How To Set Up an Access Control System: Complete Step-By-Step Guide for Beginners

Поділитися
Вставка
  • Опубліковано 6 жов 2024

КОМЕНТАРІ • 168

  • @fredandrade4676
    @fredandrade4676 4 роки тому +18

    For those experts........this is tutorial for beginners like me, and I appreciate it; if you are an expert instead of coming here to criticize make your own video and teach your skills.

  • @magicmedia7950
    @magicmedia7950 Рік тому +3

    Zkteco company should hire you to make training videos for them. Your tutorial are so easy to understand as compared to what the company tutorials offer

  • @JesusGaytan-sd5cf
    @JesusGaytan-sd5cf Рік тому +3

    The is one of the best training & instruction videos I've ever watched for any subject! Thank you so much. You make the complex easy.....

  • @firstpointcomms1089
    @firstpointcomms1089 2 роки тому +7

    Excellent videos, and I’ve only just started. You teach it like we are in the same room. Thanks in advance 👏

  • @nanagyambibi7426
    @nanagyambibi7426 2 роки тому +4

    Im an aspiring security systems project manager. This is extremely helpful. SUBSCRIBED!

  • @thedogisaneldritchgod491
    @thedogisaneldritchgod491 2 роки тому +2

    I work for a security company and honestly am bored of installing our security panels. Next steps to go is CCTV and Access control. It definitely doesn't look toooooo bad but I'm sure it's probably harder than CCTV since this involves fishing the door frame. Decisions decisions. Thanks for the intro to access control!

  • @brianmoreira7578
    @brianmoreira7578 4 роки тому +7

    GREAT VID. Thanks for the tutorial. Well presented, no fluff, solid and clear delivery.

  • @KenTheWizz
    @KenTheWizz Рік тому +2

    Great video. Thanks for the beginner-friendly tutorials

  • @sillahrakiro
    @sillahrakiro Рік тому +1

    That was quite insightful , I have so much from the video.

  • @RushiPatel-s2f
    @RushiPatel-s2f 16 днів тому

    Hi sir , you explain so nicely
    Thanks for sharing a good video

  • @gbengakayode7417
    @gbengakayode7417 Рік тому

    This Video is not only informative but it is literally taken one by the hand to build an access Door control even as a beginner. Please do you have a Video on ZKTeco F22 Access Control Installation guide?

  • @irshadkm9202
    @irshadkm9202 3 роки тому +2

    The best ACS video I ever watched ✌️

  • @lauraaconceptslk
    @lauraaconceptslk 2 роки тому +1

    great one dude you're worth a subscription. keep your work coming.

  • @royochola
    @royochola Рік тому

    I will always subscribe to your channels....
    Your tutorials really gives me the information that I really need.

    • @NellysSecurity
      @NellysSecurity  Рік тому

      Glad you find them helpful! Let us know if you ever have any questions.

  • @litoneveres3464
    @litoneveres3464 4 місяці тому

    This is an awesome video and the presenter is awesome too, great info

  • @carlobaltazarcanda6159
    @carlobaltazarcanda6159 4 роки тому +2

    Thank you so much for this video. It was very comprehensive. Please continue to create more videos like this. :)

  • @kevino359
    @kevino359 2 роки тому +2

    Thanks for the video. Great information

  • @ipakasivincent6453
    @ipakasivincent6453 2 роки тому +1

    Thanks for this Nelly.

  • @MHA23
    @MHA23 3 роки тому +2

    Dude , such a powerful video . Good work

  • @RocketRossUK
    @RocketRossUK 2 роки тому +1

    amazing video, very clear

  • @tonibasho
    @tonibasho 4 роки тому +2

    Great video presentation and great trainer.

  • @lanreodewale3559
    @lanreodewale3559 Рік тому +1

    Thanks man!

  • @enifomephilip7945
    @enifomephilip7945 10 місяців тому

    Great lesson

  • @AloysiusChowBass
    @AloysiusChowBass 2 роки тому

    Thank you for this video! Now I wonder how access system can work with security cameras.

