Good point. Someone who doesn't know any better would assume based off this video that it's also mounted on the outside. In reality, it's on the side we can't see.
It can be networked or not, there is no difference in the functioning of the system. The system described in this video is a networked EntraPass system.
Hello! I have one question about connecting REX button to KT-300. Button should me NC or NO? an illustration in the installation manual suggests normally closed, but in other documents, I have seen it could be normally opened. What is it? or it is configurable? Regards Jaime
On most systems it's N/O. (Close the circuit to open the door) Just test it with a spare wire from negative ground to the push button (REX) terminal. If it activates the relay as soon as you touch it it's N/O and if it activates as soon as you remove it then it's N/C. Hope this helps.
@@Kit_Bear Many thanks!!! Customer has another controllers KT-300 in his building. All existing doors are opened when the exit button is released, therefore all of them are N/C. I will configure the new doors the same way.
It really depends on your equipment. If you are using a KT-400 or a KT-1, you can if using ioProx or ioSmart readers. Please contact technical support if you require any additional information
Working on these doors for the first time. Thank you!
Sorry to be so offtopic but does any of you know a trick to get back into an Instagram account??
I stupidly lost my login password. I would appreciate any tips you can give me
@Baker Patrick Instablaster ;)
Nice explanation of Access control system
.
A mostly overlooked component of all access control systems is the DOOR CLOSER
Nice detailed
Very good explanation
You should fully explain that a Request to Exit is mounted on the secure side (inside) of the door. Otherwise good video.
Good point. Someone who doesn't know any better would assume based off this video that it's also mounted on the outside. In reality, it's on the side we can't see.
The software is the hardest part
Not if you use verkada. That’s the easiest access control software there is
Hello, I have several KT-400PCBs whose heartbeat lights cannot be started, while DC, AC and network can be started. May I ask what is the problem?
Thanks for the useful informations
Basics of Access control is a Standalone System not a Networked system but I liked the explanation. Well done.
It can be networked or not, there is no difference in the functioning of the system. The system described in this video is a networked EntraPass system.
nice its very good
Hello!
I have one question about connecting REX button to KT-300. Button should me NC or NO? an illustration in the installation manual suggests normally closed, but in other documents, I have seen it could be normally opened.
What is it? or it is configurable?
Regards
Jaime
On most systems it's N/O. (Close the circuit to open the door)
Just test it with a spare wire from negative ground to the push button (REX) terminal. If it activates the relay as soon as you touch it it's N/O and if it activates as soon as you remove it then it's N/C.
Hope this helps.
@@Kit_Bear Many thanks!!! Customer has another controllers KT-300 in his building. All existing doors are opened when the exit button is released, therefore all of them are N/C. I will configure the new doors the same way.
Nice Breakdown there. Good Stuff!
No electricity also can use or not
As long as you have a backup battery connected to the controller, it can work during a power blackout. The duration will depend on the usage.
what is height of t .rex sensor and connection mercury MR 51E
I'm afraid we do not have that information at Kantech. Contact the manufacturer of the product for installation recommendations.
Were is the access controller positioned
It could be positioned as far as 1000 feet away. Only the installer can answer that question
Usually in a server room, a telecom room, a closet, above a door (secured side) or any other secured location.
Can I install 2 card readers on both sides of the same door
It really depends on your equipment. If you are using a KT-400 or a KT-1, you can if using ioProx or ioSmart readers. Please contact technical support if you require any additional information
on gallagher, yes u can. just need to program and assign to the door
thanks
Access control λέγεται