +1

      You can test the board. As most manufacturers put them in upside down. You can test the pins on thw back side. All you need to know is each sensors ohm values. But remember these units are disposable per design. Parts are only kept for 5yrs now that it.

    • @NorCal-refrigeration
      @NorCal-refrigeration  2 роки тому +1

      @@FlyEaglesFly19111 correct 20,000 run time hours rated. 3.5 years if 24 /7.

    • @OcRefrig
      @OcRefrig 2 роки тому

      @@NorCal-refrigeration good to know. 20,000 Rth