  • @kumanderkapitan
    @kumanderkapitan 3 роки тому +1

    Good sharing

  • @randolphparham5513
    @randolphparham5513 4 роки тому +1

    Great video!I need some guidance regarding which type to use

    • @NellysSecurity
      @NellysSecurity  4 роки тому +1

      Looks like you reached out to us via our website! We can discuss in details there.

  • @arnobkhanmunna8436
    @arnobkhanmunna8436 4 роки тому +1

    Wow great Video 😍😍 thank you so much boss

  • @jamesmeader2261
    @jamesmeader2261 3 роки тому +1

    Great video thanks

  • @AnjaniShukla-yc9vs
    @AnjaniShukla-yc9vs 4 місяці тому

    Great video I face interview now

  • @BlackAsOne1
    @BlackAsOne1 4 роки тому

    Thank you...I Do This For a Living and I Just was Looking for a System for my Home and I Found One.

    • @NellysSecurity
      @NellysSecurity  4 роки тому +1

      Feel free to reach out to us if you have any questions at all!

    • @AB-mf8le
      @AB-mf8le 4 роки тому

      How is it working in Electronic Security?

    • @BlackAsOne1
      @BlackAsOne1 4 роки тому +1

      @@AB-mf8le Great... Always Thinking and A sense of Accomplishment at the end of every Job! #ProudInstaller

    • @AB-mf8le
      @AB-mf8le 4 роки тому +1

      @@BlackAsOne1 that's good to hear man I'm just starting out. Thanks for your reply

    • @BlackAsOne1
      @BlackAsOne1 4 роки тому

      @@AB-mf8le Enjoy Your Journey And No Problem..

  • @boneymaunduslim3838
    @boneymaunduslim3838 2 роки тому +1

    GREAT VID

  • @irvenconde1089
    @irvenconde1089 Рік тому

    Great content have you ever bumped into a 3 door brivo system I am currently working on one and tbh I am still salty over a last experience I had

    • @NellysSecurity
      @NellysSecurity  Рік тому

      We do not carry that brand! We'd love to talk to you about the products we carry. Our customer service is top notch, so we'll take good care of you.

  • @jamessatuito9488
    @jamessatuito9488 Рік тому

    Great video for beginners like me! I just want to ask if there's a power outage or the power supply is disconnected, how this device would react?

    • @NellysSecurity
      @NellysSecurity  Рік тому +1

      If there's a power outage, all readers would stop working and the locks would either lock or unlock depending if you have it set up as a fail safe lock (will unlock during an outage) or fail secure (would lock during an outage). That said, we recommend a UPS or backup battery.

  • @brendanrx7
    @brendanrx7 3 роки тому +2

    Good to see what the ZKTeco commissioning/user interface looks like. I hear / come across the name a bit.
    Do they incorporate intrusion detection into any of their systems?

  • @gurt.yuri3378
    @gurt.yuri3378 7 місяців тому

    Is there a multidoor video? If you have multiple controllers do you have to program each key to each controller? How would you setup dual card readers for each door?

  • @zombietwenty
    @zombietwenty 4 роки тому

    Nice video. To the point and easy to navigate.

  • @shamms2020
    @shamms2020 3 роки тому +1

    Excellent 👌👍👍

  • @gerardodepedro5420
    @gerardodepedro5420 3 роки тому +1

    Just a query.....is magnetic sensor as the 4th device to detect if the door is slightly ajar or left slightly open?

  • @keeslerslighthouse3503
    @keeslerslighthouse3503 3 роки тому +1

    Excellent tutorial!! Is it possible to incorporate this system with a barcode scanner? Our customers already have ID cards with barcodes on them. Don't want to issue a separate card...

  • @cormcdud1
    @cormcdud1 3 роки тому +1

    Nice, informative video, Tyler! Would this same 1-door system work with one gate operator in the same manner?

    • @NellysSecurity
      @NellysSecurity  3 роки тому

      It will depend on the Gate Operator. Feel free to reach out to our support team.

