HOW TO TEST DAIKIN EEV COIL (5 Cables).

Поділитися
Вставка
  • Опубліковано 8 лип 2023
  • I hope this video helps!

КОМЕНТАРІ • 33

  • @yrwyreazureAjuhtrea7
    @yrwyreazureAjuhtrea7 21 день тому

    These videos are godsend for a tech who’s new to troubleshooting this type of equipment, thank you.

  • @user-gk2ck4pr4g
    @user-gk2ck4pr4g Місяць тому +2

    I see. Thank you.
    Just recently, the EEV coil did not work and the copper tube was frozen.
    Unfortunately, it was Daikin.

  • @musakavalci9470
    @musakavalci9470 29 днів тому

    Great stuff as always. Thanks 👍🏼

  • @jonathonwilliams6722
    @jonathonwilliams6722 Рік тому +4

    Love this sort of content. Gonna share with the lads at work to help them get a better understanding.
    Any chance of future vids of similar nature for other components? Your explanations are a lot better than fault finding from a book!

    • @maracservices
      @maracservices  Рік тому +1

      Thanks mate. Yeah that’s the plan, I’ve made a playlist called Daikin training where I plan to do a video for each component in an air conditioner. I’m no expert, I’m just making videos that I wish I had when I was learning. There will definitely be more videos of this nature. Cheers

  • @robalexander7348
    @robalexander7348 Рік тому +1

    Thanks Mitch, that will be helpful to the new A/C tech guys learning out in the field 👍

  • @vrvlearn8622
    @vrvlearn8622 19 годин тому

    Thank you very much ❤

  • @user-yl9zp8zs4e
    @user-yl9zp8zs4e 11 днів тому

    Very good tnx info

  • @terryh8421
    @terryh8421 23 дні тому

    Thank you, useful info.

  • @ricardofernandes1571
    @ricardofernandes1571 Рік тому +2

    Always great content.

  • @lasim2635
    @lasim2635 5 місяців тому

    Thank you Mitch!

  • @denimdimi
    @denimdimi 2 місяці тому +1

    So I had a daikin 4MXM80 multisplit. After a month 1 room didnt work (valve didnt open). Placed a new motherboard, which blew up a month after installing. Daikin didnt want to send new motherboard under warranty. We decided to buy a new outdoor unit. (4000 euro). And after a month the new one had the same problem, just different room. Now all the sudden Daikin admid that it is a common problem on the MXM series, due to "too low voltage going to the magnets". They will send a new motherboard. Not sure if that is the problem, or if the pins just get stuck. Just FYI so you know :)

  • @agiusproductions5092
    @agiusproductions5092 6 місяців тому +1

    My go to guy for all ac your the best bro

  • @mtz5582
    @mtz5582 3 місяці тому

    I've subscribed as well as I have faith in you.

  • @ameenmakramey1274
    @ameenmakramey1274 7 місяців тому

    Professor, if you could please explain to us a video about the closed electric expansion valve, which carries the model EX7-121 from the working company Amrison, the method of connecting it to the driver, its maintenance, and its problems. I thank you for your cooperation. We greatly appreciate it.

  • @alexibonnet2634
    @alexibonnet2634 8 місяців тому

    This was excellent content without the service facts manual you can use this as a rule of thumb

  • @MitchellSmyth-r8f
    @MitchellSmyth-r8f 18 днів тому

    Hey mate, Do you know resistances & voltage outputs required on a Reversing Valve solenoid coil on a Daikin Ducted 14kw

  • @alexibonnet2634
    @alexibonnet2634 8 місяців тому

    Can you put a video using the EEV tester magnet
    DAIKIN part # 99S0038

  • @declankearney9353
    @declankearney9353 17 днів тому +1

    Hi Mitch have you ever tried getting boards repaired I have always thought it crazy that we have to replace a complete board when I assume all they need is a component ie processor or something. I have tried but had no luck.

    • @maracservices
      @maracservices  17 днів тому

      @@declankearney9353 I’ve taken a board out that was no longer available and taken it to a repairer who did actually repair it but after it was reinstalled, a different fault came up.
      I personally think it’s too risky trying to repair because a component failure can take out another component and you won’t know until you turn it on. Also if it’s a Daikin processor that’s faulty, the repairer won’t carry those parts unfortunately. I just think manufacturers need to make more durable boards but I do know what you mean.

  • @mtz5582
    @mtz5582 3 місяці тому

    So what are the rest of rhe wires for!!

  • @mikaelahyakuya3485
    @mikaelahyakuya3485 Рік тому +1

    Just wonder, have you seen any rust problem on the EEV motor part (the whole black thing)

    • @maracservices
      @maracservices  Рік тому

      Can’t say I’ve ever seen rust issues with them mate. Have you? I’m curious!

    • @mikaelahyakuya3485
      @mikaelahyakuya3485 Рік тому

      @@maracservices (I'm homeoner myself, so I may not have a lot of information about this) However, I did see them in the R22 system (2012) and the new R32 system (2-3 years ago) and plus the outdoor board issues.
      there is a video link here: watch?v=Zk4Ku284cPU
      timestamp: 5:01 is the capacitor that failed in the inverter board (compressor cannot run/cutoff at high speed/ramping up)
      10:40 is the rusting EEV
      And there are lots of video showing how to change the capacitor on the inverter board by technician and homeowner, that speak the number of how many of them failed.

  • @Jim-yk9zw
    @Jim-yk9zw 10 місяців тому +1

    Do you see these things failing much mate?

    • @maracservices
      @maracservices  10 місяців тому +1

      Very very rare in my opinion. But I always check them when I see a faulty board for piece of mind

    • @Jim-yk9zw
      @Jim-yk9zw 10 місяців тому

      @@maracservices Good to know. Thanks for the reply Mitch.

  • @rosamondlucas8658
    @rosamondlucas8658 11 місяців тому

    Promo sm

  • @mtz5582
    @mtz5582 3 місяці тому

    Please watch Craig at Ac service tech...I have high hopes you can do better like him for our side of things ..a smile and well tailored contents will take you there or else....

  • @lukskywalker834
    @lukskywalker834 5 місяців тому

    What about Daikin PQM 10175 6 cabels, similar values?