  • @tylerthegamerofficial
    @tylerthegamerofficial 2 роки тому

    Thanks. If a door hasn't got an electric handle and instead has a normal door handle with a lock, if I unlock the door with a key, will the card reader automatically unlock as if an ID card has been swiped or will it stay locked.

  • @hummer799
    @hummer799 Рік тому +1

    Great

  • @Mack_Dingo
    @Mack_Dingo 10 місяців тому

    Secure em with electric tape. Very professional!

    • @NellysSecurity
      @NellysSecurity  10 місяців тому

      Demonstration purposes only!! We set up systems and tear them down all the time. These aren't meant for permanence.

  • @jorgesandoval6272
    @jorgesandoval6272 Рік тому

    can you please do videos on galaxy access control system , how configure main board , I like watching and learn from. your videos

    • @NellysSecurity
      @NellysSecurity  Рік тому

      We do not currently provide Galaxy systems. If you think it's worth looking into, send us an email at customerservice@nellyssecurity.com!

  • @godisgoodallthetime127
    @godisgoodallthetime127 2 роки тому

    It’s very helpful video but I didn’t see how you wired push to exit also if you show us motion sensor and door lock wiring if we terminate on the same panel

  • @jimleoni5557
    @jimleoni5557 7 місяців тому

    Will the ZKTeco controllers work with existing Honeywell OP10HONS omniprox readers? I'm trying to do a retrofit. Thanks, great video.

  • @sanjha76
    @sanjha76 4 роки тому +1

    Gr8 tutorial....

  • @T_FOR_TOP
    @T_FOR_TOP Рік тому

    T FOR TOP LEARN FROM THIS CHANNEL

  • @tobymiller1252
    @tobymiller1252 2 роки тому

    Great video and through explanations. Only question is does this system have to be installed using internet or can it be set up and operated in a 100% internet free environment?

  • @wisecuritechlowcurrencysys6642

    you can learn TPLINK access controller system, as TPLINK has cctv, net cable, ip broadcst system

  • @angelkarbohal4273
    @angelkarbohal4273 Рік тому +1

    What is the amount of doors that you can add with this system? can you do 5 doors? or if not what is the model that you need to ? Also you mentioned to check with the city and FD for permits?

    • @angelkarbohal4273
      @angelkarbohal4273 Рік тому +1

      BTW This was a great video!

    • @NellysSecurity
      @NellysSecurity  Рік тому +1

      On the Atlas series you can have a max of 21 panels or 84 doors whichever comes first.
      Yes, most state/local laws require permits and a walk through with a local fire marshal. I would check to see what your city requirements are just to be safe.

    • @angelkarbohal4273
      @angelkarbohal4273 Рік тому

      @@NellysSecurity the one on the video only does 1 door correct? So if I need to do 3 doors I will need to purchase 3 panels. Got it! Do you have a link to yours and the one that does 84 doors.
      Thank you!

    • @NellysSecurity
      @NellysSecurity  Рік тому

      Yes a single door controller is for a 1 door solution.
      If youre needing to control 3 doors, then id advise going with the atlas 400 -> www.nellyssecurity.com/zkteco-atlas400-4-door-kit-complete-four-door-access-control-kit-capable-of-using-weigand-and-osdp-readers-supports-poe-power-and-wifi.html
      If you need more than 4 doors for example, you can stack these panels to get to the 84 total doors. 21 x4door controllers = 84 total doors.

  • @yousufismail3983
    @yousufismail3983 4 роки тому

    Hi Great Work!
    Just wondering
    1. I notice there was no Door Contact - Why is that?
    2. The panel doesn't have an emergenc supply pack, how do you combat a brown out?
    Thank you

  • @mgrant670
    @mgrant670 3 місяці тому

    I read that the Data cable pair for the card reader needs to be shielded and twisted. If I used regular 18/2 unshielded, will I have issues?

  • @joellopeznavarro4973
    @joellopeznavarro4973 3 місяці тому

    The card reader is water proof?

  • @leonsantos3168
    @leonsantos3168 Рік тому

    Is the ZTeco controller applicable to hotel application with multiple doors?

  • @joelh577
    @joelh577 3 роки тому +1

    Do you think the backgroud music too loud?

  • @mohideenyasir9353
    @mohideenyasir9353 3 роки тому +1

    nice

  • @TiannaSmith-nf2mc
    @TiannaSmith-nf2mc 3 місяці тому

    Does this installation fail locked or open? If it fails locked, how do you get it back opened offline?

  • @DBlock59V
    @DBlock59V 2 роки тому

    Can add another controller at another building and another network to be used at the same web access so that I can have access to 2 completely separated locations?

    • @NellysSecurity
      @NellysSecurity  2 роки тому

      The controllers can be in different buildings, but they must be on the same network in order to communicate with eachother.

  • @vishallhelm
    @vishallhelm 3 роки тому +1

    Quick question: On the box it says 22/2 and 22/4.
    In the video it says 18/2 and 22/6.
    So which one do I need?
    Thanks

    • @NellysSecurity
      @NellysSecurity  3 роки тому

      You can use any one of them depending on your application. 18 gauge is a better cable.

  • @marcucorina9390
    @marcucorina9390 2 роки тому

    Can you please help me to change the name in the control Acces on this program! Are you something similar in a hotel

  • @christophernavarro6202
    @christophernavarro6202 Рік тому

    For the exit button you say the NC terminates on ground but the diagram shows NO on ground…

  • @mbagle
    @mbagle 3 роки тому

    I would advocate dolphins connection vs wire nuts.

  • @mushtaqjouyia1394
    @mushtaqjouyia1394 5 років тому

    Very nice sir good job 2 comment love from pakistan

  • @samsword3210
    @samsword3210 2 роки тому

    do we have to connect the Electric lock from a separate source such as 220v Ac from a power socket ?

    • @NellysSecurity
      @NellysSecurity  2 роки тому

      It would depend on what power source your lock supports. Typically its 12vDC.

  • @eddiekarie808
    @eddiekarie808 4 роки тому

    Can I have a walk through on everything about access control and your products?

    • @NellysSecurity
      @NellysSecurity  4 роки тому

      You can contact our sales and we can give you a run down on the products. 855-340-9999

  • @danielgrass101
    @danielgrass101 3 роки тому

    Do you have a low voltage license? If so what steps need to be taken in order to obtain that?

    • @NellysSecurity
      @NellysSecurity  3 роки тому

      We do not, this video is strictly for demo purposes. I would contact your local Fire Marshal or a quick internet search for your city/state on that!

  • @gerardodepedro5420
    @gerardodepedro5420 3 роки тому

    How much is one set of the system applicable for one door? Just asking?

    • @NellysSecurity
      @NellysSecurity  3 роки тому

      For sales inquiries, please reach out to our sales team - customerservice@nellyssecurity.com / 855-340-9999

  • @YrHarlow
    @YrHarlow 2 роки тому

    question why did the diagram not macth the nc wiring specified

  • @ISAIDIT411
    @ISAIDIT411 Рік тому

    Are you available and do you offer training

    • @NellysSecurity
      @NellysSecurity  Рік тому

      We do not offer training unfortuantely. There are courses on IPVM.com as well as ZKteco has a C3 Pro certification course you can take.

  • @jdblack7355
    @jdblack7355 2 роки тому

    Will this system work on any door?

    • @NellysSecurity
      @NellysSecurity  2 роки тому

      If you can fit a mag lock or an electric strike on it, then yes!

  • @michaelfauci8148
    @michaelfauci8148 6 місяців тому

    What happens if the system lost power?

  • @securiteelectroniquereseau4103

    bonjour et merci pour la formation est ce possible de pouvoir personnaliser l'interface ivs tout en lui ajoutant un logo d'entreprise ainsi que quelques informations ???

  • @masonm3916
    @masonm3916 4 роки тому

    Can you see which users have used the door in a time period?

    • @NellysSecurity
      @NellysSecurity  4 роки тому

      Each user gets logged once they use their card or pin. You can review the events on live monitor or run the report after the fact.

  • @pendazache8516
    @pendazache8516 Рік тому

    Thanks for that . please bro can I have the support from your ( documents about 2 dors)

  • @jschrock999
    @jschrock999 2 роки тому

    why no shielded wire?

  • @TheJuraev
    @TheJuraev 3 роки тому

    What about 10 doors ?
    sensors and keypads instead of reader ?

    • @NellysSecurity
      @NellysSecurity  3 роки тому

      You can accomplish that with the Atlas series. You will just need to add secondary panels.

  • @sappraku
    @sappraku 3 роки тому

    How do I connect two access controls to one magnetic door lock ?

    • @NellysSecurity
      @NellysSecurity  3 роки тому +1

      Hello, reach out to our support team -> customerservice@nellyssecurity.com / 855-340-9999

  • @PARVEZKHAN-gu6zg
    @PARVEZKHAN-gu6zg 2 роки тому

    How I can connect if I have a sensor based exit button.

    • @NellysSecurity
      @NellysSecurity  2 роки тому

      Hello Parvez, if you got the Access Panel from us, try reaching out to our tech support and we can provide the proper wiring diagram for you - customerservice@nellyssecurity.com / 855-340-9999

  • @owaisazam5333
    @owaisazam5333 5 років тому

    good work sir
    Keep it up
    And first comment 😎

  • @Unknown-kr6gz
    @Unknown-kr6gz 2 роки тому

    Where can I buy ?

    • @NellysSecurity
      @NellysSecurity  2 роки тому

      You can find our ZK teco panels here -> www.nellyssecurity.com/access-control/controller-boards/zkteco.html

  • @stevepol613
    @stevepol613 2 роки тому

    if i want a keypad instaed ok keyreader is that possible?

  • @maxthepiguy3658
    @maxthepiguy3658 Рік тому

    Is their any type of certification program for access control installers? I want to be able to troubleshoot the physical components of the system. I am very familiar with the software and what I can and cannot do. But when those do not work, I get stuck.
    At one of my jobs, the speedy gate is tied to the fire alarm and when we did a few drills, the last drill where the alarm was pulled back on and back off suddenly, the gate locked open. We tried everything from the software and from the device it appears to still be receiving the emergency signal. We reset the controller, badge reader, and activate gate. We power cycled it, reset it manually, and it is doing the same. Only one of the three gates. We don’t know why.
    Other doors are just unlocking on their own and the software keeps showing error on the unit. The error shows when it works and doesn’t.
    Is their a certification for troubleshoooting these types of issues or for an alarm installer?

    • @NellysSecurity
      @NellysSecurity  Рік тому

      Zkteco does offer webinars from time to time. Also they have US based tech support so they can always assist you.

    • @royochola
      @royochola Рік тому

      ​@@NellysSecurity do you have a tecnical based support in Kenya ? I want to always grow with you?

  • @brianmoreira7578
    @brianmoreira7578 4 роки тому

    Real quick....is this the guy from the comedy stand up routine??

  • @accountant-capitalinstallg2163
    @accountant-capitalinstallg2163 2 роки тому

    great video but where can i find the ip address??

    • @NellysSecurity
      @NellysSecurity  2 роки тому

      You can find the IP address using this scanner tool -> www.nellyssecurity.com/media/software/zkteco/DeviceSettingTool.exe

    • @accountant-capitalinstallg2163
      @accountant-capitalinstallg2163 2 роки тому

      @@NellysSecurity i did it i just started doing installation but i never saw a key scan before but today i successfully instal 6 key scan in a hotel and it was pretty easy although its my first time

  • @nidhisharma6075
    @nidhisharma6075 3 роки тому

    Normal call is registerd by acess control likhata ha gab ma kisi ko call karti hu

  • @katiepaine
    @katiepaine 3 роки тому

    this is technically a cat video ^o^

  • @dynoesaur
    @dynoesaur 4 роки тому

    Are all systems the same connections

    • @NellysSecurity
      @NellysSecurity  4 роки тому

      Thanks for the question. Could you elaborate a little more so I can be sure to answer it to the best of my ability.

    • @dynoesaur
      @dynoesaur 4 роки тому +1

      @@NellysSecurity I need tech support

    • @NellysSecurity
      @NellysSecurity  4 роки тому

      @@dynoesaur Give us a shout!

    • @dynoesaur
      @dynoesaur 4 роки тому +1

      @@NellysSecurity big shout outs to Nellys security big ups👍👍

  • @NewVisionLCS
    @NewVisionLCS 5 років тому +1

    I would prefer hardware like this with an electric strike plate for residential installs, instead of the cheap plastic z wave locks!

    • @NellysSecurity
      @NellysSecurity  5 років тому

      I think residential access control will continue to become more popular

    • @NewVisionLCS
      @NewVisionLCS 5 років тому

      @@NellysSecurity me too. I just don't like that a lot of the z wave lock stuff is plastic.

  • @neilmedina1637
    @neilmedina1637 Рік тому

    I actually will not recommend doing it this way. You don't want your request to exit button to release at your panel. Your panel is an electronic component and your request to exit button is relying on it to release. I've seen these panel relays lock before and is never recommended to be release from the panel. It should cut power directly from the Mag lock. He should have added a PIR motion sensor to release at the panel and the button as a direct secondary option (mandatory in most states). Although he has good intentions I would never recommend a beginner to do it this way. He should've recommend an electric strike. Mag locks are risky by state and local county codes.

    • @royochola
      @royochola Рік тому

      Kindly organise for us one tutorial with comprehensive demonstration with easy steps so that we can learn more of these... I'm from kenya

  • @jasimsulthan5208
    @jasimsulthan5208 2 роки тому +1

    Very fast ..

  • @saadhamid4911
    @saadhamid4911 2 роки тому

    where did you live

  • @Sotter-Joy3
    @Sotter-Joy3 Місяць тому

    Hallo

  • @tylervail9532
    @tylervail9532 4 роки тому

    12 minutes to get to the actual installion

  • @riccbb609
    @riccbb609 4 роки тому +1

    👍👍👍👍👏👏👏👏

  • @mattadulting
    @mattadulting 4 роки тому +3

    Man... No DPS means that your aren't doing access control, you are doing card access, you aren't monitoring anything for control. You aren't installing a fail safe power break on your manual REX. You aren't using an optical REX to follow the "no special knowledge" rules in the NFPA. The optical REX should of course also drop power to the Mag if it loses power itself. You also have no UL listed mag power drop on fire alarm.
    Maglocks are also just about the worst thing to use to learn with due to the additional legal requirements, the extra work to actually align properly, to adjust the door closer for proper contact speed to avoid damaging the Mag body mounts into the header, etc, etc....
    So yeah....you aren't teaching access control.

    • @NellysSecurity
      @NellysSecurity  4 роки тому +1

      Thanks!

    • @ndleinahaystack
      @ndleinahaystack 4 роки тому +3

      Damn... where's your video hater! This is access control because he is in fact "controlling access". Cut it out and stop being miserable.

    • @mattadulting
      @mattadulting 4 роки тому +2

      @@ndleinahaystack I've been teaching access control and other low voltage for a great many years. This video is demonstrating badge access, not access control.

    • @mattadulting
      @mattadulting 4 роки тому +1

      And some of what i brought up is federal code. He shouldn't be teaching something if he doesn't meet code.

    • @bryanquick16
      @bryanquick16 4 роки тому

      Yeah maglocks have myriad of egress requirements. Like you have to have a power interruption in line in the event of a Rex failure. The better option for a beginner video would have been something like a door strike or cylindrical lock that satisfies most egress requirements since they generally have egress on one side built in.

  • @joem13yearsago73
    @joem13yearsago73 2 роки тому

    Dollar store system. S2 lenel galaxy, that's what you want to install

  • @happysonchikohora9789
    @happysonchikohora9789 3 роки тому

    Too much speed

  • @kentmcneill
    @kentmcneill 6 місяців тому

    Turn the music down, FFS.

  • @mohatokeer
    @mohatokeer 3 роки тому

    Please sand me work visa bro please